• 제목/요약/키워드: Overall heat loss coefficient

검색결과 19건 처리시간 0.026초

엔진 냉각 시스템 개선에 관한 연구 (A Study on Improvement of Engine Cooling System)

  • 김문헌;오병욱
    • 한국자동차공학회논문집
    • /
    • 제2권2호
    • /
    • pp.103-116
    • /
    • 1994
  • In this study the behavior of engine cooling loss and overall heat transfer coefficient were studied experimentally using naturally aspirated engine and turbo charged engine. Using turbo charging, heat dissipation was increased because of the density of the mixture was increased with increment of inlet air flow rate. Therefore, cooling loss of turbo charged engine is larger than naturally aspirated engine. As taking the measurement of surface temperature of combustion chamber, gas heat transfer coefficient was calculated and found that it has greatly affected to overall heat transfer coefficient. The empirical formula of overall heat transfer coefficient established in order to predict of engine cooling loss and express only as a function of mean piston velocity.

  • PDF

플라스틱온실 피복재의 관류열전달계수 변화 (Variation of the Overall Heat Transfer Coefficient of Plastic Greenhouse Covering Material)

  • 이현우;소레이멘디옵;김영식
    • 생물환경조절학회지
    • /
    • 제20권2호
    • /
    • pp.72-77
    • /
    • 2011
  • 본 연구는 국내 상업용 온실 피복재의 관류열전달계수를 산정히는데 필요한 기초자료를 제공하기 위하여 최근 국내에 많이 보급되어 사용되고 있는 플라스틱필름으로 피복된 온실에 대해 관류열량을 측정하고 관류열전달계수의 변화를 분석하였으며 그 결과를 요약하면 다음과 같다. 온실 내외부 온도차에 따른 관류열전달계수의 변화를 분석한 결과 피복의 층수에 따라 안정된 관류열전달계수를 나타내게 되는 온실 내외부 온도차의 값이 다르게 나타났기 때문에 온실 피복재에 대한 관류열전달계수를 결정할 때에는 피복층수별로 안정된 값을 나타내는 온실 내외부 온도차 범위에서의 관류열전달계수를 채택하여야할 것이다. 온도차이에 따른 관류열전달계수의 변화 경향은 기존의 연구결과와 잘 일치하였으나 안정된 값을 나타내는 온도차이의 구체적인 값은 다르게 나타났기 때문에 이에 대한 추가적인 연구가 필요할 것으로 판단된다. 풍속에 따른 관류열전달계수의 증가율은 연구자에 따라 많은 차이가 있음을 알 수 있었으며, 이중피복온실이나 커튼을 설치한 온실과 같이 보온성을 높인 온실은 일중피복온실에 비해 풍속에 따른 관류열 손실이 더 작다는 사실을 확인할 수 있었다. 관류열전달계수의 기존 연구결과들을 분석한 결과 연구자에 따라 값이 차이가 있었기 때문에 국내 온실의 정확한 난방부하량을 산정하는데 필요한 적절한 관류열전달계수를 제시하기 위해서는 우선 측정을 위한 표준화된 환경기준이 마련될 필요가 있으며, 또한 국내에서 실제로 사용되고 있는 주요 피복재별로 구체적인 관류열전달계수가 구해져야 할 것이다.

일중효용 사이클과 일중효용/2단승온 사이클을 이용한 태양열 흡수식 냉방시스템의 비교 (Comparison Between Two Solar Absorption Cooling System Using Single Effect and Single Effect/Double Lift Cycle)

