• Title/Summary/Keyword: Outlet Valve

Search Result 199, Processing Time 0.026 seconds

The Intact Evaluation of High Pressure Control Valve Trim Parts (고차압 제어밸브 트림부 분석 및 개선방안 검토)

  • Jang, H.;Yoon, I.S.;Kim, Y.B.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.581-584
    • /
    • 2008
  • At the inlet and outlet differential pressure and The fluid velocity over 32m/s are damaged (Plug, sheet ring, trim) About reduction trim parts of the control valve. AOV of the differential pressure 1,500psi become often the damage in the nuclear power plant. Damages of AOV studied CFD analysis and improvement program. Multi-stage trim designs which decrease a fluid kinetic energy are demanded and AOV parts are demanded case hardening and material change.

  • PDF

Expansion Valves Characteristics for Development of Control System on Air Conditioning and Refrigeration Systems (공조.냉동장치의 제어시스템 개발을 위한 팽창밸브 특성)

  • Kim, J.D.;Jang, J.E.;Yoon, J.I.
    • Journal of Power System Engineering
    • /
    • v.2 no.3
    • /
    • pp.34-40
    • /
    • 1998
  • Performance characteristics of a refrigeration systems with various expansion valves and superheat changes were investigated experimentally. Experimental data have been taken utilizing three different devices; a thermostatic expansion valve, a linear type electronic expansion valve and a solenoid type electronic expansion valve. The data taken from tile three types of expansion valves were discussed with the temperature distribution of each zone in the evaporator and the superheat changes of the evaporator outlet In each zone temperature distribution fluctuated larger with the thermostatic expansion valve than with the electronic expansion valves. The optimum superheat ranged from $5^{\circ}C\;to\;15^{\circ}C$, and the superheat with the thermostatic expansion valve showed hunting phenomenon, which affected the evaporating and condensing temperature.

  • PDF

Study on the Real-Time Leak Monitoring Technique for Power Plant Valves (발전용 밸브누설 실시간 감시기술 연구)

  • Lee, S.G.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.39-44
    • /
    • 2007
  • The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

Development of Y Strainer Type Automatic Flow Rate Regulating Valve (Y 스트레이너형 자동 정유량 조절 밸브의 개발)

  • Yoon, Joon-Yong;Kwon, Woo-Chul
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.1 s.40
    • /
    • pp.49-55
    • /
    • 2007
  • An 'Y' strainer type automatic flow rate regulating valve, which functions are to remove impurities from hot water inside the pipe and to maintain a constant flow rate regardless of variations of the differential pressure between valve inlet and outlet at the same time, is developed for distributing hot water equally to several pipes with district heating or central heating system. Numerical analysis of the three dimensional turbulent flow field in a valve shape is carried out to confirm the flow field whether the designed regulator shape is acceptable or not. The final developed valve improves installation time and cost and maintenance ability comparing with set-up 'Y' strainer and regulator separately. Tolerance for the nominal flow rate is also satisfied within ${\pm}5%$.

Flow Characteristics of the Servo Valve in the Fuel Supply System of APU (보조 동력 장치 연료 공급용 서보밸브의 유동 특성 해석)

  • Kim, S.S.;Chang, S.M.;Jeong, H.S.;Ryu, H.;Lee, S.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.5 no.4
    • /
    • pp.10-16
    • /
    • 2008
  • In this paper, the authors benchmark a servo valve model for the fuel supply system of Auxiliary Power Unit (APU) in the KHP helicopter. This valve is directly driven with a torque motor, and the size of small gap controlled by a flapper can make change of flow rate under given pressure drop between inlet and outlet. CFD analyses using a commercial code, ANSYS-CFX 10 are performed for the series of three-dimensional models at various openness conditions. The computational results on simplified models show that CFD can play a fine roll in the design of flow path as well as in the estimation of flow force due to its precision and good repeatability. Consequently, the CFD analysis helps valve designers to understand its flow characteristics from the basis of physical fundamentals.

