• 제목/요약/키워드: Ottawa sand

검색결과 25건 처리시간 0.024초

Standard sand for geotechnical engineering and geoenvironmental research in Nigeria: Igbokoda sand

  • Ojuri, Oluwapelumi O.;Fijabia, David O.
    • Advances in environmental research
    • /
    • 제1권4호
    • /
    • pp.305-321
    • /
    • 2012
  • This study entails establishing reference standard sand in Nigeria for engineering and geoenvironmental research work. Sands from four geographical locations in southwestern Nigeria were examined for baseline geotechnical and mineralogical properties. A total of sixteen sand samples were collected. The samples were air dried and subjected to tests in accordance with standard specifications. The tests carried out were: specific gravity, grain size analysis, moisture content, bulk density, porosity, void ratio, chemical analysis, X-ray diffraction and Differential Thermal Analysis. The properties of the samples were compared with a standard (Ottawa sand in Illinois of the United States) in order to find out which of the four samples selected from southwestern Nigeria could serve as standard baseline sand. The results show that Igbokoda sand has geotechnical and mineralogical characteristics closest to Ottawa sand. It was therefore concluded that Igbokoda sand could be used as a standard baseline sand for research work in southwestern Nigeria and other parts of Nigeria since it needs little processing to bring it to the same level as standard baseline sand, like the Ottawa sand.

토양증기추출(Soil Vapor Extraction)을 이용한 토양 내 Trichloroethylene (TCE)과 Toluene정화 실험 (Laboratory Tests for Trichloroethylene (TCE) and Toluene Remediation in Soil Using Soil Vapor Extraction)

  • 이민희;강현민
    • 자원환경지질
    • /
    • 제35권3호
    • /
    • pp.221-227
    • /
    • 2002
  • 토양증기추출(Soil Vapor Extraction)법을 이용하며 대표적 휘발성 NAPL(Non-aqueous phase liquid)인 TCE (trichloroethylene)와 toluene을 토양으로부터 제거하는 칼럼 실험을 실시하였다. 균질한 Ottawa sand와 실제 오염지역의 토앙들이 사용되었으며, 토양특성 및 증기추출 조건들이 정화효율에 미치는 영향을 규명하였다. 직경 2.5cm, 길이 30cm인 유리 칼럼이 사용되었고, 붉은색으로 염색된 TCE 또는 toluene 4 gram이 주입되었다 주입 공기가 일정한 속도로 칼림 내에 주입될 수 있도록 공기 유량계를 설치하여 0.03 L/min의 일정한 속도로 공기가 주입되도록 하고, 퍼지 장치를 설치하여 주입 공기의 습윤도를 99% 이상으로 유지하였다. 칼럼으로부터 유출되는 가스는 자동 가스시료주입 밸브장치를 이용하여 가스크로마토그래피 칼럼 내로 주입되게 하여, FID 검출기로 유출 가스 농도를 분석하였다. Ottawa sand로 충진된 칼럼실험에서는 매질의 입자크기, 함수율, 토양 내 오염물 체류시간 등을 변화시켜 실험을 반복하였다. TCE로 오염된 세립질 Ottawa sand 칼럼실험에서 유출 공기의 최대 농도는 조립질 Ottawa sand 칼럼의 유출 농도보다 약 20% 정도 감소하였고, 오염지역의 실제토양 칼럼실험에서는 최대유출농도가 조립질 Ottawa sand칼럼의 농도보다 약 50% 감소하였으나, 20 liter 공기 주입 후부터는 모두 비슷한 농도감소 현상을 나타내었으며 초기 주입량의 90 % 이상이 제거되었다. 함수율증가에 따른 유출공기의 농도 감소는 거의 나타나지 않았으며, TCE 주입 후 7일 동안 방치하였다가 SVE를 실시한 칼럼 실험에서도 잔류하는 TCE의 양이 약간 증가하였지만 20liter 공기 추출 후에는 초기 주입량의 90% 가, 40 liter 공기 추출 후에는 98% 이상이 제거되었다. Toluene 으로 오염된 칼럼 실험에서도 TCE와 비슷한 제거 경향을 나타냈으며 200 liter 공기 추출 후에는 오염물 초기 주입량의 98% 이상이 제거되었다. 본 실험 결과로부터 증기추출법을 이용한 TCE, toluene 정화 효율성이 규명되었으며, 휘발성 NAPL로 오염된 실제 토양을 복원하기위한 SVE법의 적용가능성을 확인할 수 있었다.

