• Title/Summary/Keyword: Outdoor experiments

Search Result 266, Processing Time 0.029 seconds

Geometrical Building Analysis for Outdoor Environment Understanding of Autonomous Navigation Robot (자율주행 로봇의 외부환경 이해를 위한 기하학적인 빌딩 분석)

  • Kim, Dae-Nyeon;Trinh, Hoang-Hon;Jo, Kang-Hyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.3
    • /
    • pp.277-285
    • /
    • 2010
  • This paper describes an approach to analyze geometrical information of building images for understanding outdoor environment of autonomous navigation robot. Line segments and color information are used to classily a building with the other objects such as sky, trees, and roads. The line segments and their two neighboring regions are extracted from detected edges in image. The model of line segment (MLS) consists of color information of neighbor regions. This model rules out the line segments of non-building face. A building face converges into dominant vanishing points (DVPs) which include one vertical point and one of five horizontal points in maximum. The intersection of vertical and horizontal lines creates a facet of building. The geometrical characteristics such as the center coordinates, area, aspect ratio and aligned coexistence are used for extracting the windows in the building facet. In experiments, 150 building faces and 1607 windows were detected from the database of outdoor environment. We found that this result shows 94.46% detection rate. These experimental images were all taken in Ulsan metropolitan city in Korea under difference of viewpoints, daytime, camera system and weather condition.

Analysis on the performance characteristics of a variable-speed, roller-type vane compressor operating at low evaporating temperature (낮은 증발온도에서 운전되는 가변속 롤러형 베인 압축기의 성능특성에 관한 분석)

  • 김봉훈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.193-204
    • /
    • 1999
  • Performance of a variable-speed, roller-type vane compressor was evaluated at low evaporating temperature. First, an experimental investigation was conducted to examine the performance variation as functions of both outdoor temperature and rotating speed. For this purpose, a typical heat pump was implemented as a test apparatus to measure mass flow rate and power input. Secondly, computational investigations corresponding to the heat pump test conditions were performed to predict compressor performance using ORNL Map-Based compressor model. Results obtained from the heat-pump experiments showed that both mass flow rate and power consumption were sensitively dependent on both evaporating temperature and compressor speed as was predicted from the computational results. From the comparisons of both experimental and computational results, it was well recognized that the ORNL model was subjected to larger error in the accuracy of prediction as outdoor temperature decreased. When the outdoor temperature was above $-5^{\cire}C$, errors of predicted values corresponding to both mass flow rate and power consumption were estimated as $\pm$10% and $\pm$ 15%, respectively. Finally, it is suggested that the ORNL model needs to be re-evaluated if compressor map data tested below $-5^{\cire}C$(in evaporating temperature) are available.

  • PDF

Development of a Pet Robot Chasing a Moving Person in Outdoor Environment

  • Ahn, Cheol-Ki;Lee, Min-Cheol;Aoshima, Nobuharu
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.6 no.4
    • /
    • pp.67-72
    • /
    • 2005
  • In a park or street, we can see many people jogging or walking with their dogs that are chasing their masters. In this study, a pet robot that imitates dog's behavior is developed. The task of robot is to chase a person who is recognized as the master. The physical structure and the sensor system are designed for the task and environment. A three-wheel type locomotion system is designed as the robot's physical structure which can follow a person who is jogging in outdoor environment like a park. A sensor system, which can detect relative position of the master to the robot in highly dynamic and hazardous worlds, is developed. This sensor system consists of a signal transmitter which is held by the master and ultrasonic sensor array which are mounted on the robot. The transmitter emits RF (radio frequency) and ultrasonic signals simultaneously. The ultrasonic sensor array detects the signals and calculates direction and distance between the robot and the transmitter. The developed RF-ultrasonic sensor is evaluated through experiments. A purely reactive behavior-based control architecture is used for the robot. The behavior control performance of the robot is assessed in outdoor and indoor tests.

Variations in the Thermal Performance of R22 and R410A Refrigeration Systems Depending on Operation Conditions

  • Jeong, Ji-Hwan;Kweon, Young-Chel;Chang, Keun-Sun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.1
    • /
    • pp.10-20
    • /
    • 2004
  • Experiments have been conducted in order to make comparisons of characteristics of a R410a cycle with a R22 cycle in terms of cooling capacity and coefficient of performance (COP). The parameters examined in the present work include air flow rate, indoor and outdoor air temperatures, and indoor relative humidity. These two refrigeration cycles constructed for this study share all components except compressor, accumulator, oil separator, and piping. The measurements were made using a psychrometric calorimeter. The experimental results show that the R410A cycle has several advantages for indoor units while the R22 cycle yields better performance for outdoor units.

