• 제목/요약/키워드: Over current protection

검색결과 289건 처리시간 0.033초

$Y-{\Delta}$ 변압기 보호용 수정 전류차동 계전기 (Modified Current Differential Relay for $Y-{\Delta}$ Transformer Protection)

  • 김은숙;강용철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권3호
    • /
    • pp.95-101
    • /
    • 2006
  • This paper proposes a modified current differential relay for $Y-{\Delta}$ transformer protection. The relay uses the same restraining current as a conventional relay, but the differential current is modified to compensate for the effects of the exciting current. A method to estimate the circulating component of the delta winding current is proposed. To cope with the remanent flux, before saturation, the core-loss current is calculated and used to modify the measured differential current. When the core then enters saturation, the initial value of the flux is obtained by inserting the modified differential current at the start of saturation into the magnetization cure. Thereafter, the core flux is then derived and used in conjunction with the magnetization curve to calculate the magnetizing current. A modified differential current is then derived that compensates for the core-loss and magnetizing currents. The performance of the proposed differential relay was compared against a conventional differential relay. Test results indicate that the modified relay remained stable during severe magnetic inrush and over-excitation, because the exciting current was successfully compensated. This paper concludes by implementing the relay on a hardware platform based on a digital signal processor. The relay does not require additional restraining signal and thus cause time delay of the relay.

유도전동기 자가 진단 및 상수 추정을 위한 고주파 전류 제어기 구현 (Implementation of High Frequency Current Controller for Self-Sensing Induction Motors)

  • 권영수;석줄기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.144-146
    • /
    • 2007
  • High frequency voltage signal injection have been widely used but they have some problems like over current protection. High frequency current signal injection and feedback control are more stable than voltage signal injection. In this paper, high frequency current controller for self-sensing and parameter estimation of induction motors is presented.

  • PDF

분산전원이 연계된 배전계통에서 보호협조기기의 운용특성에 관한 연구 (Operating Characteristics of Protection Coordination Devices in Distribution System interconnected with Distributed Generation)

  • 김소희;지성호;김선영;노대석
    • 한국융합학회논문지
    • /
    • 제2권2호
    • /
    • pp.35-45
    • /
    • 2011
  • 최근 정부의 녹색성장 정책에 의해 배전계통에 태양광, 풍력발전 등과 같은 분산전원의 보급률이 지속적으로 증가되고 있는 실정이다. 이러한 분산전원의 설치가 급증함에 따라 기존 배전계통의 조류흐름은 단방향(One-direction)에서 양방향(Bi-direction)으로 변화되고 고장전류의 증 감이 발생하는 등, 다양한 변화가 생겨 배전계통의 운용상에 여러 가지 문제점들이 발생할 가능성이 커지고 있다. 따라서 본 논문에서는 분산전원의 배전계통 연계에 따른 보호기기의 정정 및 양방향 보호협조검토가 가능한 보호협조 평가알고리즘을 제안하고, 그 알고리즘을 바탕으로 양방향 보호협조 평가시스템을 제작하였다. 또한 평가시스템을 이용하여 배전계통을 모델링하고 분산전원 연계 시 보호기기들 사이의 보호협조를 검토하여, 분산전원이 연계된 경우 배전계통에 발생할 수 있는 기술적인 문제점들을 분석하여 그 방안을 제시하였다.

ICCP Control and Monitoring System for Ships

  • Oh, Jin-Seok;Moon, Serng-Bae
    • 한국항해항만학회지
    • /
    • 제30권4호
    • /
    • pp.291-294
    • /
    • 2006
  • Corrosion is never avoided in the use rf materials with various environments. The underwater hull is normally protected against rusting by several coatings of anti-corrosive paint. The purpose of ICCP(Impressed Current Cathodic Protection) system is to eliminate the rusting or corrosion, which occurs on metal immersed in seawater. This thesis is about the ICCP control and monitoring system, which brings protection against the corrosion of the ship's hull in the sea environments. The test system for ICCP is composed of a power supply, anode, reference electrode and controller. The test system is composed power supply, anode, ref electrode, shunt and etc. The protection current is sent to the protection area though anode. Reference electrode senses whether or not the detected potential is within a range of protection of test equipment and then it is automatically controlled to increase or decrease the amount of protective current to be sent to the anode by controller. The monitoring system with LabView is also detected in order to check the normal state of the system at operation period, because an operator does not always watch over this system and thus the system cannot operate well because rf his or her negligent management. This paper was studied the variation of potential and current density with environment factors, velocity and time, and the experimental results will be explained Also, It is suggested that this system can accommodate a ship's automation for SCMS(Ship Control and Management System) and will be very useful.

정전류 제어가 가능한 100W급 초박형 DC-DC 컨버터 (100W Class Low Profile DC-DC Converter with Constant Current Control)

  • 연제선;안태영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.713-717
    • /
    • 2004
  • This is a thesis that a quarter-brick size of 100W class open-frame type on board power module comprising telecommunication application is reported. The input voltage is established between 36 and 75 in range in order for power module to be utilized for the telecommunication application, and output were set at 3.3V and 30A. A number of parts used for transformer, inductor, and hit sink are composed of PCB in order for DC-DC converter to be lowered below 8 mm. A constant current control circuit was annexed to the system as well as basic protection prototypes such as over-voltage, over-current, and over-temperature were well considered to enhance more credibility, and were tested. As a result, high circuit performance and credibility turned out to be significant.

