• 제목/요약/키워드: Over discharge

Search Result 937, Processing Time 0.028 seconds

Relationship between Psychosocial Factors and Symptom Experience in Patients with Cardiovascular Disease: Over a Six-month follow-up Period (심장질환자의 심리사회적 요인 및 증상 경험간의 관계 : 6개월 추적조사)

  • Kim Cho-Ja;Kim Gi-Yon;Roh Young-Sook;Song Eun-Kyeung;Kang Seok-Min;Yoo Myung-Sook;Son Youn-Jung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.13 no.1
    • /
    • pp.76-85
    • /
    • 2006
  • Purpose: The purpose of this study was to identify the relationship between psychosocial factors and symptom experience of patients with cardiovascular disease over a 6-month follow-up period. Method: Baseline data for each of the 138 patients were collected. Eighteen patients were dropped for a final total of 120 patients in the present study. To monitor patients' symptom experience after discharge, each patient was interviewed by telephone, and interviewed directly with a questionnaire at each clinic visit. Results: Mean scores for hostility, anger, anxiety, and depression were 51.63, 22.87, 48.95, and 41.21, respectively. Mean scores for the level of symptom experience at discharge, 3 months and 6 months after discharge were 32.83, 24.79, and 26.70, respectively. There were significant differences in the level of hostility by gender, BMI, job, and monthly income. Also the differences in the level of anxiety and depression were statistically significant according to gender and existence of spouse. In the regression analysis, depression was identified as the significant factor associated with symptom experience at discharge, 3 months, and 6 months after discharge. Conclusion: This study presented baseline data to elucidate whether psychosocial factors were associated with the progression of cardiovascular diseases. Accordingly, it suggests that nurses need to take into consideration psychosocial factor as well as physiological factor in symptom management for patients with cardiovascular disease.

  • PDF

Effects of a Gelatin Coating on the Shelf Life of Salmon

  • Heu, Min-Soo;Park, Chan-Ho;Kim, Hyung-Jun;Lee, Dong-Ho;Kim, Jin-Soo
    • Fisheries and Aquatic Sciences
    • /
    • v.13 no.2
    • /
    • pp.89-95
    • /
    • 2010
  • This study was conducted to investigate the efficacy of using a coating of gelatin extracted from refiner discharge to extend the shelf life of salmon during cold storage ($5^{\circ}C$). Relative percentage of moisture loss in gelatin-coated salmon during cold storage was less than that of uncoated salmon. The treatment of salmon with gelatin reduced volatile basic nitrogen (VBN) formation throughout the entire storage period. Measurements of the peroxide value (POV), fatty acid composition, and (20:5n-3+22:6n-3)/16:0 ratio during cold storage indicated that the coating of salmon with gelatin from refiner discharge effectively suppressed lipid oxidation over the entire storage period. The extent of sensory color change during cold storage was less in the gelatin-coated than in the uncoated salmon. From the results of chemical measurements, such as relative moisture content, VBN, POV, fatty acid composition, (20:5n-3+22:6n-3)/16:0 ratio, and sensory color change, the conclusion was made that the coating treatment of salmon with refiner discharge gelatin effectively suppressed moisture loss, lipid oxidation, and color deterioration over the entire storage period.

Evaluation of Channel-forming Discharge for the Abandoned Channel Restoration Design of Cheongmi Stream (청미천 구하도 복원 설계를 위한 하도형성유량 산정)

  • Ji, Un;Kang, Jun-Gu;Yeo, Woon-Kwang;Han, Seung-Won
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.12
    • /
    • pp.1113-1124
    • /
    • 2009
  • The abandoned channel restoration is one of methods to enhance the environmental function and ecological habitat as well as the functions of water-utilization and flood control. The channel-forming or dominant discharge must be evaluated and defined to design the cross-sectional and plane geometries of the stable and equilibrium channel for the abandoned channel restoration project. In general, bankfull discharge, specified recurrence interval discharge, and effective discharge have been used to decide the channel-forming discharge. In this study, bankfull discharge, specified recurrence interval discharge, and effective discharge were calculated and compared for the abandoned channel restoration site of Cheongmi Stream and their relations to historical bed changes were analyzed. The bankfull discharge, 488 $m^3/s$, of the abandoned channel restoration site of Cheongmi Stream was calculated using HEC-RAS data and ranged between 1.5-year and 2-year recurrence discharges. Also, the effective discharge evaluated with the sediment rating curve and mean daily discharge data is greater than the bankfull discharge. According to the survey data of 1994 and 2008, the bed elevation of the study reach was decreased over time. It is indicated that the channel bed is changing to the stable condition to allow the effective discharge.

