• Title/Summary/Keyword: Outlet

Search Result 2,623, Processing Time 0.027 seconds

Double Outlet of Right Ventricle in Criss-Cross Heart -Surgical Experience of One Case (십자형심장에 동반된 양대혈관우심실기시증 -수술치험 1례)

  • Kim, Dae-Yeon;Jo, Seong-Rae;Park, Seong-Dal;Jeong, Hyeon-Gi
    • Journal of Chest Surgery
    • /
    • v.30 no.12
    • /
    • pp.1242-1246
    • /
    • 1997
  • Criss-cross heart which is a cardiac malformation caused by abnormal rotation of the ventricles early in embryonic development, is rare but a double outlet of right ventricle in priss-cross heart is very rare. We experienced a case of criss-cross heart which is situs solidus, concordant atrioventricular connection and double outlet of rig t ventricle with remote ventricular septal defect of perimembranous inlet type. A 4-years old female was diagnosed as a double outlet of right ventricle in criss-cross heart after echocardiography, cardiac catheterization and cardiac angiography. The surgical correction was a intraventricular reconstruction of left ventricular outflow with 314 circle of 20 mm Hemashield vascular graft from the ventricular septal defect to the aorta. The patient had a temporary atrioventricular block but was recovered uneventfully, and a postoperative echocardiogram showed no left ventricular outflow obstruction, no intracardiac shunt.

  • PDF

Management of Ponding Depth and Discharge Filtration from Paddy Fields for Controlling Non-point Source Pollution (논 비점오염 저감을 위한 담수위 관리와 배출수 여과의 효과 분석)

  • Choi, Yonghun;Kim, Youngjin;Kim, Seounghee;Kim, Minyoung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.6
    • /
    • pp.125-130
    • /
    • 2015
  • Field study was carried out to assess the effect of automatic inlet and filtration outlet to reduce non-point source discharge and save agricultural irrigation water from paddy. The comparison of control and treated plots showed that irrigation water was saved up to 58 mm and discharge water was reduced up to 110 mm. The filtration outlet improved the discharge water quality for SS, COD, TN and TP up to 60.1 %, 0.1 %, 4.5 %, and 26.0 %, respectively. Overall, the findings of this study indicated that non-point source pollution discharged from paddy fields where automatic inlet and filtration outlet were installed could be reduced 266.3 kg/ha/yr in SS, 10.3 kg/ha/yr in COD, 1.22 kg/ha/yr in TN, and 0.10 kg/ha/yr in TP, respectively. This clearly showed that the automatic inlet and filtration outlet are effective management method for saving of agricultural water and protecting water environment.

Experimental analysis on effects of nozzle diameter on detection characteristics of an optical particle counter (광학식 입자 계수기 내 샘플 노즐 직경이 측정 효율 및 특성에 미치는 영향에 대한 실험적 연구)

  • Song, Hyunwoo;Kim, Taewook;Song, Soonho
    • Particle and aerosol research
    • /
    • v.13 no.4
    • /
    • pp.159-164
    • /
    • 2017
  • The detection efficiency and characteristics of an optical particle counter (OPC), with various sample nozzle outlet diameters, were experimentally investigated. The OPC system, which was built with original design, was made up of a diode laser, two photodetectors, and a variety of optics such as a beam splitter and a concave mirror. The cone-shaped sampling nozzle was designed to be changeable to alter the outlet diameter, within the range of 1 to 3 mm. For samples, sets of polystyrene latex (PSL) standard particle with various sizes of 1 to $3{\mu}m$, were used. As a result, detection efficiency of the OPC greatly decreased with larger nozzle outlet diameter. Moreover, increased nozzle outlet diameter means broader sample flow, thus caused light interference and multiple scattering which results in abnormal high peaks in scattered light signal. The ratio of abnormal peaks to regular signal of single particle increased with larger nozzle outlet diameter.

A Study on the Inlet NOx Estimation of SCR System in a Refuse Incineration Plant by Using General Structured Observer (일반 구조형 관측기를 이용한 소각장 SCR 시스템의 Inlet NOx 추정에 관한 연구)

  • Lee, Chung-Hwan;Kim, In-Gyu;Kim, Hwan-Seong;Kim, Sang-Bong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.1
    • /
    • pp.123-128
    • /
    • 2001
  • The function of SCR system in refuse incineration plant is to reduce the harmful combustion gases especially NOx which make serious environmental pollution. The SCR system normally have a NOx measurement system such as inlet NOx analyzer and outlet T.M.S.(Tele Monitoring System) to control the outlet NOx in stack. The NOx measurement system is very important, however there are frequently happened sensing problems and it need maintenance periodically. In this paper, we propose an estimation method of inlet NOx of SCR system by using general structured observer. The inlet NOx is considered as an input disturbance and it is modelled by applying FFT method in frequency domains. Through the design of general structured observer, the outlet NOx can be estimated by using observation error between real outlet NOx and estimated outlet NOx. The effectiveness of the proposed method is shown by comparing to a measured inlet NOx data.

