• Title/Summary/Keyword: Outflow Area

Search Result 269, Processing Time 0.03 seconds

A Two-dimensional Hydraulic Analysis Considering the Influence of River Inflow and Harbor Gate in the Bay (Harbor Gate와 유입하천의 영향을 고려한 만내의 2차원 수리해석)

  • Lee, Jae Joon;Lee, Hoo Sang;Shim, Jae Sol;Yoon, Jong Ju
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.1
    • /
    • pp.45-55
    • /
    • 2015
  • In this study, when seawall or harbor gate is installed for coastal disaster prevention, a two-dimensional water analysis in the bay is carried out to consider the flood amount of river inflow and effect of harbor gate. The Yeongsan river and the port Mokpo area are selcected for the study region. Then, by analyzing the hydraulic characteristics of flood flow of the Yeongsan river, we analysed the compatibility of the results in the two-dimensional hydrodynamic model. A tw-odimensional water analysis were conducted for the four cases considering whether a harbor gate is installed or not, and whether the inland water boundary condition is considered or not, also with open sea boundary condition. The results of the two-dimensional water analysis shows that water level change near the port Mokpo area is mainly caused by the discharge of the estuary barrage of the Yeongsan river because the harbor gate was installed. In addition, it is revealed that the volume of reservoir created by the harbor gate and the estuary barrage is too much small compared to the volume of the discharge from the Yeongsan river. Therefore, when the harbor gate is installed in the open sea, we concluded that a flexible management between the harbor gate and the estuary barrage of the Yeongsan river is required. A initial water level of the bay and outflow from the harbor gate are proposed for disaster prevention in the coastal area of port Mokpo.

MODFLOW or FEFLOW: A Case Study of Groundwater Model Selection for the Upper Waikato Catchment, New Zealand

  • Weir, Julian;Moore, Dr Catherine;Hadfield, John
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.14-14
    • /
    • 2011
  • Groundwater in the Waikatoregion is a valuable resource for agriculture, water supply, forestry and industries. The 434,000 ha study area comprises the upper Waikato River catchment from the outflow of Lake Taupo (New Zealand's largest lake) through to Lake Karapiro (a man-made hydro lake with high recreational value) (Figure 1). Water quality in the area is naturally high. However, there are indications that this quality is deteriorating as a result of land use intensification and deforestation. Compounding this concern for decision makers is the lag time between land use changes and the realisation of effects on groundwater and surface water quality. It is expected that the effects of land use changes have not yet fully manifested, and additional intensification may take decadesto fully develop, further compounding the deterioration. Consequently, Environment Waikato (EW) have proposed a programme of work to develop a groundwater model to assist managing water quality and appropriate policy development within the catchment. One of the most important and critical decisions of any modelling exercise is the choice of the modelling platform to be used. It must not inhibit future decision making and scenario exploration and needs to allow as accurate representation of reality as feasible. With this in mind, EW requested that two modelling platforms, MODFLOW/MT3DMS and FEFLOW, be assessed for their ability to deliver the long-term modelling objectives for this project. The two platforms were compared alongside various selection criteria including complexity of model set-up and development, computational burden, ease and accuracy of representing surface water-groundwater interactions, precision in predictive scenarios and ease with which the model input and output files could be interrogated. This latter criteria is essential for the thorough assessment of predictive uncertainty with third-party software, such as PEST. This paper will focus on the attributes of each modelling platform and the comparison of the two approaches against the key criteria in the selection process. Primarily due to the ease of handling and developing input files and interrogating output files, MODFLOW/MT3DMS was selected as the preferred platform. Other advantages and disadvantages of the two modelling platforms were somewhat balanced. A preliminary regional groundwater numerical model of the study area was subsequently constructed. The model simulates steady state groundwater and surface water flows using MODFLOW and transient contaminant transport with MT3DMS, focussing on nitrate nitrogen (as a conservative solute). Geological information for this project was provided by GNS Science. Professional peer review was completed by Dr. Vince Bidwell (of Lincoln Environmental).

