• 제목/요약/키워드: Over the top

검색결과 1,203건 처리시간 0.036초

후향단유동내 경계층의 재발달에 미치는 경계조건의 영향 (Effects of Boundary Conditions on Redevelopment of the Boundary Layer in a Backward-Facing Step Flow)

  • 김동일;이문주;전중환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.506-511
    • /
    • 2001
  • This paper presents how redevelopment of the boundary layer in a backward-facing step flow is affected by boundary conditions imposed on velocity at the inlet, top and exit of the flow. A two-dimensional, laminar, incompressible flow over a backward-facing step with an open top boundary has been computed by using numerical methods of second-order time and spatial accuracy and a fractional-step method that guarantees a divergence-free velocity field at all time. The inlet velocity profile above the step is of Blasius type. Along the top boundary, shear-tree and Dirichlet conditions on the streamwise velocity were considered and at the exit fully-developed and convective boundary conditions were examined. (The vertical velocity at all boundaries were assumed to be zero explicitly or implicitly.) From the computed flow fields, the reattachment on the bottom side of shear layer separated from the tip of the step and succeeding redevelopment of the boundary layer were investigated.

  • PDF

외부 입력기기 사용 정보 기반 셋톱박스 대기모드 전환 기술 (A Standby Mode Transition Scheme for Set-top Box Power Saving by the Use Information of External Device)

  • 김용호;최윤범;오남걸;김훈
    • 정보통신설비학회논문지
    • /
    • 제9권4호
    • /
    • pp.124-130
    • /
    • 2010
  • This paper considers a power saving technique of set-top box (STB) that turns the signal into content which is then displayed on the television (TV) screen. A traditional power saving scheme, Auto Power Down (APD), was devised to reduce the power consumption of STB. APD checks whether the user is watching TV over a period of time and enforces STB into stand-by mode when the check result reveals the user is not watching TV. This paper proposes an enhanced power saving scheme that transits STB operation mode to 'stand-by' immediately when STB recognizes the change of TV's external input signal. The proposed scheme does not require the monitoring time to check the users' watching TV, and transits to standby mode faster than the conventional APD, which results in better performance in power saving. The simulation result shows that the proposed scheme achieves 2 to 11% improvement in power consumption compared with the conventional APD.

  • PDF

Practical modeling and quantification of a single-top fire events probabilistic safety assessment model

  • Dae Il Kang;Yong Hun Jung
    • Nuclear Engineering and Technology
    • /
    • 제55권6호
    • /
    • pp.2263-2275
    • /
    • 2023
  • In general, an internal fire events probabilistic safety assessment (PSA) model is quantified by modifying the pre-existing internal event PSA model. Because many pieces of equipment or cables can be damaged by a fire, a single fire event can lead to multiple internal events PSA initiating events (IEs). Consequently, when the fire events PSA model is quantified, inappropriate minimal cut sets (MCSs), such as duplicate MCSs, may be generated. This paper shows that single quantification of a hypothetical single-top fire event PSA model may generate the following four types of inappropriate MCSs: duplicate MCSs, MCSs subsumed by other MCSs, nonsense MCSs, and MCSs with over-counted fire frequencies. Among the inappropriate MCSs, the nonsense MCSs should be addressed first because they can interfere with the right interpretation of the other MCSs and prevent the resolution of the issues related to the other inappropriate MCSs. In addition, we propose a resolution process for each of the issues caused by these inappropriate MCSs and suggest an overall procedure for resolving them. The results of this study will contribute to the understanding and resolution of the inappropriate MCSs that may appear in the quantification of fire events PSA models.

Improvement of Strain and Elastic Modulus of Linerboard to Prevent Score Crack

  • Chin, Seong-Min;Choi, Ik-Sun;Lee, Hak-Lae;Youn, Hye-Jung
    • 펄프종이기술
    • /
    • 제42권5호
    • /
    • pp.31-36
    • /
    • 2010
  • When corrugated board is folded at the severely low humidity condition, crack can occur along the scored (or creased) lines of linerboard. This phenomenon is called as score (or crease) crack. It is mainly resulted from the excessive concentration of stress on the outer layer of linerboard. To overcome score crack, many approaches including the installation of constant temperature and humidity system, displacement of low grade raw material by long and strong fibers, or application of water have been tried. We examined the effect of the weight fraction of top layer in two-ply sheet, freeness of top layer stock and wet pressing on strain and elastic modulus of sheet to prevent score crack. Lower freeness and higher press load increased the density and elastic modulus of sheet. Pressing load over the $50kgf/cm^2$, however, decreased the strain of sheet. The weight fraction of top layer had positive effect on strain as well as elastic modulus without increasing the density of sheet.