  • 정시영;이상수;조광운;백남춘
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.267-276
    • /
    • 2000
  • A numerical study has been carried out to find out the optimal design condition of a solar absorption cooling system. The system was composed of solar collectors and an absorption chiller with LiBr/water The System performance with commercial single effect(SE) cycle and a new single effect/double lift(SE/DL) cycle utilizing low temperature hot water was calculated and compared. It was found that the required solar collector area grew exponentially as the overall heat loss coefficient of solar collectors increased. For instance, the required area for cooling capacity of 1 USRT was $17m^2$ if heat loss coefficient was 4 W/$m^2\;cdot\;K$. If heat loss coefficient was doubled($8\;W/m^2\;cdot\;$K), the required collector area was increased by 6 times($100m^2$) .It was also found that the SE-cycle as the heat loss coefficient of solar collectors increased. Generally, a SE/DL-cycle seems to be more advantageous than a SE-cycle if loss coefficient of solar collector is greater than 4 W/$m^2\;cdot\;K$.

  • PDF

다층 지반의 열전도율을 고려한 해저배관의 총괄열전달계수식 제안 (Proposed OHTC Formula for Subsea Pipelines Considering Thermal Conductivities of Multi-Layered Soils)

  • 박동수;신문범;서영교
    • 한국해양공학회지
    • /
    • 제32권2호
    • /
    • pp.84-94
    • /
    • 2018
  • Subsea pipelines are designed to transport mixtures of oil, gas, and their associated impurities from a wellhead that can be in excess of approximately $100^{\circ}C$, while the external temperature may be approximately $5^{\circ}C$. Heat can be lost from a subsea pipeline containing a high-temperature fluid to the surrounding environment. It is important that the pipeline be designed to ensure that the heat loss is small enough to maintain sufficient flow from the unwanted deposition of hydrate and wax, which occurs at a critical temperature of about $40^{\circ}C$. Therefore, it is essential to estimate the heat loss of a subsea pipeline in various circumstances. In previous studies, overall heat transfer coefficient(OHTC) formulas were considered only for a single soil type. Thus, it is difficult to characterize the OHTC of the actual seabed with multiple soil layers. In this paper, an OHTC formula that considers multi-layered soils is proposed for more precise OHTC estimation.

온실 난방부하 산정방법의 검증 및 틈새환기와 지중전열의 영향 분석 (Validation of Load Calculation Method for Greenhouse Heating Design and Analysis of the Influence of Infiltration Loss and Ground Heat Exchange)

  • 신현호;남상운
    • 원예과학기술지
    • /
    • 제33권5호
    • /
    • pp.647-657
    • /
    • 2015
  • 원예시설의 환경설계 중 난방부하 산정방법에 대한 검증을 위하여, 대규모 플라스틱 온실에서 총난방부하와 틈새환기율, 지중전열량을 계측하여 계산결과와 비교 분석하였고, 지중전열 및 틈새환기가 온실의 난방부하에 미치는 영향을 검토하였다. 실험기간 동안 실내기온은 $13.3{\pm}1.2^{\circ}C$, 실외 기온은 $-9.4{\sim}+7.2^{\circ}C$의 범위를 보였으며, 우리나라의 난방 설계 외기온 범위에서 유효한 것으로 확인하였다. 가스트레이서법으로 측정한 틈새환기율은 평균 $0.245h^{-1}$로 나타났다. 온실의 피복면적에 일정한 환기전열계수값을 사용하는 방법은 온실의 규모에 따라서 문제가 있는 것으로 분석되었다. 따라서 환기전열부하는 온실의 체적과 틈새환기율을 이용하는 방법이 합리적인 것으로 판단된다. 온실 중앙에서 측정한 지중열류는 실내외 기온차에 따라 음으로 약간 증가하는 경향을 보이고, 온실 측면에서 측정한 지중열류는 실내외 기온차에 따라 양으로 크게 증가하는 경향을 보였다. 계측 결과를 바탕으로 온실의 외주부를 통한 열손실 개념을 도입한 새로운 지중전열부하 산정 방법을 개발하였으며, 검증결과 잘 일치하는 것으로 나타났다. 관류열부하는 대체로 실내외 기온차에 비례하는 것으로 나타났으나, 열관류율은 작아지는 경향을 보였다. 따라서 관류열부하 산정시 설계조건에 따라 열관류율의 선택에 주의를 기울여야 할 것으로 판단된다. 실험온실의 열관류율은 평균 $2.73W{\cdot}m^{-2}{\cdot}C^{-1}$로 단일피복의 플라스틱 온실 대비 60%의 열절감율을 보이는 것으로 나타났다. 전체 난방부하 중에서 관류열부하가 84.7~95.4%, 환기전열부하가 4.4~9.5%, 지중전열부하가 -0.2~+6.3%를 차지하는 것으로 나타났다. 관류열부하는 실내외 기온차가 낮은 그룹에서 더 큰 비율을 차지하고, 환기전열 부하는 실내외 기온차가 높은 그룹에서 더 큰 비율을 차지하는 것으로 나타났다. 지중전열부하의 경우 실내외 기온차가 낮은 그룹에서는 부하를 경감시키는 방향으로 작용하고, 실내외 기온차에 따라 부하를 증가시키거나 경감시키는 방향으로 작용하는 것으로 나타났으므로 이 기준 온도차의 선택이 중요한 것으로 판단된다. 지중전열부하에 비하여는 환기전열부하가 더 큰 비중을 차지하므로 에너지 절감을 위해서는 틈새환기율을 줄일 수 있는 대책이 필요한 것으로 판단된다.

