• Title/Summary/Keyword: Outlet

Search Result 2,616, Processing Time 0.026 seconds

Thoracic Outlet Syndrome(TOS) (흉곽출구증후군)

  • Kang, Jeom-Deok;Park, Youn-Ki
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.9 no.2
    • /
    • pp.5-11
    • /
    • 2003
  • Thoracic outlet syndrome is actually a collection of syndromes brought about by abnormal compression of the neurovascular bundle by bony, ligamentous or muscular obstacles between the cervical spine and the lower border of the axilla. First of all a syndrome is defined as a group of signs and symptoms that collectively characterize or indicate a particular disease or abnormal condition. The neurovascular bundle which can suffer compression consists of the brachial plexus plus the C8 and T1 nerve roots and the subclavian artery and vein. The brachial plexus is the network of motor and sensory nerves which innervate the arm, the hand, and the region of the shoulder girdle. The vascular component of the bundle, the subclavian artery and vein transport blood to and from the arm. the hand. the shoulder girdle and the regions of the neck and head. The bony, ligamentous, and muscular obstacles all define the cervicoaxillary canal or the thoracic outlet and its course from the base of the neck to the axilla or arm pit. Look at the scheme of this region and it all becomes more easily understood. Compression occurs when the size and shape of the thoracic outlet is altered. The outlet can be altered by exercise, trauma, pregnancy, a congenital anomaly, an exostosis, postural weakness or changes. Thoracic outlet syndrome has been described as occurring in a diverse population. It is most often the result of poor or strenuous posture but can also result from trauma or constant muscle tension in the shoulder girdle. The first step to beginning any treatment begins with a trip to the doctor. Make a list of all of the symptoms which seem to be present even if the sensations are vague. Make a note of what activities and positions produce or alleviate the symptoms and the time of day when symptoms are worst. Also, note when the symptoms first appeared. This list is important and should also include any questions one may have.

  • PDF

Analysis of Space Cognition and Use Characteristics on Premium Outlet Shopping Mall -Focused on Exploratory Factor Analysis on Visitor's Behavior- (프리미엄 아웃렛 쇼핑몰의 공간지각 및 이용 특성분석 -방문자의 탐색적 요인분석을 중심으로-)

  • Park, Tae-Won;Lee, Deok-Jo;Park, Seung-Kyoo
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.6
    • /
    • pp.486-496
    • /
    • 2012
  • In recent years, the retail industry has been undergoing major shifts. Outlet malls are an important part of the new retail landscape. This paper seeks to increase the understanding of the shopping experiences of visitors to a Premium outlet shopping mall in Shinsagae Chelsea Premium Outlet at Paju City, Gyeongi-do. This paper analyze the Element of the premium outlet across demographics. It explores seven critical factors which significantly influence customers' perceptions of premium outlet. Findings are base on a mall intercept survey with 292 respondents across a range of demographics. The summary of 7 factor is classified as the visual, location, Shopping support, human traces, mood, transit expedience, and tenant. The main implication of these findings is that factory outlet stores are perceived favourably and that they need to build more positive marketing strategies accordingly.

Quantitative Visualization of Outlet Flow of the Centrifugal Blower (원심 블로어 출구 유동의 정량적 가시화 연구)

  • Tu, Xin Cheng;Kim, Sung-Jun;Park, Seung Ha;Kim, Hyoung-Bum
    • Journal of the Korean Society of Visualization
    • /
    • v.12 no.1
    • /
    • pp.25-29
    • /
    • 2014
  • The outlet flow of the centrifugal blower were quantitatively visualized using particle image velocimetry. Because the centrifugal blower is one of the key parts of electric vehicle battery cooling system, the quantitative information of centrifugal blower is necessary to design and optimize the cooling system. The effect of different inlet flow condition to the outlet flow was investigated in this study. Two different inlet ducts were used. One is the straight inlet and the other is a bended one. The results clearly showed the outlet flow asymmetry in both inlet ducts. When the blower has the bended inlet, the flow rate decreases due to the increase of the head loss.

Numerical Investigation of the Performance of a Heat Exchanger for the Inlet-outlet Area Ratio of Counter Flow Manifold (대향류 매니폴드 입-출구 면적비에 따른 열교환기의 성능특성에 관한 수치적 연구)

  • Kim, Sang-Jo;Chio, Byoung-Ik;Kim, Kui-Soon;Son, Chang-Min;Ha, Man-Young;Jeong, Ji-Hwan;Go, Jeong-Sang
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.269-273
    • /
    • 2011
  • In present paper focused on the influence of the inlet-outlet area ratio of counter flow manifold on the flow distribution and pressure drop characteristics of a tubular heat exchanger. The characteristics of flow distribution and pressure loss can be obtained depending on the inlet-outlet area ratio. In this paper, a tubular heat exchanger can be designed with minimum flow mal-distribution and better characteristic of pressure loss by choosing the optimum inlet-outlet area ratio.

  • PDF

Investigation of Pressure Loss in Bent Duct (Bent Duct 내부 유동의 손실 측정)

  • Roh, U-Jin;Im, Ju-Hyun;Song, Seung-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.295-298
    • /
    • 2009
  • Bent ducts add loss and decrease efficiency. Many researchers have been conducted the performances of bent ducts, but their shapes of inlet and outlet are same. However, in this investigation, the focus is on a bent duct which is annular at the inlet and circular at the outlet. The bent duct of these complex shapes has not been investigated, but has been used in many fields. The performance of such bent duct is investigated under inlet speed 54 m/s and Re = 238,000. Wall static pressure tappings are located surface of the bent duct to measure the static pressure and a probe is traversed at the inlet and outlet of the bent duct to measure the total pressure. As a result, it presents static pressure distribution on the bent duct surface, streamwise velocity profile at inlet and outlet of the bent duct and total pressure loss profile at outlet. In this investigation, the total pressure loss coefficient is 0.243.

