• Title/Summary/Keyword: Output density

Search Result 776, Processing Time 0.032 seconds

SETTING OF HPA OUTPUT POWER IN COMS DATS CONSIDERING IMD CHARACTERISTICS

  • Park, Durk-Jong;Yang, Hyung-Mo;Ahn, Sang-Il
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.204-207
    • /
    • 2006
  • COMS will receive two different meteorological signals in S-Band from IDACS (Image Data Acquisition and Control System) in ground station before transmitting them in L-Band to user station. MODCS (Meteorological Ocean Data Communication Subsystem) in satellite released the value of required PFD (Power Flux Density) to receive two signals. Thus, DATS (Data Acquisition and Transmission Subsystem) needs to send two signals to satellite with a satisfied EIRP. The value of minimum HPA (High Power Amplifier) output power was estimated by subtracting antenna directional gain and path loss between antenna and HPA from the needed EIRP in this paper. Besides the minimum output power of HPA, the maximum output power was also calculated with considering IMD (Inter-Modulation Distortion) characteristics. IMD is always occurred in the output of HPA when LRIT and HRIT are amplified by using single HPA as COMS application. In this paper, the setting of maximum output power was determined when the IMD of modelled HPA was corresponded to the requirement of MODCS.

  • PDF

Analysis on the Characteristics of Magnetic Amplifier for Multi-output Postregulation (다출력 전원회로의 안정화를 위한 자기증폭기의 특성해석)

  • Kim, Cherl-Jin;Lee, Kwan-Yong;Hong, Dae-Shik;Kim, Young-Tae;Baek, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.133-135
    • /
    • 2004
  • As a result of the recent advances in magnetic materials, the Magnetic Amplifier(Magamp) technique is one of the reliable and cost-effective postregulation method for multiple-output power supply. This is true for high-current postregulated output since at highter output current the efficiency of linear postregulation is unacceptably low, while the complexity of more efficient switch mode postregulator is associated with a significant cost. Magamp have some advantages of higher power density, simple control circuit, good regulation, high frequency and high performance. In this paper, Operation principle of proposed approach and a performance of magamp control circuit with TL431 is described. The comparative analysis of magamp circuit and buck regulator circuit with 20W load condition is conducted. Experimental verifications on multi-output flyback converter are conducted. Simulations and experimental results show that the proposed approach is efficiency and voltage regulation of the auxiliary output is excellent.

  • PDF

Analysis, Design and Implementation of a New Chokeless Interleaved ZVS Forward-Flyback Converter

  • Taheri, Meghdad;Milimonfared, Jafar;Namadmalan, Alireza;Bayat, Hasan;Bakhshizadeh, Mohammad Kazem
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.499-506
    • /
    • 2011
  • This paper presents an interleaved active-clamping zero-voltage-switching (ZVS) forward-flyback converter without an output choke. The presented topology has two active-clamping circuits with two separated transformers. Because of the interleaved operation of the converter, the output current ripple will be reduced. The proposed converter can approximately share the total load current between the two secondaries. Therefore, the transformer copper loss and the rectifier diodes conduction loss can be decreased. The output capacitor is made of two series capacitors which reduces the peak reverse voltage of the rectifier diodes. The circuit has no output inductor and few semiconductor elements, such that the adopted circuit has a simpler structure, a lower cost and is suitable for high power density applications. A detailed analysis and the design of this new converter are described. A prototype converter has been implemented and experimental results have been recorded with an ac input voltage of 85-135Vrms, an output voltage of 12V and an output current of 16A.

A Study on the Output Characteristics According to the Cell Electrode Pattern for a Large-area Double-sided Shingled Module (대면적 양면형 슁글드 모듈을 위한 셀 전극 패턴에 따른 출력 특성에 관한 연구)

  • Seungah, Ur;Juhwi, Kim;Jaehyeong, Lee
    • New & Renewable Energy
    • /
    • v.18 no.4
    • /
    • pp.64-69
    • /
    • 2022
  • Double-sided photovoltaic (PV) modules have received significant attention in recent years as a technology that can achieve higher annual energy production rates than single-sided modules. The shingled technology is a promising method for manufacturing high-density and high-power modules. These modules are divided by laser and joined with electrically conductive adhesives. The output efficiency of the divided cells depends on the division pattern and the electrode pattern, making it important to understand the output characteristics. In this study, the output characteristics of large-area double-sided light-receiving shingled cells with different split patterns and electrode patterns were investigated. The M6 size, with 6 divisions in the electrode pattern, had the highest efficiency when using 142 front fingers and 146 rear fingers. The M10 size, with 7 divisions, had the highest output when using 150 fingers equally in the front and rear. The M12 size, also with 7 divisions, showed the highest output characteristics when using 192 front fingers and 208 rear fingers.

100W On-Board Power Supply Using Flat Transformer (Flat Transformer를 이용한 100W급 On-Board Power Supply)

  • 황치면;송두익;조정구;정창용;홍승대;하태복
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.577-580
    • /
    • 1999
  • High power density on-board power supply is implemented by using flat transformer. In the high frequency switching converters, large leakage inductance increases the switching stress and duty cycle loss, which sometimes limits maximum switching frequency. The flat transformer is designed by using special core structure, which has very low profile and low temperature rise since the thermal loading is spread evenly over a larger area. 100W, 3.3V output on board supply is built and tested and 50.7W/$\textrm{inch}^{3}$ power density is achieved.

