• Title/Summary/Keyword: Outlet

Search Result 2,616, Processing Time 0.029 seconds

Influence of Blade Outlet Angle and Blade Thickness on Performance and Internal Flow Conditions of Mini Centrifugal Pump

  • Shigemitsu, Toru;Fukutomi, Junichiro;Kaji, Kensuke
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.3
    • /
    • pp.317-323
    • /
    • 2011
  • Mini centrifugal pumps having a diameter smaller than 100mm are employed in many fields; automobile radiator pump, ventricular assist pump, cooling pump for electric devices and so on. Further, the needs for mini centrifugal pumps would become larger with the increase of the application of it for electrical machines. It is desirable that the mini centrifugal pump design be as simple as possible as precise manufacturing is required. But the design method for the mini centrifugal pump is not established because the internal flow condition for these small-sized fluid machines is not clarified and conventional theory is not suitable for small-sized pumps. Therefore, we started research on the mini centrifugal pump for the purpose of development of high performance mini centrifugal pumps with simple structure. Three types of rotors with different outlet angles are prepared for an experiment. The performance tests are conducted with these rotors in order to investigate the effect of the outlet angle on performance and internal flow condition of mini centrifugal pumps. In addition to that, the blade thickness is changed because blockage effect in the mini centrifugal pump becomes relatively larger than that of conventional pumps. On the other hand, a three dimensional steady numerical flow analysis is conducted with the commercial code (ANSYS-Fluent) to investigate the internal flow condition. It is clarified from the experimental results that head of the mini centrifugal pump increases according to the increase of the blade outlet angle and the decrease of the blade thickness. In the present paper, the performance of the mini centrifugal pump is shown and the internal flow condition is clarified with the results of the experiment and the numerical flow analysis. Furthermore, the effects of the blade outlet angle and the blade thickness on the performance are investigated and the internal flow of each type of rotor is clarified by the numerical analysis results.

Experimental Investigation on the Efficiency of Reducing Air Bubble Formation by Installing Horizontal Porous Plate in the Submerged Outlet Structure of Power Plant (발전소 수중방류구조 내 수평유공판 설치에 따른 거품발생 저감효과에 관한 실험적 연구)

  • Oh, Sang-Ho;Oh, Young-Min;Kang, Keum-Seok;Kim, Ji-Young
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.5
    • /
    • pp.472-481
    • /
    • 2008
  • In this study hydraulic experiment was carried out to investigate the flow characteristics in the submerged outlet structure of Boryeong power plant and the efficiency of bubble reduction by installing horizontal porous plate in the outlet structure. The cross-sectional mean velocity in the submerged outlet structure was smaller than 1 m/s, the target value at the design stage to prevent bubble outflow to the open sea area. In addition, it was found that the maximum depth of bubble penetration is reduced 30 to 50% by installing the horizontal porous plate at the second falling location in the submerged outlet structure. It is expected that the total bubble amount entrained in the water will be most efficiently reduced by installing square-hole-shape porous plate of 20 cm hole size and making its central section as non-porous structure to dissipate the energy of falling water.

Analysis of outlet edge cogging force at the Permanent Magnet Linear Synchronous Motor According to Difference of the Winding Method (권선방식 차이에 따른 영구자석 선형 동기 전동기의 단부 코깅력 해석)

  • Kim, Yong-Jae;Kim, Sung-Jin
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.6
    • /
    • pp.889-895
    • /
    • 2011
  • PMLSM is structurally simple and it have a lot of merits such high speed, high thrust force etc., but cogging force by slot-teeth structure of armature and cogging force by outlet edge effect occurs. This is the cause of thrust force ripple and generate the noise and vibration. Therefore, in this paper we proposed installation of an auxiliary pole to mover of the PMLSM in order to decrease cogging force by the outlet edge which came necessarily into being discontinuous arrangement of the armature. Also, outlet edge cogging force designed a form of the auxiliary pole which the minimum became, and we compared a outlet edge cogging force characteristic along a winding method of an armature as we used 2-D of finite element analysis.

