• Title/Summary/Keyword: Outlet Pressure

Search Result 844, Processing Time 0.021 seconds

Conversion of Total Atrio-pulmonary Connection to Total Cavo-pulmonary Connection - Review of Indications and Hemodynamic Characteristics - (심방-폐동맥 문합술 후 총 체정맥-폐동맥 문합술로의 전환 - 수술 적응증 및 혈역학적 특징의 검토 -)

  • Seo, Jung Ho;Lee, Jong Kyun;Choi, Jae Young;Sul, Jun Hee;Lee, Sung Kyu;Park, Young Whan;Cho, Bum Koo
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.2
    • /
    • pp.199-207
    • /
    • 2002
  • Purpose : Since the successful application of total atrio-pulmonary connection(TAPC) to patients with various types of physiologic single ventricles in 1971, post-operative survival rates have reached more than 90%. However some patients have been shown to present with late complications such as right atrial thrombosis, atrial fibrillation and protein losing enteropathy eventually leading to re-operation to control the long-term complications. The aim of this study is to review the results of total cavo-pulmonary connection(TCPC) in cases with late complications after TAPC. Methods : Between Jan. 1995 and Dec. 2000, 6 patients(5 males and 1 female) underwent cardiac catheterization $11{\pm}3$ months after conversion of previous TAPC to TCPC. We compared the hemodynamic and morphologic parameters before and after TCPC and also assessed the clinical outcomes. The indications for TAPC were tricuspid atresia in 4 cases and complex double-outlet right ventricle with single ventricle physiology in 2 cases. Results : There was no peri-operative mortality and all patients were clinically and hemodynamically improved at a mean follow-up of 11 months(range : 4 to 13). However, protein losing enteropathy recurred in 2 patients; this was were successfully treated with subcutaneous administration of heparin. Right atrial pressure before TCPC was $18.0{\pm}3.6mmHg$, but baffle pressure, corresponding to right atrial pressure decreased to $14.8{\pm}3.6mmHg$ after TCPC. The size of the pulmonary arteries did not regress after TCPC. Conclusion : The conversion of TAPC to TCPC improves clinical and hemodynamic status by decreasing the right atrial pressure and by providing a laminar cavo-pulmonary flow which enhances the effective pulmonary circulation in the so-called Fontan circulation.

The Effects of Ginseng Saponin on Relaxation of Smooth Muscle in the Lower Urinary Tract and the Corpus Cavernosum (인삼 사포닌이 하부요로와 음경해면체 평활근의 이완작용에 미치는 효과)

  • Jung, Hee-Chang;Oh, Tae-Hee
    • Journal of Yeungnam Medical Science
    • /
    • v.23 no.1
    • /
    • pp.52-61
    • /
    • 2006
  • Background: Korean ginseng (KG) has been used as a general tonic, and for voiding dysfunction for a long time in oriental society. However, scientific basic studies on the use of KG, have been rare, especially for voiding and erectile dysfunction. This study was performed to investigate the effects of KG on voiding and erectile function by examining the effects of total saponin (TS) on the bladder, urethral and penile cavernosal smooth muscle. Materials and methods: To examine the effects of TS, NewZeland white rabbits were used to obtain tissue strips from the smooth muscle of the bladder, proximal urethra and corpus cavernosum. Adult Sprague Dawley rats were used to examine the changes in urodynamic findings and penile erection after administration of TS. Results: In proximal urethral strips, the rate of relaxation of the proximal urethra was increased from $9.0{\pm}2.9$ to $33.7{\pm}4.8%$ in a dose-dependent manner when the concentration of TS was added accumulatively from 0.25 mg/ml to 4.0 mg/ml (p<0.05). However, no significant response was observed in the bladder strips within these concentration ranges. For the corpus cavernosal strips, the rate of relaxation ranged from $5.8{\pm}2.1$ to $36.7{\pm}5.8%$, increasing in a dose-dependent manner when TS was increased from 1.0 mg/ml to 4.0 mg/ml (p<0.05). After administration of 0.1 ml of TS (32 mg/ml) in the rat, the bladder pressure was $37.5{\pm}8.5$ mmHg at $52.1{\pm}7.0$ sec. during isovolumetric bladder contraction, showing no significant differences from $35.7{\pm}7.8mmHg$ and $50.7{\pm}7.2$ sec, respectively, before treatment. However, when 0.1 ml of TS (32 mg/ml) was administered, the relative reduction of urethral pressure was $6.9{\pm}0.5mmHg$ at $62{\pm}7.5$ sec, which was significantly higher compared to $4.6{\pm}1.1mmHg$ at $45{\pm}10$ sec before treatment (p<0.05). For the cavernosal injection study, the change in intracavernosal pressure (${\Delta}ICP$) was examined after administering 0.1 ml of TS. The cumulative additions of TS at concentrations from 0.5 mg/ml to 32 mg/ml increased ${\Delta}ICP$ from $1.3{\pm}0.5$ to $21.3{\pm}7.8mmHg$ in a dose-dependent manner (p<0.05). The duration of tumescence was from $0.3{\pm}0.1$ to $5.2{\pm}0.2$ min, showing dose-dependent increase (p<0.05). Furthermore, the cumulative addition of TS at concentrations from 0.5 mg/ml upto 32 mg/ml did not cause any significant change in systemic blood pressure. Conclusion: These results suggest that ginseng improves voiding functions, which is mainly achieved by TS relaxing the proximal urethra, the most important part of the bladder outlet function. In addition, ginseng safely induced a penile erection hemodynamically by relaxing the corpus cavernosum.