  • PDF

Estimation of the CY Area Required for Each Container Handling System in Mokpo New Port (목표 신항만의 터미널 운영시스템에 따른 CY 소요면적 산정에 관한 연구)

  • Keum, J.S.
    • Journal of Korean Port Research
    • /
    • v.12 no.1
    • /
    • pp.35-46
    • /
    • 1998
  • The CY can be said to function in various respect as a buffer zone between the maritime and overland inflow-outflow of container. The amount of storage area needed requires a very critical appraisal at pre-operational stage. A container terminal should be designed to handle and store containers in the most efficient and economic way possible. In order to achieve this aim it is necessary to figure out or forecast numbers and types of containers to be handled, CY area required, and internal handling systems to be adopted. This paper aims to calculate the CY area required for each container handling system in Mokpo New Port. The CY area required are directly dependent on the equipment being used and the storage demand. And also the CY area required depends on the dwell time. Furthermore, containers need to be segregated by destination, weight, class, FCL(full container load), LCL(less than container load), direction of travel, and sometimes by type and often by shipping line or service. Thus the full use of a storage area is not always possible as major unbalances and fluctuations in these flow occuring all the time. The calculating CY area must therefore be taken into account in terms of these operational factors. For solving such problem, all these factors have been applied to estimation of CY area in Mokpo New Port. The CY area required in Mokpo New Port was summarized in the conclusion section.

  • PDF

Research on improvement of water purification efficiency by porous concrete using bio-film (생물막을 이용한 다공성 콘크리트의 수질정화 효율 개선에 대한 연구)

  • Kim, Tae-Hoon;Li, Feng-Qi;Ahn, Tae-Woong;Choi, I-Song;Oh, Jong-Min
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.6
    • /
    • pp.815-821
    • /
    • 2011
  • This study aims to estimate the biological decomposition capacity of MPC(Microorganism Porous-Concrete). MPC has specific surface area formed by inside pores, and bio compound was added to those pores to reduce pollutants loading. To evaluate the water purification capacity of MPC, we carried out the comparative studies using different media types [GPC(General Porous-concrete), CPC(Compound porous-concrete), LPC(Lightweight aggregate porous-concrete)] under the condition of CFSTR, and different retention times (30, 60 and 120 min). We also estimated the purification capacity of MPC under different concentrations of pollutant loadings. The MPC showed higher efficiency in water purification function than other conventional porous concretes with efficient decrease rates of SS, BOD, COD, and nutrient concentrations. In the comparison experiment for different retention times, MPC showed the highest removal efficiency for all tested pollutants in the longest retention time(120 min). In the long period test, the removal efficiencies of MPC concrete were high until 100 days after the set up of the operation, but began to decrease. Outflow flux was invariable compared with inflow flux so that extra detention time for media fouling such as back washing is not needed. But the results suggested that appropriate management is necessary for long-term operation of MPC. As the final outcome, MPC using bio organisms is considered to be efficient for stream water purification when they used as substrates for artificial river structure.

Runoff Analysis Using the Discrete, Linear, Input-Output Model (선형 이산화 입력-출력 모형에 의한 유출해석)

  • Kwak, Ki Seok;Kang, In Shik;Jeong, Yeon Tae;Kang, Ju Bok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.859-866
    • /
    • 1994
  • It is difficult to make an exact estimate of the peak discharge or the runoff depth of flood and establish the proper measure for the flood protection since the water stage or discharge has been nearly measured at most medium or small river basins. The objective of this study is to estimate parameters of the discrete, linear, input-output model for medium or small river basin. The On-Cheon River basin in Pusan was selected for the study area. The runoff data used in the study has been observed since June 1993, and the effective rainfall was determined using the storage function method. The parameter sets of the discrete, linear, input-output model were estimated using the least squares method and the correlation function method, respectively. The calculated hydrographs by the discrete, linear, input-output model regenerated the observed outflow hydrographs well, and also the simulated flood hydrograph was comparable to the observed one. Therefore, it is believed that the discrete, linear, input-output model is simpler than other runoff analysis methods, and can be applied to a medium or small river basin.