토양의 특성에 따른 토양증기추출법 (Soil Vapor Extraction)의 Trichloroethylene (TCE)과 Toluene 정화 효율 실험

  • 강현민;이민희;정상용
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 총회 및 춘계학술발표회
    • /
    • pp.191-194
    • /
    • 2002
  • 토양증기추출(Soil Vapor Extraction)법을 이용하여 대표적 휘발성 NAPL (Non-aqueous phase liquid)인 TCE (trichloroethylene)와 toluene을 토양으로부터 제거하는 칼럼 실험을 실시하였다. 토양특성 및 증기추출 조건들이 정화효율에 미치는 영향을 규명하는데, 균질한 Ottawa sand와 실제 오염지역의 토양들을 직경 2.5cm, 길이 30cm인 유리 칼럼이 충진시켰으며, 빨갛게 염색된 TCE 또는 toluene 4 g이 주입되었다 공기 유량계를 설치하여 0.03L/min의 일정한 속도로 공기가 주입되도록 하고, 퍼지장치를 설치하여 주입 공기의 습윤도를 99% 이상으로 유지하였다. 가스크로마토그래피로 유출 가스 농도를 분석하였다. Ottawa sand로 충진된 칼럼실험에서는 매질의 입자크기, 함수율, 토양 내 오염물 체류시간 등을 변화시켜 실험을 반복하였다. TCE로 오염된 세립질 Ottawa sand 칼럼실험에서 유출 공기의 최대 농도는 조립질 Ottawa sand 칼럼의 유출 농도보다 약 20% 정도 감소하였고, 오염지역의 실제토양 칼럼실험에서는 최대유출농도가 조립질 Ottawa sand 칼럼의 농도보다 약 50% 감소하였으나, 20 liter공기 주입 후부터는 모두 비슷한 농도감소 현상을 나타내었으며, 초기 주입량의 90 % 이상이 제거되었다. 함수율증가에 따른 유출공기의 농도 감소는 거의 나타나지 않았으며, TCE 주입 후 7일 동안 방치하였다가 SVE를 실시한 칼럼 실험에서도 잔류하는 TCE의 양이 약간 증가하였지만 20 liter 공기 추출 후에는 초기 주입량의 90% 가, 40 liter공기 추출 후에는 98% 이상이 제거되었다. Toluene으로 오염된 칼럼 실험에서도 TCE와 비슷한 제거 경향을 나타냈으며 200 liter 공기 추출 후에는 오염물 초기 주입량의 98% 이상이 제거되었다. 본 실험 결과로부터 증기추출법을 이용한 TCE, toluene 정화 효율성이 규명되었으며, 휘발성 NAPL로 오염된 실제 토양을 복원하기 위한 SVE법의 적용가능성을 확인할 수 있었다.

  • PDF

Generalized Schmertmann Equation for settlement estimation of shallow footings in saturated and unsaturated sands

  • Mohamed, Fathi M.O.;Vanapalli, Sai K.;Saatcioglu, Murat
    • Geomechanics and Engineering
    • /
    • 제5권4호
    • /
    • pp.343-362
    • /
    • 2013
  • Simple relationships are proposed in this paper by modifying the Schmertmann's equation for settlement estimations of footings (i.e., $B/L{\approx}1$) carrying vertical loads in saturated and unsaturated sandy soils. The modified method is developed using model plate load tests (PLTs) and cone penetration tests (CPTs) results conducted in saturated and unsaturated sand in a controlled laboratory environment. Seven in-situ large-scale footings tested under both saturated and unsaturated conditions in sands were used to validate the proposed technique. The results of the study are encouraging as they provide reliable estimates of the settlement of shallow footings in both saturated and unsaturated sands using the conventional CPT results.

