• Title/Summary/Keyword: Outlet Performance

검색결과 739건 처리시간 0.024초

지열을 이용한 공조외기부하저감 시스템에 관한 연구 - 공기식 집열기와의 병용에 의한 공조외기부하저감 효과 - (Study on Fresh Air Load Reduction System by Using Geothermal Energy - Reducing Effect of a Fresh Air Load by Combining with Air-heated Solar Collector -)

  • 손원득;이성
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1218-1226
    • /
    • 2004
  • This paper presents thermal behaviors and performances of a fresh air load reduction system by using earth tube system combined with air-heated solar collector. The earth tube system reduces a fresh air load by heat exchange with soil throughout the year. In the previous experimental research, it was clarified that the earth tube system was very useful as a fresh air load reduction system. However, since outlet temperature of the fresh air which was heated by earth tube system was below 15$^{\circ}C$ in winter, it is not suitable to introduce the fresh air into the place of residence directly. Therefore, a simulation model using the simple heat diffusion equation was used to examine a rising effect of outlet air temperature in winter by combining with air-heated solar collector. An improvement of annual performance by control of operation is also quantitatively examined. In conclusion, it is confirmed that its performance is improved by control of operation throughout the year and outlet air temperature rose by combining with air-heated solar collector.

저항성 누설전류(Igr) 검출 콘센트의 개발 및 안전성 평가 (Development and Safety Estimation of Resistive Leakage Current(Igr) of Detection Outlet)

  • 김창성;한송엽;최충석
    • 전기학회논문지P
    • /
    • 제58권2호
    • /
    • pp.221-226
    • /
    • 2009
  • In this paper, we analyzed form of flowing leakage current in electrical installation. Leakage current ($I_g$) is consisted of resistive leakage current($I_{gr}$), capacitive leakage current($I_{gc}$), and inductive leakage current($I_{gl}$). Resistive leakage current($I_{gr}$) is big occasion than capacitive leakage current($I_{gc}$) in system, Residual Current Protective Device(RCD) detects correctly leakage current. But,$I_{gc}$ is big occasion than $I_{gr}$, RCD is malfunctioned It is resistance to lead to electric fire in electrical device. We manufactured outlet that resistive leakage current detecting circuit is had. Manufactured outlet displayed performance exactly in leakage current of 5 mA Therefore, this product estimates that contribute on electric fire courtesy call.

데시칸트 제습기용 열교환기 설계에 관한 수치해석적 연구 (A Numerical Study on the Design of Exchanger for Desiccant Dehumidifier)

  • 김치완;안영철;김길태
    • 동력기계공학회지
    • /
    • 제17권6호
    • /
    • pp.54-62
    • /
    • 2013
  • A numerical analysis is performed to evaluate mass flow balance in the heat exchanger for the dehumidifier. To improve the mass flow balance for maximum heat transfer performance, inlet, outlet and baffle are changed. Mass flow balance is evaluated by non-uniformity of flow which is the same concept with the standard deviation. Usually, there will occur many paths between the inlet and the outlet, however, it will follow shortest and low resistance ways. The uniform distribution of flow is numerically analyzed for several types of heat exchangers. Making the shortest way between the inlet and the outlet is most important factor. Two types of heat exchangers are installed in the dehumidifier and 4 cases of Type A heat exchangers and 3 cases of Type B heat exchangers are evaluated and optimized. The result of this research is applied to design heat exchanger for commercial dehumidifiers.

인젝터 노즐 형상이 노즐 내부 유동 및 출구 특성에 미치는 영향 (Influences of Injector Nozzle Shape on Nozzle Internal Flow and Outlet Characteristics)

  • 김창현;이강수;박재인;백제현
    • 한국자동차공학회논문집
    • /
    • 제21권6호
    • /
    • pp.108-116
    • /
    • 2013
  • Diesel engine injector is used for spraying the fuel into the cylinder chamber. Complex phenomenon like cavitation occurs from small scale domain, highly pressurized condition and rapid injection. Flow inside the nozzle affects the whole engine performance including combustion and exhaust, therefore understanding the flow inside the injector nozzle is very important. In this paper, cylindrical and convergent-divergent nozzles are suggested for nozzle types and their influences on nozzle internal flow and nozzle outlet characteristics will be analyzed by changing their outlet diameters.

FUZZY PID 방법을 이용한 개별 공조시스템의 급기온도 제어 (A FUZZY PID Control of Supply Duct Outlet Air Temperature for PEM)

  • 장영준;박영철;정광섭;한화택;이정재
    • 설비공학논문집
    • /
    • 제14권4호
    • /
    • pp.278-284
    • /
    • 2002
  • The work presented here provides a control of the supply duct outlet air temperature in PEM (personal environment module) using fuzzy PID controller. In previous work, PID control systems were used, but the result shows that the outlet air temperature and electric heater regulating voltage were oscillated. Fuzzy PID control systems are designed to improve the system response obtained using PID control and implemented experimentally Also, PID controller and fuzzy controller without PID logic are provided to compare the result with that of the fuzzy PID controller. Data obtained shows that the fuzzy PID control system satisfies the design criteria and works proper1y in controlling the supply air temperature. Also it has bettor performance than the previous result obtained using PID control.

