• Title/Summary/Keyword: Outdoor tests

Search Result 193, Processing Time 0.034 seconds

PID Recovery Characteristics of Photovoltaic Modules in Various Environmental Conditions (다양한 환경조건에서 태양전지모듈의 PID회복특성)

  • Lee, Eun-Suk;Jung, Tea-Hee;Go, Seok-Hwan;Ju, Young-Chul;Chang, Hyo Sik;Kang, Gi-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.5
    • /
    • pp.57-65
    • /
    • 2015
  • The Potential Induced Degradation(PID) in PV module mainly affected by various performance conditions such as a potential difference between solar cell and frame, ambient temperature and relative humidity. The positive charges as sodium ions in front glass reach solar cell in module by a potential difference and are accumulated in the solar cell. The ions accelerate the recombination of generation electrons within solar cell under illumination, which reduces the entire output of module. Recently, it was generally known that PID generation is suppressed by controlling the thickness of SiNx AR coating layer on solar cell or using Sodium-free glass and high resistivity encapsulant. However, recovery effects for module with PID are required, because those methods permanently prevent generating PID of module. PID recovery method that voltage reversely applies between solar cell and frame contract to PID generation begins to receive attention. In this paper, PID recovery tests by using voltage under various outdoor conditions as humidity, temperature, voltage are conducted to effectively mitigate PID in module. We confirm that this recovery method perfectly eliminates PID of solar cell according to repeative PID generation and recovery as well as the applied voltage of three factors mainly affect PID recovery.

Development of Artificial Neural Network Model for Predicting the Optimal Setback Application of the Heating Systems (난방시스템 최적 셋백온도 적용시점 예측을 위한 인공신경망모델 개발)

  • Baik, Yong Kyu;Yoon, younju;Moon, Jin Woo
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.89-94
    • /
    • 2016
  • Purpose: This study aimed at developing an artificial neural network (ANN) model to predict the optimal start moment of the setback temperature during the normal occupied period of a building. Method: For achieving this objective, three major steps were conducted: the development of an initial ANN model, optimization of the initial model, and performance tests of the optimized model. The development and performance testing of the ANN model were conducted through numerical simulation methods using transient systems simulation (TRNSYS) and matrix laboratory (MATLAB) software. Result: The results analysis in the development and test processes revealed that the indoor temperature, outdoor temperature, and temperature difference from the setback temperature presented strong relationship with the optimal start moment of the setback temperature; thus, these variables were used as input neurons in the ANN model. The optimal values for the number of hidden layers, number of hidden neurons, learning rate, and moment were found to be 4, 9, 0.6, and 0.9, respectively, and these values were applied to the optimized ANN model. The optimized model proved its prediction accuracy with the very storing statistical correlation between the predicted values from the ANN model and the simulated values in the TRNSYS model. Thus, the optimized model showed its potential to be applied in the control algorithm.

Development of HVDC 500kV PPLP MI cable systems in Korea (HVDC 500kV PPLP MI 케이블시스템 개발)

  • Lee, Soo-bong;Cho, Dong-sik;Lee, Tae-ho;Kim, Sung-yun;Lee, Su-kil;Jeon, Seung-ik
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1202-1203
    • /
    • 2015
  • This paper describes the development of HVDC ${\pm}500kV$ polypropylene laminated paper (PPLP) mass-impregnated (MI) type cable system for HVDC transmission lines. As you know, mass-impregnated type cable generally has only insulating layer with the Kraft paper impregnated with a high-viscosity insulating compound. But polypropylene laminated paper is made of a layer of extruded polypropylene (PP) film sandwiched between two layers of Kraft paper. Thanks to PP film and its combination with Kraft paper, PPLP has higher AC, Impulse (Imp.) and DC breakdown (BD) strengths as well as lower dielectric loss than conventional Kraft paper insulation. In addition, Kraft MI cable has a limitation for the maximum conductor temperature as $55^{\circ}C$ But this PPLP MI cable has higher maximum conductor temperature than that of Kraft MI cable due to advantage of oil drainage characteristics. It is the most economic type of cable for HVDC transmission. Also HVDC ${\pm}500kV$ PPLP MI cable system was developed including land joints and outdoor-terminations. In order to prove the mechanical and electrical performances, the type test was carried out according to CIGRE recommendations. A full scale cable system has been tested successfully. And additional load cycle and polarity reversal tests on the cable system showed a higher performance compared with a similar mass impregnated paper cable.

