• Title/Summary/Keyword: Osteoporotic proximal humerus fractures

Search Result 5, Processing Time 0.02 seconds

Internal Fixation with a Locking T-Plate for Proximal Humeral Fractures in Patients Aged 65 Years and Older

  • Yum, Jae-Kwang;Seong, Min-Kyu;Hong, Chi-Woon
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.217-221
    • /
    • 2017
  • Background: The purpose of this study was to evaluate the clinical and radiographic outcomes of internal fixation with locking T-plates for osteoporotic fractures of the proximal humerus in patients aged 65 years and older. Methods: From January 2007 through to December 2015, we recruited 47 patients aged 65 years and older with osteoporotic fractures of the proximal humerus. All fractures had been treated using open reduction and internal fixation with a locking T-plate. We classified the fractures in accordance to the Neer classification system; At the final follow-up, the indicators of clinical outcome-the range of motion of the shoulder (flexion, internal rotation, and external rotation) and the presence of postoperative complications-and the indicators of radiographic outcome-the time-to-union and the neck-shaft angle of the proximal humerus-were evaluated. The Paavolainen method was used to grade the level of radiological outcome in the patients. Results: The mean flexion was $155.0^{\circ}$ (range, $90^{\circ}-180^{\circ}$), the mean internal rotation was T8 (range, T6-L2), and the mean external rotation was $66.8^{\circ}$ (range, $30^{\circ}-80^{\circ}$). Postoperative complications, such as plate impingement, screw loosening, and varus malunion were observed in five patient. We found that all patients achieved bone union, and the mean time-to-union was 13.5 weeks of the treatment. The mean neck-shaft angle was $131.4^{\circ}$ at the 6-month follow-up. According to the Paavolainen method, "good" and "fair" radiographic results each accounted for 38 and 9 of the total patients, respectively. Conclusions: We concluded that locking T-plate fixation leads to satisfactory clinical and radiological outcomes in elderly patients with proximal humeral fractures by providing a larger surface area of contact with the fracture and a more rigid fixation.

PHILOS plate fixation with polymethyl methacrylate cement augmentation of an osteoporotic proximal humerus fracture

  • Kim, Do-Young;Kim, Tae-Yeong;Hwang, Jung-Taek
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.3
    • /
    • pp.156-158
    • /
    • 2020
  • PHILOS plate fixation in osteoporotic proximal humerus fracture of old age is well-known for high complication rate, especially metal failure, providing various augmentation techniques, such as calcium phosphate cement, allogenous or autologous bone graft. We report a case of polymethyl methacrylate augmentation to provide appropriate reduction with a significant mechanical support. This can be a treatment option for displaced unstable osteoporotic proximal humerus fracture with marked bony defect.

Incidence and Mortality after Proximal Humerus Fractures Over 50 Years of Age in South Korea: National Claim Data from 2008 to 2012

  • Park, Chanmi;Jang, Sunmee;Lee, Areum;Kim, Ha Young;Lee, Yong Beom;Kim, Tae Young;Ha, Yong Chan
    • Journal of Bone Metabolism
    • /
    • v.22 no.1
    • /
    • pp.17-21
    • /
    • 2015
  • Background: There has been lack of epidemiology of proximal humerus fracture using nationwide database in Asia. The purpose of this study was to investigate the incidence of proximal humerus fracture and its mortality following proximal humerus fracture in Korean over 50 years of age. Methods: The Korean National Health Insurance data were evaluated to determine the incidence and mortality of proximal humerus fracture aged 50 years or older from 2008 through 2012. Results: Proximal humerus fracture increased by 40.5% over 5 year of study. The incidence of fracture increased from 104.7/100,000 in 2008 to 124.7/100,000 in 2012 in women and from 45.3/100,000 in 2008 to 52.0/100,000 in 2012 in men, respectively. One year mortality rate after proximal humerus fracture was 8.0% in 2008 and 7.0% in 2012. One year mortality rate were 10.8% for men and 7.0% for women in 2008 and 8.5% for men and 6.4% for women in 2012. Conclusions: Our study showed that the proximal humerus fracture in elderly was recently increasing and associated with high mortality in Korea. Considering proximal humerus fracture was associated with an increased risk of associated fractures and an increased mortality risk, public health strategy to prevent the proximal humerus fracture in elderly will be mandatory.

Operative Treatment with Intramedullary Fibular Strut Allograft for Osteoporotic Proximal Humerus Fracture

  • Chun, Yong-Min;Lee, Wonyong
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.2
    • /
    • pp.95-99
    • /
    • 2017
  • Background: The purpose of this study was to investigate the clinical and radiological outcomes of locking plate fixation with fibular strut allograft to manage unstable osteoporotic proximal humerus fractures. Methods: We retrospectively reviewed 15 patients who underwent open reduction and locking plate fixation with fibular strut allograft for osteoporotic proximal humerus fracture between July 2011 and June 2015. For functional evaluation, we evaluated visual analogue scale (VAS) pain score, American Shoulder and Elbow Surgeons (ASES) score, University of California Los Angeles (UCLA) shoulder score, and active range of motion. For radiological evaluation, shoulder true anteroposterior (AP) and AP in $20^{\circ}$ external rotation, as well as the axillary view were taken at two weeks, six weeks, three months, six months, and one year. And the neck-shaft angle was measured on the AP view in $20^{\circ}$ external rotation view. Results: At the one-year follow-up, mean VAS pain score and all shoulder scores, including ASES score and UCLA shoulder score, exhibited satisfactory clinical outcomes. All patients obtained bone union between three and six months post-procedure. Moreover, the mean immediate postoperative neck-shaft angle was $138^{\circ}{\pm}4^{\circ}$, and at one-year follow-up, the neck shaft angle was $137^{\circ}{\pm}5^{\circ}$. There was no significant difference between the preoperative and postoperative values (p=0.105). Conclusions: For the unstable two-part and three-part osteoporotic proximal humerus fractures with medial calcar comminution, the use of fibular strut allograft with locking plate fixation was effective in maintaining the initial status of reduction and exhibiting the satisfactory functional and radiological outcomes.