  • PDF

Fuse Protection of IGBT Modules against Explosions

  • Blaabjerg Frede;Iov Florin;Ries Karsten
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.703-707
    • /
    • 2001
  • The demand for protection of power electronic applications has during the last couple of years increased regarding the high-power IGBT modules. Even with an active protection, a high power IGBT still has a risk of exhibiting a violent rupture in the case of a fault if IGBT Fuses do not protect it. By introducing fuses into the circuit this will increase the circuit inductance and slight increase the over-voltage during the turn-off of the diode and the IGBT. It is therefore vital when using fuses that the added inductance is kept at a minimum. This paper discuss three issues regarding the IGBT Fuse protection. First, the problem of adding inductance of existing High-Speed and new Typower fuses in DC-link circuit is treated, second a short discussion of the protection of the IGBT module is done, and finally, the impact of the high frequency loading on the current carrying capability of the fuses is presented.

  • PDF

회로보호용 반도체 소자의 구조적 특성 (Structure Properties of Semiconductor Devices to Protect Electronic Circuit)

  • 홍경진;민용기;조재철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.373-376
    • /
    • 2001
  • When varistors for circuit protection is used at high voltage, it's operation properties were unstable because of leakage current and nonlinear coefficient with grain size. For the purpose of improving of ZnO varistor properties, high voltage ZnO varistor was fabricated with Y$_2$O$_3$addition. Electrical properties were investigated according to sintering conditions and mixing conditions. ZnO varistors was shown ohmic Properties when it's applied voltage was below critical voltage. It was shown non-ohmic properties over critical voltage, because current was increased with decreasing resistance.

  • PDF

가변주파수 인버터를 이용한 접지임피던스의 새로운 측정기법 (A Novel Method for Measuring the Ground Impedance using Variable Frequency Inverter)

  • 이복희;엄주홍
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권5호
    • /
    • pp.253-257
    • /
    • 2004
  • In order to analyze the frequency dependance of ground impedance in grounding grids for lightning and surge protection, a novel method for measuring the ground impedance as a function of frequency were experimentally investigated. The experiments were carried out in rectangular grounding grids with $6{\times}8$ conductors of 22 $mm^2$ buried at a depth of 0.5 m. The test current was injected by the variable frequency inverter whose frequency is linearly controlled for the established period in the range of 5∼500 KHz. The amplitude and phase of ground impedance were calculated from the waveforms of the test current and ground potential rise measured by the band-pass filter tuned in a specific frequency. The frequency dependence of ground impedance was mainly caused by the inductive current flowing through grounding conductors over the frequency of 100 KHz. The proposed measurement method of ground impedance would be applicable to evaluate the transient response characteristics in lightning protection grounding systems.

국제방사선방호위원회와 방사선방호체계 (The ICRP and Its System of Radiological Protection)

  • 조건우
    • 한국환경보건학회지
    • /
    • 제50권1호
    • /
    • pp.1-5
    • /
    • 2024
  • International Commission on Radiological Protection (ICRP) is an independent international organization that advances the science of radiological protection for the public benefit, particularly by providing recommendations and guidance on all aspects of protection against ionizing radiation. The ICRP is a community of more than 380 globally-recognized experts in radiological protection science, policy, and practice from more than 50 countries. As of January 2024, the ICRP is comprised of a Main Commission, the Scientific Secretariat, four Standing Committees, and 30 Task Groups under the four committees. The ICRP has released well over one hundred publications on all aspects of radiological protection. Most address a particular area within radiological protection, but a handful of the publications, the so-called fundamental recommendations, describe the overall system of radiological protection. The system for radiological protection is based on the current understanding of the science of radiation exposure and its effects along with value judgements. The ICRP offers recommendations to regulatory and advisory agencies and provides advice to management and professional staff with responsibilities for radiological protection. Legislation in most countries adheres closely to ICRP recommendations. The International Atomic Energy Agency's (IAEA) International Basic Safety Standards are based heavily on ICRP recommendations. ICRP recommendations form the core of radiological protection standards, legislation, programs, and practice worldwide.

과전류 보호계전기용 광섬유 전류센서 (Fiber-Optic Current Transformer for the Over Current Protection Relay)

  • 송민호;양창순;안성준;박병석;이병호
    • 비파괴검사학회지
    • /
    • 제21권5호
    • /
    • pp.542-548
    • /
    • 2001
  • 과전류 보호계전기에 사용할 목적으로 광섬유를 센서헤드로 사용하는 광 전류센서를 구성하였다. 전류측정의 원리는 도체 주변에 감겨진 광섬유 코일을 따라 광신호의 선형편광축이 자기장에 의하여 회전하는 정도를 측정하여 이로부터 전류의 값을 산출하는 편광측정 방법이 사용되었다. 센서코일은 $10/125{\mu}m$ 규격의 일반 통신용 광섬유를 미터당 20회전 이상 비틀어 제작하여 온도나 진동 등의 환경적 영향을 최소화하였다. 코일의 한쪽 끝은 Faraday Rotator Mirror를 장착한 반사형으로 설계하여 계통을 해체하지 않은 상태에서도 센서의 탈 부착이 가능하고 코일의 회전수에 따라 센서의 민감도 조절이 용이하며 폐회로형 구조이므로 인근 신호원에 의한 간섭을 차단할 수 있다. 편광 빛가르개 등을 이용한 광학 신호처리부를 구성하고 표준 전류원을 이용한 전류측정 실험을 수행한 결과로 이론적인 해석과 동일한 형태의 출력을 얻을 수 있었다. 본 논문에서는 구성한 광 전류센서의 이론적 모델을 기술하고 전류측정 실험의 결과와 이론치에 대하여 비교 분석한다.