• Title/Summary/Keyword: Orthopedics

Search Result 644, Processing Time 0.019 seconds

The Computerized Measurement for the Radiological Severity of Hallux Valgus (무지 외반증의 중증도에 대한 전산화 영상 계측)

  • Kang, Chang-Nam;Choi, Kyung-Jin;Lee, Doo-Yeon;Kim, Sang-Duk;Sung, Il-Hoon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • Purpose: To study the reliability of intra- and interobserver reliability in angular measurement of hallux valgus deformity by assessing hallux valgus angle (HVA) and the 1st to 2nd intermetatarsal angle (1-2 IMA) through using computerized system. Materials and Methods: 20 cases of moderate to severe hallux valgus patients were included in this study. With the standing anteroposterior view of foot, the HVA and 1-2 IMA were calculated by computerized measurement system of Infinity cooperation, called ${\pi}$-view, with its software tools. Using the statistical software program, SPSS (version 12th), we interpreted the results which were measured by two independent observers. Results: In the intraobserver measurement, the HVA of observer A showed reliability ($32.5^{\circ}{\pm}6.9$ and $33.1^{\circ}{\pm}6.8$)(p<0.05). 1-2 IMA in observer A was not regarded as reliable ($16.9^{\circ}{\pm}2.8$ and $17.1^{\circ}{\pm}2.8$)(p>0.05). In the results of observer B, HVAs were measured as $35.7^{\circ}{\pm}7.6$ and $36.2^{\circ}{\pm}7.7$, and were not reliable (p>0.05). 1-2 IMA in observer B was not reliable as well ($17.0^{\circ}{\pm}0.8$ and $20.8^{\circ}{\pm}1.5$)(p>0.05). In the interobservers' measurements, the first and the second results of HVA were $3.2^{\circ}{\pm}3.6$ and $3.1^{\circ}{\pm}3.1$, reliable within the 95% confidence interval (p<0.05). 1-2 IMAs were $0.1^{\circ}{\pm}1.9$ and $3.73^{\circ}{\pm}1.3$, which were not reliable (p>0.05). Conclusion: In the angular measurement of the hallux valgus by computerized system, the HVA and 1-2 IMA showed less error range in the interobserver's results, compared with the previous studies about the manual measurement. However, our results failed to show the statistical reliability of intra- and interobserver's measuring. Therefore, even the computerized angular measurements in the severity of hallux valgus require development of the measuring methods and software tools.

  • PDF

The Indication of Ankle Lateral Ligament Reconstruction Using Tendon Graft in Chronic Ankle Instability (만성 족관절 불안정증에서 건이식을 이용한 외측 인대 재건술의 적응증)

  • Park, Jae Yong;Choi, Gi-Won;Cho, Jae-ho;Kang, Chan;Choi, Kyungjin;Chung, Jin-Wha;Kim, Hak Jun;Bae, Su-Young;Cha, Seung-Do;Kim, Ki Chun;Han, Seung Hwan;The Insurance Committee of Korean Foot and Ankle Society
    • Journal of Korean Foot and Ankle Society
    • /
    • v.20 no.1
    • /
    • pp.12-18
    • /
    • 2016
  • Purpose: The purpose of this study is to review the indications of ankle lateral complex reconstruction using tendon graft. Materials and Methods: We searched PubMed using the index, "ankle, instability, lateral ligament, reconstruction" from 1990 to present (September 30, 2015). We excluded 1) modified Brőstrom operation (MBO), 2) conventional tenodesis surgery, 3) review article, 4) technical note, and 5) articles written in another foreign language. We reviewed 24 papers through the publication events, operational method, the indications of surgery, and the specific features of the patient group. Results: There were the indications of 1) previous ligament surgery failure, 2) situation when ligament repair is impossible due to the ligament defect, 3) severe instability (preoperative talar tilt >$15^{\circ}$, anterior draw >10 mm or the difference of contralateral side talar tilt >$5^{\circ}$, anterior draw >3 mm), and 4) overweight (body mass index >$30kg/m^2$). Other considerations included 1) generalized joint laxity and 2) workers, highly-demanded or athlete highly-affected by instability. Conclusion: The ankle lateral complex reconstruction using tendon graft could be indicated in patients with the possibility of MBO failure with several considerations.

