• 제목/요약/키워드: Out Layer Removal

검색결과 90건 처리시간 0.026초

The Impact of the Morphological Characteristics of Leaves on Particulate Matter Removal Efficiency of Plants

  • Son, Deokjoo;Kim, Kwang Jin;Jeong, Na Ra;Yun, Hyung Gewon;Han, Seung Won;Kim, Jeongho;Do, Gyung-Ran;Lee, Seon Hwa;Shagol, Charlotte C.
    • 인간식물환경학회지
    • /
    • 제22권6호
    • /
    • pp.551-561
    • /
    • 2019
  • This study was conducted to find out differences in the removal efficiency of particulate matter (PM) depending on the type of plants and the morphological characteristics of leaves. A total of 12 plants were used, with three plants selected for each type of leaves (big leaf, small leaf, compound leaf, needle leaf). We measured the removed amount of PM10 and PM2.5, the structure of the abaxial leaf surface, and the weight of the wax layer of each plant. Plants with the high removal efficiency of PM included Pachira aquatica Aubl., Ardisia crenata, and Dieffenbachia 'Marianne', and plants with the low removal efficiency included Nandina domestica Thunb, Schefflera arboricola, and Quercus dentata. The abaxial leaf surface having a high removal efficiency of PM had many large wrinkles, and the abaxial leaf surface having a medium removal efficiency was flat and smooth. On the other hand, there were many fine hairs on the abaxial leaf surface with a low removal efficiency. According to the plant leaf type, the PM10 removal efficiency of plants with needle leaves was about three times higher than that of other plants. In particular, the wax layer of conifers weighed 6-24 times higher than those of other plants. The stomata of conifers were evenly distributed on the adaxial and abaxial leaf surfaces; however, the stomata of Sciadopitys verticillata appeared in the form of papillae unlike general stomata. Therefore, the removal efficiency of PM varied depending on the macro-, and micro-morphological characteristics of plant leaves such as the structure of the abaxial leaf surface, and the weight of the wax layer. Based on this research, selecting plants that are effective in reducing PM in consideration of the plant type and leaf characteristics will improve indoor air quality and decrease exposure of PM to human body.

고수부지에 조성한 수질정화 여과습지의 초기운영단계 총인 제거 (Total Phosphorus Removal Rate of a Subsurface-Flow Wetland System Constructed on Floodplain During Its Initial Operation Stage)

  • 양홍모
    • 한국환경복원기술학회지
    • /
    • 제6권6호
    • /
    • pp.49-55
    • /
    • 2003
  • Total phosphorous removal rate was examined of a subsurface-flow treatment wetland system which was constructed on floodplain in the down reach of the Kwangju Stream in Korea from May to June 2001. Its dimensions were 29 meter in length, 9 meter in width and 0.65 meter in depth. A bottom layer of 45 cm in depth was filled with crushed granite with about 15~30 mm in diameter and a middle layer of 10 cm in depth had pea pebbles with about 10 mm in diameter. An upper layer of 5 cm in depth contained course sand. Reeds(Phragmites australis) were transplanted on the surface of the system. They were dug out of natural wetlands and stems were cut at about 40 cm height from their bottom ends. Water of the Kwangju Stream flowed from a submerged dam into it via a pipe by gravity flow and treated effluent was funneled back into the Stream. The number of reed stems increased from 80 stems/$m^2$ in July 2001 to 136 stems/$m^2$ in September 2001. The hight of stems was 44.2 cm in July 2001 and 75.3 cm in September 2001. The establishment of reeds at early operating stage of the system was good. Volume and water quality of inflow and outflow were investigated from July 2001 through December 2001. The average inflow was 40 $m^3$/day and hydraulic detention time was about 1.5 days. The concentration of total phosphorous n influent and effluent was 0.83 and 0.33 mg/L, respectively. The removal rate of total phosphorous averaged about 60%. The removal efficiency was slightly higher, compared with that of subsurface-flow wetlands operating in North America, whose retention rate of total phosphorous was reported to be about 56%. The good abatement rate could be attributed to sedimentation of particle phosphorous in pores of the media and adsorption of phosphorous to the biofilm developed on the surface of them. Increase of standing density of reeds within a few years will develop root zones which may lead to increment in the phosphorous retention rate.

