• Title/Summary/Keyword: Out-Diameter

Search Result 2,870, Processing Time 0.031 seconds

Effects of Rolling Numbers and Feeds on Surface Deformation in Surface Rolling of Cast Iron (주철의 표면로울링에서 이송량과 로울링 회수에 따른 변화 연구)

  • Yuck, Kweng-Su;Lee, Yong-Chul;Kwak, Soo-Heon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.6 no.3
    • /
    • pp.68-77
    • /
    • 1989
  • The surface rolling for cylindrical surface of a grey cast iron was carried out using a lathe with a simple newly-designed tool system. A surface rolling tool used was steel ball whose diameter was 3/8 inch (9.525mm) The effects of rolling feeds and number of rolling on surface rolling were investigated. The contact pressure between ball and workpiece which was considered as Hertz's contact problem was examined and the track of motion of a ball on the cylindrical surface of a work- piece was measured according to the rolling feed. The results obtained were as follows; 1. The roughness of the machined surface which was originally 5.3 .approx. 28 umRz decreased to 1.2 .approx. 5 umRz according to rolling feeds and numbers of rolling. 2. The hardness increased from Hv 260 to Hv 290 .approx. 310 through 2 .approx. 4 rollings according to the roughness of machined surfaces. 3. The reduction of diameter was found to be proportional to the variations of roughness of previous machined surfaces. About 60% to 90% of reduction in diameter was made during the first rolling process. 4. An equation relating the reduction of diameter and the variation of surface roughness after surface rolling was presented using a geometric surface model. 5. An equation for the calculation of dynamic contact area between pressure ball and workpiece according to the rolling feed was presented.

  • PDF

A Study on the Helically Coiled Heat Exchanger of Small Diameter Tubes (극세관 헬리컬 코일형 열교환기에 관한 연구)

  • Kim, Ju-Won;Kim, Jeong-Hun;Kim, Jong-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1492-1499
    • /
    • 2001
  • In order to develop the compact and flexible heat exchangers, we made the helically coiled heat exchangers. They can be manufactured with small diameter copper tubes without the need for fins; inner diameter=1.0 mm, straight tube length=1.5 m. The experiments were carried out with the following conditions; evaporation pressure=0.6 MPa, air velocity=0.7 ∼ 1.7 m/s, and working fluid=R-22. Pressure drop and heat transfer coefficient of heat exchangers were experimented according to the air velocity. The results of heat transfer coefficient show a 35% beneficial increase fur these heat exchangers over the other covered fin-tube heat exchangers. A cooling capacity of about 3 kW was obtained with an air velocity of 1.5 m/s. The distribution header has also been designed fur efficient distribution of refrigerant flow.

Flow Visualization Study on the Turbulent Mixing of Two Fluid Streams (III) (분지관 혼합기의 난류혼합에 대한 유동가시화 연구(III))

  • Kim, Kyung Chun;Shin, Dae Sig;Park, Kee Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.11
    • /
    • pp.1571-1581
    • /
    • 1998
  • A flow visualization study was carried out for the branch pipe mixing flow in which a jet was issued normally to the fully developed pipe flow. An instantaneous laser tomographic method was used for cross flow Reynolds numbers based on the cross flow diameter D ranged $Re_{cf}=5.26{\times}10^3{\sim}1.13{\times}10^4$, diameter ratios d/D = 0.1 ~ 0.2 and velocity ratios R = 0.5 ~ 10. Oil mist with the size of about $10{\mu}m$ diameter was used for the scattering particle. The main purpose of this study was to reveal the physical mechanism and the structure of vortices formation with varying the velocity ratios and diameter ratios in the branch pipe flow. It was found that the physical mechanism and the structures of vortices formation were quite different depending on the velocity ratios. Particularly in the case of R < 1, the typical vortex shows single loop shape and that for the case of R > 1 depicts mushroom-like structure in the cross flow jet.