  • PDF

Flow Control for High Pressure Gas by using a Solenoid Valve (솔레노이드 밸브를 이용한 고압가스의 유량제어)

  • Sim Han-sub;Lee Chi-woo;Kim Nam-kyung;Ahn Kook-chan;Namkoong Chai-kwan
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.156-161
    • /
    • 2005
  • Dynamic flow characteristics of a solenoid valve are affected by pressure difference in inlet and outlet of orifice, gas temperature, and supply voltage of a coil. In this paper, the dynamic flow characteristics for deviations of various conditions are studied Static and dynamic flow for variation on-time of a solenoid valve open signal are measured in basic bench test. The solenoid valve is applied to a compressed natural gas(CNG) engine test for validation of flow control performance. The experimental results show that flow of high pressure gas can controlled precisely by using a solenoid valve.

  • PDF

Performance and Sensitivity Analysis of Disk-type Fluidic Control System (디스크형 유체역학적 방향제어 시스템 성능해석 및 설계 인자 민감도 분석)

  • Cho, Mingyoung;Han, Doohee;Sung, Hong-Gye;Choi, Hyun Yung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.3
    • /
    • pp.103-110
    • /
    • 2016
  • A performance analysis program of a disk type fluidic valve was developed to predict a chamber pressure and a response time. A parametric study of this device was performed by using scattering plot method. A sensitivity of Mach number at a nozzle outlet showed the highest value about a outlet diameter of nozzle. An inlet flow rate is the most important parameter to design the fluidic valve because it has high sensitivity value both a outlet velocity and a response time.

Finite Element Analysis on the Deformation Behavior Safety of a Gas Valve (가스밸브의 변형거동 안전성에 관한 유한요소해석)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.4
    • /
    • pp.70-75
    • /
    • 2017
  • This paper presents the FEM analysis results on the deformation behavior safety of automatic cut-off horizontal and conventional vertical gas valves. Based on the FEM analysis, the primary maximum deformation of $4.4{\mu}m$ was formed on the right end side of a valve body when the internal gas pressure was supplied on the screw port and gas discharge port of an automatic cut-off horizontal gas valve. And the secondary maximum deformation of $2.9{\mu}m$ was formed on the end side of safety valve port. This small deformation of an automatic cut-off horizontal gas valve is strongly related to the balanced design of a horizontal gas valve main body, which is composed of a screw part, gas outlet port, port for a stem and spindle shaft assembly, and safety valve port. But, the primary maximum deformation of 0.076mm was formed on the upper part of a conventional automatic cut-off vertical gas valve when the internal gas pressure was supplied on the screw port and gas discharge port. And the secondary maximum deformation of 0.055mm was formed on the left end side of a gas outlet port. This may effect on the sealing clearance of o-ring that is inserted on the groove of an automatic cut-off unit. Thus, this paper recommends an automatic cut-off horizontal gas valve compared with that of a conventional gas valve for a gas leakage free mechanism of a LPG cylinder valve.

Capacity Modulation of a Multi-Type Heat Pump System using PID Control with Fuzzy Logic (퍼지 로직 적용 PID 제어를 이용한 멀티형 열펌프의 용량조절)

  • 김세영;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.9
    • /
    • pp.810-817
    • /
    • 2001
  • Performance of a water-to-water multi-type heat pump system using R22 which has tow indoor units has been investigated experimentally. The refrigerant flow rate of each indoor unit was regulated by an electronic expansion valve and the total refrigerant flow rate of the system was controlled by a variable speed compressor. In the system, evaporator outlet pressure of refrigerant and outlet temperatures of secondary fluid from indoor units were selected as control variables. Experiments were executed for both cooling and heating modes using PID control method with fuzzy logic, and results of the test are compared with a classical PID method. In the case of PID control with fuzzy logic, the fuzzy control rules corrects PID parameters each time. Results show that PID control with fuzzy logic has the merits of quick response and reduced overshoot.

  • PDF

An Experimental Study on the Impact Force of a Mechanical Heart Valve Prostheses (기계식 심장판막의 충격력에 관한 실험적 연구)

  • Lee, J.H.;Cheon, G.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.167-171
    • /
    • 1996
  • Impact force and strains induced by impact between the occluder and the struts have been measured with force senfor and strain gages. The maximum reaction force was about 25N, and the calculated impact force on the root of the struts amount about $9{\sim}17N$. Impact force on the inlet strut is greater than that of the outlet strut, but the strain on the outlet strut is much higher than that of the inlet strut. These values might cause severe damage on the valve in the critical cases. The results of this study may be extended for the analysis of the endurance limit and optimal design of the struts and occluder.

  • PDF