압력 평형식 온도조절 밸브 성능 향상을 위한 연구 (A Study on the Performance Improvement of Pressure Compensating Temperature Control Valve)

  • 김태안;김윤제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.671-674
    • /
    • 2002
  • Pressure compensating temperature control valve(TCV) is one of the important control devices, which is used to maintain the constant temperature of working fluid in power and chemical plants. The ratio of cylinder hole diameters of inlet and outlet is the main design parameters of TCV. So this needs to be investigated to improve the function of control of temperature and void fraction. In this study, numerical analysis is carried out with various ratios of cylinder hole diameters of the inlet and outlet in the TCV. Especial1y, the distribution of the static pressure Is investigated to calculate the new coefficient($C_{\upsilon}$) and resistance coefficient(K). The governing equations are derived from making using of three-dimensional Naver-Stokes equations with standard $k-{\varepsilon}$ turbulence model and SIMPLE algorithm. Using a commercial code, PHOENICS, pressure and flow fields in TCV are calculated with different inlet and outlet diameters of the cylinder hole for cold and hot water passages.

  • PDF

입.출구의 고차모드를 고려한 사각형 단순확장관의 음향해석 (ACOUSTIC ANALYSIS OF RECTANGULAR SIMPLE EXPANSION CHAMBER WITH CONSIDERATION OF HIGHER ORDER MODE OF INLET/OUTLET)

  • 이정환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권6호
    • /
    • pp.748-754
    • /
    • 1999
  • The acoustic performance of reactive type single expansion chamber can be calculated theoretically by plane wave theory. But higher order modes should be considered to widen the frequency range. Munjal has suggested the method for analyzing the acoustic properties of simple expansion chamber with taking into consideration of higher order mode of inlet/outlet. But his method cannot predict the acoustic properties exactly when the dimensions of inlet/outlet and expansion chamber have not integer multiples. In this paper the new method was suggested to overcome the shortcomings of Munjal's method The predictions by this method were also compared with those by the finite element method.

  • PDF

헬리컬형 분자 드래그 펌프의 유동특성에 관한 연구 (A Study on the Pumping Performance of a Helical-type Molecular Drag Pump)

  • 김도행;권명근;황영규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2723-2728
    • /
    • 2008
  • The present study is numerically and experimentally performed to reveal the pumping characteristics of a helical-type molecular drag pump (HTDP) in the molecular transition flow region. In the experimental study, the pressures are measured simultaneously at the 5 positions along the helical channel of rotor under various conditions of outlet pressure and throughputs, and nitrogen is used as test gas. The outlet pressure is in the range of 26-533 Pa. As results, the local pressure changes are checked corresponding to the various outlet pressure and throughput of HTDP. In the numerical study, Navier-Stokes equations with slip boundary conditions are employed (Re< 1000, Kn< 0.1). The local pressure distribution and the pumping speed are calculated. The numerical results are compared with the experimental results. The numerically computed value agrees with the experimental data within an error of approximately 5%.

  • PDF

벼의 횡류 연속식 건조 모델 개발 (Development of Continuous Cross-Flow Rice Drying Model)

  • 송대빈;고학균
    • Journal of Biosystems Engineering
    • /
    • 제22권3호
    • /
    • pp.279-288
    • /
    • 1997
  • This study was worked out to obtain fundamental data needed for developing a continuous type dryer. The drying process in a cross-flow type continuous dryer was expressed as partial differential equations, and a drying simulation model for predicting rice moisture content, rice temperature, drying air absolute humidity, drying air temperature was developed by using the finite difference method. To validate the performance of the drying simulation model, a prototype continuous dryer was constructed in this study. The size of the test dryer was one-tenth to that of a commercial continuous dryer. The difference in the outlet rice moisture content between the predicted values and the measured values was within 0.5%, that of outlet rice temperature was below $3^{\circ}C$, that of drying air temperature in drying bed was within $8^{\circ}C$ and that of relative humidity of outlet drying air was big because of the different measuring point. In addition, a drying simulation model for a actual size continuous dryer with double flow was developed in this study. This drying simulation model included the rice mixing effect in the middle of drying length. The difference of outlet moisture content between the predicted and the measured values showed below 0.5% in this study.

  • PDF

${\cdot}$출구 위치 변화에 따른 압전 구동방식 마이크로 펌프의 성능특성에 관한 수치해석적 연구 (A Numerical Study on the Performance Characteristics of a Piezoelectric Micropump for Different Inlet and Outlet Positions)

  • 김동희;정진;김창녕
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.33-38
    • /
    • 2005
  • This study has been conducted to investigate flow characteristics of a micropump with piezoelectric materials. In this study, the change of flow rates has been investigated for different positions of the inlet and outlet and for different distances between them. The FSI(Fluid Structure Interaction) method has been employed for numerical analysis of the piezoelectric diffuser/nozzle based micropump. It has been found that time averaged flow rate is greater in the case that distance between the inlet and outlet is longer. For the cases where the positions of the inlet are different with the position of the fixed outlet at the center, the flow rate is increased as the inlet is located farther from the center. This study may supply fundamental understandings for the design and analysis of the prototypes of piezoelectric micropumps.