• 제목/요약/키워드: Outlet Temperature

검색결과 686건 처리시간 0.027초

틸팅열차 주변압기 냉각시스템의 온도설정알고리즘 (Temperature Setpoint Algorithm for the Cooling System of a Tilting Train Main Transformer)

  • 한도영;노희전;원재영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.387-392
    • /
    • 2008
  • In order to improve the efficiency of the main transformer in a tilting train, the optimal operation of a cooling system is necessary. For the development of the optimal control algorithm of a cooling system, the mathematical model of a main transformer cooling system was developed. This includes the dynamic model of a main transformer, an oil pump, an oil cooler and a blower. The system algorithm of a cooling system, which consists of the temperature setpoint algorithm and the temperature control algorithm, was developed. Optimal oil temperatures of the inlet and the outlet of the main transformer were obtained by considering the total electric power consumption of the system. The oil inlet temperature was controlled by the blower and the oil outlet temperature was controlled by the oil pump. A simulation program was developed by using the mathematical model and the system algorithm. Simulation results showed that the system algorithm developed from this study may be effectively used to control the main transformer cooling system in a tilting train.

  • PDF

A Study on High Precision Temperature Control of an Oil Cooler for Machine Tools Using Hot-gas Bypass Method

  • Jung, Young-Mi;Byun, Jong-Yeong;Yoon, Jung-In;Jeong, Seok-Kwon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권7호
    • /
    • pp.1003-1011
    • /
    • 2009
  • This study aims at precise control of oil outlet temperature in the oil cooler system of machine tools for enhancement of working speed and processing accuracy. PID control logic is adopted to obtain desired oil outlet temperature of the oil cooler system with hot-gas bypass method. We showed that the gains of PID controller could be easily determined by using gain tuning methods to get the gain of PID controller without any mathematical model. We also investigated various gain tuning methods to design the gains of PID and compared each control performance for selecting the optimal tuning method on the hot gas bypass method through experiments. Moreover, we confirmed excellent control performance with proposed PI controller gain even though disturbances were abruptly added to the experimental system.

구형축열체를 이용한 축열기내 열유동 해석 (Thermal flow analysis in heat regenerator with spheres)

  • 조한창;조길원;이용국
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2003년도 춘계 학술발표회 논문집
    • /
    • pp.359-364
    • /
    • 2003
  • Heat regenerator occupied by regenerative materials improves thermal efficiency of regenerative combustion system through the recovery of sensible heat of exhaust gases. By using one-dimensional two-phase fluid dynamics model, the unsteady thermal flow of regenerator with spherical particles, were numerically analyzed to evaluate the heat transfer and pressure losses and to suggest the parameter for designing heat regenerator. It is confirmed that the computational results, such as air preheat temperature, exhausted gases outlet temperature, and pressure losses, agreed well with the experimental data conducted from Chugairo. The thermal flow in heat regenerator varies with porosity, configuration of regenerator and diameter of regenerative particle. Assuming a given exhaust gases temperature at the regenerator outlet, the regenerator length need to be linearly increased with inlet Reynolds number of exhaust gases. It is considered that inlet Reynolds number of exhaust gases should be introduced as a regenerator design parameter.

  • PDF

프레온-22를 작동유체로 사용한 소용량 온도차 발전에 관한 실험적 연구 (An Experimental Study on the Small Power Generation of Temperature difference using the Freon-22 as Working Fluid)

  • 전춘생;신익호;허창수
    • 태양에너지
    • /
    • 제8권2호
    • /
    • pp.26-38
    • /
    • 1988
  • If proper design and selection of the working fluid are made the power generation system of temperature difference could achieve more efficient results than others. This paper is to analysis the production of its power generation due to several parameters. Making the power generation system, the characteristics of power output are investigated to obtain its basic data for design. This results of this experiment are as follows. 1. The most proper working fluid in the system is Freon-22 having high stability and difference between the outlet pressure, $P_E$ of evaporator and outlet pressure, $P_c$ of Condenser. 2. With the increase of temperature difference between evaporator and condenser, the output in the system increases linearly. 3. The generation efficiency is largely dependent on the type or form of propeller, nozzle and optimum design of heat exchanger.

