• Title/Summary/Keyword: Outside sprinklers

Search Result 3, Processing Time 0.016 seconds

Research for the Configuration of the Outside Sprinkler System (외벽방호 스프링클러시스템 구성에 관한 연구)

  • Min, Se-Hong;Yun, Jung-Eun;Sun, Ju-Seok;Jeong, Sang-Ho;Chea, Chang-Hun;Kim, Suck-Jun
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.102-112
    • /
    • 2012
  • In this research, configulation of outside sprinkler system the prevention and postponement of vertical diffusion of blaze was studied prior to this study, vertical diffusion protecting sprinkler head has been developed and the sprinkler system was applied with discharge pressure of 0.05 MPa and flow of 60 l/min witch is stated in NFPA13's Exposure Protection Sprinkler Systems. Through the system design, we applied the system to the sample building and we made pertinent system to work manually and automatically linked to a fire alarm system. Also, we conducted a real-size mock up test verify the cooling effect of the outer wall and the postponement effect of the flame.

Performance of Holstein cows subjected to different cooling sessions during subtropical summer

  • Bah, Musa;Javed, Khalid;Pasha, Talat Naseer;Shahid, Muhammad Qamer
    • Animal Bioscience
    • /
    • v.35 no.11
    • /
    • pp.1800-1807
    • /
    • 2022
  • Objective: This study aimed to determine the effect of different cooling sessions (CSs) as a water conservation strategy on physiological, and production responses and welfare in Holstein Friesian cows during subtropical summer in Pakistan. Methods: Twenty-one cows were subjected to three CS in a completely randomized design. The treatments were: i) eleven hours continuous cooling with sprinklers - control (CNT), ii) four CS, and iii) two CS. The CNT represented the practices of the commercial dairy farms in the area, while the other CSs were used as water reduction strategies. Each CS lasted for 1 h with a 12 min cycle (3 min water on and 9 min off) with a sprinkler flow rate of 1.25 L/min. Results: The average temperature humidity index of the shed and the outside open area were 81.9 and 82.5, respectively. The results showed that both physiological responses were highest in the 2CS group followed by the CNT and the 4CS (p = 0.001). The CNT and 4CS groups had similar milk yield (p = 0.040). The 4CS group had more lying and eating times than the CNT and 2CS groups (p = 0.000). The cortisol level in the 2CS group was 2.0 and 2.2 ㎍/dL more than the CNT and the 4CS groups, respectively (p = 0.000). Conclusion: In conclusion, the 4CS was more efficient in cooling the cows and had better welfare, as it yielded similar milk yield, and better physiological responses than the CNT despite using 90% less water.

Fire Experiment for a Water Curtain Nozzle in a Double Glazed Curtain Wall System (유리커튼월 수막시스템 분무헤드의 화재 실험 연구)

  • Kim, Sung-Won;Nam, Jiwoo;Cho, Seongwook;Ryou, Hong-Sun;Nam, Jun-Seok;Kim, Dong-Joon
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.31-40
    • /
    • 2016
  • Recently, a curtain wall system was applied to skyscrapers to prevent fire spreading along the vertical direction due to stack effect and outside air flow when a fire breaks out in skyscraper. Conventional sprinklers cannot prevent the spread of fire to the upstairs areas, which increases the loss of life and property. In this study, a water curtain nozzle that creates wider water coverage on the surface of glass and can prevent the spread of fire to the upstairs areas was developed. The spray pattern of the water curtain nozzle was compared with that of a sprinkler to determine performance of the water curtain nozzle. A fire experiment was constructed on the second floor to verify performance of the water curtain nozzle in preventing the spread of fire to the upstairs areas. The fire and watering experiment proved that the water curtain nozzle prevented more effectively the spread of fire than the conventional sprinkler. The position of first crack and critical temperature of fracture were also analyzed using numerical analysis.