• Title/Summary/Keyword: Outfall

Search Result 68, Processing Time 0.025 seconds

Spatial and Temporal Variations of Foraminifers as an Indicator of marine Pollution

  • Shin, Im-Chul;Yi, Hi-Il
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • v.26 no.1
    • /
    • pp.59-73
    • /
    • 1998
  • Sediment samples from five stations at the Shihwa Lake sewage outfall, west cost of Korea, were collected to evaluate the effect of the outfall on benthic foraminifers. Heavy metal (Cu and Zn) polluted the eastern part of the Shihwa Lake, adjacent to the Shihwa-Banwol Industrial Complexes, shows barren or nearly barren of benthic foraminifers, and the lowest number of species both at the core top and downcore. Excepting for the barren zone, pyritized benthic foraminifers abundantly occur both at the surface and downcore sediments in the western part of the Shihwa Lake, suggesting that foraminiferal disease by anoxic bacteria. Recent intrusion of pollutants form the Shihwa-Banwol Industrial Complexes and adjacent six major streams severely polluted the Shihwa Lake as shown by the low abundance (number/10 g) of benthic foraminifers, low number of Ammonia beccarii, low species diversity, and absence of both Elphidium spp. and ostracodes at the surface sediments compared of both downcore. Except the barren zone, both pyritized and non-pyritized Ammonia beccarii occur dominantly in the surface sediments and downcore. Elphidium spp. (either pyritized or non-phyritized) do not occur in the surface sediments of whole stations. However, they occur from the entire downcore sediments except in the eastern part of Shihwa Lake. Arenaceous foraminifers do not inhabit in the heavily polluted areas as evidenced by the occurrence of relatively deep core depth (11-15 cm). Ostracodes occur at the downcore sediments, but they do not occur at the surface sediments. Ostracodes also do not occur at the heavily polluted areas in the eastern part of the Shihwa Lake both at the surface and downcore sediments, indicating that the abundance of ostracodes also can be used for a pollution indicator.

  • PDF

Control of the Sediment in a Combined Sewer Using a Separation Wall

  • Lim, Bong Su;Kwon, Chung Jin;Kim, Do Young;Lee, Kuang Chun
    • Environmental Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.71-75
    • /
    • 2013
  • This study is to evaluate the effects of the separation wall on the sediment quality and quantity in a combined sewer, by surveying the sewer overflow and sediments during a rainfall. Since the separation wall installed in the combined sewer separates the rainfall and the sewage, the flow rate of the sewage is increased, and the amount of the sediment deposited on the sewer is decreased. One sampling point was the outfall of Daesacheon with a separation wall, and the other was the outfall of Gwaryecheon without a separation wall, in Daejeon metropolitan city. The maximum control of the biochemical oxygen demand (BOD) overflow load was more than 38% in the Daesacheon point with the separation wall, during a rainfall of 0.11 mm/hr. The maximum control of the BOD overflow load was 24% in Gwaryecheon without a separation wall, during a rainfall of 1.0 mm/hr. According to the survey results of the sediment in the sewer, the discharged sediment deposited on the sewer in Gwaryecheon point was about 23% to 28% of the total suspended solid during the rainfall. In addition, the average velocity of sewage in the presence of sediment was about 0.30 m/s, and if the separation wall is installed, it was expected to be about 1.01 m/s, that is 3.4 times more than the same conditions, resulting in the reduction of the sediment deposit.

Multi-objective optimization of stormwater pipe networks and on-line stormwater treatment devices in an ultra-urban setting

  • Kim, Jin Hwi;Lee, Dong Hoon;Kang, Joo-Hyon
    • Membrane and Water Treatment
    • /
    • v.10 no.1
    • /
    • pp.75-82
    • /
    • 2019
  • In a highly urbanized area, land availability is limited for the installation of space consuming stormwater systems for best management practices (BMPs), leading to the consideration of underground stormwater treatment devices connected to the stormwater pipe system. The configuration of a stormwater pipe network determines the hydrological and pollutant transport characteristics of the stormwater discharged through the pipe network, and thus should be an important design consideration for effective management of stormwater quantity and quality. This article presents a multi-objective optimization approach for designing a stormwater pipe network with on-line stormwater treatment devices to achieve an optimal trade-off between the total installation cost and the annual removal efficiency of total suspended solids (TSS). The Non-dominated Sorted Genetic Algorithm-II (NSGA-II) was adapted to solve the multi-objective optimization problem. The study site used to demonstrate the developed approach was a commercial area that has an existing pipe network with eight outfalls into an adjacent stream in Yongin City, South Korea. The stormwater management model (SWMM) was calibrated based on the data obtained from a subcatchment within the study area and was further used to simulate the flow rates and TSS discharge rates through a given pipe network for the entire study area. In the simulation, an underground stormwater treatment device was assumed to be installed at each outfall and sized proportional to the average flow rate at the outfall. The total installation cost for the pipes and underground devices was estimated based on empirical formulas using the flow rates and TSS discharge rates simulated by the SWMM. In the demonstration example, the installation cost could be reduced by up to 9% while the annual TSS removal efficiency could be increased by 4% compared to the original pipe network configuration. The annual TSS removal efficiency was relatively insensitive to the total installation cost in the Pareto-optimal solutions of the pipe network design. The results suggested that the installation cost of the pipes and stormwater treatment devices can be substantially reduced without significantly compromising the pollutant removal efficiency when the pipe network is optimally designed.