  • PDF

Development of an Air Cushion Vest (공기주입형 쿠션 베스트 개발)

  • Son, Sue-Min;Choi, Hei-Sun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.2
    • /
    • pp.179-193
    • /
    • 2012
  • The development of modern transportation technology has required many people in spaces (such as vehicle seats, airports, and train stations) for long periods. The public seats provided in these places are manufactured in a standard size; however, fatigue sets in if the seats are unsuitable for the person's physical size. For this reason, this study developed an air cushion vest that would enhance the comfort of vehicle seats. Passengers in vehicles, trains, airplanes, and buses were observed and surveyed to understand the demand for seat comfort. Our analysis found that the greatest source of discomfort was involuntary nodding of the head while asleep and discomfort around the waist area. For this reason, the air cushion vest was designed to support the head and the waist. The neck cushion of this vest was designed to strengthen head support to counter forward nodding because existing commercial neck cushions had no support for forward nodding. For the waist cushion, at lumbar and below-lumbar parts were chosen as the key parts to be supported, the cushion was designed to contain air at those parts. To cover the embedded waist cushion, the vest was designed to be long. The closure was constructed with zippers from the neck to waistline, and with invisible snaps from the waistline to the hemline so that the wearer could open them easily while seated. A subjective comfort evaluation was conducted to verify the effectiveness of the developed vest. In the test, the developed cushions received a better evaluation than cushions currently available on the market. The volume of the vest could be adjusted by the inflow and outflow of air. It was proven that the vest was effective in terms of comfort and portability. This shows that the developed vest could enhance passenger comfort while sitting on vehicle seats.

Impact of the Geochemical Characteristics and Potential Contaminants Source of Surrounding Soil on Contamination of a Reservoir in an Island (II) - Appraisal of flow categorized by Incursion Using Rainfall-Runoff Model - (주변토양의 지구화학적 특성과 잠재적 오염원이 도서지역 저수지의 오염부하에 미치는 영향(II) - 강우 유출 모형을 이용한 유입경로별 유출량 평가 -)

  • Park, Sun-Hwan;Park, Wan-Sub;Jun, Young-Bong;Kim, Chang-Gyun;Kim, Sung-Gou;Kang, Seon-Hong;Chang, Yoon-Young;Jeong, Jeong-Ho;Jung, Jong-Ahm
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.3
    • /
    • pp.215-222
    • /
    • 2010
  • This research aims to gain the result of assessment of inflow categorized by runoff path using DIROM (Daily Irrigation Reservoir Operation Model) for Baengnyeong-myeon reservior which was built for residents of Baengnyeong island to solve the shortage of drinking water and stable supply of domestic water. The simulation results of DIROM and actual hydrograph of the reservoir show very low correlation with geological characteristics. The simulation results by DIROM after adjusting with modified Tank III model which considers all outflow from Tank II model as interflow among 3 level tanks show good correlation of its regional runoff and inflow characteristics with $R^2$=0.9058. In the study area, diffluence of 37% of rain fall of the study year has been simulated, which shows low result compared to the average river runoff of national water resource. In addition, 34.5% of total inflow to the study reservoir is mainly interflow and baseflow among expected several channels.

