• Title/Summary/Keyword: Over-the-head

Search Result 1,195, Processing Time 0.029 seconds

Field-in-Field Technique to Improve Dose Distribution in the Junction of the Field with Head & Neck Cancer (Field-in-Field Technique을 이용한 두경부암의 접합부위 선량개선에 관한 고찰)

  • Kim, Seon-Myeong;Lee, Yeong-Cheol;Jeong, Deok-Yang;Kim, Young-Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.17-23
    • /
    • 2009
  • Purpose: In treating head and neck cancer, it is very important to irradiate uniform dose on the junction of the bilateral irradiation field of the upper head and neck and the anterior irradiation field of the lower neck. In order to improve dose distribution on the junction, this study attempted to correct non uniform dose resulting from under dose and over dose using the field-in-field technique in treating the anterior irradiation field of the lower neck and to apply the technique to the treatment of head and neck cancer through comparison with conventional treatment. Materials and Methods: In order to examine dose difference between the entry point and the exit point where beam diffusion happens in bilateral irradiation on the upper head and neck, we used an anthropomorphic phantom. Computer Tomography was applied to the anthropomorphic phantom, the dose of interest points was compared in radiation treatment planning, and it was corrected by calculating the dose ratio at the junction of the lower neck. Dose distribution on the junction of the irradiated field was determined by placing low-sensitivity film on the junction of the lower neck and measuring dose distribution on the conventional bilateral irradiation of the upper head and neck and on the anterior irradiation of the lower neck. In addition, using the field-in-field technique, which takes into account beam diffusion resulting from the bilateral irradiation of the upper head and neck, we measured difference in dose distribution on the junction in the anterior irradiation of the lower neck. In order to examine the dose at interest points on the junction, we compared and analyzed the change of dose at the interest points on the anthropomorphic phantom using a thermoluminescence dosimeter. Results: In case of dose sum with the bilateral irradiation of the upper head and neck when the field-in-field technique is applied to the junction of the lower neck in radiation treatment planning, The dose of under dose areas increased by 4.7~8.65%. The dose of over dose areas also decreased by 2.75~10.45%. Moreover, in the measurement using low-sensitivity film, the dose of under dose areas increased by 11.3%, and that of over dose areas decreased by 5.3%. In the measurement of interest point dose using a thermoluminescence dosimeter, the application of the field-in-field technique corrected under dose by minimum 7.5% and maximum 17.6%. Thus, with the technique, we could improve non.uniform dose distribution. Conclusion: By applying the field-in-field technique, which takes into account beam divergence in radiation treatment planning, we could reduce cold spots and hot spots through the correction of dose on the junction and, in particular, we could correct under dose at the entry point resulting from beam divergence. This study suggests that the clinical application of the field-in-field technique may reduce the risk of lymph node metastasis caused by under dose on the cervical lymph node.

  • PDF

A Simple Estimation of the Viscous Resistance of Ships by Wake Surveys

  • Shin-Hyoung,Kang;Beom-Soo,Hyun
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.19 no.2
    • /
    • pp.19-25
    • /
    • 1982
  • Several formulae have been proposed to estimate the viscous resistance of ships by wake surveys. Both the total head and the velocity should be measured. The integration of he total head loss shows over estimations of the resistance by about 10%. Therefore measurements of the velocity are required, which need much more works. A simple method is suggested in this paper to take accout of the velocity-defect from the measured total head. It gives reasonable estimations of the viscous resistance within the experimental accuracy. Experimental data of a low-drag body of revolution in the wind-tunnel and Series 60 model, CB=0.6 in the tank are used to verify the suggested formula.