  • PDF

Distributional Characteristics of Volatile Organic Compounds in the Indoor Air of Various Office Environments (다양한 사무실 실내환경에서의 휘발성유기화합물의 농도분포 특성)

  • Baek, Sung-Ok;Jeon, Chan-Gon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.5
    • /
    • pp.477-491
    • /
    • 2014
  • This study was carried out to evaluate the concentration variations of volatile organic compounds (VOCs) in the office environments located in a large urban area with respect to seasonality, smoking status, types of ventilation and heating. Indoor air sampling was undertaken in 37 and 30 offices in Daegu city during summer and winter, respectively. The VOC samples were collected using adsorbent tubes, and were determined by thermal desorption coupled with GC/MS analysis. The analytical method was validated for repeatability, method detection limits (MDL), and duplication precision. A total of 34 VOCs of environmental concern were determined, including 15 aromatics and 19 halogenated hydrocarbons. Average concentrations of BTEX appeared to 1.91 ppb, 22.98 ppb, 3.44 ppb, and 3.70 ppb, respectively. These values were relatively higher levels than those measured at homes and outdoor roadsides reported by other researches. In general, the concentrations of VOCs were higher in winter than summer, in smoking offices than non-smoking offices, in forced ventilation type than natural ventilation type, and in combustion heating than non-combustion heating offices. However, such differences were not always significant at a level of 0.05 by statistical tests (t-test and/or Mann-Whitney test) with some exceptions for BTEX and styrene. This study demonstrated that smoking status, ventilation type and presence of combustion sources indoors could be important factors on the elevated concentrations of some VOCs in the office environment.

Air Tightness Performance of Residential Timber Frame Buildings

  • Kim, Hyun-Bae;Park, Joo-Saeng;Hong, Jung-Pyo;Oh, Jung-Kwon;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.2
    • /
    • pp.89-100
    • /
    • 2014
  • Energy consumption statistics in 2005 from the Korea Energy Management Corporation show that building energy usage was about 24.2% of total domestic energy consumption, and 64% of total building energy usage was consumed by residential buildings. Thus, about 10% of total domestic energy consumption is due to the heating of residential buildings. Building energy can be calculated by the configuration of the building envelope and the rate of infiltration (the volume of the infiltration of outdoor air and the leakage of indoor air), and by doing so, the annual energy usage for heating and cooling. Therefore, air-tightness is an important factor in building energy conservation. This investigate air infiltration and various factors that decrease it in timber frame buildings and suggest ways to improve air-tightness for several structural types. Timber frame buildings can be classified into light frame, post and beam, and log house. Post and beam includes Han-ok (a Korean traditional building). Six light frame buildings, three post and beam buildings, one Korean traditional Han-ok and a log house were selected as specimens. Blower door tests were performed following ASTM E779-03. The light frame buildings showed the highest air-tightness, followed by post and beam structures, and last, log houses.

Cecocolic Intussusception Caused by Ancylostoma caninum Infection in a Dog

  • Ko, Hui-Yeon;Kim, Joonyoung;Geum, Migyeong;Suh, Guk-Hyun;Shin, SungShik;Kim, Ha-Jung
    • Journal of Veterinary Clinics
    • /
    • v.37 no.2
    • /
    • pp.106-108
    • /
    • 2020
  • An eight-month-old, outdoor, intact male English Pointer dog weighing 23.5 kg presented to the hospital with signs of hematochezia, soft stools, and weight-loss. There were no remarkable findings on physical examination, complete blood count, serum biochemistry, electrolyte and gas analysis, and radiography. The serologic and Polymerase Chain Reaction (PCR) tests for canine parvovirus were negative. A fecal smear examination showed rod-shaped, sporeforming bacteria. Additionally, a fecal flotation test showed ova of Ancylostoma spp. The size of ova was 60 × 40 ㎛, and it was identified as Ancylostoma caninum using light microscopy. The PCR test indicated a Clostridial perfringens infection and the presence of C. perfringens alpha toxin. The diagnosis given was C. perfringens enterotoxicosis with ancylostomiasis. Treatment included antibiotics (metronidazole, trimethoprim-sulfamethoxazole) and anthelmintics (afoxolaner, milbemycin oxime). After two weeks, the clostridial infection resolved, but ancylostomiasis persisted for six weeks. The anthelmintic was changed to Drontalâ plus (praziquantel/pyrantel pamoate/febantel). After four weeks, there were no remarkable findings in the fecal samples, but the patient still presented with watery stools and hematochezia. Survey of abdominal ultrasound had performed, and a target-like sign with multiple rings was seen in the cecocolic region. The patient was diagnosed with A. caninum-induced cecocolic intussusception from the history and clinical signs. After a surgery, he recovered fully. This is the first clinical case report of Ancylostoma caninum parasitizing from the small intestine and causing an intussusception in the large intestine.

