• Title/Summary/Keyword: Overall pressure ratio

Search Result 197, Processing Time 0.024 seconds

Experimental assessment of the effect of frozen fringe thickness on frost heave

  • Jin, Hyun Woo;Lee, Jangguen;Ryu, Byun Hyun;Shin, Yunsup;Jang, Young-Eun
    • Geomechanics and Engineering
    • /
    • v.19 no.2
    • /
    • pp.193-199
    • /
    • 2019
  • A frozen fringe plays a key role in frost heave development in soils. Previous studies have focused on the physical and mechanical properties of the frozen fringe, such as overall hydraulic conductivity, water content and pore pressure. It has been proposed that the thickness of the frozen fringe controls frost heave behavior, but this effect has not been thoroughly evaluated. This study used a temperature-controllable cell to investigate the impact of frozen fringe thickness on the characteristics of frost heave. A series of laboratory tests was performed with various temperature boundary conditions and specimen heights, revealing that: (1) the amount and rate of development of frost heave are dependent on the frozen fringe thickness; (2) the thicker the frozen fringe, the thinner the resulting ice lens; and (3) care must be taken when using the frost heave ratio to characterize frost heave and evaluate frost susceptibility because the frost heave ratio is not a normalized factor but a specimen height-dependent factor.

Comparison of Pulmonary Function, Respiratory Muscle Strength, and Diaphragm Thickness between Underweight and Normal Adults

  • Ho-Jeong Shin;Ho-Hee Son
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.18 no.3
    • /
    • pp.31-37
    • /
    • 2023
  • PURPOSE: This study aimed to investigate the relationship between being underweight and respiratory function indicators such as pulmonary function, respiratory muscle strength, and diaphragm thickness in normal adults without lung disease. METHODS: The participants in this experiment were thirty young adults. To compare the respiratory function between the underweight and normal weight individuals, 15 participants were selected from each of the underweight and normal weight groups based on body mass index. Respiratory function tests were conducted through pulmonary function tests and respiratory muscle strength tests. Diaphragm thickness was measure with ultrasonography, and physical characteristics were obtained from grip strength and waist circumference. An independent t-test was used to compare the averages of the parameters measured in the two groups. RESULTS: In the respiratory function tests between the two groups, statistically significant differences (p < .05) emerged in the ratio of the predicted forced vital capacity (%FVC), the ratio of the predicted forced expiratory volume in one second (%FEV1), maximal expiratory pressure (MEP), and diaphragm thickness at the functional residual capacity (FRC). There was no statistically significant difference in the forced vital capacity, forced expiratory volume in one second, maximal inspiratory pressure, diaphragm thickness at the total lung capacity, and thickening ratio (p > .05). CONCLUSION: Decreases in some variables of respiratory function, such as the %FVC, %FEV1, MEP, and diaphragm thickness at the FRC were observed in underweight subjects. However, it is difficult to determine whether it affected the overall respiratory function. Future studies are needed to clearly identify the relationship between being underweight and respiratory function.

Quality Characteristics of Sauce for Meat prepared with Mulberry Leaf Powder and Mulberry Fruit Powder (뽕잎과 오디분말을 이용한 육류용 소스 제조 및 품질평가)

  • Kim, Ae-Jung;Lee, Jung-Ae;Kim, Min-Ju;Kang, Mi-Sook;Kim, Hyun-Bok;Lim, Jung-Dae
    • The Korean Journal of Food And Nutrition
    • /
    • v.29 no.4
    • /
    • pp.513-520
    • /
    • 2016
  • Recently, the incidence of cardiovascular diseases including high blood pressure and heart disease has increased with increased meat consumption in Korea. This study was performed to determine the optimal mixing ratio among ratios of 0, 1:0, 0:1, 1:1, 2:1, and 1:2 of mulberry leaf powder to mulberry fruit powder based on the anti-inflammatory effects. Then, the quality characteristics of the sauce for meat prepared with different mixing ratios (0, 1:1, 1:2, 1:3, 1:4, and 1:5) of mulberry leaf powder to mulberry fruit powder were assessed. The inhibitory effects of ML2MF1 (2:1 ratio of mulberry leaf powder to mulberry fruit powder) on NO and TNF-${\alpha}$ production were superior to those of other mixing ratios. With respect to color values of the sauce for meat prepared with different mixing ratio of mulberry leaf powder to mulberry fruit powder, as the mulberry fruit powder mixing ratios was increased, redness was increased but lightness and yellowness were decreased. The sensory evaluation of ML1MF5S (1:5 ratio of mulberry leaf powder to mulberry fruit powder) sauce for meat showed the highest score with respect to color, smell, taste, harmony with meat and the overall preference. In conclusion, as the mulberry leaf powder mixing ratio was increased, the anti-inflammatory activities were increased. But sensory evaluation scores were increased as the mulberry fruit powder mixing ratio was increased. Therefore, by performing further study, the method to increase mulberry leaf powder in the mixing ratio for improving the sensory evaluation should be provided.

