• 제목/요약/키워드: Outside heat transfer coefficient

검색결과 67건 처리시간 0.116초

전조 나선핀 튜브의 외부핀 형상 변화에 의한 열전달 향상에 관한 연구 (A Study on the Heat Transfer Improvement of Integral-Fin Tubes by External Fin Effect)

  • 한규일;조동현
    • 수산해양기술연구
    • /
    • 제30권1호
    • /
    • pp.33-44
    • /
    • 1994
  • This work studies for boiling and condensation heat transfer performance of trapezoidally shaped integral-fin tubes having fin densities from 748fpm to 1654fpm. For comparison, tests are made using a plain tube having the same inside and outside diameter as that of the root of fins of finned tubes. Hahne's theoretical model and Webb's theoretical model are used to predict the R-11 boiling heat transfer coefficient and condensing heat transfer coefficient respectively for plain tube and all integral-fin tubes. Experiments are carried out using R-11 as working fluid. This work is limited to film-wise condensation and pool boiling on the outside surface of plain tube and 4 low integral-fin tubes. In case of condensation, the refrigerant condenses at saturation state of 32$^{\circ}C$ on the outside tube surface cooled by coolant and in case of boiling. the refrigerant evaporates at saturation state of 1bar on the outside tube surface. The amount of non-con-densable gases in the test loop is reduced to a negligible value by repeated purging. The actual boiling and condensing processes occur on the outside tube surfaces. Hence the nature of this surface geometry affects the heat transfer performances of condenser and evaporator in refrigerating system. The condensation heat transfer coefficient of integral-fin tube is enhanced by both extended tube surface area and surface tension. The ratio of the condensation heat transfer coefficients of finned to plain tubes is greater than that of surface area of finned to plain tubes, while ratio of the boiling heat transfer coefficient of finned to plain tubes shows reverse result. As a result, low integral-fin tube can be used in condenser more effectively than used in evaporator.

  • PDF

터보 냉동기용 핀 튜브에 관한 연구(II) - 비등 열전달에 관하여 - (A Study on Finned Tube Used in Turbo Refrigerator(II) - on boiling heat transfer -)

  • 한규일;김시영;조동현
    • 수산해양교육연구
    • /
    • 제5권2호
    • /
    • pp.119-127
    • /
    • 1993
  • This work studies for heat transfer and pressure drop performance of integral inner and outer fin tubes, designed to enhance the heat transfer performance of smooth tubes for in recipro and turbo refrigerator or high performance compact heat exchangers. Eight different inner spiral fin copper tubes with integral fin at outside surfaces were employed to improve boiling heat transfer coeffcient. For comparison, tests were made using a plain tube having the inside diameter and an outside diameter equal to that at the root of the fins for the finned tubes. Pool boiling heat transfer is investigated experimentally and theoretically on single tube arrangement. The refrigerant evaporates at a saturation state of 1 bar on the outside tube surface heated by hot water. The refrigerant R11 ($CFCl_3$) was used at a pressure of $P_s=1bar$ as a convenient test fluid with a boiling temperature of $T_s=23.6^{\circ}C$. The observed heat transfer enhancement of boiling for finned tubes significantly exceeded that to be expected on grounds of increased area. The maximum Vapor - side enhancement(i.e., vapor - side heat transfer coefficient of finned tube/vapor - side coefficient for plain tube) was found to be around 4 at 1299fpm - 30grooves tube.

  • PDF

수직원관 외부 유하액막 열전달에 주변 기체유동이 미치는 영향 (The Effect of Surrounding Gas Flow on the Heat Transfer of the Falling Film Flowing Down the Outside of a Vertical Tube)

  • 권경민;정시영;김병주
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.996-1003
    • /
    • 2002
  • Heat transfer characteristics were investigated for the falling film flowing down the outside of an electrically heated vertical tube. Water was used for the falling film, and its Reynolds number was varied in the range of 70~500. Because water is heated and evaporated as it flows down, both sensible and latent heat transfer should be considered. The effect of the surrounding air movement was investigated by changing the direction of the air injection; without air injection, parallel-flow, and counter-flow. For all cases, sensible teat transfer rate was almost linearly increased with the increasing film flow rate. It was found that the film heat transfer coefficient was hardly influenced by the parallel air flow. However, the counter-flow of air reduced the heat transfer coefficient, which might be caused by the uneven distribution or flooding of the film. At high heat flux, a sudden change of the film heat transfer coefficient was detected as the film flow rate reached the transition value. It is supposed that this phenomenon was caused by the change in the film flow pattern.