Derivation of the Synthetic Unit Hydrograph Based on the Watershed Characteristics (유역특성에 의한 합성단위도의 유도에 관한 연구)

  • 서승덕
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.1
    • /
    • pp.3642-3654
    • /
    • 1975
  • The purpose of this thesis is to derive a unit hydrograph which may be applied to the ungaged watershed area from the relations between directly measurable unitgraph properties such as peak discharge(qp), time to peak discharge (Tp), and lag time (Lg) and watershed characteristics such as river length(L) from the given station to the upstream limits of the watershed area in km, river length from station to centroid of gravity of the watershed area in km (Lca), and main stream slope in meter per km (S). Other procedure based on routing a time-area diagram through catchment storage named Instantaneous Unit Hydrograph(IUH). Dimensionless unitgraph also analysed in brief. The basic data (1969 to 1973) used in these studies are 9 recording level gages and rating curves, 41 rain gages and pluviographs, and 40 observed unitgraphs through the 9 sub watersheds in Nak Oong River basin. The results summarized in these studies are as follows; 1. Time in hour from start of rise to peak rate (Tp) generally occured at the position of 0.3Tb (time base of hydrograph) with some indication of higher values for larger watershed. The base flow is comparelatively higher than the other small watershed area. 2. Te losses from rainfall were divided into initial loss and continuing loss. Initial loss may be defined as that portion of storm rainfall which is intercepted by vegetation, held in deppression storage or infiltrated at a high rate early in the storm and continuing loss is defined as the loss which continues at a constant rate throughout the duration of the storm after the initial loss has been satisfied. Tis continuing loss approximates the nearly constant rate of infiltration (${\Phi}$-index method). The loss rate from this analysis was estimated 50 Per cent to the rainfall excess approximately during the surface runoff occured. 3. Stream slope seems approximate, as is usual, to consider the mainstreamonly, not giving any specific consideration to tributary. It is desirable to develop a single measure of slope that is representative of the who1e stream. The mean slope of channel increment in 1 meter per 200 meters and 1 meter per 1400 meters were defined at Gazang and Jindong respectively. It is considered that the slopes are low slightly in the light of other river studies. Flood concentration rate might slightly be low in the Nak Dong river basin. 4. It found that the watershed lag (Lg, hrs) could be expressed by Lg=0.253 (L.Lca)0.4171 The product L.Lca is a measure of the size and shape of the watershed. For the logarithms, the correlation coefficient for Lg was 0.97 which defined that Lg is closely related with the watershed characteristics, L and Lca. 5. Expression for basin might be expected to take form containing theslope as {{{{ { L}_{g }=0.545 {( { L. { L}_{ca } } over { SQRT {s} } ) }^{0.346 } }}}} For the logarithms, the correlation coefficient for Lg was 0.97 which defined that Lg is closely related with the basin characteristics too. It should be needed to take care of analysis which relating to the mean slopes 6. Peak discharge per unit area of unitgraph for standard duration tr, ㎥/sec/$\textrm{km}^2$, was given by qp=10-0.52-0.0184Lg with a indication of lower values for watershed contrary to the higher lag time. For the logarithms, the correlation coefficient qp was 0.998 which defined high sign ificance. The peak discharge of the unitgraph for an area could therefore be expected to take the from Qp=qp. A(㎥/sec). 7. Using the unitgraph parameter Lg, the base length of the unitgraph, in days, was adopted as {{{{ {T}_{b } =0.73+2.073( { { L}_{g } } over {24 } )}}}} with high significant correlation coefficient, 0.92. The constant of the above equation are fixed by the procedure used to separate base flow from direct runoff. 8. The width W75 of the unitgraph at discharge equal to 75 per cent of the peak discharge, in hours and the width W50 at discharge equal to 50 Per cent of the peak discharge in hours, can be estimated from {{{{ { W}_{75 }= { 1.61} over { { q}_{b } ^{1.05 } } }}}} and {{{{ { W}_{50 }= { 2.5} over { { q}_{b } ^{1.05 } } }}}} respectively. This provides supplementary guide for sketching the unitgraph. 9. Above equations define the three factors necessary to construct the unitgraph for duration tr. For the duration tR, the lag is LgR=Lg+0.2(tR-tr) and this modified lag, LgRis used in qp and Tb It the tr happens to be equal to or close to tR, further assume qpR=qp. 10. Triangular hydrograph is a dimensionless unitgraph prepared from the 40 unitgraphs. The equation is shown as {{{{ { q}_{p } = { K.A.Q} over { { T}_{p } } }}}} or {{{{ { q}_{p } = { 0.21A.Q} over { { T}_{p } } }}}} The constant 0.21 is defined to Nak Dong River basin. 11. The base length of the time-area diagram for the IUH routing is {{{{C=0.9 {( { L. { L}_{ca } } over { SQRT { s} } ) }^{1/3 } }}}}. Correlation coefficient for C was 0.983 which defined a high significance. The base length of the T-AD was set to equal the time from the midpoint of rain fall excess to the point of contraflexure. The constant K, derived in this studies is K=8.32+0.0213 {{{{ { L} over { SQRT { s} } }}}} with correlation coefficient, 0.964. 12. In the light of the results analysed in these studies, average errors in the peak discharge of the Synthetic unitgraph, Triangular unitgraph, and IUH were estimated as 2.2, 7.7 and 6.4 per cent respectively to the peak of observed average unitgraph. Each ordinate of the Synthetic unitgraph was approached closely to the observed one.