Improved Momentum Exchange Theory for Incompressible Regenerative Turbomachines (II) - Loss Model and Performance Prediction - (비압축성 재생형 기계에 대한 개선된 운동량 교환 이론 (II) - 손실 모델 및 성능 예측 -)

  • Park Mu Ryong;Chung Myung Kyoon;Yoo Il Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.10
    • /
    • pp.1247-1254
    • /
    • 2004
  • In momentum exchange theory the loss models for the circulatory flow is critically important. But because of lack of loss model on the circulatory flow, analysis model on regenerative turbomachines is not available in the open literature. In the present study circulatory loss is evaluated by combining bend's losses. Through the comparison with the previous experimental data on linear pressure gradient, a combination factor is suggested in terms of the aspect ratio of a channel. Applying this factor to two kinds of regenerative blowers the predicted results are found to be in good agreement with the experimental data of the overall performance and the head distribution along the rotational direction. Especially, the comparison with the head distribution demonstrates the accuracy of hydraulic model and loss model suggested in the present study. And the comparison with the overall performance confirms the validness of physical models as well as loss models suggested in the present study.

Numerical and statistical analysis of permeability of concrete as a random heterogeneous composite

  • Zhou, Chunsheng;Li, Kefei
    • Computers and Concrete
    • /
    • v.7 no.5
    • /
    • pp.469-482
    • /
    • 2010
  • This paper investigates the concrete permeability through a numerical and statistical approach. Concrete is considered as a random heterogeneous composite of three phases: aggregates, interfacial transition zones (ITZ) and matrix. The paper begins with some classical bound and estimate theories applied to concrete permeability and the influence of ITZ on these bound and estimate values is discussed. Numerical samples for permeability analysis are established through random aggregate structure (RAS) scheme, each numerical sample containing randomly distributed aggregates coated with ITZ and dispersed in a homogeneous matrix. The volumetric fraction of aggregates is fixed and the size distribution of aggregates observes Fuller's curve. Then finite element method is used to solve the steady permeation problem on 2D numerical samples and the overall permeability is deduced from flux-pressure relation. The impact of ITZ on overall permeability is analyzed in terms of ITZ width and contrast ratio between ITZ and matrix permeabilities. Hereafter, 3680 samples are generated for 23 sample sizes and 4 contrast ratios, and statistical analysis is performed on the permeability dispersion in terms of sample size and ITZ characteristics. By sample theory, the size of representative volume element (RVE) for permeability is then quantified considering sample realization number and expected error. Concluding remarks are provided for the impact of ITZ on concrete permeability and its statistical characteristics.

Thermal-hydraulic Design of A Printed-Circuit Steam Generator for Integral Reactor (일체형원자로 인쇄기판형 증기발생기 열수력학적 설계)

  • Kang, Han-Ok;Han, Hun Sik;Kim, Young-In
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.6
    • /
    • pp.77-83
    • /
    • 2014
  • The vessel of integral reactor contains its major primary components such as the fuel and core, pumps, steam generators, and a pressurizer, so its size is proportional to the required space for the installation of each component. The steam generators take up the largest volume of internal space of reactor vessel and their volumes is substantial for the overall size of reactor vessel. Reduction of installation space for steam generators can lead to much smaller reactor vessel with resultant decrease of overall cost for the components and related facilities. A printed circuit heat exchanger is one of the compact types of heat exchangers available as an alternative to conventional shell and tube heat exchangers. Its name is derived from the procedure used to manufacture the flat metal plates that form the core of the heat exchanger, which is done by chemical milling. These plates are then stacked and diffusion bonded, converting the plates into a solid metal block containing precisely engineered fluid flow passages. The overall heat transfer area and pressure drops are evaluated for the steam generator based on the concept of the printed circuit heat exchanger in this study. As the printed circuit heat exchanger is known to have much larger heat transfer area density per unit volume, we can expect significantly reduced steam generator compared to former shell and tube type of steam generator. For the introduction of new steam generator, two design requirements are considered: flow area ratio between primary and secondary flow paths, and secondary side parallel channel flow oscillation. The results show that the overall volume of the steam generator can be significantly reduced with printed circuit type of steam generator.