  • PDF

Experimental Study on Flow Noise in a T-Junction Pipe at Different Flow Velocity (유동속도에 따른 T-접합관의 유동소음에 관한 실험적 연구)

  • Jian-bin Hu;Hou-lin Liu;Kai Wang;Guang-xin Ding;Yu-bo Jin;He-ming Liu;Hyoung-bum Kim
    • Journal of the Korean Society of Visualization
    • /
    • v.22 no.2
    • /
    • pp.55-62
    • /
    • 2024
  • Using an internal flow noise test bench, this study investigates the variation in internal flow noise at the inlet and outlet monitoring points of a DN100 T-junction pipe under different flow velocities. Results indicate that with increasing flow velocity, both the sound pressure level and total sound pressure level at the inlet and outlet monitoring points increase. The highest total sound pressure level is observed at the vertical outlet monitoring point B, followed by the horizontal inlet monitoring point A, with the lowest at the horizontal outlet monitoring point C. At a constant flow velocity, the sound pressure level at the inlet and outlet points initially increases and then decreases as frequency increases.

Thoracic Outlet Syndrome - One Case Report - (흉곽출구 증후군[TOS];치험 1례)

  • 김흥석
    • Journal of Chest Surgery
    • /
    • v.24 no.12
    • /
    • pp.1192-1196
    • /
    • 1991
  • Thoracic outlet syndrome is very rare thoracic surgical neurovascular disorder which is subject to compression by bones and muscular structures impinging upon the subclavian artery, vein k brachial plexus. The operative therapy is applied to remove the anatomical abnormal structures which leads to the compression to develop symptoms. We have operated one patient with thoracic outlet syndrome by excision of cervical ribs & first ribs with using transaxillary & posterior parascapular approaches in the thoracic surgical department, Yonsei University College of medicine, The post-operative courses has been uneventful for 7 months to now.

  • PDF

Surgical Treatment of Thoracic Outlet Syndrome (흉곽 출구 증후군 수술치험 1례)

  • 서정욱
    • Journal of Chest Surgery
    • /
    • v.27 no.6
    • /
    • pp.506-508
    • /
    • 1994
  • Thoracic outlet syndrome refers to compression of the subclavian vessels and brachial plexus at the superior aperture of the thorax. A 35-year old female was evaluated for right hand numbness. This patient had a history of headache, right shoulder pain, and right hand numbness during 10 months.Preoperative angiography, EMG, and NCV was performed. First rib and cervical rib resection was done with transaxillary approach. After operation, right hand numbness and right shoulder pain were disappeared. Postoperative course was uneventful.

  • PDF

A PID Control of Supply Duct Outlet Air Temperature in Personal Environment Module

  • Park, Young-Chil
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.2
    • /
    • pp.82-90
    • /
    • 2003
  • The work presented here is a design and an implementation of PID control system to regulate a supply duct outlet air temperature in PEM (Personal Environment Module). In PEM, the air is heated to the required temperature while it flows through the supply duct without any mixing chamber. This makes the control of air temperature in PEM difficult. A simulation is done first to understand the relationship between a temperature distribution in working area, flow rate and the outlet air temperature of PEM. Then a linear dynamic model of heating process in PEM is derived. P, PD and PID type control systems, to provide the rapid response without overshoot and saturation in heater command voltage, are designed using a linear model obtained. Experimentally obtained data shows that the control system satisfies the design criteria and works properly in controlling the supply duct outlet air temperature.

Dynamic Characteristics of an Unsteady Flow Through a Vortex Tube

  • Kim, Chang-Soo;Sohn, Chang-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.12
    • /
    • pp.2209-2217
    • /
    • 2006
  • Dynamic flow characteristics of a counter-flow vortex tube is investigated using hot-wire and piezoelectric transducer (PZT) measurements. The experimental study is conducted over a range of cold air outlet ratios (Y=0.3, 0.5, 0.7, and 1.0) and inlet pressure 0.15 MPa. Temperatures are measured at the cold air outlet and along the vortex tube wall. Hot-wire is located at cold outlet and PZT is installed at inner vortex tube by mounting at throttle valve. The cold outlet temperature results show that the swirl flow of vortex tube is not axisymmetric. The hot-wire and PZT results show that there exist two distinct kinds of frequency, low frequency periodic fluctuations and high frequency periodic fluctuations. It is found that the low frequency fluctuation is consistent with the Helmholtz frequency and the high frequency fluctuation is strongly related with precession oscillation.

Development of Water Saving Irrigation Method Using Water Balance Model (물수지 모형을 이용한 절수관개기법 개발)

  • Sohn , Seung-Ho;Chung , Sang-Ok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.5
    • /
    • pp.3-11
    • /
    • 2004
  • The objective of this study is to develop water saving irrigation method using water balance model in order to save rural water. Daily water balance components such as irrigation water, drainage water, effective rainfall, ET, and infiltration were measured in paddy fields. Model simulations were performed for different outlet heights and ponding depths. The outlet heights and the ponding depths are 2 cm, 4 cm, 6 cm, 8 cm, and 10 cm, respectively. Based on the simulation very shallow ponding depth of 2 cm with 10 cm outlet height showed the largest effective rainfall ratio and the smallest irrigation amount. Until the introduction of laser leveling dozer and automatic inlet control devices, it would be desirable to adopt 4cm ponding depth because of difficulty of land leveling and frequency of farmer's field visit. The results of this study will be applied in the paddy farming and can improve water use efficiency.