  • PDF

Discharge Coefficient of Side Weir for Various Curvatures Simulated by FLOW-3D (FLOW-3D를 이용한 다양한 곡률에 대한 횡월류 위어의 유량계수 산정)

  • Jeong, Chang Sam
    • Journal of Korean Society of Disaster and Security
    • /
    • v.8 no.1
    • /
    • pp.5-13
    • /
    • 2015
  • In this study, the lateral overflow discharge coefficients for the curvatures of side weir on meandering channel were analyzed. The side weir installed in accordance with the variation of the radius of curvature of the central angle bends with $180^{\circ}$. FLOW-3D model is applied to calculate the discharge coefficients of the side-weir on meandering and straight channels and the characteristics of the discharge coefficients are analysed. In order to verify the numerical model, the results from the hydraulic experiment conducted by the former research are compared with the results simulated by FLOW-3D in the same conditions. The discharge coefficients are calculated for the ratio between curvature ($R_c$) and channel width (b), and the ratio between over flow discharge of the straight channel ($Q_{wc}$) and the meandering channel ($Q_{wc}$) are compared. As the result, the discharge coefficients depend on the weir depth on upstream, and the radius of curvature, so that the discharge coefficients of side weir on the meandering channel can be estimated by them on the straight channel.

A Assessment of Discharge Capacity of Vertical Drains and Smear Zone Effect from Model Test (실내모형시험을 통한 연직배수재의 통수능력 및 스미어존 영향 평가)

  • Chun, Byung-Sik;Kim, Eui-Seok;Do, Jong-Nam;Kuk, Kil-Keun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1136-1143
    • /
    • 2008
  • The Vertical Drains(Sand Drains, Pack Drain, PBD) is used for Vertical Drains Method in domestic. Each of the drains is selected after it consider a field condition and efficiency of drain. A discharge capacity is very important factor, which to estimate a efficiency. And the smear Zone where disturbance area of in-suit by installation of Vertical Drains is important factor to select a drains. In this study, the complex discharge capacity test was operated for discharge capacity comparison of the Wing Drain and PBD. And a model test was operated to apprehend smear zone of the Wing Drain and PBD. From these tests, it was apprehended an engineering characteristic of vertical drain. The results of the complex discharge capacity test, a discharge capacity fell below $20cm^3/sec$ to $1cm^3/sec$ in more than overburden load $2.5kg/cm^2$. The Wing Drain maintained a over $40cm^3/sec$ in more than overburden load $2.5kg/cm^2$ and minimum discharge capacity $8cm^3/sec$. The results of the smear zone test, a influence bounds of smear zone was more larger in case of the Wing Drain(rectangle) than the PBD. But when a discharge capacity of Wing Drain is considered, it was concluded which smear zone bounds difference was effected in comparison with PBD. I think that it minimized a mandrel section to minimize a smear zone effect range

  • PDF

Nano Particle Precipitation and Residual Ozone Decomposition of a Hybrid Air Cleaning System Comprising Dielectric Barrier Discharge Plasma and MnO2 Catalyst or Activated Carbon (활성탄 또는 촉매가 장착된 배리어 유전체 방전 하이브리드. 공기청정 시스템의 나노입자 및 잔류 오존 제거 특성)