  • PDF

Flying Characteristics of Running Tape above Rotating Head (I) (회전헤드에 대한 주행테이프의 부상특성 ( I ))

  • 민옥기;김수경
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.2
    • /
    • pp.523-536
    • /
    • 1991
  • This dissertation analyzes the running mechanism of flexible and thin tape above rotating head through the numerical simulation and the experiment. The scope of analysis is confined to the phenomena of two dimensional elasto hydrodynamic lubrication between the protruded bump on a rotating cylinder and the running tape. This model is based on the elastic deformation equation of plate and shell and Reynolds equation. Finite difference method is employed as a numerical technique to calculate (1) the distribution of pressure between the running tape and rotating bump and (2) the vertical deformation of elastic thin tape over he rotating bump under hydrodynamic pressure. In numerical analyses, the effects of bump size on flying characteristics of the tape were evaluated and examined considering the influence of tension and stiffness of tape.

Design and Fabrication of Micro Laser Module for Heat Assisted Magnetic Recording (차세대 열 보조 자지기록용 마이크로 레이저 모듈 설계 및 제작)

  • Lee, S.C.;Choi, Y.B.;Kim, Y.J.;Kim, D.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.68-69
    • /
    • 2009
  • Heat Assisted Magnetic Recording (HAMR) is one of the most promising candidates for high density magnetic storages over 1 Tb/$in^2$ areal density. Since the precise light delivery to the head is a key factor to realize HAMR application, it is required to establish the light delivery using micro laser module and micro actuator. For the careful control of micro actuator, a laser module was designed including laser diode, optical fiber, collimating lens, and fabricated V-groove substrate. In addition, the basic aligning method between the laser module and HAMR head was studied by the detection of current change in photo diode due to the amount of reflected light from the head.

  • PDF

The effects of high sustained +Gz under different seat back angles (조종석 각도변화가 양성 가속도에 미치는 영향에 관한 연구)

  • 이창민;박세권
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.69-78
    • /
    • 1996
  • Current fighter pilots, flying new generation aircrafts with high performance, are under severe stress during aerial combat maneuvering when they are exposed to high sustained +Gz(Head-to-foot) acceleration stress. Two major factor limiting performance during high sustaied +Gz acceleration stress are loss of vision-greyout or blackout, and loss of consciousness (LOC). These symptoms are believed to occur as a result of insuff- icient blood flow to the retina and the brain. This study was conducted to evaluate the effects of high sustained +Gz stress under different seat back angle. The results. obtained by the biodvanmic computer simulations using the ATB(articulated total body) model, are represented with respect to three variables, such as HIC(head injury criterion) value, average G, and maximum G. The results demonstrate that the seat back angle(over $30^{\circ}C$) had a significant effect to decrease +Gz stress on the head segment and had no significant effect on HIC.

  • PDF

A Case of Metastatic Squamous Cell Carcinoma Presenting as a Cystic Neck Mass (경부 낭종으로 발견된 전이성 편평세포암)

  • Kim Sang-Hyun;Choi Yeun-Kuk;Park Suk-Ah
    • Korean Journal of Head & Neck Oncology
    • /
    • v.14 no.2
    • /
    • pp.260-262
    • /
    • 1998
  • Metastatic squamous carcinoma of the head and neck may rarely present as a cyst in the cervical region. The true incidence of metastatic cystic neck mass is unknown. It is difficult to differentiate metastatic cystic neck mass from congenital cystic neck mass with physical examination and fine needle aspiration biopsy. So the differential diagnosis is dependent on the age of the patient, and therefore in the patient over the 40 years of age, the possibility of a metastatic neck mass should be considered. We report a metastatic cystic neck mass which had been misdiagnosed as a branchial cleft cyst.

  • PDF

Effect of Head of the Line Blocking on Session Initiation Protocol Session Establishment Delays

  • Camarillo, Gonzalo;Schulzrinne, Henning;Loreto, Salvatore;Hautakorpi, Jani
    • Journal of Communications and Networks
    • /
    • v.11 no.1
    • /
    • pp.72-83
    • /
    • 2009
  • We have studied the effect of head of the line blocking (HOLB) on session initiation protocol (SIP) session establishment delays. Our results are based on experiments performed in a test bed and on the public Internet. We used the stream control transmission protocol (SCTP) as a transport for SIP because SCTP can be configured to suffer or to avoid HOLB. Our experiments show that the effect of HOLB on session establishment delays generally starts to be significant starting at fairly low packet loss rates. However, there are scenarios where network conditions are good enough to make the effect of HOLB insignificant.

