• 제목/요약/키워드: Oscillometric

검색결과 47건 처리시간 0.027초

가정용 전자식 혈압계의 정확도에 대한 임상적 평가 (Clinical Evaluation of the Accuracy of Electronic Home Blood Pressure Measuring Devices)

  • 추진아
    • 기본간호학회지
    • /
    • 제9권1호
    • /
    • pp.101-112
    • /
    • 2002
  • Purpose: This study evaluated the accuracy of electronic devices compared with mercury sphygmomanometer. Of 132 outpatients with electronic devices. 77 who possessed oscillometric cuff devices participated in this study. Method: When the blood pressure was measured, all electronic devices were connected by means of a Y-connector to a mercury sphygmomanometer. Using the simultaneous same arm approach, each comparison was carried out three times at 2-minute intervals. Results: Compared with the mercury sphygmomanometer, the electronic devices underestimated systolic and diastolic blood pressure, respectively by $4.0{\pm}5.8mmHg$ and $2.5{\pm}67mmHg$, which satisfies the standard error range of the American Association for the Advancement of Medical Instrumentation. According to the British Hypertension Society criteria, these differences achieved C grade for both systolic and diastolic pressure. For the graphical analysis, the differences had a tendency to fulfill the permitted error limits in both diastolic and systolic blood pressure. Moreover, the purchase duration was not correlated with the accuracy of electronic devices. Conclusion: These results indicate that difference in blood pressure between electronic devices and mercury sphygmomanometer is within the standard error. Therefore, electronic blood pressure measuring devices may be useful for therapeutic self-management of hypertension.

  • PDF

대전지역 중학생의 혈압 분포와 비만지수 및 일부 환경인자와의 관계 (Blood Pressure Distribution of Adolescents in Taejon City and its Relationship with Obese Index and Several Environmental Factors)

  • 이정원;나효숙
    • 대한지역사회영양학회지
    • /
    • 제1권2호
    • /
    • pp.178-188
    • /
    • 1996
  • Blood pressure distribution of adolescents and its several related factors including obesity were investigated through blood pressure measuring by automated oscillometric method, anthropometry, and questionnaire. Subjects were 480 female and 480 male middle school students living in Taejon. Mean values of systolic(SBP)/diastolic(DNP) blood pressure of male and female students were 118.4$\pm$11.0/69.5$\pm$9.6 mmHg and 116.9$\pm$10.4/69.5$\pm$8.6 mmHg, respectively. Their blood pressures, particularly SBP, increased with age and showed higher value in the males than in the females. All frequency distributions of SBP and DBP, by sex and age, showed normal curves and their 50th, 90th, and 95th percentiles were presented. As obese index increased, both SBP and DBP were elevated and the prevalence of hypertension which was classified by Task Force Report(1987) increased, particularly in male students. Body weight and BMI were positively correlated with both SBP and DBP, and hight was also positively correlated with SBP or DBP. Our data inicated that blood pressure and hypertension prevalence of adolescents tended to increase and various internal and external environmental factors affected them. It was emphasized that blood pressure measurement should be done in every medical examination of adolescents and the nationwide Korean standard of blood pressure for adolescents have to be prepared. (Korean J Community Nutrition 1(2) : 178-188, 1996)

  • PDF

Blood Pressure Simulation using an Arterial Pressure-volume Model

  • Yoon, Sang-Hwa;Kim, Jae-Hyung;Ye, Soo-Young;Kim, Cheol-Han;Jeon, Gye-Rok
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권1호
    • /
    • pp.38-43
    • /
    • 2008
  • Using an arterial pressure-volume (APV) model, we performed an analysis of the conventional blood pressure estimation method using an oscillometric sphygmomanometer with computer simulation. Traditionally, the maximum amplitude algorithm (MAA) has been applied to the oscillation waveforms of the APV model to obtain the mean arterial pressure and the characteristic ratio. The estimation of mean arterial pressure and characteristic ratio was significantly affected by the shape of the blood pressure waveforms and the cutoff frequency of high-pass filter (HPF) circuitry. Experimental errors result from these effects when estimating blood pressure. To determine an algorithm independent of the influence of waveform shapes and parameters of HPF, the volume oscillation of the APV model and the phase shift of the oscillation with fast Fourier transform (FFT) were tested while increasing the cuff pressure from 1 mmHg to 200 mmHg (1 mmHg/s). The phase shift between ranges of volume oscillation was then only observed between the systolic and the diastolic blood pressures. The same results were obtained from simulations performed on two different arterial blood pressure waveforms and one hyperthermia waveform.