Experimental Investigation on the Efficiency of Reducing Air Bubble Formation by Installing Horizontal Porous Plate in the Submerged Outlet Structure of Power Plant (발전소 수중방류구조 내 수평유공판 설치에 따른 거품발생 저감효과에 관한 실험적 연구)

  • Oh, Sang-Ho;Oh, Young-Min;Kang, Keum-Seok;Kim, Ji-Young
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.5
    • /
    • pp.472-481
    • /
    • 2008
  • In this study hydraulic experiment was carried out to investigate the flow characteristics in the submerged outlet structure of Boryeong power plant and the efficiency of bubble reduction by installing horizontal porous plate in the outlet structure. The cross-sectional mean velocity in the submerged outlet structure was smaller than 1 m/s, the target value at the design stage to prevent bubble outflow to the open sea area. In addition, it was found that the maximum depth of bubble penetration is reduced 30 to 50% by installing the horizontal porous plate at the second falling location in the submerged outlet structure. It is expected that the total bubble amount entrained in the water will be most efficiently reduced by installing square-hole-shape porous plate of 20 cm hole size and making its central section as non-porous structure to dissipate the energy of falling water.

Comparison of Nitrogen Removal During Plant Growing Season with Non-Growing One in Free Water Surface Wetlands Purifying Stream Water (하천수를 정화하는 자유수면습지의 식물 성장기와 비성장기의 질소제거 비교)

  • Yang, Hong-Mo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.13 no.1
    • /
    • pp.82-92
    • /
    • 2010
  • Removal rates of NO3-N and TN in a free water surface wetland system during emergent plant growing season and non-growing were investigated. The system was established on floodplain in the down reach of the Gwangju Stream in 2008. Its dimensions were 46 meters in length and 5 meters in width. Typha angustifloria L. growing in pots about two years were planted on the half area of the system and Zizania latifolia Turcz on the other half. Water of the stream was funneled into it by gravity flow and its effluent was discharged back into it. Volumes and water quality of inflow and outflow were analyzed from October 2008 to September 2009. Inflow into the system averaged approximately 715 $m^3$/day and hydraulic residence time was about 1.5 hr. Average influent and effluent $NO_3$-N concentration was 3.37 and 2.74 mg/L, respectively and $NO_3$-N retention amounted to 18.7%. Influent and effluent TN concentration averaged 4.67 and 3.69 mg/L, respectively and TN abatement reached to 20.9%. $NO_3$-N removal rate (%) during plant growing season ($22.67{\pm}3.70$, mean ${\pm}$ standard error) was significantly high (p<0.001) when compared with that during plant non-growing one ($15.02{\pm}3.23$). TN abatement rate (%) during plant growing season ($27.42{\pm}5.98$) was also significantly high (p<0.001) when compared with that during plant non-growing one ($13.66{\pm}3.08$).

Selecting Target Sites for Non-point Source Pollution Management Using Analytic Hierarchy Process (계층분석적 의사결정기법을 이용한 비점원오염 관리지역의 선정)

  • Shin, Jung-Bum;Park, Seung-Woo;Kim, Hak-Kwan;Choi, Ra-Young
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.3
    • /
    • pp.79-88
    • /
    • 2007
  • This paper suggests a hierarchial method to select the target sites for the nonpoint source pollution management considering factors which reflect the interrelationships of significant outflow characteristics of nonpoint source pollution at given sites. The factors consist of land slope, delivery distance to the outlet, effective rainfall, impervious area ratio and soil loss. The weight of each factor was calculated by an analytic hierarchy process(AHP) algorithm and the resulting influencing index was defined from the sum of the product of each factor and its computed weight value. The higher index reflect the proposed target sites for nonpoint source pollution management. The proposed method was applied to the Baran HP#6 watershed, located southwest from Suwon city. The Agricultural Nonpoint Pollution Source(AGNPS) model was also applied to identify sites contributing significantly to the nonpoint source pollution loads from the watershed. The spatial correlation between the two results for sites was analyzed using Moran's I values. The I values were $0.38{\sim}0.45$ for total nitrogen(T-N), and $0.15{\sim}0.22$ for total phosphorus(T-P), respectively. The results showed that two independent estimates for sites within the test water-shed were highly correlated, and that the proposed hierarchial method may be applied to select the target sites for nonpoint source pollution management.