Study on the relief design for the fault current of polymer arrester (폴리머 피뢰기의 고장전류에 대한 방압 설계기술에 관한 연구)

  • Kim, In-Sung;Park, Hoy-Yul;Cho, Han-Goo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1717-1719
    • /
    • 1999
  • The chief advantage of polymer arrester. from design of pressure relief, anti-contamination, electrical failure was reduced by outdoor polymer housing. In the first for development of pressure relief design for polymer arrester, fault current and surge were studied through experiments of electrical. Designed the FRP inner tube and unit modules for pressure relief housing. Tested the performance of unit modules for pressure relief of polymer arrester, and the result was successful. The pressure relief of polymer arrester depend on design pattern of diamond shape and ellipse. Study on the pressure relief of FRP inner tube for outdoor polymer arrester. Designed and manufactured FRP inner tube of polymer arrester. Tested the fault current of polymer arrester per 10 kA, 10 cycle.

  • PDF

Implementation of a Smart Antenna System for Wide-Band CDMA WLL Channel (광대역 CDMA WLL용 스마트 안테나 시스템 구현)

  • 김미경;황현구;김종헌;박환석;김상태;최승원
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.6
    • /
    • pp.912-918
    • /
    • 2001
  • This paper presents a performance analysis of experimental observations of a uplink smart antenna system operating in a wide-band CDMA environment designed for a WLL (Wireless Local Loop) system. The numerical results shown in this paper have been obtained from practical experiments using commercially developed mobile terminals. The beam pattern provided by the weight vector and the resultant BER (Bit Error Rate) are observed in both indoor and outdoor signal environments. From the experimental observations, it is concluded that the proposed smart antenna system provides significant improvements in receiving both indoor and outdoor signal environments.

  • PDF

The effect on Electrical Characteristics according to the Pollution of the Field Exposed PV Modules (Field Exposed PV모듈 표면 오염이 전기적 특성에 미치는 영향)

  • Choi, Juho-Ho;Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong;Kim, Il-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1322-1323
    • /
    • 2011
  • This study is to analysis on electrical characteristics according to the pollution of the outdoor exposed modules. Output of module is generated locally because there are various factors of pollution on the front glass of the modules. The experiments is carried out by measuring out output of the module with MP-160 and hot spots with a IR camera. This study is to analysis on electrical characteristics according to the pollution of the outdoor exposed modules.

  • PDF

Noise & Vibration Evaluation and Analysis for Propeller Fan System of Air Conditioner Outdoor Unit (에어컨 실외기 프로펠러 홴계의 진동소음 평가 및 해석)

  • Park, Deug-Yong;Mo, Jin-Yong;Lee, Jin-Kyo;Koo, Hyoung-Mo;Choi, Weon-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1405-1409
    • /
    • 2000
  • The electro-magnetic noise generated from fan-driving motor is one of important items in view of abnormal noise which affect the quality of air conditioner noise. The electro-magnetic noise of the outdoor unit is identified by the serial experiments for related parts, whose effects are verified to give proper measures for reduced noise level. The weight of fan appears to be the most important factor, and the stiffness of the frame, such as motor bracket is shown to be important also.

  • PDF

Analysis on Performance of Axial Flow Fan for Outdoor Unit of Air-conditioner: Noise Characteristics (에어컨 실외기용 축류홴의 성능에 관한 연구: 소음 특성)

  • Kim, Yong-Hwan;Lee, Jang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.5
    • /
    • pp.29-34
    • /
    • 2010
  • In this paper, aerodynamic noise of axial flow fans for outdoor unit of air-conditioner was analyzed by both experiment and numerical simulation. The three-dimensional incompressible turbulent flow was predicted by the commercial computational fluid dynamics code SC/Tetra, while the aeroacoustic noise of an axial flow fan was predicted by FlowNoise. Computations and experiments were performed with two types of axial flow fans, in which very different noise source distributions were presented. The results obtained from this study are expected to show the way to reduce the noise of axial flow fans in industrial applications.

An Evaluation on Energy Recovery Performance of the Ventilation System in Multi-Residential Building by Field Measurement (실험을 통한 공동주택 환기시스템의 실제 운전 시 전열교환성능 검토)

  • Choi, Younhee;Song, Doosam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.68-73
    • /
    • 2017
  • Recently, energy recovery ventilators (ERVs) have been installed for energy saving in many multi-residential buildings in Korea. The performance of the heat exchanger of an ERV is analyzed in this study under specific indoor and outdoor conditions in a test-cell measurement. However, the performance of the heat exchanger varies according to the indoor and outdoor condition. In this study, the performance of energy recovery of the ventilation system was therefore analyzed in actual weather conditions using field measurement. Experiments were conducted under winter conditions in a multi-residential building for 20 days. Based on the measurement results, the characteristics of sensible heat and latent heat exchange rates were analyzed.