  • PDF

Performance Comparison of LDPC codes with Different Soft-output Algorithm for High Density Optical Recording Channel (고밀도 광 기록 채널에서 LDPC 부호의 연판정 출력 알고리즘별 성능비교)

  • Lee, Bong-Il;Lee, Jae-Jin
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.891-892
    • /
    • 2008
  • 본 논문에서는 최근 주목받고 있는 에러 정정 기법 중 하나인 LDPC(Low Density Parity Check) 부호를 광 기록 채널(Optical Recording Channel)에 적용해 보았고 이때 사용되는 연판정 출력 알고리즘으로 MAP과 SOVA를 이용하여 성능을 비교하였다.

  • PDF

Acoustic outputs from clinical ballistic extracorporeal shock wave therapeutic devices (임상에서 사용중인 탄도형 체외충격파 치료기의 음향 출력)

  • Cho, Jin Sik;Kwon, Oh Bin;Jeon, Sung Joung;Lee, Min Young;Kim, Jong Min;Choi, Min Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.5
    • /
    • pp.570-588
    • /
    • 2022
  • We scrutinized the acoustic outputs from the 70 shock wave generators of the 15 product models whose technical documents were available, among the 46 ballistic extracorporeal shock wave therapeutic devices of 11 domestic and 6 foreign manufacturers, approved by the Minster of Food & Drug Safety (Rep. Korea). We found that the acoustic Energy Flux Density (EFD), the most popular exposure parameter, was different by up to 563.64 times among shock wave generators at their minimum output settings and by up to 74.62 times at their maximum settings. In the same product model, the EFD was shown to vary depending on shock wave transmitters by up to 81.82 times at its minimum output setting and by up to 46.15 times at its maximum setting. The lowest EFD 0.013 mJ/mm2 at the maximum output settings was much lower (2.1 %) than the maximum value 0.62 mJ/mm2 at the minimum settings. The Large acoustic output differences (tens to hundreds of times)from the therapeutic devices approved for the same clinical indications imply that their therapeutic efficacy & safety may not be assured. The findings suggest the regulatory authority to revise her guideline to give clearer criteria for clinical approval and equality in performance, and recommend the authority to initiate a post-approval surveillance as well as a test in conformance between the data in technical documents and the real acoustic outputs clinically used.

Modeling of Memory Effects in Power Amplifiers Using Advanced Three-Box Model with Memory Polynomial (전력 증폭기의 메모리 효과 모델링을 위한 메모리 다항식을 이용한 향상된 Three-Box 모델)

  • Ku Hyun-Chul;Lee Kang-Yoon;Hur Jeong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.5 s.108
    • /
    • pp.408-415
    • /
    • 2006
  • This paper suggests an improved system-level model of RF power amplifiers(PAs) including memory effects, and validates the suggested model by analyzing the power spectral density of the output signal with a predistortion linearizer. The original three-box(Wiener-Hammerstein) model uses input and output filters to capture RF frequency response of PAs. The adjacent spectral regrowth that occurs in three-box model can be perfectly removed by Hammerstein structure predistorter. However, the predistorter based on Hammerstein structure achieves limited performance in real PA applications due to other memory effects except RF frequency response. The spectrum of the output signal can be predicted accurately using the suggested model that changes a memoryless block in a three-box model with a memory polynomial. The proposed model accurately predicts the output spectrum density of PA with Hammerstein structure predistorter with less than 2 dB errors over ${\pm}30$ MHz adjacent channel ranges for IEEE 802.11 g WLAN signal.

DFSS-Based Design of a Hall-Effect Rotary Position Sensor (DFSS 를 이용한 홀 효과 기반 회전형 위치 센서의 설계)

  • Kim, Jae-Eun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.2
    • /
    • pp.231-236
    • /
    • 2012
  • This work presents the application of the DFSS (Design for Six Sigma) methodology to optimizing both the linearity and the sensitivity of the output voltage of a Hall-effect rotary position sensor. To this end, the dimensions and relative positions of a permanent magnet with reference to a Hall sensor are selected as the design factors for a full factorial design. In order to evaluate the output voltage of the rotary position sensor at each run in the experimental design, analytical solutions to the magnetic flux density were obtained using the Biot-Savart law and the relations between the magnetic flux density and the output voltage intrinsic to a Hall sensor. Through measurements of the improved output voltage of the rotary position sensors manufactured using the optimized design factors, the proposed method is shown to be simple and practical.

GafChromic RTQA Film Dosimetry for Laser Beam with Photodynamic Therapy (GafChromic RTQA Film을 이용한 광역학적 치료용 레이저의 선질 측정)

  • Lee, Byung Koo;Lim, Hyun Soo;Kenar, Necla
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.73-79
    • /
    • 2013
  • Purpose: The purposes of this study were to measure the dose distribution of Photodynamic therapy(PDT) laser with 635 nm wavelength using GafChromic film. Method & Result: We made each output 300 J by changing mW and sec using the laser beam radiation mode such as C.W(Continuous Wave) mode, Pulse mode and Burst Pulse mode and measured the does at 0 mm and 5 mm of distance from optic fiber catheter end to the film, and at 5 mm distance by changing the angle of the end of the optic fiber catheter as $0^{\circ}$ and $0.5^{\circ}$. The radiated film was scanned and OD(Optical Density) was compared. And two-dimensional isodose curves were obtained and the consistency of shapes was compared. It was confirmed that there was consistency between optic density and the dose radiated on the film when we radiated GafChromic film by changing distance and angle of 300 J output in each radiation mode coordinating mW and sec. Conclusion: In this study, we could identify the stability according to changes in laser beam modes, changes in output according to distance, changes in uniformity according to angle, and beam profiles using GafChromic film, and we could also get two-dimensional isodose curve. It was found that small change in the distance and angle that is made when optic fiber catheter was contacted on the treatment area did not make big effects on the output of beam and the uniformity of dose, and it was also found that GafChromic film could be utilized for the purpose of QA of PDT laser beam.