A Study on The Φ 9mm Titanium Alloy Wire (9mm 합금타이타늄 중간 선재 연구)

  • Kim, Sang-Yeoun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.1
    • /
    • pp.8-13
    • /
    • 2012
  • Ti-3Al-2.5V ingot was produced, processed into a titanium alloy wire of 9mm diameter, and the characteristics were studied in comparison with imported material. The ingot satisfied ASTM Grade 9 standard showing oxygen content of 0.11wt% and iron content of 0.085wt%. The hardness of the 9mm diameter titanium alloy was similar to that of the imported material showing values between 225 and 250Hv, and the tensile strength of the imported material was 804MPa while that of the domestic development was 734MPa. The elongation of the imported material was 12% while that of the domestic development was 22%. A new process of manufacturing 9.0mm diameter titanium alloy wire through forging and multi-step hot rolling process out of 400mm diameter ingot was developed.

[ $PERIOTEST^{(R)}$ ] ASSESSMENT OF DENTAL IMPLANT MOBILITY : A CLINCAL STUDY ($PerioTest^{(R)}$를 이용한 임플란트 동요도에 관한 임상적 연구)

  • Kim, Sun-Jai;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.5
    • /
    • pp.758-771
    • /
    • 1998
  • Assessment of implant mobility is an important and reliable method to clinically evaluate implant stability. PerioTest is a precise and reproducible device that cam dynamically measure the reaction of damping characteristics of peri-implant tissue. The aim of this study is to evaluate the effects of amount of implant surface area, diameter, type, implantation site, degrees of cortical engagement, and length of time in function on PTVs and to find out the most determining factor on PTVs. The results are as follows 1. 5.0mm diameter implants show significantly lower PTV than that of 3.75mm diameter implants. 2. PTV in the mandible is significantly lower than that of the maxilla 3. In the maxilla, there is no significant difference in PTV during the first year of implant function, but during the second year a significant decrease in PTV is noted. 4. In the mandible, there is a significant decrease in PTV during the first and second year of implant function. 5. Implantation site seems to be the most determining factor on PTV among the influencing factors in this study. In conclusion, the amount of implant surface area, type, degrees of cortical engagement had no significant effect on PTV, but installation site and diameter influenced significantly on PTV

  • PDF

Capillary Flow in Different Cells of Ginkgo Biloba, Diospyros Kaki and Ailanthus Altissima (은행나무, 감나무, 가중나무 세포내강의 액체이동)

  • Chun, Su Kyoung
    • Journal of the Korea Furniture Society
    • /
    • v.26 no.2
    • /
    • pp.179-185
    • /
    • 2015
  • A study was carried out to observe the 1% aqueous safranine solution flow speed in longitudinal and radial directions of softwood G. biloba, ring-porous wood A. altissima, and diffuse- porouswood D. kaki. In radial direction, ray cells and in longitudinal direction tracheids, vessel and wood fiber were considered for the measurement of liquid penetration speed at less than 12% moisture contents (MC). The length, lumen diameter, pit diameter, end wall pit diameter and the numbers of end wall pits determined for the flow rate. The liquid flow in the those cells was captured via video and the capillary flow rate in the ones were measured. Vessel in hardwood species and tracheids in softwood was found to facilitate prime role in longitudinal penetration. Radial flow speed was found highest in ray parenchyma of G. biloba. Anatomical features like the length and diameter, end-wall pit numbers of ray parenchyma were found also responsible fluid flow differences. On the other hand, vessel and fiber structure affected the longitudinal flow of liquids. Therefore, the average liquid penetration depth in longitudinal tracheids of G. biloba was found the highest among all cells considered in D. kaki and A. altissima.