  • PDF

Long-term Results of Modified Lecompte Procedure for the Anomalies of Ventriculoarterial Connection (심실대혈관 연결 이상에 대한 변형된 Lecompte 술식의 장기 성적)

  • 임홍국;한국남;김웅한;이정렬;노준량;김용진
    • Journal of Chest Surgery
    • /
    • v.37 no.9
    • /
    • pp.727-734
    • /
    • 2004
  • The Lecompte procedure for transposition of the great arteries has an advantage because it obviates the need for an extracardiac conduit for the reconstruction of the pulmonary outflow tract. We evaluated the effectiveness and the application of the Lecompte procedure. Material and Method: A retrospective review was conducted of the records of 46 patients who underwent the Lecompte procedure during the past 15 years. Mean age at operation was 29.2$\pm$20.3 (range: 3∼83) months. The diagnoses involved anomalies of the ventriculoarterial connection with ventricular septal defect and pulmonary outflow tract obstruction, such as transposition of the great arteries, double-outlet right ventricle, and double-outlet left ventricle. Result: Early mortality was 4.4% (2 of 46 patients) and late mortality was 6.8% (3 of 44). The mean follow-up was 11.2$\pm$6.9 years. Eighteen patients (43.9% of survivors, n=41) had pulmonary stenosis (pressure gradient above 30 mmHg), the main reason for which was a calcified monocusp valve (n=15, 83.3%). Seventeen of 46 patients (37.0%) underwent reoperation: 15 for pulmonary stenosis, 5 for residual ventricular septal defect, 4 for left ventricular outflow tract obstruction, 3 for pulmonary insufficiency, and 4 for other causes. The cumulative survival rates were 91.3$\pm$4.2%, and 87.0$\pm$5.8% at 10 and 15 years, respectively. The actuarial probabilities of freedom from reoperation for pulmonary stenosis were 90.6$\pm$4.5%, 73.9$\pm$7.3%, and 54.0$\pm$10.4% at 5, 10, and 15 years, respectively. Conclusion: The Lecompte procedure is an effective treatment modality. Repair in early age is possible with acceptable morbidity and mortality, but recurrent right ventricular outflow tract obstruction caused by degeneration of the monocusp valve is a problem that needs resolution.

A Study on the Removal of Ammonia by Using Peat Biofilter (미생물 활성토탄을 이용한 암모니아 제거에 관한 연구)

  • Choung, Youn Kyoo;Ahn, Jun Seong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.655-668
    • /
    • 1994
  • Conventional deodorization filters using soil and compost reach the capacity limitation of deodorization in short period, because its removal mechanism primarily depends on adsorption. Therefore, in this study the experiment was performed on the removal of ammonia which is a strong inorganic malodor, frequently emitted from night soil treatment plants and sewage treatment plants, by seeding activated sludges on the bio-peat containing higher organic contents, water conservation capacity, permeability and lower pressure drop. As a result, in raw peat filter natural ammonia outlet was observed in consequence of pH increase resulted from ammonia ionizing in liquid phase. Ammonia removal mechanism primarily depended on the adsorption onto the anion colloidal substances in peat. In peat bio-filter, theoretical ammonium salts ratio was higher than that of raw peat, resulted from slight pH increase by microorganism activity, however, the experimetal value of ammonia-nitrogen accumulated in bio-peat was lower than that of raw peat because of nitrification by nitrifying bacteria. In the initial reaction period, adsorption was predominant in the ammonia removal mechanism, but nitrification was conspicuous after the middle period. Mass balance of nitrogen was established using experimental data of input $NH_3$ loading, output $NH_3$ loading, $NH_4{^+}$-N, $NO_x$-N, and Org-N. The critical time of unsteady state, which is the maximum activating point of microorganism in bio-filter, was determined using experimental data, and the ammonia adsorption curve was computed using regression analysis. On the basis of the results obtained by above analysis, the delay days for the saturation of adsoption capacity in peat bio-filter was calculated.

