• Title/Summary/Keyword: Oscillometric

Search Result 49, Processing Time 0.026 seconds

A Study about Correlation between Hot Flush and Pulse Wave Velocity(PWV)/Ankle-Brachial Index(ABI) in the Climacteric Women (갱년기 여성의 안면홍조와 맥파 전달 속도(PWV) 및 상완 발목 지수(ABI)의 상관성에 관한 연구)

  • Kim, Eun-Gyung;Hwang, Deok-Sang;Cho, Jung-Hoon;Jang, Jun-Bock;Lee, Jin-Moo;Lee, Chang-Hoon;Lee, Kyung-Sub
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.23 no.1
    • /
    • pp.53-64
    • /
    • 2010
  • Purpose: This study was performed to observe the correlation between Hot flush and pulse wave velocity(PWV), ankle brachial index(ABI) in the Climacteric women. Methods: We studied 63 climacteric women visiting OO hospital from 8th January 2007 to 22nd April 2009. The subjects were categorized in two groups, the hot flush group(37) and normal group(26). For the study, the subjects were selected by excluding the patients who receive treatment affect hot flush or have disease affect arterial states. We assessed PWV and ABI of two groups by Oscillometric method using VS-1000(Form PWV/ABI; Fukuda Denshi, Co., Ltd., Japan). From these results, we studied the correlation between hot flush and PWV/ABI by Wilcoxon Mann Whitney Test. Results: 1. It is shown that hot flush group was no significant correlation with normal group. There is no significant factor among R-PWV, L-PWV, R-ABI, L-ABI. However, L-ABI have shown relatively higher correlation with comparison to the other factors.(p-value<0.05) 2. R-PWV, L-PWV significantly increased in menopause group than in premenopause group though there is no relation to the hot flush. (p-value<0.01) Conclusion: Though the results showed no correlations between Hot flush and PWV/ABI in the Climacteric women, L-ABI showed relatively higher correlation with hot flush than others. R-PWV, L-PWV showed significant correlation between premenopause and menopause.

Validation of the mobile wireless digital automatic blood pressure monitor using the cuff pressure oscillometric method, for clinical use and self-management, according to international protocols

  • Yoo, Sooyoung;Baek, Hyunyoung;Doh, Kibbeum;Jeong, Jiyeoun;Ahn, Soyeon;Oh, Il-Young;Kim, Kidong
    • Biomedical Engineering Letters
    • /
    • v.8 no.4
    • /
    • pp.399-404
    • /
    • 2018
  • The purpose of this study was to evaluate the accuracy of a mobile wireless digital automatic blood pressure monitor for clinical use and mobile health (mHealth). In this study, a manual sphygmomanometer and a digital blood pressure monitor were tested in 100 participants in a repetitive and sequential manner to measure blood pressure. The guidelines for measurement used the Korea Food & Drug Administration protocol, which reflects international standards, such as the American National Standard Institution/Association for the Advancement of Medical Instrumentation SP 10: 1992 and the British Hypertension Society protocol. Measurements were generally consistent across observers according to the measured mean ${\pm}SD$, which ranged in $0.1{\pm}2.6mmHg$ for systolic blood pressure (SBP) and $0.5{\pm}2.2mmHg$ for diastolic blood pressure (DBP). For the device and the observer, the difference in average blood pressure (mean${\pm}$SD) was $2.3{\pm}4.7mmHg$ for SBP and $2.0{\pm}4.2mmHg$ for DBP. The SBP and DBP measured in this study showed accurate measurements that satisfied all criteria, including an average difference that did not exceed 5 mmHg and a standard deviation that did not exceed 8 mmHg. The mobile wireless digital blood pressure monitor has the potential for clinical use and managing one's own health.