  • PDF

유동해석을 통한 선박용 디젤엔진(LDCL JWCS)의 3-Way Valve 형상 설계 (Shape Design of the 3-Way Valve used in Marine Diesel Engines (LDCL JWCS) by CFD Analysis)

  • 황기웅;곽효서;김재열;엄태진;김철
    • 대한기계학회논문집A
    • /
    • 제41권11호
    • /
    • pp.1077-1084
    • /
    • 2017
  • 기존의 선박용 디젤 엔진에는 항상 일정한 엔진 부하량을 유지하는 캠 구동장치가 적용되고 있었으나, 최근 환경규제로 인하여 엔진 부하량에 따라 실린더 온도를 개별적으로 제어하는 LDCL(Load dependent cylinder liner) JWCS(Jacket water cooling system)가 적용된 전자유압 제어방식이 개발되었다. 이 시스템에서 3-way 밸브는 실린더의 상부와 하부와의 온도 차이를 줄여 저온부식을 방지하는데, 대부분 수입에 의존하고 있으며 토출유량이 낮다. 이에 본 연구에서는 3-way 밸브 내부 형상 관련 설계인자가 성능(토출 유량 및 온도)에 미치는 영향을 파악하여 밸브의 형상 설계를 수행하였으며, 기존 모델과의 성능 비교를 통해 제안된 밸브의 우수성을 검증하였다.

Empirical Modeling of Fouling Rate of Milk Pasteurization Process : A case study

  • Budiati, Titik;Wahyono, Nanang Dwi;Hefni, Muh.
    • International journal of advanced smart convergence
    • /
    • 제4권1호
    • /
    • pp.11-17
    • /
    • 2015
  • Fouling in heat exchanger becomes a major problem of dairy industry and it increases the production cost. These are lost productivity, additional energy, additional equipment, chemical, manpower, and environmental impact. Fouling also introduces the risk of food safety due to the improper heating temperature which allow the survival of pathogenic bacteria in milk, introducing biofilm formation of pathogenic bacteria in equipments and spreading the pathogenic bacteria to milk. The aim of this study is to determine the fouling rate during pasteurization process in heat exchanger of pasteurized milk produced by Village Cooperative Society (KUD) "X" in Malang, East Java Indonesia by using empirical modeling. The fouling rate is found as $0.3945^{\circ}C/h$ with the heating process time ranged from 0 to 2 hours and temperature difference (hot water inlet temperature and milk outlet temperature) ranged from 0.654 to $1.636^{\circ}C$. The fouling rate depends on type and characteristics of heat exchangers, time and temperature of process, milk type, age of milk, seasonal variations, the presence of microorganism and more. This results will be used to plan Cleaning In Place (CIP) and to design the control system of pasteurization process in order to maintain the milk outlet temperature as standard of pasteurization.

엔진구동 지열 열펌프의 성능 분석(III) - 대체냉매를 이용한 증기압축식 열펌프의 운전특성 - (Performance Analysis of an Earth Coupled Heat Pump System Operated by an Engine(III) - Operating Characteristics of a Vapour Compression type Heat Pump Using Alternate Refrigerant -)

  • 김영복;이승규;김성태;송대빈;강호철
    • Journal of Biosystems Engineering
    • /
    • 제24권6호
    • /
    • pp.513-522
    • /
    • 1999
  • This study was performed to get the optimal operating conditions of an water-air compact heat pump system using R-134a. The experiments was done for three elvels of the air mass flow rate and the compressor driving speed during air-heating process. The temperature of the air at the condenser inlet and outlet was 17~23$^{\circ}C$, 36~44$^{\circ}C$, respectively. The average temperature of the refrigerant at the evaporator and condenser was 1$0^{\circ}C$, 6$0^{\circ}C$, respectively. The temperature of the refrigerant was not depending on the air mass flow rate and the compressor driving speed. The pressure of the refrigerant at the condenser inlet and outlet was ranged of 10~18.5kg/$\textrm{cm}^2$ and that at the evaporator was ranged of 3.1~3.3kg/$\textrm{cm}^2$. The pressure drop at the condenser and evaporator was about 1.5, 1.2 kg/$\textrm{cm}^2$, respectively. The performance of coefficient for air heating was about 3.3~4.0.