Determination of the Depth of Sewers in Residental Complexes (주택단지내 하수관거의 매설심도 결정에 관한 연구)

  • Lim, Bong Su;Choi, Eui So;Yi, Yun Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.8 no.3
    • /
    • pp.41-50
    • /
    • 1994
  • The depth of sewers in residential complexes was determined to prevent the separated sewers from misconnection between storm sewer and sanitary sewer, and from the submersion of the basement by minimizing the phenomenon of backwater when it rains. In residential complexes, main causes of the submersion were the misconnection of sewers, rising of the backwater level at outfall in sewer system, poor maintenance of sewers, and lacking in their cross section. Minimum depth of sewers should be over 1.2~1.5m. According to the economic analysis, the depth of 1.5m~3.0m was appropriate for minimizing the submersion of basements and for making the disposal of domestic wastewater more easily.

  • PDF

Current and Long Wave Influenced Plume Rise and Initial Dilution Determination for Ocean Outfall (해양 배출구에서 해류와 장파에 의한 플룸 상승과 초기 희석도 결정)

  • Kwon, S.J.
    • Journal of Korean Port Research
    • /
    • v.11 no.2
    • /
    • pp.231-240
    • /
    • 1997
  • In the United States, a number of ocean outfalls discharge primary treated effluent into deep sea water and contribute for more efficient wastewater treatment. The long multiport diffuser connected by long pipe from a treatment plant discharge wastewater into deep water due to the steep slope of the sea bed. However, Plume discharged from the diffuser can have significant impacts on coastal communities and possibly immediate consequence on public health. Therefore, there have been growing interests about the dynamics of plume in the vicinity of the ocean outfalls. It is expected that the ocean outfall should be considered for more efficient and reliable wastewater treatments as soon as possible around coastal area in South Korea. A number of studies of plume ynamics have used various models to predict plume behavior. However, in many cases, the calculated values of plume behavior are in significantly poor agreement with realistic values. Therefore, in this study, it is recommended that improvements should be made in the application of the plume model to more simulate the actual discharge characteristics and ocean conditions. It should be noted that input parameters in plume models reflect realistic ocean conditions like waves as well as currents. In this study, as one of the new parameters, current and long wave-influenced plume rise and initial dilution have been taken into account by using simple linear wave theory under some specific assumptions for more reliable plume behavior description. Among the improved plume models approved by EPA (Environmental Protection Agency), the RSB(Roberts-Snyder-Baurngartner) and UM(Updated Merge) models were chosen for the calculation of plume behavior, and the variation calculated by both models on the basis of long period wave was compared in terms of plume rise and initial dilution.

  • PDF

NEAR-FIELD DILUTION OF ROSETTE TYPE MULTIPORT WASTEWATER DIFFUSERS

  • Seo, Il-Won;Yeo, Hong-Koo
    • Water Engineering Research
    • /
    • v.3 no.2
    • /
    • pp.93-111
    • /
    • 2002
  • In this paper, mixing characteristics and dilution of the merging buoyant discharges from array of multiple jets has been extensively studied in the hydraulic model experiments. New equations for dilution, which include the merging effects correctly, were derived. Experiments were constructed in a 20-m long, 4.9-m wide and 0.6-m deep flume, and the model diffuser was manufactured to indicate the typical characteristics of the existing ocean wastewater outfall in South Korea. Buoyant discharge from the diffuser was reproduced using heated water. Water temperature was measured using CC-Type thermocouple sensors, which were connected to a 40-channel data logger. Experimental results show that merging between ports in a particular riser is dependent upon the discharge densimetric Froude number, whereas merging between two ports which are facing each other at 90$\circ$ at the adjacent risers is dependent upon the discharge densimetric Froude number and distance from the port and port spacing. Centerline dilution increase with distance from the port outlet until two plumes has merged. However, after merging occurs, increase of the centerline dilution almost stops. Further distance from the position where merging occurs, centerline dilution increases again.