反復荷重을 받는 흙의 構成關係式 開發 (Development of Constitutive Equation for Soils Under Cyclic Loading Conditions)

  • 장병욱;송창섭
    • 한국농공학회지
    • /
    • 제34권1호
    • /
    • pp.41-48
    • /
    • 1992
  • Various soil behaviors usually occurring in the geotechnical problems, such as, cutting and embankments, stability of slope, seepage, consolidations, shearing failures and liquefaction, should be predicted and analyzed in any way. An approach of these predictions may be followed by the development of the constitutive equations as first and subsequently solved by numerical methods. The purpose of this paper is develop the constitutive equation of sands uder monotonic or cyclic loadings. The constitutive equation which is based on elasto-plastic theory, modified anisotropic consolidated stress parameter by Sekiguchi et al and Pender's theory is derived. And the equation is included a new stress parameter, hardening function, Bauschinger's effects and Pender's theory. The model is later evaluated and confirmed the validity by the test data of Ottawa sand, Banwol sand Hongseong sand. The following conclustions may be drawn: 1. The consititutive equation which is based on elasto-plastic theory, modified anisotropic consolidated stress parpameter by Sekiguchi et al and Pender's theory is derived. The equation in included a new stress parameter, hardening function, Bauschinger's effect and Pender's theory. 2. For Ottawa sand, the result of the constitutive equation shows a better agreement than that of Oka et al. The result of axial strain agrees well with the tested data. However, the result of horizontal strain is little bit off for the cyclic loadings or large stress. It is thought that the deviation may be improved by considering Poisson's ratio and precise measurement of shear modulus. 3. Banwol sand is used for the strain and stress tests with different relative densitites and confining pressures. The predeicted result shows a good agreement with the tested data because the required material parameters were directly measurd and determined form this laboratory. 4. For Hongseong sand, the tests under same amplitude of cyclic deviatoric stress shows a similar result with the tested data in absolute strain. It shows the acute shape of turning point because the sine wave of input is used in the test but the serrated wave in prediction.

  • PDF

습윤 모래에서 인장강도의 예측 (II) : 검증 (Prediction of Tensile Strength of Wet Sand (II) : Validation)

  • 김태형
    • 한국지반공학회논문집
    • /
    • 제24권6호
    • /
    • pp.37-44
    • /
    • 2008
  • 낮은 응력 상태에서 모래의 인장강도는 포화도 또는 흡입력에 따라 증가하다 최대값이 이른 후 감소한다. 최대인장 강도는 어느 포화도에서든 발생될 수 있다. 선행 연구에서는 이와 같은 습윤 모래의 인장강도를 정확히 표현한 이론이 제시되었다. 본 연구에서 세 가지 종류의 모래(워싱턴 주 시애틀의 검정 Esperance모래, 오스트리일리아 서부 Perth 해변 모래, Ottawa 모래)에 대해 실시된 일축인장실험, 함수특성실험, 직접전단실험 결과를 이용하여 제안된 이론을 검증하였다. 제안된 닫힌 형식의 식으로 표현된 이론은 이들 모래들로부터 얻어진 실험결과와 비교 시 전체 포화도 영역에서 인장강도 변화양상, 인장강도 크기, 최대인장강도, 최대인장강도가 발생할 때의 해당 포화도 등을 잘 예측하는 것으로 나타났다.

점토질 모래의 투수 및 압밀 특성 평가 (Permeability and Consolidation Characteristics on Clayey Sand Soils)

  • 김광균;박두희;장재훈
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.971-980
    • /
    • 2010
  • Evaluation of permeability and coefficient of consolidation of clayey sand is critical to analyze ground stability or environmental problems such as diffusion and dispersion in groundwater flow. Permeability tests using a flexible wall permeameter were performed to derive the coefficient of consolidation and permeability of reconstituted soil samples with various mixing ratios of kaolin clays and two different types of sands, Jumunjin sand and Ottawa sand. The test results indicated that coefficient of consolidation and permeability in log scale have linear relationships with clay contents in low clay mixing ratio. It is also recognized that coefficient of consolidation and permeability of sand and clay mixture are also dependent on the soil structure.