Synthesis of Modified Silane Acrylic Resins and Their Physical Properties as Weather-Resistant Coatings (실란 변성아크릴수지의 합성과 고내후성 실리콘/아크릴수지 도료의 도막물성)

  • Park, Hong-Soo;Hong, Seok-Young;Kim, Song-Hyoung;Yoo, Gyu-Yeol;Ahn, Sung-Hwan;Hahm, Hyun-Sik;Kim, Seong-Kil
    • Journal of the Korean Applied Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.10-22
    • /
    • 2007
  • To prepare weather-resistant silicone/acrylic resin coatings for an architectural purpose, tetrapolymers were synthesized by a radical polymerization. 3-Methacryloxypropyltrimethoxysilane (MPTS) as a silicone monomer and n-butyl acrylate, methyl methacrylate, and n-butyl methacrylate as acrylic monomers were used. The compositions of monomers were adjusted to fix the glass transition temperature of acrylic polymer for $20^{\circ}C$. The composition of MPTS in the synthesized polymer were varied from 10 wt% to 30 wt%. On the basis of synthesized resin amber paints were prepared and their physical properties and effects for weatherability were examined. The presence of MPTS in silicone/acrylic resins generally resulted in low molecular weight and broad molecular weight distribution, and also lowered the viscosity of the copolymers. The coated films prepared from these resins showed good and balanced properties in general. Adhesion to the substrate was outstanding in particular. Weatherability tests were carried out in three different types such as outdoor exposure, QUV, and SWO. The test results showed that the silicone/acrylic resins containing 30 wt% of MPTS had weather-resistant properties.

Measurement and Comparison of Wi-Fi and Super Wi-Fi Indoor Propagation Characteristics in a Multi-Floored Building

  • Hwang, Gyumin;Shin, Kyubo;Park, Sanghyeok;Kim, Hyoil
    • Journal of Communications and Networks
    • /
    • v.18 no.3
    • /
    • pp.476-483
    • /
    • 2016
  • Super Wi-Fi is a Wi-Fi-like service exploiting TV white space (WS) which is expected to achieve larger coverage than today's Wi-Fi thanks to its superior propagation characteristics. Super Wi-Fi has been materialized as an international standard, IEEE 802.11af, targeting indoor and outdoor applications, and is undergoing worldwide field tests. This paper demonstrates the true potential of indoor Super Wi-Fi, by experimentally comparing the signal propagation characteristics of Super Wi-Fi and Wi-Fi in the same indoor environment. Specifically, we measured the wall and floor attenuation factors and the path-loss distribution at 770MHz, 2.401 GHz, and 5.540 GHz, and predicted the downlink capacity of Wi-Fi and Super Wi-Fi. The experimental results have revealed that TVWS signals can penetrate up to two floors above and below, whereas Wi-Fi signals experience significant path loss even through a single floor. It has been also shown that Super Wi-Fi mitigates shaded regions of Wi-Fi by providing almost-homogeneous data rates within its coverage, performs comparable to Wi-Fi utilizing less bandwidth, and always achieves better spectral efficiency than Wi-Fi. The observed phenomena imply that Super Wi-Fi is suitable for indoor applications and has the potential of extending horizontal and vertical coverage of today's Wi-Fi.

Absolute Altitude Determination for 3-D Indoor and Outdoor Positioning Using Reference Station (기준국을 이용한 실내·외 절대 고도 산출 및 3D 항법)

  • Choi, Jong-Joon;Choi, Hyun-Young;Do, Seoung-Bok;Kim, Hyun-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.1
    • /
    • pp.165-170
    • /
    • 2015
  • The topic of this paper is the advanced absolute altitude determination for 3-D positioning using barometric altimeter and the reference station. Barometric altimeter does not provide absolute altitude because atmosphere pressure always varies over the time and geographical location. Also, since Global Navigation Satellites system such as GPS, GLONASS has geometric error, the altitude information is not available. It is the reason why we suggested the new method to improve the altitude accuracy. This paper shows 3-D positioning algorithm using absolute altitude determination method and evaluates the algorithm by real field tests. We used an accurate altitude from RTK system in Seoul as a reference data and acquired the differential value of pressure data between a reference station and a mobile station equipped in low cost barometric altimeter. In addition, the performance and advantage of the proposed method was evaluated by 3-D experiment analysis of PNS and CNS. We expect that the proposed method can expand 2-D positioning system 3-D position determination system simply and this 3-D position determination technique can be very useful for the workers in the field of fire-fighting and construction.

Performance Characteristics of the Electrical Air Conditioning System for the Zero Emission Passenger Vehicle (무공해 승용 자동차의 냉방을 위한 전동식 냉방시스템 성능에 관한 연구)

  • Lee, Moo-Yeon;Cho, Chung-Won;Lee, Ho-Seong;Won, Jong-Phil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5430-5437
    • /
    • 2011
  • The objective of this study is to investigate the cooling performances of the electrical air-conditioning system using electric driven scroll compressor for zero emission passenger vehicles. This air conditioner with air source was used R-134a as a refrigerant and installed in a real zero emission passenger vehicle for tests under various driving conditions. The cooling performance of the electrical air conditioner was affected by driving velocities and conditions of the tested vehicle. The condensing rate of the condenser during driving is better than that of the idle condition. The average cool down temperature in the cabin room decreased on average $5.2^{\circ}C$ with the increase of the outdoor temperature from $20.0^{\circ}C$ to $30.0^{\circ}C$. In addition, the cooling performances were sufficient for cooling loads of the tested passenger car under tested conditions.