Development of An Actuator-Based Blood Pressure Simulator for Automatic Blood Pressure Monitor (자동혈압계 점검을 위한 액추에이터 기반의 혈압 시뮬레이터 개발)

  • Soo Hong Kim;Seung Jun Lee;Mun Hyeok Lim;Hye Min Park;Min Seok Gang;Gun Ho Kim;Kyoung Won Nam
    • Journal of Biomedical Engineering Research
    • /
    • v.45 no.1
    • /
    • pp.49-55
    • /
    • 2024
  • Accurate measurement of blood pressure is essential for classifying an individual's disease, identifying blood pressure-related risks, and managing health. Due to the environmental and health hazards of mercury sphygmomanometers, automatic sphygmomanometers using the oscillometric method are widely used in hospitals as well as in general homes, and have established themselves as a practical standard sphygmomanometer. In this study, we developed a blood pressure simulator using an actuator that provides simulated pressure to an automatic blood pressure cuff. The developed blood pressure simulator adopts an arm-shaped cylindrical shape similar to the situation in which a person measures blood pressure with an automatic blood pressure monitor, and implements a method of transmitting pressure to the cuff using a pressure plate. Accuracy was evaluated through the mean and standard deviation of the difference with the commercialized blood pressure simulator BP PUMP 2, and reproducibility was confirmed using two automatic blood pressure monitors. The developed blood pressure simulator enables automatic blood pressure monitoring in a simple manner and also meets the evaluation standards for accuracy and reproducibility. In the future, as a standardized blood pressure simulator, it is expected to be of great help in evaluating and verifying the performance of automatic blood pressure monitors by supplementing precise hardware and software and building a blood pressure database.

Replacing Mercury Sphygmomanometers With Mercury-Free Sphygmomanometers for the National Health Survey in Children: Direct Comparisons Applying Two Types of Mercury-Free Sphygmomanometer

  • Sung Hye Kim;Yu-Mi Kim;Seong Heon Kim;Jinho Shin;Eun Mi Lee
    • Korean Circulation Journal
    • /
    • v.54 no.5
    • /
    • pp.270-287
    • /
    • 2024
  • Background and Objectives: Blood pressure (BP) measurement using an auscultatory sphygmomanometer is recommended for diagnosing hypertension in children. As mercury sphygmomanometers (MSs) are banned owing to environmental concerns, it is crucial to determine the accuracy of mercury-free sphygmomanometers to replace them. We analyzed the accuracy of these devices to guide the National Survey selection. Methods: BP was measured thrice each with MS, auscultatory device (AD), and oscillometric device (OD) in 104 participants aged 10-18 using the National Survey data. The difference in BP was defined as the difference between MS and other devices. The BP differences, correlations, and influencing factors were analyzed. The frequencies of hypertension were also compared. Results: Systolic BP (SBP) and diastolic BP (DBP) differences between MS and AD were 0.88±3.36 mmHg and 0.63±3.95 mmHg, and those between MS and OD were 0.43±5.83 mmHg and 4.57±6.89 mmHg, respectively. The absolute error of <10 mmHg for DBP between MS and OD was 76%. The concordance correlation coefficient between MS and AD was 0.94 for SBP and 0.90 for DBP, and 0.81 and 0.67, respectively for MS and OD. Arm circumference negatively correlated with BP differences except for SBP between the MS and OD. The frequency of hypertension was not different between MS and AD but was underestimated by OD. Conclusions: AD correlated well with MS, while OD did not, especially for DBP. The superiority of AD over OD suggests AD as a possible alternative for MS in the National Survey.

Normative blood pressure references for Korean children and adolescents (한국 소아 청소년 정상 혈압 참고치)

  • Lee, Chong Guk;Moon, Jin Soo;Choi, Joong-Myung;Nam, Chung Mo;Lee, Soon Young;Oh, Kyungwon;Kim, Young Taek
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.1
    • /
    • pp.33-41
    • /
    • 2008
  • Purpose : It is now understood that blood pressure (BP) measurement in the routine pediatric examination is very important because of the relevance of childhood BP to pediatric health care and the development of adult essential hypertension. There hasn't been a reference table of BP for Korean children and adolescents up to now. This study was to make normative BP references and to provide criteria of hypertension for Korean children and adolescents. Methods : BP measurements were done on 57,433 Koean children and adolescents (male: 29,443, female: 27,990), aged 7 to 20 years, in 2005. Heights and weights were measured simultaneously. Oscillometric devices, Dinamap Procare 200 (GE Inc., Milwaukee, Wi, USA), were used for the measurements. BPs were measured 2 times and mean levels were gathered for the analysis. Outliers of 2,373 subjects with overweight per height, over +3SD, were excluded for the analysis. For the BP centiles adjusted by sex, age and height, fixed modified LMS method which was adopted from the mixed effect model of 2004 Task Force in NHLBI (USA) was used. Results : Normative BP tables for Korean children and adolescents adjusted for height percentiles (5th, 10th, 25th, 50th, 75th, 90th, 95th), gender (male, female) and age(7 to 18 years) were completed. Height centiles of Korean children and adolescents are available from Korean Center for Disease Control and Prevention homepage, http://www.cdc.go.kr/webcdc/. Criteria of hypertension (95th, 99th percentile) and normal range of BP (50th, 90th) adjusted for height percentiles, age and gender were made. Conclusion : This is the first study to make normative BP tables and define hypertension for the Korean children and adolescents. Reliability and accuracy of Dinamap Procare 200 oscillometer for BP measurements remains debatable.