Adulthood Benign Triton Tumor Developed in the Orbit

  • Bae, Dong Hyeon;Kim, Choong Hyun;Cheong, Jin Hwan;Kim, Jae Min
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.2
    • /
    • pp.146-148
    • /
    • 2014
  • Benign triton tumor (BTT) or neuromuscular hamartoma is an uncommon tumor composed of mature neural and well-differentiated striated muscular elements. Its development is exceptionally rare in the adult and head region. This report describes a case of adulthood BTT that occurred in the orbit. The patient was a 53-year-old woman who presented with right periorbital swelling and pain in eyeball over 2 months. Magnetic resonance imaging revealed a well-enhancing mass surrounding optic nerve and ocular muscles in the right retrobulbar area. The tumor was subtotally removed via transcranial approach. Its pathological diagnosis was confirmed to be a neuromuscular hamartoma. She developed diplopia postoperatively. Adulthood BTT should be considered in the differential diagnosis of head and neck tumors. It is also important to make adequate therapeutic strategy to avoid postoperative neural dysfunction.

Experimental Study on Adjustment of Inlet Nozzle Section to Flow Rate Variation for Darrieus-type Hydro-Turbine

  • Watanabe, Satoshi;Shimokawa, Kai;Furukawa, Akinori;Okuma, Kusuo;Matsushita, Daisuke
    • International Journal of Fluid Machinery and Systems
    • /
    • v.5 no.1
    • /
    • pp.30-37
    • /
    • 2012
  • A two dimensional Darrieus-type turbine has been proposed for the hydropower utilization of extra-low head less than 2m. In a practical use of Darrieus-type hydro-turbine, head and flow rate may be varied temporally and seasonally. Considering that the cost advantage is required for the low head hydro turbine system, the Darrieus turbine should be operated with high efficiency in the wider range of flow rate possibly by using an additional device with simpler mechanism. In the present paper, an adjustment of inlet nozzle section by lowering the inlet nozzle height is proposed to obtain the preferable inlet velocity in low flow rate conditions. Effects of resulting spanwise partial inlet flow are investigated. Finally, an effective modification of inlet nozzle height over flow rate variation is shown.

Settling time of dental x-ray tube head after positioning (치과용 X-선 관구의 조정시간)

  • Yoon Suk-Ja;Kang Byung-Cheol;Wang Se-Myung;Koh Chang-Sung
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.159-165
    • /
    • 2002
  • Purpose: The aim of this study was to introduce a method of obtaining the oscillation graphs of the dental x-ray tube heads relative to time using an accelerometer. Materials and Methods: An Accelerometer, Piezotron type 8704B25 (Kistler Instrument Co., Amherst, NY, USA) was utilized to measure the horizontal oscillation of the x-ray tube head immediately after positioning the tube head for an intraoral radiograph. The signal from the sensor was transferred to a dynamic signal analyzer, which displayed the magnitude of the acceleration on the Y-axis and time lapse on the X -axis. The horizontal oscillation of the tube head was measured relative to time, and the settling time was also determined on the basis of the acceleration graphs for 6 wall type, 5 floor-fixed type, and 4 mobile type dental x-ray machines. Results : The oscillation graphs showed that tube head movement decreased rapidly over time. The settling time varied with x-ray machine types. Wall-type x-ray machines had a settling time of up to 6 seconds, 5 seconds for fixed floor-types, and 1 I seconds for the mobile-types. Conclusion: Using an accelerometer, we obtained the oscillation graphs of the dental x-ray tube head relative to time. The oscillation graph with time can guide the operator to decide upon the optimum exposure moment after x-ray tube head positioning for better radiographic resolution.

  • PDF