• 제목/요약/키워드: Overstrength

검색결과 60건 처리시간 0.026초

전단파괴모드를 고려한 철근콘크리트 보통전단벽-골조 건물의 붕괴메커니즘 (Collapse Mechanism of Ordinary RC Shear Wall-Frame Buildings Considering Shear Failure Mode)

  • 추유림;김태완
    • 한국지진공학회논문집
    • /
    • 제25권1호
    • /
    • pp.1-9
    • /
    • 2021
  • Most commercial buildings among existing RC buildings in Korea have a multi-story wall-frame structure where RC shear wall is commonly used as its core at stairways or elevators. The members of the existing middle and low-rise wall-frame buildings are likely arranged in ordinary details considering building occupancy, and the importance and difficulty of member design. This is because there are few limitations, considerations, and financial burdens on the code for designing members with ordinary details. Compared with the intermediate or unique details, the ductility and overstrength are insufficient. Furthermore, the behavior of the member can be shear-dominated. Since shear failure in vertical members can cause a collapse of the entire structure, nonlinear characteristics such as shear strength and stiffness deterioration should be adequately reflected in the analysis model. With this background, an 8-story RC wall-frame building was designed as a building frame system with ordinary shear walls, and the effect of reflecting the shear failure mode of columns and walls on the collapse mechanism was investigated. As a result, the shear failure mode effect on the collapse mechanism was evident in walls, not columns. Consequently, it is recommended that the shear behavior characteristics of walls are explicitly considered in the analysis of wall-frame buildings with ordinary details.

Collapse response assessment of low-rise buildings with irregularities in plan

  • Manie, Salar;Moghadam, Abdoreza S.;Ghafory-Ashtiany, Mohsen
    • Earthquakes and Structures
    • /
    • 제9권1호
    • /
    • pp.49-71
    • /
    • 2015
  • The present paper aims at evaluating damage and collapse behavior of low-rise buildings with unidirectional mass irregularities in plan (torsional buildings). In previous earthquake events, such buildings have been exposed to extensive damages and even total collapse in some cases. To investigate the performance and collapse behavior of such buildings from probabilistic points of view, three-dimensional three and six-story reinforced concrete models with unidirectional mass eccentricities ranging from 0% to 30% and designed with modern seismic design code provisions specific to intermediate ductility class were subjected to nonlinear static as well as extensive nonlinear incremental dynamic analysis (IDA) under a set of far-field real ground motions containing 21 two-component records. Performance of each model was then examined by means of calculating conventional seismic design parameters including the response reduction (R), structural overstrength (${\Omega}$) and structural ductility (${\mu}$) factors, calculation of probability distribution of maximum inter-story drift responses in two orthogonal directions and calculation collapse margin ratio (CMR) as an indicator of performance. Results demonstrate that substantial differences exist between the behavior of regular and irregular buildings in terms of lateral load capacity and collapse margin ratio. Also, results indicate that current seismic design parameters could be non-conservative for buildings with high levels of plan eccentricity and such structures do not meet the target "life safety" performance level based on safety margin against collapse. The adverse effects of plan irregularity on collapse safety of structures are more pronounced as the number of stories increases.

Inelastic behavior of systems with flexible base

  • Fernandez-Sola, Luciano R.;Huerta-E catl, Juan E.
    • Earthquakes and Structures
    • /
    • 제14권5호
    • /
    • pp.411-424
    • /
    • 2018
  • This study explores the inelastic behavior of systems with flexible base. The use of a single degree of freedom system (ESDOF) with equivalent ductility to represent the response of flexible base systems is discussed. Two different equations to compute equivalent ductility are proposed, one which includes the contribution of rigid body components, and other based on the overstrength of the structure. In order to asses the accuracy of ESDOF approach with the proposed equations, the behavior of a 10-story regular building with reinforced concrete (RC) moment resisting frames is studied. Local and global ductility capacity and demands are used to study the modifications introduced by base flexibility. Three soil types are considered with shear wave velocities of 70, 100 and 250 m/s. Soil-foundation stiffness is included with a set of springs on the base (impedance functions). Capacity curves of the building are computed with pushover analysis. In addition, non linear time history analysis are used to asses the ductility demands. Results show that ductility capacity of the soil-structure system including rigid body components is reduced. Base flexibility does not modify neither yield and maximum base shear. Equivalent ductility estimated with the proposed equations is fits better the results of the numerical model than the one considering elastoplastic behavior. Modification of beams ductility demand due to base flexibility are not constant within the structure. Some elements experience reduced ductility demands while other elements experience increments when flexible base is considered. Soil structure interaction produces changes in the relation between yield strength reduction factor and structure ductility demand. These changes are dependent on the spectral shape and the period of the system with fixed and flexible base.