SAFETY MANAGEMENT ON CONSTRUCTION MANAGEMENT: A CASE STUDY REVIEW

  • Eric Chan
    • 국제학술발표논문집
    • /
    • The 4th International Conference on Construction Engineering and Project Management Organized by the University of New South Wales
    • /
    • pp.249-255
    • /
    • 2011
  • Poor safety management in construction management may adversely affect cost, schedule and quality of a project. Heavy fines upon safety offence becomes a burden to the budget; losing working hours as a result of safety incident impacts on the schedule, and compromising quality is always an indirect consequence when workers perform duties in an unsafe site environment. Therefore, promotion of safety management becomes the top priority in any construction manager's agenda. Working safely will benefit construction project and lead to a "real" success. This paper is a case study, based upon "Geller's 10 principles for achieving a total safety culture", reviewing how a Hong Kong leading construction company fosters the safety culture and possesses a pleasant safety record over years. Its safety performance is not only well ahead the local industry, but also ranges top within the Asia Pacific region and comparable to those mature Western industries. The review concluded that safety culture is one of the major components in construction management and collaboration is the essence to realize this positive culture within an organization. Safety management is not merely a "top down" approach, but requires the positive "bottom up" actions from the other end. The successful story of this company can demonstrate the contribution of safety management in construction management.

  • PDF

Self-healing Anticorrosion Coatings for Gas Pipelines and Storage Tanks

  • Luckachan, G.E.;Mittal, V.
    • Corrosion Science and Technology
    • /
    • 제15권5호
    • /
    • pp.209-216
    • /
    • 2016
  • In the present study, chitosan based self-healing anticorrosion coatings were prepared by layer by layer (lbl) addition of chitosan (Ch) and polyvinyl butyral (PVB) on mild carbon steel substrate. Chitosan coatings exhibited enhanced coating stability and corrosion resistance in aggressive environments by the application of a PVB top layer. Chitosan layer in the lbl coatings have been modified by using glutaraldehyde (Glu) and silica ($SiO_2$). Performance of different coatings was tested using electrochemical impedance spectroscopy and immersion test. The best anticorrosion performance was observed in case of 10 % Ch_$SiO_2$_PVB coatings, which withstand immersion test over 25 days in 0.5 M salt solution without visible corrosion. 10 % Ch_$SiO_2$ coatings without the PVB top layer didn't last more than 3days. Application of PVB top layer sealed the defects in the chitosan pre-layer and improved its hydrophobic nature as well. Raman spectra and SEM of steel surfaces after corrosion study and removal of PVB_Ch/Glu_PVB coatings showed a passive layer of iron oxide, attributing to the self-healing nature of these coatings. Conducting particle like graphene reinforcement of chitosan in the lbl coatings enhanced corrosion resistance of chitosan coatings.

도시형자기부상열차 열차제어시스템 RAMS 분석에 관한 연구 (A Study on the RAMS Analysis of Urban Maglev Train Control System)

  • 윤학선;이기서;류승균;양동인
    • 한국철도학회논문집
    • /
    • 제14권6호
    • /
    • pp.515-525
    • /
    • 2011
  • 도시형 자기부상열차 실용화사업에 적용된 유도무선루프방식 열차제어시스템에 대하여 최상위 레벨에서 전체 시스템에 대한 시스템 분류, 기능 분석을 시행하고 차상신호설비, 지상신호설비로 나누어 신뢰도, 가용도, 유지보수도 및 안전도를 수식을 통하여 분석한 결과를 제시하였다. RAM 분석은 신뢰도 블록도(RBD)를 각 장치별로 적용하여 시스템 서비스 가용도를 산출하였고, 안전도 분석은 PHA(예비위험원 분석), FMEA (고장모드영향분석), HAZOP을 통한 각각의 정상사상(Top Event)의 FTA(고장트리분석)을 시행하고 그 결과를 제시하여 RAMS 목표 값에 도달함을 수식을 통하여 증명하였다.