  • Byeon, Jeong-Hoon;Hwang, Jung-Ho;Ji, Jun-Ho;Kang, Suk-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.4
    • /
    • pp.524-533
    • /
    • 2003
  • DBD(Dielectric Barrier Discharge) plasma in air is well established for the production of large quantities of ozone and is more recently being applied to aftertreatment processes for HAPs(Hazardous Air Pollutants). Aim of this work is to determine design and operating parameters of a hybrid air cleaning system. DBD and ESP(Electrostatic Precipitator) are used as nano particle charger and collector, respectively. Pelletized MnO$_2$ catalyst or activated carbon is used fer ozone decomposition or adsorption material. AC voltage of 7~10 KV(rms) and 60 Hz is used as DBD plasma source. DC - 8 KV is applied to the ESP for particle collection. The overall particle collection efficiency for the hybrid system is over 85 % under 0.64 m/s face velocity. Ozone decomposition efficiency with pelletized MnO$_2$ catalyst or activated carbon packed bed is over 90 % when the face velocity is under 0.4 m/s in dry air.

Analysis of Charge and Discharge Characteristics of Heavy Duty Electric Commercial Vehicle Batteries (중대형 전기 상용차 배터리의 주행중 충방전 특성 분석)

  • Song, Jingeun;Cha, Junepyo
    • Journal of Institute of Convergence Technology
    • /
    • v.11 no.1
    • /
    • pp.19-23
    • /
    • 2021
  • These days, sales of battery electric vehicles have been rapidly increasing due to the strict CO2 regulations. However, since it take too long to measure the energy economy of electric vehicles, it has been required to improve the procedure of energy economy measurement. In order to improve this problem, the present study analyzed the battery charge/discharge pattern according to the changes in battery SOC (state of charge). In general, the energy economy test is started with a battery SOC charged to 100 %. However, it was identified that when the battery is fully charged, it can actually be charged over the 100 % (e.g., 100.5 %). This can induce errors in the energy economy measurement. Therefore, the present study recommend to start the test at SOC 99.9 %. The regenerative braking was partly restricted for the SOC over 90 %. This made it difficult to estimate the overall energy economy of the electric vehicle. However, it was identified that there was no change in the battery charge/discharge characteristics under the SOC 90 %. Therefore, the energy economy test can be shortened by predicting the overall energy economy through a short mileage test.

Transitions between Uncontrolled Submerged and Uncontrolled Free in Low-Head Ogee Spillway

  • Hong, Seung Ho;Hong, Da Hee;Song, Yang Heon;Lee, Jeong Myeong;Jegal, Jin A
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.155-155
    • /
    • 2022
  • Low head, ogee spillways is popularly used to defense against floods as well as to provide water for irrigation. Spillway is also used to assess compliance with water quality regulations by controlling amount of discharge to the downstream of a channel. For the purpose of water resource management and/or environmental aspects as explained above, the flow discharge through spillways need to be correctly rated as a function of geometry and hydraulic variables. Typically, four flow conditions are encountered during the operation of spillway: (a) uncontrolled free flow (UF); (b) uncontrolled submerged flow (US); controlled free flow (CF); and controlled submerged flow (CS), and each condition has a unique rating equation. However, one of the tricky part of the spillway operation is finding correct flow type over the spillway because structures can operate under both submerged and free flow conditions, and the types are continuously changing over time depending on the amount of discharge, head water and tail water elevation. Quite obviously, if the wrong rating curve relationship is applied because of misjudgment of the flow type due to a transition, a serious error can occur. Thus, an hydraulic model study of one of spillway structure located in South Florida was conducted for the purpose of developing transition relationships. In this presentation, US to UF transition is highlighted.

  • PDF

Research and Development of High Luminous Efficacy Plasma Displays

  • Kosugi, Naoki;Akiyama, Toshiyuki;Kitagawa, Masatoshi;Shinodaq, Tsutae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.57-60
    • /
    • 2008
  • Over 5lm/W white luminous efficacy was obtained by 11" color test panel with narrowed discharge electrodes combined with high Xe partial pressure. By using optical spectroscopic methods, it was suggested that the electron heating efficiency is the most significant to improve the plasma efficiency in our experimental conditions.

  • PDF