• Title/Summary/Keyword: Otology

Search Result 120, Processing Time 0.019 seconds

A Personal Sound Amplification Product Compared to a Basic Hearing Aid for Speech Intelligibility in Adults with Mild-to-Moderate Sensorineural Hearing Loss

  • Choi, Ji Eun;Kim, Jinryoul;Yoon, Sung Hoon;Hong, Sung Hwa;Moon, Il Joon
    • Journal of Audiology & Otology
    • /
    • v.24 no.2
    • /
    • pp.91-98
    • /
    • 2020
  • Background and Objectives: This study aimed to compare functional hearing with the use of a personal sound amplification product (PSAP) or a basic hearing aid (HA) among sensorineural hearing impaired listeners. Subjects and Methods: Nineteen participants with mild-to-moderate sensorineural hearing loss (SNHL) (26-55 dB HL; pure-tone average, 0.5-4 kHz) were prospectively included. No participants had prior experience with HAs or PSAPs. Audiograms, speech intelligibility in both quiet and noisy environments, speech quality, and preference were assessed in three different listening conditions: unaided, with the HA, and with the PSAP. Results: The use of PSAP was associated with significant improvement in pure-tone thresholds at 1, 2, and 4 kHz compared to the unaided condition (all p<0.01). In the quiet environment, speech intelligibility was significantly improved after wearing a PSAP compared to the unaided condition (p<0.001), and this improvement was better than the result obtained with the HA. The PSAP also demonstrated similar improvement in the most comfortable levels compared to those obtained with the HA (p<0.05). However, there was no significant improvement of speech intelligibility in a noisy environment when wearing the PSAP (p=0.160). There was no significant difference in the reported speech quality produced by either device or in participant preference for the PSAP or HA. Conclusions: The current result suggests that PSAPs provide considerable benefits to speech intelligibility in a quiet environment and can be a good alternative to compensate for mild-to-moderate SNHL.

Anatomical and Pathological Findings of Magnetic Resonance Imaging in Idiopathic Sudden Sensorineural Hearing Loss

  • Kim, Min Bum;Lim, Jihyun;Moon, Il Joon
    • Journal of Audiology & Otology
    • /
    • v.24 no.4
    • /
    • pp.198-203
    • /
    • 2020
  • Background and Objectives: We sought to evaluate the diagnostic and prognostic value of measurable parameters of internal auditory canal (IAC) magnetic resonance imaging (MRI) in patients with idiopathic sudden sensorineural hearing loss (ISSNHL). Subjects and Methods: We retrospectively reviewed the patients with ISSNHL who underwent IAC MRI from January 2008 to March 2019. Measurable parameters of IAC MRI, such as the diameter of the IAC, bony cochlear nerve canal, and cross-sectional area of the cochlear nerve, were measured by a single examiner. These parameters were then compared between the affected and healthy sides. Inner-ear abnormalities such as intralabyrinthine hemorrhage or labyrinthitis were also evaluated. The relationship between the surveyed parameters and the diagnosis of ISSNHL was assessed. Results: A total of 208 patients with ISSNHL were included. The measured parameters of IAC MRI were not different between the affected and healthy sides and were also not associated with the diagnosis of ISSNHL. However, inner-ear abnormalities of IAC MRI in ISSNHL displayed a significant association with worse hearing before and after treatment. An age that was older than 40 years also correlated with poorer outcomes. Further, inner-ear abnormalities were more frequently detected when IAC MRI was performed early after ISSNHL onset. Conclusions: Patients with ISSNHL and inner ear abnormalities such as intralabyrinthine hemorrhage or labyrinthitis identified via IAC MRI may experience poorer hearing outcomes. To detect such abnormal findings, it is recommended to perform IAC MRI early after the onset of ISSNHL.