오실로메트릭 혈압 측정에서 커패시턴스 센서와 적응필터를 이용한 새로운 잡음제거방법에 관한 연구 (A New Method for Artifact Reduction Based on Capacitive Sensor and Adaptive Filter in Oscillometric Blood Pressure Measurement)

  • 최현석;박호동;이경중
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권3호
    • /
    • pp.239-248
    • /
    • 2008
  • In this study, a new method using a capacitive sensor and an adaptive filter was proposed to deal with artifacts contaminating an oscillation signal in oscilometric blood pressure measurement. The proposed method makes use of a variation of the capacitance between an electrode fixed to a cuff and an external object to detect artifacts caused by the external object bumping into the cuff. The proposed method utilizes the adaptive filter based on linear prediction to remove the detected artifacts. The conventional method using linear interpolation and the proposed method using the adaptive filter were applied to three types of the artifact-contaminated oscillation signals(no overlap, non-consecutive overlap, and consecutive overlap between artifacts and oscillations) to compare them in terms of the artifact reduction performance. The proposed method was more robust than the conventional method in the case of consecutive overlap between artifacts and oscillations. The proposed method could be useful for measuring blood pressure in such a noisy environment that the subject is being transported.

Simulation of the Blood Pressure Estimation Using the Artery Compliance Model and Pulsation Waveform Model

  • Jeon, Ahyoung;Ro, Junghoon;Kim, Jaehyung;Baik, Seongwan;Jeon, Gyerok
    • 센서학회지
    • /
    • 제22권1호
    • /
    • pp.38-43
    • /
    • 2013
  • In this study, the artery's compliance model and the pulsation waveform model was proposed to estimate blood pressure without applying HPF (High Pass Filter) on signal measured by the oscillometric method. The method proposed in the study considered two ways of estimating blood pressure. The first method of estimating blood pressure is by comparing and analyzing changes in pulsation waveform's dicrotic notch region during each cardiac period. The second method is by comparing and analyzing morphological changes in the pulsation waveform during each cardiac period, which occur in response to the change in pressure applied on the cuff. To implement these methods, we proposed the compliance model and the pulsation waveform model of the artery based on hemodynamic theory, and then conducted various simulations. The artery model presented in this study only took artery's compliance into account. Then, a pulsation waveform model was suggested, which uses characteristic changes in the pulsation waveform to estimate blood pressure. In addition, characteristic changes were observed in arterial volume by applying artery's pulsation waveform to the compliance model. The pulsation waveform model was suggested to estimate blood pressure using characteristic changes of the pulsation waveform in the arteries. This model was composed of the sum of sine waves and a Fourier's series in combination form up to 10th harmonics components of the sinusoidal waveform. Then characteristic of arterial volume change was observed by inputting pulsation waveform into the compliance model. The characteristic changes were also observed in the pulsation waveform by mapping the arterial volume change in accordance with applied cuff's pressure change to the pulsation waveform's change according to applied pressure changes by cuff. The systolic and diastolic blood pressures were estimated by applying positional change of pulsation waveform's dicrotic notch region.