플라스틱온실 피복재의 관류열전달계수 변화 (Variation of the Overall Heat Transfer Coefficient of Plastic Greenhouse Covering Material)

  • 이현우;소레이멘디옵;김영식
    • 생물환경조절학회지
    • /
    • 제20권2호
    • /
    • pp.72-77
    • /
    • 2011
  • 본 연구는 국내 상업용 온실 피복재의 관류열전달계수를 산정히는데 필요한 기초자료를 제공하기 위하여 최근 국내에 많이 보급되어 사용되고 있는 플라스틱필름으로 피복된 온실에 대해 관류열량을 측정하고 관류열전달계수의 변화를 분석하였으며 그 결과를 요약하면 다음과 같다. 온실 내외부 온도차에 따른 관류열전달계수의 변화를 분석한 결과 피복의 층수에 따라 안정된 관류열전달계수를 나타내게 되는 온실 내외부 온도차의 값이 다르게 나타났기 때문에 온실 피복재에 대한 관류열전달계수를 결정할 때에는 피복층수별로 안정된 값을 나타내는 온실 내외부 온도차 범위에서의 관류열전달계수를 채택하여야할 것이다. 온도차이에 따른 관류열전달계수의 변화 경향은 기존의 연구결과와 잘 일치하였으나 안정된 값을 나타내는 온도차이의 구체적인 값은 다르게 나타났기 때문에 이에 대한 추가적인 연구가 필요할 것으로 판단된다. 풍속에 따른 관류열전달계수의 증가율은 연구자에 따라 많은 차이가 있음을 알 수 있었으며, 이중피복온실이나 커튼을 설치한 온실과 같이 보온성을 높인 온실은 일중피복온실에 비해 풍속에 따른 관류열 손실이 더 작다는 사실을 확인할 수 있었다. 관류열전달계수의 기존 연구결과들을 분석한 결과 연구자에 따라 값이 차이가 있었기 때문에 국내 온실의 정확한 난방부하량을 산정하는데 필요한 적절한 관류열전달계수를 제시하기 위해서는 우선 측정을 위한 표준화된 환경기준이 마련될 필요가 있으며, 또한 국내에서 실제로 사용되고 있는 주요 피복재별로 구체적인 관류열전달계수가 구해져야 할 것이다.

열매체유 유동층 열교환기의 전열성능에 대한 실험적 연구 (An Experimental Study on Heat Transfer Performance of Heating Medium Oil Fluidized Bed Heat Exchanger)

  • 박상일;고창복;이영수
    • 설비공학논문집
    • /
    • 제27권3호
    • /
    • pp.146-151
    • /
    • 2015
  • The heat transfer performance of heating medium oil fluidized bed heat exchanger was measured. The operation variables were air flow rate, air inlet temperature, moisture content, water flow rate and water inlet temperature. The outside heat transfer coefficient was determined from the heat exchanger experiment and its experimental correlation was determined as a function of air velocity and viscosity of heating medium oil. Effect of viscosity was well agreed with the previous studies. Errors of the correlation equation was less than about 10% for outside heat transfer coefficient developed in this study when compared with the measured value. Hot water with the temperature greater than $77^{\circ}C$ could be produced by using the heating medium oil fluidized bed heat exchanger.

자동차용 에어컨 응축기의 설계기술 개발 (Development of design technique for automotive condenser)

  • 조영두;한창섭;유성연
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.10-17
    • /
    • 1999
  • The present work presents condensation heat transfer and pressure drop data for the flow of R-12 in flat extruded aluminum tubes with small hydraulic diameters. The tube outside dimensions are $18mm(width){\times}1.7mm(height)$. Three types of internal geometry with the same outside dimensions are tested : sample 1 (7 tube holes), sample 2 (13 tube holes) and sample 3 (7 tube holes, micro-fin). The overall heat transfer coefficient is obtained for air-to-refrigerant heat transfer, and the Wilson plot method is used to determine the heat transfer coefficient for refrigerant flow. The sample 2 and sample 3 show significantly higher performance than sample 1. The heat transfer rates for the sample 2 and sample 3 are 9% and 12% higher, respectively, than sample 1. The friction factors for the sample 2 and sample 3 are 11.9% and 2.4% higher, respectively, than sample 1.