Effects of Volatile Solid Concentration and Mixing Ratio on Hydrogen Production by Co-Digesting Molasses Wastewater and Sewage Sludge

  • Lee, Jung-Yeol;Wee, Daehyun;Cho, Kyung-Suk
    • Journal of Microbiology and Biotechnology
    • /
    • 제24권11호
    • /
    • pp.1542-1550
    • /
    • 2014
  • Co-digesting molasses wastewater and sewage sludge was evaluated for hydrogen production by response surface methodology (RSM). Batch experiments in accordance with various dilution ratios (40- to 5-fold) and waste mixing composition ratios (100:0, 80:20, 60:40, 40:60, 20:80, and 0:100, on a volume basis) were conducted. Volatile solid (VS) concentration strongly affected the hydrogen production rate and yield compared with the waste mixing ratio. The specific hydrogen production rate was predicted to be optimal when the VS concentration ranged from 10 to 12 g/l at all the mixing ratios of molasses wastewater and sewage sludge. A hydrogen yield of over 50 ml $H_2/gVS_{removed}$ was obtained from mixed waste of 10% sewage sludge and 10 g/l VS (about 10-fold dilution ratio). The optimal chemical oxygen demand/total nitrogen ratio for co-digesting molasses wastewater and sewage sludge was between 250 and 300 with a hydrogen yield above 20 ml $H_2/gVS_{removed}$.

전면 발광 유기 발광 소자용 반투명 금속의 전기적 및 광학적 특성 (Electrical and Optical Properties of Semitransparent Metal Electrodes for Top-emission Organic Light-emitting Diodes)

  • 신은철;안희철;김태완
    • 한국전기전자재료학회논문지
    • /
    • 제21권10호
    • /
    • pp.938-942
    • /
    • 2008
  • Electrical and optical properties of semitransparent Ag and Al layer were studied, which are used for the electrodes in top-emission organic light-emitting diodes. Sheet resistance and transmittance of visible light through a thin layer were measured and analyzed. Several thin metal layers of Ag and Al were deposited onto a glass substrate up to a thickness of 50 nm using a thermal evaporation. Sheet resistance measurements show that a layer thickness is needed more than 15 nm and 20 nm for Ag and Al, respectively, when a proper sheet resistance is assumed to be less than $50{\Omega}/sq$. From the measurements of transmittance of visible light through a thin-metal layer, metallic behavior was observed when the layer thickness is over 25 nm for both films. Thus, from a study of sheet resistance and transmittance of visible light, a minimum proper thickness of semitransparent metal layer is 20 nm and 25 nm for Ag and Al, respectively.

헬리코박터 파일로리에서 fdxA 유전자에 의한 메트로니다졸 내성 조절 기전 연구 (Mechanism of Metronidazole Resistance Regulated by the fdxA Gene in Helicobacter pylori.)

  • 남원희;이선미;김은실;김진호;정진용
    • 생명과학회지
    • /
    • 제17권5호
    • /
    • pp.723-727
    • /
    • 2007
  • 본 연구는 H. pylori에서 metronidazole내성에 관여하는 유전자를 발견하고 이들 유전자들의 상호 조절 기전을 밝힘으로서 위장질환의 원인균인 H. pylori를 퇴치하기 위한 기본바탕을 마련하고자 수행되었다. 우선적으로 metronidazole 내성을 조절하는 유전자인 fdxA(ferredoxin)에 의한 metronidazole 내성 조절 기전을 밝히기 위하여 다음의 연구를 수행하였다. Type I 균주인 26695균주의 fdxA 유전자에 chloramphenicol 내성 유전자를 삽입하여 결손돌연변이주를 구축하였다. fdxA의 비활성화에 의한 rdxA 및 frxA 유전자의 발현을 알아보기 위하여 2-D electrophoresis와 MALDI-TOP-MS을 이용하여 fdxA 유전자의 비활성화에 의해 over-expressed protein과 under-expressed protein을 검색하였다. 본 실험의 결과로 type I 균주인 26695에서 fdxA 유전자를 비활성화시킨 결과 frxA 유전자의 발현양이 증가함을 northern으로 확인하였으며, 또한 fdxA유전자의 downstream에 위치한 유전자들이 H. pylori의 생존에 중요한 역할은 한다는 것을 알 수 있었다. 또한 2-D electrophoresis와 MALDI-TOP-MS을 이용하여 fdxA 유전자의 inactivation에 의해 over-expressed protein으로 nifU-like protein(HP0221), frxA(HP0642), nonheme ferritin(HP0653)와 아직 기능이 밝혀지지 않은 hypothetical protein(HP0902) 등이 발견되었다. 그리고 5'-methylthioadenosine/S-adenosylhomocysteine nucleosidase(HP0089), (3R)-hydroxymyristoyl ACP dehydratase(HP1376)과 thioredoxin(HP1458)등이 under-expressed protein으로 발견되었다.