Blood Pressure Simulator using An Optimal Controller with Disturbance Observer

  • Kim, Cheol-Han;Han, Gi-Bong;Lee, Hyun-Chul;Kim, Yun-Jin;Nam, Ki-Gon;SaGong, Geon;Lee, Young-Jin;Lee, Kwon-Soon;Jeon, Gye-Rok;Ye, Soo-Young
    • International Journal of Control, Automation, and Systems
    • /
    • 제5권6호
    • /
    • pp.643-651
    • /
    • 2007
  • The various blood pressure simulators have been proposed to evaluate and improve the performance of the automatic sphygmomanometer. These have some problems such as the deviation of the actual blood pressure waveform, limitation in the blood pressure condition of the simulator, or difficulty in displaying the blood flow. An improved simulator using disturbance observer is proposed to supplement the current problems of the blood pressure simulator. The proposed simulator has an artificial arm model capable of feeding appropriate fluids that can generate the blood pressure waveform to evaluate the automatic sphygmomanometer. A controller was designed and thereafter, simulation was performed to control the output signal with respect to the reference input in the fluid dynamic model using the proposed proportional control valve. To minimize the external fluctuation of pressure applied to the artificial arm, a disturbance observer was designed on the plant. A hybrid controller combined with a proportional controller and feed-forward controller was fabricated after applying a disturbance observer to the control plant. Comparison of the simulations between the conventional proportional controller and the proposed hybrid controller indicated that even though the former showed good control performance without disturbance, it was affected by the disturbance signal induced by the cuff. The latter exhibited an excellent performance under both situations.

A Comparative Study of Methods of Measurement of Peripheral Pulse Waveform

  • Kang, Hee-Jung;Lee, Yong-Heum;Kim, Kyung-Chul;Han, Chang-Ho
    • 대한한의학회지
    • /
    • 제30권3호
    • /
    • pp.98-105
    • /
    • 2009
  • Objective: Increased aortic and carotid arterial augmentation index (AI) is associated with the risk of cardiovascular disease. The most widely used approach for determining central arterial AI is by calculating the aortic pressure waveform from radial arterial waveforms using a transfer function. But how the change of waveform by applied pressure and the pattern of the change rely on subject's characteristics has not been recognized. In this study, we use a new method for measuring radial waveform and observe the change of waveform and the deviation of radial AI in the same position by applied pressure. Method: Forty-six non-patient volunteers (31 men and 15 women, age range 21-58 years) were enrolled for this study. Informed consent in a form approved by the institutional review board was obtained in all subjects. Blood pressure was measured on the left upper arm using an oscillometric method, radial pressure waves were recorded with the use of an improved automated tonometry device. DMP-3000(DAEYOMEDI Co., Ltd. Ansan, Korea) has robotics mechanism to scan and trace automatically. For each subject, we performed the procedure 5 times for each applied pressure level. We could thus obtain 5 different radial pulse waveforms for the same person's same position at different applied pressures. All these processes were repeated twice for test reproducibility. Result: Aortic AI, peripheral AI and radial AI were higher in women than in men (P<0.01), radial AI strongly correlated with aortic AI, and radial AI was consistently approximately 39% higher than aortic AI. Relationship between representative radial AI of DMP-3000 and peripheral AI of SphygmoCor had strongly correlation. And there were three patterns in change of pulse waveform. Conclusion: In this study, it is revealed the new device was sufficient to measure how radial AI and radial waveform from the same person at the same time change under applied pressure and it had inverse-proportion to applied pressure.

  • PDF

가압식 오실로메트릭 측정법에서 정확한 평균 동맥압 측정을 위한 노이즈 제거 알고리즘 (Noise Removal Algorithm for Accurate Mean Arterial Pressure Measurement in Pressurized Oscillometric Method)

  • 조인희;임정현;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2018년도 춘계학술대회
    • /
    • pp.184-187
    • /
    • 2018
  • 뇌경색의 예방 및 치료에 있어서 가장 중요한 요소는 대뇌 혈류량을 증가시키는 것이다. 대뇌 혈류를 증가시키는 방법으로는 기본적으로 약물에 의한 방법과 수술 또는 동맥 내에 의료 기구를 직접 삽입하는 침습적인 시술(NeuroFloTM) 등이 있다. 본 논문에서 제안하는 비 침습적인 대뇌 혈류 증가 장치는 합병증 유발 확률이 적고, 환자의 혈압 상태에 따라 치료 수준을 정할 수 있으므로 환자의 부담을 덜어줄 수 있다. 이러한 비 침습적인 대뇌 혈류 증가 장치 구현에 있어, 환자에게 알맞은 치료 수준을 제공하기 위한 정확한 평균 동맥압 값을 측정하는 것이 중요하다. 따라서 노이즈를 제거하기 위해 아날로그 필터 및 디지털 필터를 사용하였고, 피크 값 검출을 위한 알고리즘, 펌프제어 알고리즘 등을 사용하였다.