  • PDF

현장실험 및 동적실내실험을 이용한 포항지역 동적 지반특성 평가 (Evaluation of Dynamic Ground Properties of Pohang Area Based on In-situ and Laboratory Test)

  • 김종관;곽태영;한진태;황병윤;김기석
    • 한국지반공학회논문집
    • /
    • 제36권9호
    • /
    • pp.5-20
    • /
    • 2020
  • 2017년 발생한 포항지진에서는 계기지진 이래 처음으로 액상화 현상이 목격되었다. 본 연구에서는 액상화 현상이 목격된 포항시 (1) 송림공원, (2) 흥해읍 망천리, (3) 흥안리를 대상으로 다양한 지반조사 및 실내실험을 수행하였다. 액상화 발생위치의 동적특성을 파악하기 위해 지반조사 항목으로는 표준관입시험(SPT), 콘관입시험(CPT), 표면파탐사(MASW), 밀도검층, 다운홀테스트, 전기비저항탐사를 수행하였고, 현장에서 채취한 시료를 바탕으로 진동삼축압축 시험기를 통해 액상화실험을 수행하였다. 그 결과 세 곳 모두 지하수위가 높고 얕은 심도에 연약한 모래층이 존재하며, 송림공원에서 채취한 모래는 주문진 표준사, Toyoura 모래, Ottawa 모래에 비해 액상화 저항강도가 작은 것을 확인하였다.

Mechanical behaviour of biocemented sand under triaxial consolidated undrained or constant shear drained conditions

  • Hang, Lei;Gao, Yufeng;He, Jia;Chu, Jian
    • Geomechanics and Engineering
    • /
    • 제17권5호
    • /
    • pp.497-505
    • /
    • 2019
  • Biocementation based on the microbially induced calcite precipitation (MICP) process is a novel soil improvement method. Biocement can improve significantly the properties of soils by binding soil particles to increase the shear strength or filling in the pores to reduce the permeability of soil. In this paper, results of triaxial consolidated undrained (CU) tests and constant shear drained (CSD) tests on biocemented Ottawa sand are presented. In the CU tests, the biocemented sand had more dilative behaviour by showing a higher stress-strain curves and faster pore pressure reducing trends as compared with their untreated counterparts. In the CSD tests, the stress ratio q/p' at which biocemented sand became unstable was higher than that for untreated sands, implying that the biocementation will improve the stability of sand to water infiltration or liquefaction.

달걀껍질을 칼슘원으로 사용한 미생물 고결 모래의 공학적 특성 (Engineering Characteristics of Cemented Sand with Microorganism Using Eggshell as Calcium Source)

  • 최선규;박성식
    • 한국지반공학회논문집
    • /
    • 제32권5호
    • /
    • pp.5-13
    • /
    • 2016
  • 요소 분해 미생물을 이용하여 흙 입자 사이에 칼사이트를 석출시킬 때 칼슘원이 필요하며, 일반적으로 염화칼슘을 칼슘원으로 사용하고 있다. 염화칼슘은 도로, 지반 및 주변 식물에 부작용을 일으키므로 본 연구에서는 버려지는 달걀껍질을 사용한 칼슘원을 개발하고자 하였다. 미생물에 기존 칼슘원인 염화칼슘 또는 식초로 달걀껍질을 분해하여 얻은 새로운 칼슘원을 혼합하여 모래 입자 사이에 칼사이트를 생성시킨 다음, 고결모래의 칼사이트 생성량, 투수계수 및 일축압축강도를 비교 분석하였다. 공시체 제작은 느슨한 상태의 Ottawa모래로 직경 5cm, 높이 10cm 공시체를 만든 다음 Sporosarcina pasteurii 미생물을 포함한 요소와 두 종류의 칼슘원을 1일 1회씩 30일 동안 주입하여 제작하였다. 칼슘원으로 달걀껍질을 사용한 경우 칼사이트 생성량은 평균 7.2%로 염화칼슘을 사용한 경우보다 1.2배 높았다. 또한 달걀껍질을 사용하여 고결시킨 공시체의 투수계수는 평균 3.82E-5cm/s로 7.7배 정도 감소하였으며, 일축압축강도는 평균 387kPa로 염화칼슘을 사용한 경우보다 1.2배 높았다. 한편, 칼슘원에 관계없이 칼사이트 생성량이 증가할수록 강도는 증가하고 투수계수는 감소하는 경향을 보였다.