  • PDF

Numerical Simulation of External Gear Pump Using Immersed Solid Method (Immersed Solid Method 를 이용한 외접형 기어 펌프의 수치해석)

  • Yoon, Yong Han;Park, Byung Ho;Han, Yong Oun;Hong, Byeong Joo;Shim, Jaesool
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.1
    • /
    • pp.95-101
    • /
    • 2014
  • In this study, an ISM (immersed solid method) was used for investigating the mass flow rate and efficiency of an involute-gear pump featuring very high rotational speed. For considering circulation flow at the gear pump and housing, fluid flow was assumed as turbulent, and the rotational speed of the gear pump increased under the condition of constant pressure at both the inlet and outlet. The efficiency and mass flow rate of the gear pump were studied by varying its rotational speed and the clearance between the gear tip and the housing. In the simulation results, as the rotational speed were increased, the average mass flow rate and efficiency increased. Furthermore, as the clearance between the gear tip and the housing was increased, the average mass flow rate and efficiency decreased. The efficiency was 85.11, 90.94, and 93.62 at rotational speeds of 6,000 rpm, 8,000 rpm, and 10,000 rpm, respectively, under the condition that there was no clearance. In addition, the efficiency was 93.62, 93.29, and 92.74 at clearances of 0 m, 0.00001 m, and 0.00003 m respectively.

Forging Die Design for Vent Forming of Square Cup Battery Case (사각 컵 배터리 케이스 바닥 벤트 성형을 위한 단조 금형 설계)

  • Lee, Sang-Hoon;Kwon, Soon-Ho;Chung, Hoon;Hong, Seokmoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.330-335
    • /
    • 2017
  • The demand for electric motor fuel cells has surged in the automotive industry, leading to a recent increase in the demand for square aluminum cans used as fuel cell battery casings. The air vent located on the bottom of the rectangular battery casing prevents large explosions by intermittent pressure release prior to the accumulation of abnormally high pressures. Conventionally, the square cup battery casing is produced via six-step deep drawing, with the outer shape of the vent being manufactured by welding to the square battery casing. On the other hand, this study directly incorporated the air vent outlet into the bottom surface of the rectangular casing. The product of a coupled finite element analysis technique applying the thickness and contour generated from the square cup multi-step deep drawing formation analysis was used as the forging input shape. The results yielded increased prediction accuracy and the advanced prediction of defects, such as swelling and fracture. Based on the results of the initial analyses, two of the generated forging shapes were determined to be suitable, with the optimal forging shape being determined by molding analysis. The results presented here were validated by mold fabrication and a subsequent comparison of the actual and analytical results.

Development of Portable Preconcentration-Gas Chromatography System for Fast Analysis of Trace Benzene, Toluene and Xylene in Air (대기 중 극미량의 벤젠, 톨루엔 및 자일렌의 신속한 분석을 위한 휴대용 농축-기체 크로마토크래피 시스템 개발)

  • Jung, Young-Rim;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.432-441
    • /
    • 2001
  • An automated on-line portable preconcentration-short column gas chromatograph was developed, which used preconcentrator using adsorption tube with Tenax-GR and Curie-point heating. The developed system operated with 3 steps of processing, preconcentration, thermal desorption, and analysis and cleaning, and could continued operating within 1~2 min cycle. The recoveries of preconcentrator for toluene was ranged between $94.7{\pm}6.6%$ and $103.8{\pm}3.1%$ with less than 7% of RSD. For benzene, toluene and xylene(BTX) standard gas test, IDL was 41, 49, $472ng/m^3$ benzene, toluene and o-xylene, respectively. The BTX mixture was analyzed within 30 sec with baseline separation by the system equipped with 4 m long capillary column. The deficiency of separation power caused by short column was solved by the control of sample injection volume and inlet/outlet pressure ratio. The automated portable preconcentration-short column gas chromatograph system was found to be useful for the continuous air monitoring of BTX at ppb levels in ambient air.