Out-layer를 제거한 End to End 자율주행 시스템 (End to End Autonomous Driving System using Out-layer Removal)

  • 정승혁;윤동호;홍성훈
    • 사물인터넷융복합논문지
    • /
    • 제9권1호
    • /
    • pp.65-70
    • /
    • 2023
  • 본 논문에서는 비전 센서 기반 시스템의 차선 이탈과 신호등 오인식 등을 개선하기 위해 End to End 모델을 활용한 자율주행 시스템을 제안한다. End to End 학습은 다양한 환경 조건에 대해 확장을 할 수 있다. 비전 센서 기반 모형 자동차를 이용하여 주행 데이터를 수집한다. 수집한 데이터를 이용하여 기존의 데이터와 아웃레이어를 제거한 데이터로 구성한다. 입력 데이터인 카메라 이미지 데이터, 출력 데이터인 속도와 조향 데이터로 클래스를 구성하고 End to End 모델을 활용하여 데이터 학습을 수행하였다. 학습된 모델의 신뢰성을 확인했다. 모형 자동차에 학습한 End to End 모델을 적용하여 이미지 데이터로 조향각을 예측한다. 모형 자동차의 학습 결과, 아웃레이어를 제거한 모델이 기존 모델보다 향상된 것을 볼 수 있다.

Monosulfate ($Ca_4Al_2O_6(SO_4){\cdot}12H_2O$)의 특성 및 수중 5가 비소 제거기작 규명 (The investigation of As(V) removal mechanism using monosulfate (($Ca_4Al_2O_6(SO_4){\cdot}12H_2O$) and its characteristics)

  • 김기백;심재호;최원호;박주양
    • 상하수도학회지
    • /
    • 제26권1호
    • /
    • pp.149-157
    • /
    • 2012
  • Experiments for As(V) removal using synthesized $Ca{\cdot}Al$-monosulfate was performed from the water contaminated with arsenate. Monosulfate is known as LDHs (Layered Double Hydroxides) which is one of the anionic clay minerals. Monosulfate was synthesized mixing $C_3A$ (tricalcium aluminate), gypsum (calcium sulfate), and water with an intercalation method. The product form the synthesis was characterized by FE-SEM, WDXRF, PXRD, and FT-IR. Experiments with different doses of monosulfate were carried out for kinetic. As a result of experiment, the concentration of As(V) was reduced from 0.67 mM to 0.19 mM (0.67mM of monosulfate) and 0.178 mM (1.34 mM of monosulfate). The concentration of sulfate was increased with As(V) decrease. The result of PXRD showed that the d-spacing of inter layer ($d_{003}$ peak) was shifted from 8.927 ${\AA}$ to 8.095 ${\AA}$ because the sulfate in the inter layer of monosulfate was exchanged arsenate with water molecules bonded. From the FT-IR results, a new single band (800 cm-1) was observed after the reaction of monosulfate and As(V). The arsenic removal can be regarded as anion exchange mechanism that is one of the characteristics of LDHs from the results of PXRD and FT-IR analysis.

Removing nitrogenous compounds from landfill leachate using electrochemical techniques

  • Nanayakkara, Nadeeshani;Koralage, Asanga;Meegoda, Charuka;Kariyawasam, Supun
    • Environmental Engineering Research
    • /
    • 제24권2호
    • /
    • pp.339-346
    • /
    • 2019
  • In this research, applicability of electrochemical technology in removing nitrogenous compounds from solid waste landfill leachate was examined. Novel cathode material was developed at laboratory by introducing a Cu layer on Al substrate (Cu/Al). Al and mild steel (MS) anodes were investigated for the efficiency in removing nitrogenous compounds from actual leachate samples collected from two open dump sites. Al anode showed better performances due to the effect of better electrocoagulation at Al surface compared to that at MS anode surface. Efficiency studies were carried out at a current density of $20mA/cm^2$ and at reaction duration of 6 h. Efficiency of removing nitrate-N using Al anode and developed Cu/Al cathode was around 90%. However, for raw leachate, total nitrogen (TN) removal efficiency was only around 30%. This is due to low ammonium-N removal as a result of low oxidation ability of Al. In addition to the removal of nitrogenous compounds, reactor showed about 30% removal of total organic carbon. Subsequently, raw leachate was diluted four times, to simulate pre-treated leachate. The diluted leachate was treated and around 88% removal of TN was achieved. Therefore, it can be said that the reactor would be good as a secondary or tertiary treatment step in a leachate treatment plant.