  • PDF

해양 구조물용 공조덕트 열유동에 관한 수치해석 (Numerical Analysis on the Thermal and Fluid in Air Conditioning Duct for Marine Offshore)

  • 이중섭;이병호;진도훈
    • 한국기계가공학회지
    • /
    • 제18권2호
    • /
    • pp.7-13
    • /
    • 2019
  • This study is about distributions of heat transfer in air conditioning duct used for marine and oil drilling ship. As the convective heat transfer coefficient increased, heat transfer was conducted dynamically to inside as it exited to the outlet of duct. So, it was checked that the amount of heat transfer generated at duct increased as the convective heat transfer coefficient increased. In case the convective heat transfer coefficient was low, the temperature of duct showed the relatively high temperature distribution due to the temperature influence of internal fluid as the heat transfer between the outside and inside of the duct. In case of temperature distribution generated the volume of the duct along the change of the convective heat transfer coefficient, it was found out that the temperature descended as heat transfer was promoted and the convective heat transfer coefficient increased.

수평관 외벽에서 친수성 표면처리가 응축열전달에 미치는 영향 (Effects of Hydrophilic Surface Treatment on Condensation Heat Transfer at the Outside Wall of Horizontal Tube)

  • 황규대;박노성;강병하
    • 설비공학논문집
    • /
    • 제12권6호
    • /
    • pp.533-540
    • /
    • 2000
  • Condensation heat transfer characteristics have been investigated experimentally when a water vapor is condensed on the outside of a horizontal copper tube in a condenser. This problem is of particular interest in the design of a LiBr-water absorption system. Hydrophilic surface modification was performed to increase the wettability on the copper tube. The optimum hydrophilic treatment condition using acethylene and nitrogen as reaction gas is also studied in detail. The results obtained indicate that the optimum reaction gas ratio of acethylene to nitrogen for hydrophilic surface modification was found to be 7 : 3 for the best condensation heat transfer. In the wide ranges of coolant inlet temperatures, and coolant mass flow rates, both the condensation heat transfer rate and the condensation heat transfer coefficient of a hydrophilic copper tube are increased substantially, compared with those of a conventional copper tube used in a condenser. It is also found that the condensation heat transfer enhancement by the hydrophilic surface modification still emains even after a hundred cycles of wet/dry processes.

  • PDF

A Study on the Greenhouse Water Curtain System: Heat Transfer Characteristics

  • 손원명;한길영
    • 한국농공학회지
    • /
    • 제32권E호
    • /
    • pp.80-87
    • /
    • 1990
  • Energy balance equations Were developed to describe the heat transfer mechanisms in a double layer plastic greenhouse with a water curtain system. Heat transfer variables were determined by using various temperature data measured in a conventional prototype semicircular cross-section greenhouse over a range of water temperatures and water flow rates. The heat transfer coefficient between flowing water and greenhouse air was independent of water flow rates. But the heat transfer coefficient between water surface and the stagnant air space within the double plastic layer was dependent on water flow rates. Substituting the heat transfer coefficients, determined from the energy balance equations in the heat transfer equations, demonstrated various relationships among ambient air temperature, greenhouse air temperature, water temperature, and water flow rates. The heating benefits were linearly related to not only the inside and outside air temperatures but also to the water temperature. The energy conservation effects of the water curtain system were found even initial water temperatures were considerably lower than the greenhouse setting temperatures. Sensitivity analysis for heat transfer coefficients demonstrated that the heat transfer coefficient between greenhouse air and the stagnant air within the plastic layers was the most significant coefficient in the estimation of heating effects.

  • PDF

해양 구조물용 공조덕트 열유동에 관한 수치해석 (Numerical Analysis on the Thermal and Fluid in Air Conditioning Duct for Marine Offshore)

  • 이중섭;이병호;진도훈
    • 한국기계가공학회지
    • /
    • 제17권5호
    • /
    • pp.23-29
    • /
    • 2018
  • This study is about the distribution of heat transfer in air conditioning ducts used for marine vessels and oil drilling platforms. As the convective heat transfer coefficient increased, heat transfer was conducted dynamically to inside as it exited to the outlet of duct. The experiment was to determine if the amount of heat transfer generated at the duct exit increased as the convective heat transfer coefficient increased. When the convective heat transfer coefficient was low, the temperature of the duct showed a relatively high temperature difference between the outside and inside of the duct due to the temperature influence of the internal fluid. In case of temperature distribution generated the volume of the duct along the change of the convective heat transfer coefficient, the temperature descended as heat transfer was promoted and the convective heat transfer coefficient increased.