  • PDF

A Study on the reduction of cogging force of stationary discontinuous armature Permanent Magnet Linear Synchronous Motor by change in Auxiliary pole (보조극 변화에 따른 전기자 분산배치 영구자석형 리니어 동기 모터의 코깅력 저감에 관한 연구)

  • Lee, Kyu-Myung;Kim, Yong-Jae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.6
    • /
    • pp.613-619
    • /
    • 2010
  • The stationary discontinuous armatures that are used in permanent magnet linear synchronous motors (PM-LSMs) have been proposed as a driving source for transportation systems. However, the stationary discontinuous armature PM-LSM contains the outlet edges which always exist as a result of the discontinuous arrangement of the armature. For this reason, the outlet edge cogging force generated between the armature's core and the mover's permanent magnet. This paper contemplated the outlet cogging for ceaccording to 2-D numerical analysis by FEM. We installed the auxiliary pole for in order to minimize the outlet cogging force.

Effects of Shopping Orientation on Brand Loyalty and Shopping Satisfaction of Fashion Outlet Consumers (패션 아울렛 소비자의 쇼핑성향이 브랜드 충성도 및 쇼핑만족도에 미치는 영향)

  • Lee, A-Ram;Yoo, Tai-Soon
    • Journal of the Korean Society of Costume
    • /
    • v.60 no.2
    • /
    • pp.114-129
    • /
    • 2010
  • The purpose of this study were to identify shopping orientation for fashion outlet consumers and its significance in influencing brand loyalty and shopping satisfaction. This study will propose results which help to better understand shopping orientation of fashion outlet consumers. A questionnaire was administered to 326 20s male and female living in Daegu Gyeongbuk during October of 2008. Data were analyzed by using Factor analysis, Reliability analysis, t-test and Regression analysis. The results of the research are as follows: First, The shopping orientation could be into 5 dimensions: pleasure tendency, fashion tendency, name brand tendency, prudence buying tendency, economic tendency. Brand loyalty were factor analyzed resulting three factors such as brand loyalty, brand care and brand knowledge. Brand loyalty factors of brand loyalty and brand knowledge had a positive effect on fashion tendency, name brand tendency. Brand care has a positive effect on name brand tendency and economic tendency. Second, Shopping satisfaction were factor analyzed resulting five factors such as product, store atmosphere, service store reputation, location convenience and price. Outlet product had a positive effect on fashion tendency, name brand tendency, prudence buying tendency and while all other factors showed a positive effect on preferences to follow trends. However, outlet price had a positive effect on only those consumers possessing a economic tendency.

Numerical Analysis of Flow Phenomena in Cylindrical Shell with Baffle according to the Position of Inlet and Outlet (출.입구 위치에 따른 배플을 갖는 원통내 유동특성에 대한 수치해석)

  • Shin, Y.H.;Sayeed, S.M.;Jean, Y.C.;Chung, H.S.;Jeong, H.M.
    • Journal of Power System Engineering
    • /
    • v.15 no.6
    • /
    • pp.22-26
    • /
    • 2011
  • A numerical simulation on the flow field was carried out on the cylindrical shell with baffles. The steady incompressible 3-D Navier-Stokes solution is obtained with the actual operational condition and geometry of the heat exchanger. The effect of the location of inlet and outlet on the cylindrical shell with baffle is investigated by varying flow rate. The angle between the location of In/Outlet and baffle cutting part is $0^{\circ}$, $30^{\circ}$, $60^{\circ}$, $90^{\circ}$, $120^{\circ}$, $150^{\circ}$ and $180^{\circ}$. The present results show that the pressure drop is dependent on Reynolds number in the inlet area and position of inlet and outlet; i.e., the pressure drop increases with increasing Reynolds number and the pressure drop decreases with increasing angle between baffle cutting part and position of inlet and outlet.

Cause Diagnosis and Reduction Measures of Foaming in the Treated Wastewater Outlet of D Wastewater Treatment Plant (하수처리수 방류구의 거품발생 원인진단 및 저감방안: 국내 하수처리장 사례를 중심으로)

  • Shin, Jae-Ki;Cho, Youngsoo;Kim, Youngsung;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.49 no.2
    • /
    • pp.124-129
    • /
    • 2016
  • This study was conducted to suggest the cause analysis and mitigation measures of foaming generated in the effluent of wastewater treatment plant. The foam generated in the outlet connected with the tidal river system was identified as structural problems. And the main cause of foaming was air entrainment by an impinging jet and the internal accumulation by the diffusion barrier. In consideration of these conditions, it present the effective ways such as micro-screen and submerged outlet, to mitigate the foaming generated in the water channel and outlet end.

Implementation of Electricity Management System based on the Wireless ICT (무선 ICT기반의 전력관리시스템 구현)

  • Kim, Min-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.123-129
    • /
    • 2014
  • This paper suggests that it provides a electricity management system for wasting electricity, from power demand growth environments. This Energy management system based on ICT(Information & Communication Technology) can control Smart Power Outlet connecting to this system with Web Browser and Android phone, anytime, anywhere. Through analysis of acquisition data from them, this proposed system can monitor and control power consumption efficiently. This system was organized mesh network of Smart Power Outlet, gateway by wireless Zigbee, and ESS(Energy Saving System) by TCP/IP beyond existing limit of communication distance and space.