Analysis of the lightning characteristics by the Lightning DB in KOREA (낙뢰위치표정시스템의 낙뢰 DB를 이용한 한반도 뇌격 특이특성 분석)

  • Woo, J.W.;Kwak, J.S.;Shim, E.B.;Lee, G.W.;Kim, K.W.;Kim, B.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1658-1660
    • /
    • 2001
  • Because the overhead transmission lines are exposed to the outdoor weather, the faults of the transmission lines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the statistical distribution of lightning current parameters and the IKL map.

  • PDF

A Study on the Development of Lightweight Wall for Sound Transmission Loss and Field Test Results of the Dry-Wall System (차음성능이 향상된 경량벽체 개발 및 성능평가 연구)

  • 이병권;배상환;홍천화
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.699-704
    • /
    • 2004
  • As being inconvenient to apply reinforced concrete structure to high-rise buildings, it is applied steel structured system. Therefore light-weight wall systems are applied as partition wall to reduce the self-load of the building. But, the required performances of a light-weight wall are not evaluated systematically. As a field survey result, partition walls of house-to-house were not showed their respected performances, so the dwellers are feel so worse the quality of the whole building. In steel-structured high-rise buildings especially, occupant's dissatisfaction concerned indoor noise was high because curtain wall systems having a high air-tight performance isolate the outdoor noise making masking effect. Therefore wall systems which have high performances of sound insulation and air-tightness are required in high-rise buildings. As a result, a new drywall system was presented and the performance was verified with field test.

  • PDF

The Analysis of Characteristics of Silicone Rubber in Insulating Oil (절연유에 의한 Silicone Rubber의 특성 변화 분석)

  • Kim, H.J.;Kim, H.J.;Lee, C.M.;Han, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1216-1217
    • /
    • 2008
  • A description is given of impregnated silicone rubber used in accessories for application on outdoor termination (EB-A). We examines the effects of swelling and mechanical/electrical characteristics for impregnated silicone rubber to develop slip on type sleeve of silicone material. There are semi-conductive silicone rubber and insulation silicone rubber. This examination is monitored as a function of the viscosity and temperature of oil during 30hr. We measure elongation at breakdown and AC breakdown strength and volume resistivities of the oil-impregnated silicone rubbers. The measured values are compared to initial value as function of stress relief cone.

  • PDF

The Change of Electrical Properties on Silicone Rubber Contained ATH under Cyclic Aging(I) (ATH를 첨가한 실리콘고무의 반복열화에 따른 전기적 특성변화(I))

  • Oh, Tae-Seung;Lee, Chung;Kim, Ki-Yup;Park, Soo-Gil;Ryu, Boo-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.258-261
    • /
    • 2001
  • In this paper, aging characteristics of silicone rubber used for outdoor insulation have been investigated with regards to salt fog condition and heat aging effect. We look over the change of properties of silicone rubber in salt fog chamber with average leakage current monitoring for observing the transformation of surface degradation properties of silicone rubber with different ATH(alumina trihydrate, $Al_2O_3{\cdot}3H_2O$) filler contents. Surface resistivity, SEM(Scanning Electro Microscope) were measured.

  • PDF

Thermal Environment Analysis by the Diffusion Direction with Ceiling Type Air Conditioner of the Classroom (학교 교실의 천장형 에어컨 토출각도에 따른 온열환경 해석)

  • AHN, Chul-Lin;KIM, Dong-Gyue;KUM, Jong-Soo;PARK, Hee-Ouk;CHUNG, Yong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.17 no.2
    • /
    • pp.145-154
    • /
    • 2005
  • It is necessary to develop new air-conditioning method which can be satisfied individual separated space and request of occupants. The indoor thermal environment and flow field are investigated both experimentally and numerically. This study concentrated on analysis of indoor thermal environment by diffusion direction of ceiling type air conditioner of the classroom. The velocity and temperature distribution of air in the room calculated by 3-dimensional method, which include the effect of insulation of the building and outdoor state. This analysis shows that optimum diffusion direction is $30^{\circ}$ to increase thermal comfort in winter and optimum diffusion direction is $15^{\circ}$ to increase thermal comfort in summer.

Development of Real Time Analysis System about Lightning Information (낙뢰정보 실신간 통계분석시스템 개발)

  • Kwak, J.S.;Woo, J.W.;Shim, E.B.;Kim, K.W.;Kim, Y.S.;Lee, S.J.;Lee, G.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.169-171
    • /
    • 2003
  • Because the overhead transmission lines are exposed to the outdoor weather, the faults of the transmission tines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the development of real time analysis system about lightning information.

  • PDF

Development of Heal Time Lightning Information System (실시간 낙뢰화면 표시프로그램 개발)

  • Kwak, J.S.;Woo, J.W.;Shim, E.B.;Kim, K.W.;Kim, Y.S.;Lee, S.J.;Lee, G.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.175-177
    • /
    • 2003
  • Because the overhead transmission lines arc exposed to the outdoor weather, the faults of the transmission lines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the development of real time analysis system about lightning information.

  • PDF

Analysis of the lightning characteristics by LPATS Data during 7 year (LPATS에 의한 7년간의 한반도 뇌격특성분석)

  • Woo, J.W.;Shim, E.B.;Kwak, J.S.;Kweon, D.J.;Moon, J.D.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.509-511
    • /
    • 2003
  • Because the overhead transmission lines are exposed to the outdoor weather, the faults of the transmission lines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the statistical distribution of lightning current parameters and the IKL map.

  • PDF

The Diagnosis of Polymeric Insulation Materials for Outdoor in the Salt Fog (Salt fog 내에서 옥외용 고분자 절연물의 절연진단)

  • Moon, J.S.;Kim, J.H.;Lee, J.H.;Song, W.C.;Cho, H.G.;Yoo, Y.S.;Park, Y.G.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1569-1571
    • /
    • 2000
  • The ageing process was checked by leakage current monitoring in Salt Fog Method. In order to monitor leakage current, DAS with 12-bit, 8-channel A/D converter was prepared. The monitored components of leakage current were averages of the rms and peak, max peak, cumulative charge, and the cumulative number of peak pulses. The acquired data were stored to the disc periodically. And, surface conductivity was measured to investigate loss of hydrophobicity. The results suggest that surface conductivity and leakage current are well corresponding to initial loss of hydrophobicity.

  • PDF

Automatic Measuring Apparatus for Salt and Dust Contamination (염진해 오손도 자동측정장치)

  • 최남호;구경완;이명섭;한상옥;정재기;조성배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.187-190
    • /
    • 1999
  • To reduce the maintenance expence, and the possibility of electric outage and accident, accurate measurement should be carried. But the classical method has some problems in the aspect of man power, reliability, and expence. In this paper, we propose a new type apparatus, which could detect the degree of contamination on insulators on outdoor insulation system, such as transmission and distribution line insulator and bushing. The new type apparatus consists of Pelltier module, electrode system, and measuring part. At first leakage current detecting method was considered, then with the fault(oxidation of electrode) of that method we should propose a another method. We carried various test to prove the possiblity and reliability of the propoused apparatus. And we get some useful result with laboratory test.

  • PDF