EDTA의 세정시간에 따른 근관 내 smear layer의 제거효과에 관한 연구 (TIME-DEPENDENT EFFECTS OF EDTA APPLICATION ON REMOVAL OF SMEAR LAYER IN THE ROOT CANAL SYSTEM)

  • 이자경;박상혁;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제31권3호
    • /
    • pp.169-178
    • /
    • 2006
  • 본 연구는 EDTA용액의 적용 시간에 따른 도말층의 제거 효과를 비교하여 EDTA용액의 최적 적용 시간을 알고자 시행되었다. 단근치 35개를 NaOCl 용액 하에서 근관 형성 후 대조군은 NaOCl 용액 5 ml로 2분간, 실험군은 30초군, 1분군, 2분군으로 세분하여 17% EDTA 용액 5 ml로 각각 30초, 1분, 2분간 세정하였다. 세정이 끝난 치근의 도말층 제거 정도와 상아 세관의 erosion 정도를 주사전자현미경을 이용하여 관찰한 결과는 다음과 같다. 1. 대조군: 도말층이 전혀 제거되지 않았다. 2. 실험군 1) 중간$\frac{1}{3}$: 세 군 모두에서 도말층이 거의 완전히 제거되었고, EDTA적용 시간이 증가할수록 erosion발생 빈도가 증가하였다. 2) 치근단$\frac{1}{3}$: 2분군이 다른 두 군에 비해 도말층 제거 정도가 우수하였다. 따라서 erosion 발생을 최소화면서 도말층을 효과적으로 제거하기 위해서는 17% EDTA 용액을 2분간 사용하는 것이 적절한 것으로 사료된다.

Potential use of waste rubber shreds in drainage layer of landfills - An experimental study

  • Praveen, V.;Sunil, B.M.
    • Advances in environmental research
    • /
    • 제5권3호
    • /
    • pp.201-211
    • /
    • 2016
  • Laboratory tests were conducted to evaluate the performance of waste rubber shreds in leachate collection layer of engineered landfills. The study found that waste rubber shreds layer in combination with a gravel layer can be of potential use in landfill drainage system. To study the performance, conventional gravel along with waste rubber shreds were used in different combinations (with total layer thickness = 500 mm) as leachate collection media. For the laboratory study poly vinyl chloride (PVC) pipes were used. The size range of waste rubber shreds used were 25 mm to 75 mm in length and width = 10 to 20 mm. The gravel size used in the leachate collection media is 10 mm to 20 mm size. Performance study of 7 Test Cols. with different combinations of waste rubber shreds and gravel bed thickness were studied to find out the best combination. The study found that the Test Col.-3 having waste rubber shreds thickness = 200 mm and gravel layer thickness = 300 mm gave the best results in terms of percentage removal in various physicochemical parameters present in the leachate. Further to find the best size rubber shreds three more Test Cols - 8, 9 and 10 were constructed having the rubber shreds and gravel layer ratio same as that of Test Col.-3 but having rubber shreds width = 10 mm, 15 mm and 20 mm respectively. Based on the results obtained using Test Cols. 8, 9 and 10 the study found that smaller size rubber shreds gave bests results in terms of improvement in various leachate parameters.

광산폐석의 효과적 처리를 위한 지화학적 연구 (Geochemical Experiment for Effective Treatment of Abandoned Mine Wastes)

  • 이진국;이재영
    • 한국토양환경학회지
    • /
    • 제3권1호
    • /
    • pp.31-44
    • /
    • 1998
  • 본 연구는 중금속원소의 주오염원 중의 하나인 금속폐광산에 다량 잔존하는 폐석을 효율적으로 처리하기 위해 실내모형시험을 수행하였으며, 그 결과를 광산폐석처리의 기술개발에 기초자료로 활용하고자 한다. 실험의 도구는 실험결과에 거의 영향이 없는 내산성 내알카리성의 아크릴산수지와 폴리에틸렌 관을 사용하였다. 본 연구에서 제작 운용된 8개의 모형을 계내의 환경, 충진물의 배열방식 및 종류 등으로 분류한다면 4개의 그룹으로 나눌 수 있다. 그룹 1은 계내에 폐석으로만 충진하여 개방계에서 실험한 배경모델이고, 그룹 2는 각각 두 개의 폐석층과 석회암편층을 층상으로 배열한 뒤 개방계와 폐쇄계로 구분하여 실험하였다. 그룹 3은 폐석과 석회암편을 골고루 잘 섞어 계내에 충진하고(혼합모델)이를 개방계와 폐쇄계로 구분하여 실험하였으며, 마지막 그룹 4는 폐석층의 표층부에 석회암편층을 가하여 실험하였다. 배경모델인 모델 Ⅰ로부터 배수된 시수는 실험초기부터 말기까지 중금속원소의 용존량이 매우 높다. 그런, 다른 모델에 비해 그룹 3에 해당되는 모델 Ⅴ와 Ⅶ은 중금속원소의 함량이 매우 낮아 제거효과가 가장 높은 것으로 나타났다. 폐쇄된 혼합모델에서 폐석과 석회암편의 혼합비를 1:1, 2:1로 달리하더라도 중금속원소의 제거효과 는 대동소이한 것으로 나타났다. 그러나, 계내를 같은량의 충진물로 충진하더라도 혼합모델은 층상모델에 비해 중금속원소의 제거효과가 현저히 높다. 그리고, 다른 실험조건이 같은 폐쇄계와 개방계를 비교하면 전자의 중금속원소의 제거효과가 다소 높은 것으로 나타났다.

