• Title/Summary/Keyword: Outfall system

Search Result 25, Processing Time 0.024 seconds

Condenser cooling system & effluent disposal system for steam-electric power plants: Improved techniques

  • Sankar, D.;Balachandar, M.;Anbuvanan, T.;Rajagopal, S.;Thankarathi, T.;Deepa, N.
    • Membrane and Water Treatment
    • /
    • v.8 no.4
    • /
    • pp.355-367
    • /
    • 2017
  • In India, the current operation of condenser cooling system & effluent disposal system in existing power plants aims to reduce drawal of seawater and to achieve Zero Liquid Discharge to meet the demands of statutory requirements, water scarcity and ecological system. Particularly in the Steam-Electric power plants, condenser cooling system adopts Once through cooling (OTC) system which requires more drawal of seawater and effluent disposal system adopts sea outfall system which discharges hot water into sea. This paper presents an overview of closed-loop technology for condenser cooling system and to achieve Zero Liquid Discharge plant in Steam-Electric power plants making it lesser drawal of seawater and complete elimination of hot water discharges into sea. The closed-loop technology for condenser cooling system reduces the drawal of seawater by 92% and Zero Liquid Discharge plant eliminates the hot water discharges into sea by 100%. Further, the proposed modification generates revenue out of selling potable water and ZLD free flowing solids at INR 81,97,20,000 per annum (considering INR 60/Cu.m, 330 days/year and 90% availability) and INR 23,760 per annum (considering INR 100/Ton, 330 days/year and 90% availability) respectively. This proposed modification costs INR 870,00,00,000 with payback period of less than 11 years. The conventional technology can be replaced with this proposed technique in the existing and upcoming power plants.

Development of Optimal Urban Runoff System : II. Development of Decision Making Model for Optimal Control of Rainfal1-Runoff System in Urban Area (최적 도시유출시스템의 개발 : II. 도시유역의 최적유출시스템 제어를 위한 의사결정모형의 개발)

  • Lee, Jung-Ho;Kim, Joong-Hoon;Kim, Hung-Soo;Jo, Deok-Jun;Kim, Eung-Seok
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.3
    • /
    • pp.207-217
    • /
    • 2004
  • Our government is interested in the rehabilitation for the old sewer rather than the construction of a new sewer system. However, the research work on the sewer rehabilitation is not sufficient as much as the interest on the rehabilitation is increased. There are some research works for the determination of rehabilitation time by the genetic algorithm in Korea and foreign countries. However, the previous studies have considered the simple elements for the determination of the rehabilitation time and so the complex decision-making according to the degree of sewer superannuation has not been performed. Therefore, in this study, we estimate the capacity and Ⅰ/Ⅰ of sewer and determine the priority of the optimal rehabilitation for each outfall within the draining system. Also we develop the optimal rehabilitation decision making system for the cost estimation of optimal rehabilitation using the genetic algorithm.

The Assessment on the Effect of Discharge and Variation of Water Quality from the Sewage Treatment Plants in Seoul (서울시 하수처리장 수질의 변동 및 방류수의 영향 평가)

  • Kwak Mi-Ae;Jung Jong-Heub;Eo Soo-Mi;Lee Hong-Keun
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.3 s.53
    • /
    • pp.1-12
    • /
    • 2004
  • This study was conducted to evaluate the variation characteristics of influent and effluent quality from sewage treatment facilities using activated sludge processes and to assess the impact caused by discharge of treated sewage on the receiving water Monthly data of five water quality items (BOD, COD, SS, T-N, T-P) were used to understand the water quality at three sewage treatment plants in Seoul for five years from 1999 to 2003. Concentration differences of water quality parameters were observed between upstream and downstream site at the sewage treatment plant outfall to investigate the impact of discharge in Tan stream and Han river basin. 1. Due to the effect of continuous improvement in sewer system, the concentrations of influent went on increasing generally. 2. Effluent concentrations of BOD, COD and SS showed the trend of a little decreasing, but the trend of increasing in T-N and T-P. 3. In Tan stream basin, the impact of sewage treatment plant discharge was not observed directly, because concentration of discharge was lower than stream water's. But discharges from sewage treatment plants affected water quality at downstream site in Han river, concentration of T-P especially.

Urban Nonpoint Source Pollution Assessment Using A Geographical Information System (GIS를 이용한 도심지 Nonpoint Source 오염 물질의 평가연구)

  • ;Stephen J. Ventura;Paul M. Harris;Peter G. Thum;Jeffrey Prey
    • Spatial Information Research
    • /
    • v.1 no.1
    • /
    • pp.39-53
    • /
    • 1993
  • A geographical information systems(GIS) was a useful aid in the assessment of urban nonpoint source pollution and the development of a pollution control strategy. The GIS was used for data integration and display, and to provide data for a nonpoint source model. An empirical nonpoint source loading model driven by land use was used to estimate pollutant loadings of priority pollutant. Pollutant loadings were estimated at fine spatial resolution and aggregated to storm sewer drainage basins(sewershedsl. Eleven sewersheds were generated from digital versions of sewer maps. The pollutant loadings of individual land use polygons, derived as the unit of analysis from street blocks, were aggregated to get total pollutant loading within each sewershed. Based on the model output, a critical sewershed was located. Pollutant loadings at major sewer junctions within the critical sewershed were estimated to develop a mi t igat ion strategy. Two approaches based on the installat ion of wet ponds were investigated -- a regional approach using one large wet pond at the major sewer outfall and a multi-site approach using a number of smaller sites for each major sewer junction. Cost analysis showed that the regional approach would be more cost effective, though it would provide less pollution control.

  • PDF

Changes of Tissue N Content and Community Structure of Macroalgae on Intertidal Rocky Shores in Tongyeong Area due to Sewage Discharge (통영 지역의 암반 조간대에서 배출수 유입으로 인한 해조 군집 구조와 엽체 내 질소 함량의 변화)

  • Kang, Yun-Hee;Park, Sang-Rul;Oak, Jung-Hyun;Lee, Jin-Ae;Chung, Ik-Kyo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.42 no.3
    • /
    • pp.276-283
    • /
    • 2009
  • Enrichment in nutrients coming from urban sewage outfalls can lead to eutrophication in coastal areas, which can also change the species composition and community structure of macro algal communities. We investigated the structure of the macro algal community within three rocky shores in order to assess any possible differences in their characteristics. Site 1 was located near Tongyeong city's sewage outfall, Site 2 was located near a public beach area, and Site 3 faced open channel of the Ocean. All three sites were located within the same stretch of the coast, where Site 2 was located between sites 1 and 3. We measured the nutrient concentration in water and the tissue nitrogen content in macro algae samples. Nutrients in the water column surrounding site 1 were high in ammonium ($30.2\pm1.8{\mu}M$), nitrate ($26.2{\pm}0.1{\mu}M$), and phosphate ($2.7{\pm}0.1{\mu}M$) content, and were characterized by low numbers of macroalgal species and species and a low species diversity index. In contrast, site 3 exhibited relatively low nutrient concentration levels and a high number of macroalgal species and a high species diversity index. Comparative analysis showed that the tissue nitrogen content of macroalgae were significantly (P<0.05) affected by the nutrient concentration in the water column. The tissue nitrogen content of green algae within site 1 was higher than the others sites. However, the tissue nitrogen content of brown algae was similar at all three sites. Thus, the tissue nitrogen content of macro algae and the macro algal community structure of intertidal rocky shores were dependent on location and the performance of macroalgal communities was dependent on water quality.