Effects of Music on Dental Anxiety and Pain during Ultrasonic Teeth Scaling (치석제거술시 치통 및 불안에 대한 음악의 효과)

  • Kim, Hyo-Suk;Choi, Chung-Ho;Hwang, Kyu-Yoon;Lee, Sung-Soo
    • Journal of Korean society of Dental Hygiene
    • /
    • v.1 no.1
    • /
    • pp.63-76
    • /
    • 2001
  • This study was designed to evaluate the effects of music on dental pain and anxiety during ultrasonic scaling. One hundred and twenty five patients visited dental unit of Soonchunhyang University Chunan hospital for scaling were enrolled during August 1999 and February 2000. The patients were allocated randomly into two groups. music (n = 61) and control groups (n = 65). The music group patients listened to self-selected music using an earphone during scaling. Standardized questionnaire were used to assess the subjective denial pain and anxiety before and after scaling in both groups. In music group, more information on music effect was collected. To evaluate changes of physical signs by scaling, blood pressure and pulse were checked by a wrist check oscillometric. The results were as follows: 1. No significant difference in dental pain and anxiety between before and after scaling was observed in music group. However, the music group patients were satisfied with music because of reduction of pain(93.5%) and anxiety(93.4%), 96.7% of music subjects wanted to listen to music in next scaling. 2. While no significant difference in systolic blood pressure before scaling between music and control groups, systolic blood pressure of control group during scaling was significantly higher than that of music group(P<0.05). 3. In multiple logistic regression. the odds ratio(OR) of pain was decreased with age and female patients had higher OR (1.7, p>0.05). Patients with previous scaling experience complained of more dental pain during scaling than patients without experience. Music was not a significant predictor of denial pain during scaling, controlling for possible confounders. 4. While age. music. and scaling experience were not related to dental anxiety during scaling, sex and dental hygiene index were significant predictors of dental anxiety in multiple logistic regression. 5. Both during and after scaling. mean blood pressure of music patients were significantly lower than control patients after controlling for age, sex, and BMI. In conclusion, our data demonstrated that although listening to music did not disappear the dental pain and anxiety. but reduced the intensity of pain and anxiety during scaling. Furthermore, our data imply thai music has a effect of reduction of increasing blood pressure by scaling.

  • PDF

Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents

  • Lee, Chong-Guk;Park, Hyang-Mi;Shin, Hye-Jung;Moon, Jin-Soo;Hong, Young-Mi;Kim, Nam-Soo;Ha, Il-Soo;Chang, Myeong-Jin;Oh, Kyeong-Won
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.11
    • /
    • pp.463-469
    • /
    • 2011
  • Purpose: To validate the Dinamap ProCare 200 blood pressure (BP) monitor against a mercury sphygmomanometer in children 7 to 18 years old in accordance with the 2010 International Protocol of European Society of Hypertension (ESH-IP2) and the British Hypertension Society (BHS) protocol. Methods: Forty-five children were recruited for the study. A validation procedure was performed following the protocol based on the ESH-IP2 and BHS protocols for children and adolescents. Each subject underwent 7 sequential BP measurements alternatively with a mercury sphygmomanometer and the test device by trained nurses. The results were analyzed according to the validation criteria of ESH-IP2. Results: The mean (${\pm}SD$) difference in the absolute BP values between test device and mercury sphygmomanometer readings was $1.85{\pm}1.65$ mmHg for systolic BP (SBP) and $4.41{\pm}3.53$ mmHg for diastolic BP (DBP). These results fulfilled the Association for the Advancement of Medical Instrumentation criterion of a mean${\pm}$SD below $5{\pm}8$ mmHg for both SBP and DBP. The percentages of test device-observer mercury sphygmomanometer BP differences within 5, 10, and 15 mmHg were 96%, 100%, and 100% for SBP, and 69%, 92%, and 100% for DBP, respectively, in the part 1 analysis; both SBP and DBP passed the part 1 criteria. In the part 2 analysis, SBP passed the criteria but DBP failed. Conclusion: Although the Dinamap ProCare 200 BP monitor failed an adapted ESH-IP2, SBP passed. When comparing BP readings measured by oscillometers and mercury sphygmomanometers, one has to consider the differences between them, particularly in DBP, because DBP can be underestimated.