  • PDF

Effect of irrigation protocols on smear layer removal, bond strength and nanoleakage of fiber posts using a self-adhesive resin cement

  • Rodrigo Stadler Alessi;Renata Terumi Jitumori ;Bruna Fortes Bittencourt;Giovana Mongruel Gomes ;Joao Carlos Gomes
    • Restorative Dentistry and Endodontics
    • /
    • 제48권3호
    • /
    • pp.28.1-28.13
    • /
    • 2023
  • Objectives: This study aimed to investigate the effect of the application method of 2% chlorhexidine (CHX) and its influence on the adhesion of fiberglass posts cemented with a self-adhesive resin cement. Materials and Methods: Sixty human mandibular premolars were endodontically treated and divided into 5 groups (n = 12), according to the canal irrigant and its application method: 2 groups with conventional syringe irrigation (CSI)-2.5% sodium hypochlorite (NaOCl) (control) and 2% CHX- and 3 groups with 2% CHX irrigation/activation-by passive ultrasonic irrigation (PUI), Easy Clean file, and XP-Endo Finisher file. Two roots per group were evaluated for smear layer (SL) removal by scanning electron microscopy. For other roots, fiber posts were luted using a self-adhesive resin cement. The roots were sectioned into 6 slices for push-out bond strength (BS) (7/group) and nanoleakage (NL) (3/group). Data from SL removal were submitted to Kruskal-Wallis and Student-Newman-Keuls tests (α = 0.05). Data from BS and NL were evaluated by 2-way analysis of variance and Tukey's test (α = 0.05). Results: For SL removal and BS, the CHX irrigation/activation promoted better values than CSI with CHX (p < 0.05), but it was not significantly different from CSI with NaOCl (p > 0.05). For NL, the lowest values were obtained by the chlorhexidine irrigation/activation groups (p < 0.05). Conclusions: Active 2% CHX irrigation can be used to improve the post space cleaning and adhesion before fiber post cementation with self-adhesive resin cements.

Band Alignment at CdS/wide-band-gap Cu(In,Ga)Se2 Hetero-junction by using PES/IPES

  • Kong, Sok-Hyun;Kima, Kyung-Hwan
    • Transactions on Electrical and Electronic Materials
    • /
    • 제6권5호
    • /
    • pp.229-232
    • /
    • 2005
  • Direct characterization of band alignment at chemical bath deposition $(CBD)-CdS/Cu_{0.93}(In_{1-x}Ga_x)Se_2$ has been carried out by photoemission spectroscopy (PES) and inverse photoemission spectroscopy (IPES). Ar ion beam etching at the condition of the low ion kinetic energy of 400 eV yields a removal of surface contamination as well as successful development of intrinsic feature of each layer and the interfaces. Especially interior regions of the wide gap CIGS layers with a band gap of $1.4\~1.6\;eV$ were successfully exposed. IPES spectra revealed that conduction band offset (CBO) at the interface region over the wide gap CIGS of x = 0.60 and 0.75 was negative, where the conduction band minimum of CdS was lower than that of CIGS. It was also observed that an energy spacing between conduction band minimum (CBM) of CdS layer and valance band maximum (VBM) of $Cu_{0.93}(In_{0.25}Ga_{0.75})Se_2$ layer at interface region was no wider than that of the interface over the $Cu_{0.93}(In_{0.60}Ga_{0.40})Se_2$ layer.