모듈러 구조물의 해석 모델이 지진응답에 미치는 영향 (Influence of Analytical Models on the Seismic Response of Modular Structures)

  • 최경석;이호찬;김형준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권2호
    • /
    • pp.74-85
    • /
    • 2016
  • 모듈러 구조물은 관행적으로 철골 모멘트 저항골조와 유사한 횡력저항성능을 가진다는 가정하에 내진 설계된다. 하지만 모듈러 구조물은 중첩된 구조 부재와 단위 모듈의 체결을 위한 복잡한 접합 상세를 가지기 때문에 철골 모멘트 골조와 다른 하중 전달 메커니즘을 가진다. 본 연구에서는 중첩된 구조 부재 효과와 접합부의 거동 특성을 고려하여 총 4개의 구조해석 모델을 수립하였으며, 수립된 해석 모델을 이용하여 3층과 5층 표본 건물에 대한 비선형 정적 해석을 수행하였다. 표본 건물은 중첩된 구조 부재와 접합부의 이력 거동에 대한 모델링 방법에 따라 강성 및 강도의 차이가 발생하는 것으로 나타났다. 중첩된 구조 부재를 완전 합성, 모듈 간 접합부를 강접합으로 고려하여 설계된 모듈러 구조물은 횡 강성 및 강도가 과대 평가되는 것으로 나타났다. 뿐만 아니라 해석 결과를 통해 3층 이상의 모듈러 구조물은 철골 모멘트 저항골조와 비교하여 상대적으로 적은 초과 강도를 가지는 것을 확인할 수 있다.

An Innovative shear link as damper: an experimental and numerical study

  • Ghamari, Ali;Kim, Young-Ju;Bae, Jaehoon
    • Steel and Composite Structures
    • /
    • 제42권4호
    • /
    • pp.539-552
    • /
    • 2022
  • Concentrically braced frames (CBFs) possess high stiffness and strength against lateral loads; however, they suffer from low energy absorption capacity against seismic loads due to the susceptibility of CBF diagonal elements to bucking under compression loading. To address this problem, in this study, an innovative damper was proposed and investigated experimentally and numerically. The proposed damper comprises main plates and includes a flange plate angled at θ and a trapezius-shaped web plate surrounded by the plate at the top and bottom sections. To investigate the damper behaviour, dampers with θ = 0°, 30°, 45°, 60°, and 90° were evaluated with different flange plate thicknesses of 10, 15, 20, 25 and 30 mm. Dampers with θ = 0° and 90° create rectangular-shaped and I-shaped shear links, respectively. The results indicate that the damper with θ = 30° exhibits better performance in terms of ultimate strength, stiffness, overstrength, and distribution stress over the damper as compared to dampers with other angles. The hysteresis curves of the dampers confirm that the proposed damper acts as a ductile fuse. Furthermore, the web and flange plates contribute to the shear resistance, with the flange carrying approximately 80% and 10% of the shear force for dampers with θ = 30° and 90°, respectively. Moreover, dampers that have a larger flange-plate shear strength than the shear strength of the web exhibit behaviours in linear and nonlinear zones. In addition, the over-strength obtained for the damper was greater than 1.5 (proposed by AISC for shear links). Relevant relationships are determined to predict and design the damper and the elements outside it.

Analytical investigation of the cyclic behaviour of I-shaped steel beam with reinforced web using bonded CFRP