Angiotensinogen gene M235T polymorphism as a predictor of cardiovascular risk in hypertensive adolescents (고혈압 청소년의 심혈관계 위험요소로서 Angiotensinogen M235T 유전자 다형)

  • Gil, Joo Hyun;Lee, Jung Ah;Park, Eun Young;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.1
    • /
    • pp.36-43
    • /
    • 2009
  • urpose : The renin-angiotensin system (RAS) has been demonstrated to play a major role in regulating blood pressure. Therefore, components of the RAS are likely candidate genes that may predispose an individual to essential hypertension and cardiovascular complications. Among them, the M235T polymorphism of the angiotensinogen gene has been speculated to be associated with elevated circulating angiotensinogen concentrations and essential hypertension. This study aimed to analyze the angiotensinogen M235T polymorphism in hypertensive adolescents and investigate its relationship with cardiovascular risks. Methods : Forty Korean hypertensive adolescents (aged 16-17, systolic $BP{\geq}140 mmHg$ and/or diastolic $BP{\geq}90 mmHg$) and fifty seven normal adolescents were included. Obesity index (OI), body mass index (BMI) were calculated. BP was measured by oscillometric methods in resting state. Polymerase chain reaction (PCR) technique was performed on DNA from the hypertensives subjects to analyze the M235T polymorphism. Serum homocysteine, insulin, renin, aldosterone and angiotensin converting enzyme (ACE) were tested according to each genotype. The carotid intima-media thickness (IMT) and carotid artery diameter, Pulse wave velocity (PWV) and ankle-brachial index (ABI) were measured according to each genotype. Results : Genotype frequencies of T/T, M/T and M/M were 62.5%, 35.0%, 2.5%, respectively in hypertensive adolescents. The results were not significantly different compared to control group. Serum insulin, renin levels, BMI and OI were significantly higher in thoses with the M/M genotype as compared to those with the T/T of M/T genotype. Conclusion : This study showed that the M235T polymorphism was not associated with essential hypertension or any cardiovascular risks. Further clinical research is required to ascertain the relationship between this polymorphism and cardiovascular complications in Korean hypertensive adolescents.

Blood Pressure of Healthy Newborns in the First Week of Life (분당 차병원에서 출생한 신생아 혈압치 비교)

  • Lee Jung-Sun;Park Shin-I;Park Hye-Won;Kim Se-Hyun;Hah Tae-Sun;Lee Jun-Ho
    • Childhood Kidney Diseases
    • /
    • v.9 no.1
    • /
    • pp.8-14
    • /
    • 2005
  • Purpose : This study was peformed to study normative blood pressure data in full-term neonates that may be used to facilitate Identification of neonatal hypertension.Methods : 383 newborns born in our hospital from May 2003 to January 2004 were enrolled in this study Using an oscillometric device(BP-88 NEXT, COLIN Corp.), their blood pressures were measured more than one time within a week after birth. According to each clinical variable such as sex, delivery mode, birth weight, gestational age and presence of maternal disease or perinatal problems, we divided the population into groups and calculated the mean blood pressures of each group. We compared mean blood pressures between the divided groups according to each clinical variable statistically.Results : Mean systolic and diastolic blood pressure of the Population was 70.8$\pm$ 10.9 mmHg and 43.4 $\pm$ 8.0 mmHg, respectively. There was no satistically significant difference in blood pressure according to clinical variables. Mean systolic pressure showed positive correlation with birth weight and gestational age(r=0.1420, 0.03130).Conclusion : Our results are almost in agreement with Zubrow's data from 695 newborns in U.S.A, 1995. Our data may be helpful for early detection and management of neonatal hypertension, thereby maintaining renal function ,and preventing possible complications of renal disease.

  • PDF