  • PDF

Development of Gas Turbine Simulation Program Based on CFD

  • Jin, Sang-Wook;Kim, Jae-Min;Kim, Kui-Soon;Choi, Jeong-Yeol;Ahn, Iee-Ki;Yang, Soo-Seok
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.150-156
    • /
    • 2008
  • A program based on a 2-D CFD code has been developed to simulate a gas turbine engine. 2-D Navier-Stokes implicit code with $k-\omega$ turbulent model is used in compressor and turbine. Lumped method chemical equilibrium code with 10 species of molecular is applied to combustor with assuming perfect mixture and 100% combustion efficiency at constant pressure state. Fluid properties are shared on interfaces between engine components. Compressor supplies outlet temperature and pressure to combustor. At the same time, combustor also carries temperature and pressure to turbine. The back pressure of compressor outlet is transferred by inlet pressure of turbine. Unsteady phenomena in rotor-stator are covered by mixing-plane method. The running condition of engine can be determined only by given the inlet condition of compressor, the outlet condition of turbine, equivalence ratio and rotating speed.

  • PDF

Temperature Control of an Oil Cooler System For Machine Tools Using a Fuzzy- Logic-Based Algorithm

  • Kim, Sun-Chul;Hong, Dae-Sun;Lee, Choon-Man;Kim, Gyu-Tak
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1006-1011
    • /
    • 2004
  • Recently, technical trend in machine tools is focused on enhancing of speed, accuracy and reliability. Such high speed usually results in thermal displacement and structural deformation. To minimize such thermal effect, most precision machine tools adopt high precision cooling system. This study proposes a temperature control for an oil cooler system using PI control with fuzzy logic. In a cooler system, the refrigerant flow rate is controlled by rotational speed of the compressor, where the outlet oil temperature is selected as the control variable. The fuzzy control rules iteratively correct PID parameters to minimize the error, difference between the outlet temperature and the reference one. Here, the ambient temperature is used as the reference one. To show the effectiveness of the proposed method, a series of experiments are conducted for an oil cooler system of machine tools, and the results are compared with the ones of a conventional PID control. The experimental results show that the proposed method has advantages of smaller overshoot and smaller steady state error.

  • PDF

주기관 쟈케트냉각수 온도를 위한 피드포워드 제어시스템의 구성과 분석 (Configuration and Analysis of a Feed-forward Control System for Jacket Cooling Water Temperature of Marine Prime Diesel Engine)

  • 최순만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권8호
    • /
    • pp.1303-1308
    • /
    • 2008
  • Keeping cooling water temperature higher within the allowable range helps marine engines to run in more efficient condition especially when the engine load is low. Temperature control of jacket cooling water in outlet side of main engine has been more widely adopted to ships these days for the purpose to reduce fuel consumption rate. But If the temperature sensor for the control loop is placed at the outlet of engine, it brings more difficulties in attaining stable and desirable properties due to dead times included in pipe length and engine itself comparing to the case where the measuring point is at the inlet side of main engine. In relation with this problem, Feed-forward control could be one of realistic solutions as it reveals good properties and requires less cost for system configuration. This study suggests a forward control system which leads to improved temperature control performances to disturbance signals which could arise from variation of engine load or weather condition. Two dead times in the modelling were described, considering pipe length between the actuator and the engine as well as the thermal process inside the engine. The results of analysis were shown by simulations to confirm responses under different conditions.