  • PDF

A Study on the Heat Flow Analysis of Infra-Red Signature Suppression System for Naval Ship (함정 적외선 신호저감 장치의 열 유동해석 연구)

  • Yoon, Seok-Tae;Cho, Yong-Jin;Ko, Dae-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.740-746
    • /
    • 2017
  • Infrared signatures emitted from hot exhaust gases generated by the internal combustion engine and generator of naval ships and from the metal surfaces of the funnel have become the targets of infrared homing missiles, which is the main cause of a reduced survivability of naval ships. The infrared signatures from the exhaust gas and the metal surface of a funnel can be reduced by installing an infrared signature suppression (IRSS) system on a ship. The IRSS system consists of three parts: an eductor that generates turbulent flow of the exhaust gas, a mixing tube that mixes the exhaust gas with ambient air, and a diffuser that forms an air film using the pressure difference between the inside and outside air. As a basic study to develop an IRSS system using domestic technology, this study analyzed the model test conditions of an IRSS system developed by an overseas engineering company and installed on a domestic naval ship, and a numerical heat-flow analysis was conducted based on the results of the aforementioned analysis. Numerical heat-flow analysis was performed using a commercial numerical-analysis application, and various turbulence models were considered. As a result, the temperature and velocity of the exhaust gas at the educator inlet and diffuser outlet and that of the metal surface of the diffuser were measured, and found to agree well with the measurement results of the model test.

Simulation on Concentration of CH4 Using Hollow Fiber Membrane Permeator with Countercurrent Flow (향류 흐름 중공사 분리막의 메탄 농축 수치해석)

  • Seo, Yeonhee;Lee, Seungmin;Park, Sungeun;Jung, Woojin;Kim, Jeonghoon;Lee, Yongtaek
    • Membrane Journal
    • /
    • v.24 no.3
    • /
    • pp.223-230
    • /
    • 2014
  • A numerical analysis was performed for concentration of methane from the biogas using a polysulfone hollow fiber membrane permeator. Governing equations were derived for the countercurrent flow and numerically solved by using the Compaq Visual Fortran 6.6 software. When the methane mole fraction of feed was 0.5, the mole fraction of retentate increased from 0.5 to 0.8; the normalized retentate flow rate to the feed flow rate decreased from 1.0 to 0.57 at the given typical operating condition as the feed gas flowed from the inlet to the outlet of the membrane. As the methane mole fraction of feed was changed to 0.9, the methane mole fraction of retentate became 0.93 and the normalized retentate flow rate was changed to 0.91. When the pressure ratio of the permeate to the feed was varied from 0.33 to 0.17, there was a little difference in the methane mole fraction of retentate for the low stage cut of 0.1, whereas there was an significant increment for the high stage cut of 0.3. The retentate methane mole fraction remained relatively high despite the change of a stage cut as the area of the membrane increased from $1.14m^2$ to $2.57m^2$.

Factors influences on early and late results of modified fontan operation (변형 Fontan수술의 수술결과 및 장기결과에 미치는 영향에 관한 연구)

  • Jang, Byeong-Cheol;Park, Yeong-Hwan;Jo, Beom-Gu
    • Journal of Chest Surgery
    • /
    • v.19 no.4
    • /
    • pp.569-577
    • /
    • 1986
  • Between October 1979 and June 1986, modified Fontan procedures have been performed on 22 patients by the Department of Thoracic and Cardiovascular Surgery, Yonsei University College of Medicine. Twelve patients had tricuspid atresia; one, congenital tricuspid stenosis; five, single ventricle; two, I-transposition of the great vessels; one, double outlet right ventricle, and one, pulmonary atresia with an intact ventricular septum. There were 9 operative deaths [mortality; 40.9%]. The causes of death were right heart failure in six patients and pulmonary venous hypertension in one who misdiagnosed preoperatively. Another two were deceased due to sepsis and cerebrovascular accident at postoperative 35 and 34 days in each. There were 7 patients below 4 years of age at the time of operation and among them 4 patients were deceased. The operative death was not related with patients` age above and below 4[p=0.211]. The relation between operative death of tricuspid anomaly and another cardiac malformations was statistically significant [p=0.048]. The operative procedures with or without valved conduit [woven dacron] was related significantly [p=0.043] in the case of the 21 of the patients, but the modified Fontan operation with a valved conduit was performed early stage in this series. Since 1982, we operated on 4 patients, doing a right atrium-right ventricle anastomosis without a conduit. All survived and remained in functional class I [NYHA]. The right atrial pressure [RAP] was elevated significantly after operation [mean 9.9$\pm$4.8 ~16.9$\pm$3.6 mmHg, p<0.001]. The relation between the postoperative RAP of the survival group [16.5$\pm$4.3 mmHg] and the group who died [17.4$\pm$2.2 mmHg] was statistically significant [p=0.047]. There was no relation between any operative death and any previous palliation. All patients were followed for 4 months to 80 months, except one who was lost to follow up at 2 months following surgery [mean 11.4 months, 238 patient. months]. All were in functional class I with 5 on medications and 7 not. One was reoperated at 70 months following the first operation, due to conduit stenosis. She was moderately impaired in activity, with hepatomegaly after the second operation.

  • PDF