Association of Anthropometric Indices with Prevalence of Hypertension in Korean Adult (일부 지역 주민에서 고혈압이환과 비만지표와의 관련성)

  • Son, Lack-Seong;Yoon, Tai-Young;Choi, Joong-Myung;Park, Soon-Young;Lew, Dong-Joon;Choe, Bong-Keun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.32 no.4
    • /
    • pp.443-451
    • /
    • 1999
  • Objective: To examine the relationship between hypertension prevalence and the four commonest anthropometric measurements for obesity(body mass index(BMI), wasit-hip ratio(WHR), waist circumference(WC) and body fat in Korean adults. Methods: We studied the cross-sectional association of the anthropometric indices and blood pressure in 1,197 individuals(who were participants in the population-based cohort study). Hypertension was defined as blood pressure $\geq160/95\;mmHg$ or current use of antihypertensive medication. Informations on life-style factors were obtained from personal interview. Results: There were close associations between BMI, WHR and WC with blood pressure in both men and women. After age adjustment, BMI and WC showed significantly positive correlation with systolic and diastolic blood pressure levels in both men and women. Odds ratio(ORs) of being hypertensive were estimated comparing the highest to the lowest quantile, adjusting for age, smoking status, alcohol intake levels, education attainment. The simultaneously adjusted ORs of being hypertensive, comparing the highest vs the lowest categories, was for BMI 2.0(95% confidence interval(CI)=0.9-3.2) in men and 3.2 (95% CI=1.7-6.1) in women, for WC 2.1(95% CI=1.0-4.4) in men and 3.1 (95% CI=1.6-5.9) in women, for fat(%) 4.2(95% CI=1.9-9.5) in men and 2.1(95% CI=1.2-3.6) in women. Conclusion: In addition to measures of overall obesity(BMI) as well as central obesity(WHR, WC), body fat(%) was independently associated with prevalence of hypertension. Among obesity indices, body fat was the most predictor variable in hypertensive state in male and BMI was in female.

  • PDF

A Study on the Bypass Flow Penetrating Through a Gas Diffusion Layer in a PEM Fuel Cell with Serpentine Flow Channels (사행유로를 갖는 고분자연료전지내부에서 가스확산층을 통과하는 반응가스 우회유동에 대한 연구)

  • Cho, Choong-Won;Ahn, Eun-Jin;Lee, Seung-Bo;Yoon, Young-Gi;Lee, Won-Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.4
    • /
    • pp.288-297
    • /
    • 2009
  • A serpentine channel geometry often used in a fuel cell has a strong pressure gradient between adjacent channels in specific regions. The pressure gradient helps some amount of reactant gas penetrate through a gas diffusion layer(GDL). As a result, the overall serpentine flow structure is slightly different from the intention of a designer. The purpose of this paper is to examine the effect of serpentine flow structure on current density distribution. By using a commercial code, STAR-CD, a numerical simulation is performed to analyze the fuel cell with high aspect ratio of active area. To increase the accuracy of the numerical simulation, GDL permeabilities are measured with various compressive forces. Three-dimensional flow field and current density distribution are calculated. For the verification of the numerical simulation results, water condensation process in the cathode channel is observed through a transparent bipolar plate. The result of this study shows that the region of relatively low current density corresponds that of dropwise condensation in cathode channels.

Control of the Supersonic Jet Noise Using a Wire Device (와이어 장치를 이용한 초음속 제트소음의 제어)

  • Kweon Yong Hun;Lim Chae Min;Aoki Toshiyuki;Kim Heuy Dong
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.64-67
    • /
    • 2004
  • The present study describes an experimental work to reduce supersonic jet noise using a control wire device that is placed into the supersonic jet stream. The jet pressure ratio is varied to obtain the supersonic jets which are operated in a wide range of over-expanded to moderately under-expanded conditions. The wire device is composed of long cylinders with a very small diameter. X-type wire device is applied to control the supersonic jet noise, and its location is varied to investigate the effect of the control wire device on supersonic jet noise. A high-quality Schlieren optical system is used to visualize the flow field of supersonic jet with and without the control wire device. Acoustic measurement is performed to obtain the overall sound pressure level and noise spectra. The results obtained show that the present wire device destroys the shock-cell structures, reduces the shock strength, and consequently leading to a substantial suppression of supersonic jet noise.

  • PDF

The Effect of a Bypass Flow Penetrating through a Gas Diffusion Layer on Performance of a PEM Fuel Cell (가스확산층을 통과하는 반응가스 우회유동이 고분자 연로전지의 성능에 미치는 영향)

  • Cho, Choong-Won;Ahn, Eun-Jin;Lee, Seung-Bo;Lee, Won-Yong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.147-151
    • /
    • 2007
  • A serpentine channel geometry often used in a polymer electrolyte membrane fuel cell has a strong pressure gradient between adjacent channels in specific regions. The pressure gradient helps some amount of reactant gas penetrate through a gas diffusion layer(GDL). As a result, the overall serpentine flow structure is slightly different from intention of a designer. The purpose of this paper is to examine the effect of serpentine flow structure on current density distribution. By using a commercial code, STAR-CD, a numerical simulation is performed to analyze the fuel cell with relatively high aspect ratio active area. To increase the accuracy of the numerical simulation, GDL permeabilities are measured with various compression conditions. Three-dimensional flow field and current density distribution are calculated. For the verification of the numerical simulation results, water condensation process in the cathode channel is observed through a transparent bipolar plate. The result of this study shows that the region of relatively low current density corresponds to that of dropwise condensation in cathode channels.

  • PDF