  • Mohabeddine, Anis I.;Eshaghi, Cyrus;Correia, Jose A.F.O.;Castro, Jose M.
    • Steel and Composite Structures
    • /
    • 제43권4호
    • /
    • pp.447-456
    • /
    • 2022
  • Recent experimental studies showed that deep steel I-shaped profiles classified as high ductility class sections in seismic design international codes exhibit low deformation capacity when subjected to cyclic loading. This paper presents an innovative retrofit solution to increase the rotation capacity of beams using bonded carbon fiber reinforced polymers (CFRP) patches validated with advanced finite element analysis. This investigation focuses on the flexural cyclic behaviour of I-shaped hot rolled steel deep section used as beams in moment-resisting frames (MRF) retrofitted with CFRP patches on the web. The main goal of this CFRP reinforcement is to increase the rotation capacity of the member without increasing the overstrength in order to avoid compromising the strong column-weak beam condition in MRF. A finite element model that simulates the cyclic plasticity behavior of the steel and the damage in the adhesive layer is developed. The damage is modelled using the cohesive zone modelling (CZM) technique that is able to capture the crack initiation and propagation. Details on the modelling techniques including the mesh sensitivity near the fracture zone are presented. The effectiveness of the retrofit solution depends strongly on the selection of the appropriate adhesive. Different adhesive types are investigated where the CZM parameters are calibrated from high fidelity fracture mechanics tests that are thoroughly validated in the literature. This includes a rigid adhesive commonly found in the construction industry and two tough adhesives used in the automotive industry. The results revealed that the CFRP patch can increase the rotation capacity of a steel member considerably when using tough adhesives.

초고층 철골대각가새골조의 내진성능평가 (Seismic Performance Evaluation of Highrise Steel Diagrid Frames)

  • 김선웅
    • 한국전산구조공학회논문집
    • /
    • 제24권3호
    • /
    • pp.307-317
    • /
    • 2011
  • 본 논문은 강풍대이면서 약진대에 위치하는 내풍설계된 초고층건물이 경험할 수 있는 잠재적 지진에 대한 내진성능평가를 통해서 탄성내진설계의 가능성을 검토하는 것이다. 최근에 가장 각광받고 있는 구조시스템인 초고층 철골대각가새골조를 내풍설계하고, 내풍설계과정에서 상당한 시스템초과강도가 유입됨을 확인하였다. 초고층 철골대각가새골조에 대하여 다양한 지반조건에 따른 응답스펙트럼해석과 내진성능평가를 수행하였다. 우리나라와 같이 강풍대에 위치하면서 약진대에 속하는 환경하에서 세장비 5.2이상의 초고층 철골대각가새골조는 500년 재현주기 지진동에 대해서는 탄성저항할 수 있음을 보여주었고, 세장비 6.9의 초고층 철골대각가새골조는 2400년 재현주기 지진동에 대해서도 탄성설계가 가능함을 확인하였다. 500년 재현주기 지진동에 대해서 초고층 철골대각가새골조는 부재수준에서 지반조건에 관계없이, 2400년 재현주기 지진동에 대해서도 $S_E$지반을 제외하고는 세장비 5.2이상의 모델에서 모두 "즉시거주" 수준을 나타내었다. 시스템수준에서 초고층 철골대각가새골조는 500년 재현주기 지진동에 대해서 세장비 5.2이상의 모델은 $S_A$$S_B$지반에서는 즉시거주, $S_C{\sim}S_E$ 지반에서는 "인명안전" 수준을 나타내었다. 2400년 재현주기 지진동에 대해서는 500년 재현주기보다 한 단계 낮은 내진성능수준을 보여주었다.

중력하중 설계된 1:5 축소 3층 철근콘크리트 골조의 지진모의실험 (Earthquake Simulation Tests of A 1:5 Scale Gravity Load Designed 3-Story Reinforced Concrete Frame)

  • 이한선;우성우
    • 콘크리트학회지
    • /
    • 제10권6호
    • /
    • pp.241-252
    • /
    • 1998
  • 이 연구의목적은 여러 수준의 지진에 대한 비내진 상세를 가진 저층 모멘트 저항 골조의 실제 반응을 관찰하기 위한 것이다. 우선 모델에 대한 축소율은 사용된 진동대의 용량을 고려하여 1 : 5 로 결정하였으며 상사성의 법칙에 따라 모델을 제작하였다. 그 다음에 이 모델에 대해 Taft N21E 지진가속도 기록의 최대 지진가속도를 0.12g. 0.2g, 0.4g로 조정하여 진동대를 이용한 지진모의실험을 수행하였다. 각 층별 횡방향 가속도와 변위, 그리고 구조물의 취약부위에서 국부변형이 측정되었다. 밑면 전단력은 손수 만든 로드셀을 이용하여 측정하엿다. 각 지진모의실험 전과 후에는 고유주기와 감쇠비의 변화를 살펴보기 위해 자유진동실험을 수행하였다. 전체거동과 국부거동에 대한 실험결과를 분석한 결과, 이 모델은 우리나라의 현행 내진 설계 기준에서의 설계지진 즉, 0.12g의 최대 지진가속에 대해서는 선형탄성으로 거동하였다. 최대 밑면 전단력은 1.8tf 로 설계 밑면 전단력의 약 4.7배로나타났다.이 실험모델은 높은 수준의 지진모의실험에서도 양호한 성능을 나타내었다. 높은 수준의지진에 대한 저항의 주요요소는 1)높은 초과강도, 2)기본주기의 증가, 그리고 3)비탄성 변형에 의한 얼마간의 에너지소산이다. 이 실험에서 모델의 층간변위는 대략 허용한계 내에 있었다.