A Study on Outlet Damage Prediction of Pipe Culverts in Forest Road (임도 횡단배수구의 유출구 피해 예측에 관한 연구)

  • Kim, Myung Hwan;Hwang, Jin Seong;Yu, Young Min;Cha, Du Song
    • Journal of Korean Society of Forest Science
    • /
    • v.107 no.3
    • /
    • pp.278-286
    • /
    • 2018
  • This study examined the damage characteristics through investigation for a total of 10 factors (longitudinal position, crossing position, soil type, collecting well volume, outlet position, water apron material, waterway existence, pipe culvert diameter, pipe culvert gradient, pipe culvert height) affecting outlet damages of forest road cross drainage for forest roads in the Research Forest of Kangwon National University. We predicted outlet damages of forest road cross drainage for forest roads using a discriminant analysis Results showed that longitudinal position, crossing position, soil type and pipe culvert height did not affect damages caused to forest road cross drainage. Most influential factors affecting outlet damages were outlet position, waterway existence, pipe culvert diameter, pipe culvert gradient and collecting well volume, respectively. The discriminant ratio calculated from the developed discriminant function was 68.8% which is reasonably reliable.

A Numerical Study of the 3-D Flow in the Primary Calcinator of Porcelain (도자기 1차 소성로의 3차원 유동장 수치해석에 관한 연구)

  • 김성수;홍성선;박지영;오창섭
    • Journal of Energy Engineering
    • /
    • v.5 no.1
    • /
    • pp.50-55
    • /
    • 1996
  • A numerical simulation on a primary calcinator of porcelain was performed with using Fluent to calculate the heat efficiency by studying velocity vector and temperature profile according to variables such as the location of outlet and porcelain. Control-Volume based Finite Difference Method and Up-wind scheme are used for discretization of differential equation. SIMPLEC Algorithm and standard k-$\varepsilon$ turbulent model are selected to resolve the pressure-velocity coupling and the turbulent. The result of simulation showed that the whole velocity vector field in a calcinator was varied greatly according to the location of outlet. But the whole temperature profile at each zone was still high regardless of the location of outlet because of the radiation. But the temperature of a case with a outlet at sidepart of preheating or cooling zone was little high compared to the case with a outlet on the top of preheating zone. The velocity vector field and temperature profile in a calcinator were almost not affected by the location of porcelain, but the temperature inside a porcelain was much affected according to the place where it was located. The heat efficiency in a calcinator was 44.6% and the gas temperature in the outlet was about 1000 K.

  • PDF

An Exploratory Study on the Development of Training Programs for Hotel Sommeliers (호텔 소믈리에 교육 프로그램 개발을 위한 탐색적 연구)

  • Choi, Young-Joon
    • Culinary science and hospitality research
    • /
    • v.15 no.4
    • /
    • pp.200-211
    • /
    • 2009
  • The objective of this study is to draw a guideline in developing a training program for sommeliers. To accomplish the objective, an exploratory study was conducted through field professionals and sommeliers between May and July in 2009 adopting the Dacum method. As a result, a sommelier is regarded as a professional who possesses vast knowledge in wine, food & beverage and outlet operation and offers assistance to a guest. Six distinctive areas of duties such as preparation of guest service, guest encounter service, outlet preparation, outlet management, wine purchasing and cellar management, self improvement were drawn in this study comprising 93 following tasks which explained job description of a sommelier. Guest service encompasses 13 tasks such as outlet maintenance and guest encounter service with 40 tasks such as encountering a guest. Outlet preparation contains 6 tasks such as outlet preparation while outlet management contains 13 tasks such as guest management. Wine purchasing and cellar management contains 6 tasks such as wine purchasing while self improvement contains 15 tasks such as understanding world's food and beverages. Outlet management was regarded as the most important and difficult area and wine purchasing and cellar management was regarded as the most frequent task from the study foundings.

  • PDF

The Outlet Temperature Prediction of In-Situ Thermal Response Test using CFD Analysis (CFD 해석을 이용한 현장 열응답 시험의 출구온도 예측)

  • Sim, Yong-Sub;Lee, Hee-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.28-35
    • /
    • 2016
  • The in-situ thermal response test for the design of a ground heat exchanger of geothermal heat pumps have difficulty in predicting the outlet temperature according to the variation of conditions due to the expense and time. This paper suggests a 3-D CFD analysis method to predict the heat transfer performance of vertical type ground heat exchanger, which is mostly used in national, and the outlet temperature and the slope of two in-situ thermal response tests were compared to test the proposed CFD reliability. The results of CFD analysis showed that the outlet temperature was predicted to within $0.5^{\circ}C$ of the actual value and the slope was predicted to within 1.6%. The reliability of the CFD analysis method was confirmed using this process, and the outlet temperature prediction of the two in-situ thermal response tests was obtained by changing ${\pm}20%$ of the flow rate and the effective thermal conductivity conditions, respectively. The results of CFD analysis showed that the outlet temperature of Case 1 was 28.0 (-20%) and $29.6^{\circ}C$ (+20%) for the flow rate variation and $29.6^{\circ}C$ (-20%) and $28.0^{\circ}C$ (+20%) for the effective thermal conductivity variation, and the outlet temperature of Case 2 was 28.4 (-20%) and $29.8^{\circ}C$ (+20%) for the flow rate variation and $29.7^{\circ}C$(-20%) and $28.4^{\circ}C$(+20%) for the effective thermal conductivity variation.