A Study on Heat Loss from Offshore Pipelines Depending on the Thermal Conductivity of Backfills and Burial Depth

  • Park, Dong-Su;Seo, Young-Kyo
    • Journal of Advanced Research in Ocean Engineering
    • /
    • 제4권1호
    • /
    • pp.1-6
    • /
    • 2018
  • Subsea pipelines are designed to transport mixtures of oil, gas, and their associated impurities from the wellhead that can have temperatures as high as $100^{\circ}C$, while the external temperature can be as low as $5^{\circ}C$. Heat can be lost from the subsea pipeline containing high-temperature fluid to the surrounding environment. It is important that the pipeline is designed to ensure that the heat loss is small enough to maintain flow and avoid the unwanted deposition of hydrate and wax, which occurs at a critical temperature of approximately $40^{\circ}C$. Therefore, it is essential to know the heat loss of subsea pipelines under various circumstances. This paper presents a comparison between numerical analyses and existing theoretical formulas for different backfills and burial depth.

이중진공관형 태양열 집열기의 성능시험에 관한 연구 (Study on Performance Testing of Concentric Evacuated Tube Solar Energy Collector System)

  • 윤영환;김경환
    • 한국태양에너지학회 논문집
    • /
    • 제25권2호
    • /
    • pp.19-26
    • /
    • 2005
  • Concentric evacuated tube solar energy collector has been interested recently since government has driven to install alternative energy systems in new large building. In this paper, testing of the evacuated tube collector is conducted in outdoor during daytime by transient method. The collector thermal efficiencies are plotted in term of $(T_{in}-T_a)/Ic$, where $T_{in}$ is inlet working fluid temperature, $T_a$ is atmospheric temperature and $I_c$ is solar irradiation on the collector surface. The evacuated tube collector efficiency is ranged from 50% to 63% in real outdoor condition. In addition, the total overall heat loss coefficient is found to have an inverse variation to $(T_{in}-T_a)/I_c$ so that the coefficient becomes very high when $(T_{in}-T_a)/I_c$ is small.