Effect of Digital Noise Reduction of Hearing Aids on Music and Speech Perception

  • Kim, Hyo Jeong;Lee, Jae Hee;Shim, Hyun Joon
    • Journal of Audiology & Otology
    • /
    • v.24 no.4
    • /
    • pp.180-190
    • /
    • 2020
  • Background and Objectives: Although many studies have evaluated the effect of the digital noise reduction (DNR) algorithm of hearing aids (HAs) on speech recognition, there are few studies on the effect of DNR on music perception. Therefore, we aimed to evaluate the effect of DNR on music, in addition to speech perception, using objective and subjective measurements. Subjects and Methods: Sixteen HA users participated in this study (58.00±10.44 years; 3 males and 13 females). The objective assessment of speech and music perception was based on the Korean version of the Clinical Assessment of Music Perception test and word and sentence recognition scores. Meanwhile, for the subjective assessment, the quality rating of speech and music as well as self-reported HA benefits were evaluated. Results: There was no improvement conferred with DNR of HAs on the objective assessment tests of speech and music perception. The pitch discrimination at 262 Hz in the DNR-off condition was better than that in the unaided condition (p=0.024); however, the unaided condition and the DNR-on conditions did not differ. In the Korean music background questionnaire, responses regarding ease of communication were better in the DNR-on condition than in the DNR-off condition (p=0.029). Conclusions: Speech and music perception or sound quality did not improve with the activation of DNR. However, DNR positively influenced the listener's subjective listening comfort. The DNR-off condition in HAs may be beneficial for pitch discrimination at some frequencies.

Comparison of Autophagy mRNA Expression between Chronic Otitis Media With and Without Cholesteatoma

  • Jung, Junyang;Jung, Su Young;Kim, Myung Gu;Kim, Young Il;Kim, Sang Hoon;Yeo, Seung Geun
    • Journal of Audiology & Otology
    • /
    • v.24 no.4
    • /
    • pp.191-197
    • /
    • 2020
  • Background and Objectives: Autophagy is known to be associated with pathogen infection. However, the expression of autophagy-related proteins has not been studied in chronic otitis media without cholesteatoma (COM) or with cholesteatoma (CholeOM). This study aimed to determine whether there is a difference between COM and CholeOM in autophagy-related gene mRNA expression. Subjects and Methods: For 47 patients with chronic otitis media, the inflammatory tissues were classified into granulation tissue (COM) or cholesteatoma (CholeOM) according to biopsy results. Results: PI3K mRNA expression (COM vs. CholeOM, mean±SD, 0.009±0.010 vs. 0.003±0.004; p=0.004) was lower, whereas Beclin-1 mRNA expression (0.089±0.107 vs. 0.176±0.163; p=0.034) was higher in the CholeOM group. Expression of PI3K mRNA in the CholeOM group was lower than that in the COM subgroups with presence of bacteria (0.022±0.019 vs. 0.001±0.001; p=0.001), otorrhea (0.049±0.068 vs. 0.003±0.004; p=0.004), and hearing loss over 40 dB (0.083±0.130 vs. 0.003±0.004; p=0.005). Conclusions: The data suggested that different autophagy proteins play important roles in chronic otitis media according to the presence or absence of cholesteatoma.

The Impact of Optical Illusions on the Vestibular System

  • Ozturk, Seyma Tugba;Serbetcioglu, Mustafa Bulent;Ersin, Kerem;Yilmaz, Oguz
    • Journal of Audiology & Otology
    • /
    • v.25 no.3
    • /
    • pp.152-158
    • /
    • 2021
  • Background and Objectives: Balance control is maintained in stationary and dynamic conditions, with coordinated muscle responses generated by somatosensory, vestibular, and visual inputs. This study aimed to investigate how the vestibular system is affected in the presence of an optical illusion to better understand the interconnected pathways of the visual and vestibular systems. Subjects and Methods: The study involved 54 young adults (27 males and 27 females) aged 18-25 years. The recruited participants were subjected to the cervical vestibular evoked myogenic potentials (cVEMP) test and video head impulse test (vHIT). The cVEMP and vHIT tests were performed once each in the absence and presence of an optical illusion. In addition, after each test, whether the individuals felt balanced was determined using a questionnaire. Results: cVEMP results in the presence of the optical illusion showed shortened latencies and increased amplitudes for the left side in comparison to the results in the absence of the optical illusion (p≤0.05). When vHIT results were compared, it was seen that the right lateral and bilateral anterior canal gains were increased, almost to 1.0 (p<0.05). Conclusions: It is thought that when the visual-vestibular inputs are incompatible with each other, the sensory reweighting mechanism is activated, and this mechanism strengthens the more reliable (vestibular) inputs, while suppressing the less reliable (visual) inputs. As long as the incompatible condition persists, the sensory reweighting mechanism will continue to operate, thanks to the feedback loop from the efferent vestibular system.