Simulation of East Sea Circulation in a Laboratory Experiment of Rotating Cylindrical Container (동해 해수순화 모의를 위한 회전반 실험)

  • 나정열;최진영
    • 한국해양학회지
    • /
    • v.30 no.1
    • /
    • pp.57-63
    • /
    • 1995
  • Two-layered fluid with sloping bottom and top(${\beta}$-effect) in rigid cylinder is put on the rotating table. To drive the lower-layer motion in "the Sverdrup type" flow external fluid is pumped into the lower-layer. By introducing inlet-outlet system in the upper-layer, an analogy to the Tsushima Tsugaru, Soya of the East Sea has been tested. The position of the inlet-outlet system and the difference between the strength of inlet or outlet flow are changed to see the effects of the wind stress on the upper-layer. The northern part of inflow toward the outlet may be interpreted roughly as the position of the polar front in the East Sea. Experimental observations have revealed that the inflow flows along the western boundary before it separates into the interior and flows straight toward the outlet position. However, the wind effect is imposed upon the upper-layer, the western boundary flow branches into two parts of which one flows along the boundary and the other flows into the interior under the influence of negative wind stress curl, while southward western boundary flow seems to block the flow and deflect it to the interior. The changes in the position of inlet-outlet system produce more significant changes in flow pattern in that cyclonic flow in the north controls the northern extent of the polar front by deflecting the northward interior motion toward the west(outlet). Interface displacement which depends strongly on the velocity difference between two layers seems to play crucial role in terms of the path of upper-layer flow, particularity, the inflow.

  • PDF

Hydraulic & Hydrologic Design Criteria for an Emergency Discharge of Reservoir (I) (댐 비상방류 설계기준 선정을 위한 수리수문학적 검토(I))

  • Son, Kwang Ik;Yi, Jaeeung
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.3
    • /
    • pp.149-158
    • /
    • 2015
  • It is well known that emergency outlet works have to be provided for the safety of dams. However, concept of emergency outlet works did not applied for the design of the most dams in Korea. Korean design standard for low-level outlet works does not provide enough design criteria which could be used in design of emergency outlet works. In this research, as-built status and hydraulic design criteria of outlet works, such as drawdown rate or hydraulic pressure due to the impounded water depth, were examined. Another relationship between drawdown rate and the dam slope stability was also examined with SEEP model. It was found that 25% reduction of impounded water depth decreases the pressure forces about 50%. Therefore, outlet works should be designed to drawdown properly at the beginning of the emergency. Seepage analysis of dam bodies showed that most of Korean dams could safely stand for 1m/day drawdown rate. Higher drawdown rate could result high discharge so the drawdown rate must be related with the flood risk of downstream. Finally, multi-stage design was recommended that faster discharge for the initial 25% of water depth in 7-10 days than the rest of it in 1-2 months.

Natural Circulation Flow Investigation in a Rectangular Channel (사각 단면 채널에서의 자연순환 유동에 관한 연구)

  • Ha, Kwang-Soon;Kim, Jae-Cheol;Park, Rae-Joon;Kim, Sang-Baik;Hong, Seong-Wan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3086-3091
    • /
    • 2007
  • When a molten corium is relocated in a lower head of a reactor vessel, the ERVC (External Reactor Vessel Cooling) system is actuated as coolant is supplied into a reactor cavity to remove a decay heat from the molten corium during a severe accident. To achieve this severe accident mitigation strategy, the two-phase natural circulation flow in the annular gap between the external reactor vessel and the insulation should be formed sufficiently by designing the coolant inlet/outlet area and gap size adequately on the insulation device. For this reason, one-dimensional natural circulation flow tests were conducted to estimate the natural circulation flow under the ERVC condition of APR1400. The experimental facility is one-dimensional and scaled-down as the half height and 1/238 rectangular channel area of the APR1400 reactor vessel. As the water inlet area increased, the natural circulation mass flow rate asymptotically increased, that is, it converged at a specific value. And the circulation mass flow rate also increased as the outlet area, injected air flow rate, and outlet height increased. But the circulation mass flow rate was not changed along with the external water level variation if the water level was higher than the outlet height.

  • PDF