항공기용 PAO-공기 열교환기 성능분석 연구 (A Study on the Performance Analysis of the PAO-AIR Heat Exchangers in an Aircraft)

  • 박동명;정용인;문우용;박성순
    • 한국항공우주학회지
    • /
    • 제40권11호
    • /
    • pp.934-939
    • /
    • 2012
  • 본 연구는 무인항공기의 환경제어계통에 적용되는 PAO-공기 열교환기에 대한 성능검증에 관한 것으로, 계통에 대한 성능분석을 통해 열교환기 성능목표를 설정하고 상세설계와 정밀제작을 통해 목표성능에 부합되는 열교환기를 개발하였다. 개발된 PAO-공기 열교환기의 성능을 입증하기 위해 열교환기의 설계점 외에 다양한 시험조건에 대한 압력손실과 열전달 유용도, 총괄열전달계수 등에 대해 시험을 수행하였다. 수행된 결과를 바탕으로, 무인항공기용 환경제어계통에 적용된 PAO-공기 열교환기의 성능과 특성을 분석하여 개발적합성에 대해 검증하였다.

BES를 이용한 온실용 보온커튼의 관류열전달계수 산정 (Evaluation of Overall Heat Transfer Coefficient of Different Greenhouse Thermal Screens Using Building Energy Simulation)

  • 라쉬드아드난;이종원;이현우
    • 생물환경조절학회지
    • /
    • 제27권4호
    • /
    • pp.294-301
    • /
    • 2018
  • 겨울철에 열손실을 줄이기 위해 많은 온실에서 보온커튼을 사용하고 있다. 그러나 적절한 보온커튼을 선택할 때 판단 자료로 활용할 수 있는 명확한 기준이 없는 실정이며 이를 위해서는 보온재의 보온 특성에 대한 정량적인 값이 필요하다. 본 연구에서는 BES를 사용하여 보온커튼의 관류열전달계수를 산정하는 시뮬레이션 모델을 개발하였다. 일중 및 이중 PE필름 피복에 대한 관류열전달계수의 실험값을 사용하여 시뮬레이션 결과를 검증하였다. 검증된 모델을 사용하여 문헌에서 제시된 각종 열적 특성을 가진 보온커튼에 대한 관류열전달계수를 산정하고 비교분석하였다. 개발된 시뮬레이션 모델은 다양한 보온커튼의 관류열전달계수를 산정하는 데 활용될 수 있을 것이며, 제시된 관류열전달계수는 보온커튼의 성능을 정량적으로 비교하는데 유용하게 활용될 수 있을 것으로 판단된다.

간척지 설치 온실의 난방부하 특성 분석 (Analysis of Heating Load Characteristics for Greenhouses Constructed in Reclaimed Lands)

  • 남상운;신현호
    • 한국농공학회논문집
    • /
    • 제59권6호
    • /
    • pp.1-8
    • /
    • 2017
  • The purpose of this study was to provide basic data for development of environmental design technology for greenhouses constructed in reclaimed lands. We analyzed the climatic conditions around seven major reclaimed land areas in Korea, which have a plan to install advanced horticultural complexes. The characteristics of heating load through the thermal environment measurement of the greenhouse in Saemangeum were analyzed. The part to be applied to the environmental design of the greenhouses in reclaimed lands were reviewed. The overall heat transfer coefficient of the experimental greenhouse with the aluminum screen and multi-layer thermal curtain averaged $3.79W/m^2^{\circ}C$. It represents a 44 % heat savings rate compared with plastic greenhouses with a single covering, which was significantly lower than that of the common greenhouses with 2-layer thermal curtains. This is because the experimental greenhouse was installed on reclaimed land and wind was stronger than the inland area. Among the total heating load, the transmission heat loss accounted for 96.4~99.9 %, and the infiltration loss and the ground heat exchange were low. Therefore, it is necessary to take countermeasures to minimize the transmission heat loss for greenhouses constructed in reclaimed lands. As the reclaimed land is located on the seaside, the wind is stronger than the inland area, and the fog is frequent. Especially, Saemangeum area has 2.6 times stronger wind speed and 3.4 times longer fog duration than the inland area. In designing the heating systems for greenhouses in reclaimed lands, it is considered that the maximum heating load should be calculated by applying the wind coefficient larger than the inland area. It is reasonable to estimate the operation cost of the heating system by applying the adjustment factor 10 % larger than the average in calculating the seasonal heating load.