반강접 접합부 배치에 따른 비가새 5층 철골골조구조물의 비탄성 정적해석 (Pushover Analysis of an Unbraced 5-Story Steel Framed Structure for Arrangement of Semi-Rigid Connection)

  • 강석봉;김신애
    • 한국강구조학회 논문집
    • /
    • 제22권4호
    • /
    • pp.325-334
    • /
    • 2010
  • 본 연구에서는 반강접 접합부 배치에 따른 구조물 거동특성을 파악하기 위하여 KBC2005 건축구조설계기준으로 비가새 5층 철골 구조물을 설계하여 모든 접합부를 완전 강접합부과 반강접 접합부로 이상화한 경우 그리고 반강접 접합부를 수직배치 및 수평배치한 경우에 대하여 푸쉬오버 구조해석을 실시하였다. 철골 보 및 기둥의 모멘트-곡률관계는 화이버모델을 이용하여 확인하였으며 반강접 접합부의 모멘트-회전각 관계는 3-매개변수 파워모델을 이용하여 나타내었다. KBC2005 등가정적횡하중을 받는 2차원 구조물에 대한 푸쉬오버 구조해석을 실시하여 지붕충변위, 밑면전단력, 접합부 요구연성도, 소성힌지 발생순서 그리고 초과강도계수, 연성계수, 반응수정계수와 같은 설계계수 등을 확인하였다. 반강접 접합부를 부분적으로 사용하면 모든 접합부에 반강접 접합부를 사용한 골조 보다 큰 강도 및 강성도를 확보 할 수 있었고 모든 접합부에 강접 접합부를 사용한 골조 보다 큰 연성능력을 확보할 수 있었다. 초과강도계수는 기준과 비슷하였지만 반응수정계수는 기준 보다 훨씬 큰 값을 보였다. TSD 접합부는 예제 구조물에서 경제성과 안전성을 확보할 수 있음을 확인할 수 있었다.

보-기둥 접합부를 고려한 5층 철골골조구조물의 비탄성 정적해석 (Pushover Analysis of a Five-Story Steel Framed Structure Considering Beam-to-Column Connection)

  • 강석봉;이재환
    • 한국강구조학회 논문집
    • /
    • 제22권2호
    • /
    • pp.129-137
    • /
    • 2010
  • 본 연구에서는 횡력을 받는 구조물 거동에 대한 보-기둥 접합부의 영향을 확인하기 위하여 5층 철골구조물을 KBC2005 건축구조설계기준에 맞게 구조설계 하였으며 접합부를 완전 강접합부로 이상화한 경우와 반강접 접합부로 설계하였다. 철골 보 및 기둥의 모멘트-곡률관계는 화이버모델을 이용하여 확인하였으며 반강접 접합부의 모멘트-회전각 관계는 3-매개변수 파워모델을 이용하여 나타내었다. 구조물 거동에 대한 고차모드의 영향을 확인하기 위하여 KBC2005 등가정적 횡하중과 고차모드를 고려한 횡하중을 재하하였다. 5층 철골구조물은 개별 골조와 연결골조의 2차원 구조물로 이상화하였다. 횡하중을 받는 2차원 구조물에 대한 푸쉬오버 구조해석을 실시하여 지붕충변위-밑면전단력, 초과강도계수, 연성계수, 반응수정계수와 같은 설계계수, 접합부 요구연성도 그리고 소성힌지 분포 등을 확인하였다. 예제 구조물은 기준의 반응수정계수 보다 큰 값을 보였고 고차모드의 반응수정계수에 대한 영향은 거의 없었고 KBC2005 횡하중은 안전한 편에 속했다. TSD 접합부는 예제 구조물에서 경제성과 안전성을 확보할 수 있음을 확인할 수 있었다.