  • PDF

수은 혈압계와 DINAMAP 8100 자동 혈압계의 혈압측정치 비교연구 (Evluation of the DINAMAP 8100 Automated Blood Pressure monitor ; comparison with the Mercury Sphygmomanometer)

  • 김미연;최희강;김남진
    • 기본간호학회지
    • /
    • 제3권1호
    • /
    • pp.96-107
    • /
    • 1996
  • Automated blood pressure monitors have gained acceptance in many clinical settings with the increasing demand, the accurate BP measuring devices reguire the need for validation. We have evaluated the Dinamap 8100, an oscillometric automated blood pressure monitor, using the Mercury sphygmomanometer as a reference. Comparison of sphygmomanometers was conducted 60 patients (30-Normotensive group, 30-Hypertensive group at Seoul National University Hospital. Two trained observers took measure blood pressure(systolic/diastolic) at the same time using the Dinamap 8100 on one arm and the Mercury on the other. For each measurement, the device was randomly selected from a group of devices repetively used for the experiment. Mean readings for systolic pressure with the Dinamap 8100 in normotensive group were lower(mean difference ; 4.26mmHg) than the Mercury type. Mean readings for systolic pressure with the Dinamap 8100 in hypertensive group were lower(mean difference ; 9.05mmHg) than the Mercury type. Mean readings for diastolic pressure with the Dinamap 8100 in normotensive group were lower (mean difference ; 7.46mmHg) than the Mercury type. Mean readings for diastolic pressure with the Dinamap 8100 in hypertensive group were lower(mean difference ; 9.03mmHg) than the Mercury type. We have found that blood pressure readings with the Dinamap 8100 were lower than those with the Mercury type. we are using the Mercury type in clinics, although it has observer bias and terminal digit preference. But the Dinamap 8100 is readily portable, simple to use, and capable of preventing observer bias and terminal digit preference. The Dinamap 8100 is acceptable for blood pressure determination in subjects who are normotensive or hypertensive ones.

  • PDF

갱년기 여성의 안면홍조와 맥파 전달 속도(PWV) 및 상완 발목 지수(ABI)의 상관성에 관한 연구 (A Study about Correlation between Hot Flush and Pulse Wave Velocity(PWV)/Ankle-Brachial Index(ABI) in the Climacteric Women)

  • 김은경;황덕상;조정훈;장준복;이진무;이창훈;이경섭
    • 대한한방부인과학회지
    • /
    • 제23권1호
    • /
    • pp.53-64
    • /
    • 2010
  • Purpose: This study was performed to observe the correlation between Hot flush and pulse wave velocity(PWV), ankle brachial index(ABI) in the Climacteric women. Methods: We studied 63 climacteric women visiting OO hospital from 8th January 2007 to 22nd April 2009. The subjects were categorized in two groups, the hot flush group(37) and normal group(26). For the study, the subjects were selected by excluding the patients who receive treatment affect hot flush or have disease affect arterial states. We assessed PWV and ABI of two groups by Oscillometric method using VS-1000(Form PWV/ABI; Fukuda Denshi, Co., Ltd., Japan). From these results, we studied the correlation between hot flush and PWV/ABI by Wilcoxon Mann Whitney Test. Results: 1. It is shown that hot flush group was no significant correlation with normal group. There is no significant factor among R-PWV, L-PWV, R-ABI, L-ABI. However, L-ABI have shown relatively higher correlation with comparison to the other factors.(p-value<0.05) 2. R-PWV, L-PWV significantly increased in menopause group than in premenopause group though there is no relation to the hot flush. (p-value<0.01) Conclusion: Though the results showed no correlations between Hot flush and PWV/ABI in the Climacteric women, L-ABI showed relatively higher correlation with hot flush than others. R-PWV, L-PWV showed significant correlation between premenopause and menopause.