Cortical Deafness Due to Ischaemic Strokes in Both Temporal Lobes

  • Lachowska, Magdalena;Pastuszka, Agnieszka;Sokolowski, Jacek;Szczudlik, Piotr;Niemczyk, Kazimierz
    • Journal of Audiology & Otology
    • /
    • v.25 no.3
    • /
    • pp.163-170
    • /
    • 2021
  • Cortical deafness is a clinical rarity whereby a patient is unresponsive to all types of sounds despite the preserved integrity of the peripheral hearing organs. In this study, we present a patient who suddenly lost his hearing following ischaemic infarcts in both temporal lobes with no other neurological deficits. The CT confirmed damage to the primary auditory cortex (Heschl's gyrus) of both hemispheres. Initially, the patient was unresponsive to all sounds, however, he regained some of the auditory abilities during 10 months follow up. Pure tone threshold improvement from complete deafness to the level of moderate hearing loss in the right ear and severe in the left was observed in pure tone audiometry. Otoacoustic emissions, auditory brainstem responses, and acoustic reflex findings showed normal results. The middle and late latency potential results confirmed objectively the improvement of the patient's hearing, however, after 10 months still, they were somewhat compromised on both sides. In speech audiometry, there was no comprehension of spoken words neither at 3 nor at 10 months. The absent mismatch negativity confirmed above mentioned comprehension deficit. The extensive auditory electrophysiological testing presented in this study contributes to the understanding of the neural and functional changes in cortical deafness. It presents the evolution of changes after ischaemic cerebrovascular event expressed as auditory evoked potentials starting from short through middle and long latency and ending with event-related potentials and supported by neuroimaging.

Clinical Features and Hearing Outcomes of Sudden Sensorineural Hearing Loss in Diabetic Patients

  • Ju, Yeo Rim;Park, Hyoung-sik;Lee, Min Young;Jung, Jae Yun;Choi, Ji Eun
    • Journal of Audiology & Otology
    • /
    • v.25 no.1
    • /
    • pp.27-35
    • /
    • 2021
  • Background and Objectives: This study aimed to evaluate the clinical features and the clinical factors associated with prognosis of sudden sensorineural hearing loss (SSNHL) in diabetic patients. Subjects and Methods: Forty-nine diabetic with unilateral SSNHL were retrospectively included. All patients received systemic high dose steroid therapy within one month after onset and had more than one month of follow-up audiogram. The basic characteristics of the patients, initial and follow-up audiograms, laboratory data, and methods of steroid treatment were collected. Results: Compared to reference values in healthy subjects, 79%, 55%, and 45% of the patients had higher values of mean neutrophil-lymphocyte ratio (NLR), platelet-lymphocyte ratio (PLR), and lymphocyte-monocyte ratio (LMR), respectively. Older patients had significantly less degree of hearing loss, but they also had significantly worse hearing thresholds in the unaffected ear. After steroid treatment, less than half patients (47%) showed hearing recovery. Simultaneous intratympanic dexamethasone (ITD) injections with systemic steroid did not confer an additional hearing gain or an earlier recovery rate in diabetic patients with SSNHL. In the multivariate analysis, initial hearing thresholds of affected ear and timing of steroid treatment were significantly associated with hearing prognosis in diabetic patients with SSNHL. Conclusions: Diabetic patients with SSNHL tended to have increased NLR, LMR, and PLR, which are reported to be associated with microvascular angiopathy. Simultaneous ITD injections to improve hearing recovery in diabetic patients with SSNHL seems unnecessary.

Effects of Caffeine on Auditory- and Vestibular-Evoked Potentials in Healthy Individuals: A Double-Blind Placebo-Controlled Study