Ice Making Characteristics according to Shape and Diameter on Ice-on-Coil Tube (관외착빙형 제빙관의 형태 및 관경 변화에 따른 제빙 특성)

  • Park, K.W.;Jeong, E.H.;Hwang, S.S.
    • Journal of Power System Engineering
    • /
    • v.16 no.5
    • /
    • pp.32-39
    • /
    • 2012
  • The study experimented to understand ice-on-coil type ice making characteristics on to 3 kinds of circular tube, oval tube and small diameter tube using ice maker. The experiment were carried out under various conditions, that used brine temperature($-10^{\circ}C$, $-6^{\circ}C$), brine flow rate(1.0m/s, 1.8m/s) and inlet water temperature ($6^{\circ}C$, $12^{\circ}C$) etc. Mass of ice per ice making area increased according to the decrease of the brine temperature and inlet water temperature, but that was increased according to the increase of the brine flow rate. Oval ice making tube produced ice 1.11 to 2.46 times that of 9mm circular ice making tube, and 3mm small diameter ice making tube produced ice 1.06 to 1.51 times that of 9mm circular ice making tube.

The Effect of Gap Size on Counter Current Flow Limitation Phenomena in Narrow Annular Gaps with Large Diameter

  • Jeong, Ji-Hwan;Lee, Seung-Jin;Park, Rae-Joon;Kim, Sang-Baek
    • Nuclear Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.396-405
    • /
    • 2002
  • An experimental study on counter-current flow limitation phenomena in narrow annular passages was carried out The gap sizes tested were 1, 2 and 3 mm. This is very small compared with the outer diameter of the annular passage, 500 mm. It was visually observed that a CCFL might occur in some part of the periphery while the other part is remained in a counter current flow pattern. That is, non-uniform behaviour of fluids due 4o a 2-dimensional effect appear in a large diameter facility. Because of this non-uniformity, a CCFL is defined in the present work as the situation where net water accumulation is sustained. That is, some amount of water should not be allowed to penetrate the gap and accumulate over the gap at CCFL criterion. The measured data are presented in the form of Wallis'type correlation with characteristic length of gap size. It was found that the present correlation is in good agreement with other empirical correlation based on measurements whose test section diameter is close and the gap size is much larger than that of the present test section.

Static strengths of preloaded circular hollow section stub columns strengthened with carbon fiber reinforced polymer

  • Chen Wei;Yongbo Shao;Mostafa Fahmi Hassanein;Chuannan Xiong;Hongmei Zhu
    • Steel and Composite Structures
    • /
    • v.47 no.4
    • /
    • pp.455-466
    • /
    • 2023
  • To investigate the load bearing capacity of axially preloaded circular hollow section (CHS) stub columns strengthened by carbon fiber reinforced polymer (CFRP), theoretical analysis is carried out. The yield strength and the ultimate strength of a CFRP strengthened preloaded CHS stub column are determined at the yielding of the CHS tube and at the CFRP fracture, respectively. Theoretical models are proposed and corresponding equations for calculating the static strengths, including the yield strength and the ultimate strength, are presented. Through comparison with reported experimental results, the theoretical predictions on the static strengths are proved to be accurate. Through finite element (FE) analyses, parametric studies for 258 models of CFRP strengthened preloaded CHS stub columns are conducted by considering different values of tube diameter, tube thickness, CFRP layer and preloading level. The static strengths of the 258 models predicted from presented equations are proved to be in good agreement with FE simulations when the diameter-to-thickness ratio is less than 90ε2. The parametric study indicates that the diameter and the thickness of the steel tube have great effects on CFRP strengthening efficiency, and the recommended ranges of the diameter and the thickness are proposed.

Pull-out Capacity of Screw Anchor Pile in Sand Using Reduced-Scale Model Tests (축소모형실험을 이용한 사질토 지반에 근입된 Screw Anchor Pile의 인발저항특성)

  • Kim, Dae-Hyun;Yoo, Chung-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.1
    • /
    • pp.121-133
    • /
    • 2013
  • This paper presents the results of an investigation into the pull-out capacity characteristics of screw anchor piles. Theoretical background of screw anchor pile (SAP) was first discussed. A series of reduced-scale model tests were performed on a number of cases with different SAP geometries such as pitch and diameter of screw as well as relative density of the model ground. The applicability of the pull-out capacity prediction equations were also examined based on the test results. It was shown that the pitch of screw has negligible effect on the pull-out capacity, while the diameter of screw has relatively large effect on pull-out capacity under a given condition. Practical implications of the findings from this study are discussed in great detail.