  • PDF

Initial Mixing Analysis of Ocean Outfalls Discharged into Density Stratified Flowing Ambients (밀도성층화된 흐름수역으로 방류되는 해양방류관의 초기확산해석)

  • Lee, Jae-Hyeong;Seo, Il-Won
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.2
    • /
    • pp.207-217
    • /
    • 2000
  • A numerical model is applied to analyze the mixing characteristics of an axisymmetric turbulent buoyant jet discharged into flowing stratified ambients. The numerical model is a Gaussian-vortex model which incorporates the effects of the vortex pair known as the representative characteristics of far-field in flowing ambients. Six ocean outfalls that have field data for the initial dilution at the water surface are selected for testing the applicability of the developed numerical model. The comparisons of the observed initial dilutions and the simulated ones show that the developed numerical model could be used for the analyses of the initial mixings induced by the sewage diffuser discharged into the ocean.

  • PDF

The Near-field Behavior of Effluent discharged from Confined Disposal Facility (제한투기시설에서 배출되는 여수의 근역거동)

  • 정대득;이중우
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2000.11a
    • /
    • pp.95-107
    • /
    • 2000
  • The primary purpose of dredging work is to maintain navigational readiness and to increase environmental amenity, so that the dredging project which is composed of excavating, removing, transporting, storing and disposing dredged material must be carefully managed to insure that dredging works are completed in a cost-effective and environmentally safe manner. The most important point in dumping operations is an estimating and reducing the impacts of discharges at the dumping area. One of the most effective method for the reduction of ecological impacts at dumping area is using the schematic process composed of the sophisticated plan, precise work and predicting/reducing the impacts based on the numerical model and field observation. In this study, the numerical model is used to predict the near-field spatial fate and begavior of effluent discharged from Confined Dumping Facility(CDF) located near coastal area. To to this purpose, reappearing of tidal current was preceded. The model is then applied to Mokpo harbor, where capital dredging and maintenance dredging are conducted simultaneously and the CDF is under construction;. In the series of model case study, we found that the near-field behavior of effluent discharged from CDF was governed by the receiving water condition, outfall geometry, characteristics of efflent and CDF operating conditions.

  • PDF

Far-field Transport of Effluent Plumes Discharged from Masan Sea Outfalls

  • Kim, Young-Do;Kang, See-Whan;Seo, Il-Won;Oh, Byung-Cheol
    • Ocean and Polar Research
    • /
    • v.22 no.2
    • /
    • pp.69-80
    • /
    • 2000
  • A 3-D particle tracking model with normalized characteristic equations has been developed to predict the variation of near-field mixing characteristics and the far-field transport of the effluent plumes discharged from sea outfalls. The model was applied to the case study on the Masan sea outfall plumes discharged through a submerged multiport-diffuser. Numerical simulations of the effluent transport for 15 days which cover neap and spring tidal cycles in Masan Bay were conducted using fall velocities of the solid wastes and the initial plume characteristics obtained from normalized near-field characteristic equations. The results showed that time variations in near-field minimum dilutions with tidal ambient flow conditions are about $45{\sim}49$. Most of the heavy particles in the effluent plumes were settled and deposited in the vicinity of the outfalls immediately, and the finer particles were transported eastwards 3 km away from the outfalls for 15 days. A similar depositional trend of contaminated sediment was also found during a recent field survey.

  • PDF

Distribution of Fecal Sterols, Nonylphenol, and Polycyclic Aromatic Hydrocarbons in Surface Water from Masan Bay, Korea

  • Choi, Min-Kyu;Park, Yeon-Su;Moon, Hyo-Bang;Yu, Jun;Choi, Hee-Gu
    • Fisheries and Aquatic Sciences
    • /
    • v.13 no.3
    • /
    • pp.236-243
    • /
    • 2010
  • Fecal sterols, nonylphenolic compounds (NPs), and polycyclic aromatic hydrocarbons (PAHs) were determined in surface water from Masan Bay and its adjacent rivers in February 2005. Concentrations of coporstanol (Cop), an indicator of fecal pollution, in surface water ranged from <10 to 13,853 ng/L, and concentrations of nonylphenol, the most toxic of the NPs, ranged from 10.2 to 481 ng/L, and concentrations of PAHs ranged from 8.61 to 223 ng/L. The concentrations of the compounds measured in this study were lower than or comparable to those at other locations in Korea and other countries. The contamination of Cop and PAHs in surface water was associated with the discharge from rivers passing through cities and/or industrial complexes. The NP contamination was associated with wastewater treatment plant (WWTP) effluents through outfalls as well as riverine discharge. Compared to ecotoxicological values, the concentrations of NPs from rivers, the mouths of rivers, and WWTP outfall areas exceeded guidelines, suggesting that hot spot areas may pose a potential risk to sensitive species.