  • Tavanai, Elham;Farahani, Saeid;Ghahraman, Mansoureh Adel;Soleimanian, Saleheh;Jalaie, Shohreh
    • Journal of Audiology & Otology
    • /
    • v.24 no.1
    • /
    • pp.10-16
    • /
    • 2020
  • Background and Objectives:The blockage of adenosine receptors by caffeine changes the levels of neurotransmitters. These receptors are present in all parts of the body, including the auditory and vestibular systems. This study aimed to evaluate the effect of caffeine on evoked potentials using auditory brainstem responses (ABRs) and cervical vestibular-evoked myogenic potentials (cVEMPs) in a double-blind placebo-controlled study. Subjects and Methods: Forty individuals (20 females and 20 males; aged 18-25 years) were randomly assigned to two groups: the test group (consuming 3 mg/kg pure caffeine powder with little sugar and dry milk in 100 mL of water), and the placebo group (consuming only sugar and dry milk in 100 mL water as placebo). The cVEMPs and ABRs were recorded before and after caffeine or placebo intake. Results: A significant difference was observed in the absolute latencies of I and III (p<0.010), and V (p<0.001) and in the inter-peak latencies of III-V and I-V (p<0.001) of ABRs wave. In contrast, no significant difference was found in cVEMP parameters (P13 and N23 latency, threshold, P13-N23 amplitude, and amplitude ratio). The mean amplitudes of P13-N23 showed an increase after caffeine ingestion. However, this was not significant compared with the placebo group (p>0.050). Conclusions: It seems that the extent of caffeine's effects varies for differently evoked potentials. Latency reduction in ABRs indicates that caffeine improves transmission in the central brain auditory pathways. However, different effects of caffeine on auditory- and vestibular-evoked potentials could be attributed to the differences in sensitivities of the ABR and cVEMP tests.

Gaps-In-Noise Test Performance in Children with Speech Sound Disorder and Cognitive Difficulty

  • Jung, Yu Kyung;Lee, Jae Hee
    • Journal of Audiology & Otology
    • /
    • v.24 no.3
    • /
    • pp.133-139
    • /
    • 2020
  • Background and Objectives: The Gaps-In-Noise (GIN) test is a clinically effective measure of the integrity of the central auditory nervous system. The GIN procedure can be applied to a pediatric population above 7 years of age. The present study conducted the GIN test to compare the abilities of auditory temporal resolution among typically developing children, children with speech sound disorder (SSD), and children with cognitive difficulty (CD). Subjects and Methods: Children aged 8 to 11 years-(total n=30) participated in this study. There were 10 children in each of the following three groups: typically developing children, children with SSD, and children with CD. The Urimal Test of Articulation and Phonology was conducted as a clinical assessment of the children's articulation and phonology. The Korean version of the Wechsler Intelligence Scale for Children-III (K-WISC-III) was administered as a screening test for general cognitive function. According to the procedure of Musiek, the pre-recorded stimuli of the GIN test were presented at 50 dB SL. The results were scored by the approximated threshold and the overall percent correct score (%). Results: All the typically developing children had normal auditory temporal resolution based on the clinical cutoff criteria of the GIN test. The children with SSD or CD had significantly reduced gap detection performance compared to age-matched typically developing children. The children's intelligence score measured by the K-WISC-III test explained 37% of the variance in the percent-correct score. Conclusions: Children with SSD or CD exhibited poorer ability to resolve rapid temporal acoustic cues over time compared to the age-matched typically developing children. The ability to detect a brief temporal gap embedded in a stimulus may be related to the general cognitive ability or phonological processing.

Changes of Temporal Processing and Hearing in Noise after Use of a Monoaural Hearing Aid in Patients with Sensorineural Hearing Loss: A Preliminary Study

  • Kim, Yehree;Yang, Chan Joo;Yoo, Myung Hoon;Song, Chan Il;Chung, Jong Woo
    • Journal of Audiology & Otology
    • /
    • v.25 no.3
    • /
    • pp.146-151
    • /
    • 2021
  • Background and Objectives: The relationship between hearing aid (HA) use and improvement in cognitive function is not fully known. This study aimed to determine whether HAs could recover temporal resolution or hearing in noise functions. Materials and Methods: We designed a prospective study with two groups: HA users and controls. Patients older than 45 years, with a pure tone average threshold of worse than 40 dB and a speech discrimination score better than 60% in both ears were eligible. Central auditory processing tests and hearing in noise tests (HINTs) were evaluated at the beginning of the study and 1, 3, 6, and 12 months after the use of a monaural HA in the HA group compared to the control group. The changes in the evaluation parameters were statistically analyzed using the linear mixed model. Results: A total of 26 participants (13 in the HA and 13 in the control group) were included in this study. The frequency (p<0.01) and duration test (p=0.02) scores showed significant improvements in the HA group after 1 year, while the HINT scores showed no significant change. Conclusions: After using an HA for one year, patients performed better on temporal resolution tests. No improvement was documented with regard to hearing in noise.