Usefulness of Ultrasonographic Follow Up Study After Repair of Peripheral Lateral Meniscal Tear (외측 반월상 연골 변연부 파열 봉합 후 초음파 추적 검사의 유용성)

  • Kim, Jung-Man;Im, Dong-Sun;Kim, Tae-Hyung;Shin, Eun-Su;Moon, Young-Suk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.1
    • /
    • pp.15-19
    • /
    • 2011
  • Purpose: The purpose of this study was to evaluate usefulness of ultrasonography for the follow up of the repair of peripheral lateral meniscal tear compared to MRI. Materials and Methods: Fourteen patients who underwent repair of peripheral lateral meniscus tear were followed for at least 1 year (1 to 2.5 years). Ten cases were male, four cases were women, and average age was 36.1 years (19~53 years). After surgery ultrasonography and physical were performed at 6 weeks, 3 months, 6 months and 1 year. Results: Three cases had joint line tenderness or swelling on physical examination until 3 months, but after then, it disappeared. There is no re-tear in ultrasonograhic examination. Conclusion: The ultrasonography was useful for the follow-up study of the peripheral lateral meniscus tear.

  • PDF

Significance of Ultrasonography in Diagnosis of Medial Meniscus Tear (내측 반월상 연골 파열의 진단에서 초음파의 의의)

  • Kim, Jung-Man;Im, Dong-Sun;Kim, Tae-Hyung;Kim, Jong-Ick;Lee, Kyu-Jo
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Purpose: To evaluate the usefulness of ultrasonography in diagnosis of the medial meniscus tear as a screening tool before performing magnetic resonance imaging. Materials and Methods: From April 2009 to September 2010, magnetic resonance imaging (MRI) was taken in 147 knees out of 341 knees examined with ultrasonography (US) under the suspicion of medial meniscus tear. The sonographic findings were 16 without abnormality, 12 inhomogeneity, 4 cluster, 60 cleavage and 55 more than 5mm medial extrusion of medial meniscus. In Statistical analysis, sensitivity and specificity, positive predictive value and negative predictive values were calculated. Results: The MRI showed abnormality in 104 knees. Sensitivity and specificity of ultrasonography for MRI was 94.2% and 23.3%, respectively. Positive predictive value was 74.8%, negative predictive value was 62.5%. The positive predictive value of ultrasonography were 58.3% in heterogeneity, 100% in showing cluster, 75% in visible cleft and 80% in medial extrusion. Conclusion: The US is a useful tool in prediction of medial meniscus tear before confirming it in high-cost MRI.

  • PDF

Platelet Rich Plasma Injection: Evidence Based Analysis (혈소판 풍부 혈장 주사 요법: 근거 중심의 분석)

  • Oh, Joo Han;Chung, Seok Won
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.2
    • /
    • pp.111-122
    • /
    • 2011
  • Platelet rich plasma (PRP) has been widely used nowadays for several common orthopaedic-related sports medicine conditions with the theoretical basis that PRP supplies numerous autologous growth factors from concentrated platelets needed to promote the healing process of injured tissue. Even though there are many basic sciences, animal studies and some clinical studies regarding PRP injections for musculoskeletal injuries which suggested good results, it is difficult to compare these various studies due to marked methodological differences such as PRP preparation method, the timing, volume and number of injection, and the outcome measurement tool. In addition, many studies have no control groups or a limited sample size, and there are few prospective randomized controlled trials assessing the efficacy of PRP injections. Therefore, well designed high-quality randomized studies are required to confirm the preliminary results until now and provide scientific evidence to support its use, and the paucity of scientific clinical evidence suggest that the administration of PRP on humans for musculoskeletal injuries should be performed with caution.

  • PDF

Prolotherapy in Orthopedic Field (정형외과 영역에서의 증식치료)

  • Shon, Min Soo;Yoo, Jae Chul
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.2
    • /
    • pp.101-110
    • /
    • 2011
  • To describe the background, mechanism, clinical results and complications of prolotheapy based on the literature review. Prolotherapy is a minimally invasive injection-based treatment of chronic musculoskeletal pain, including ligament and joint laxity. The mechanism of this injection-based technique is to initiate a local inflammatory response with resultant tissue healing. The used proliferants are classified by bio-mechanism to act in three different ways as osmotic, irritants, and chemotatics. The most commonly used proliferant is hyperosmolar (10~25%) dextrose to act by osmotic rupture of cells. High resolution ultrasound imaging of musculoskeletal structure provide a more accurate diagnosis. Also ultrasound-guided intervention provides a more high efficacy and low rate of complications. The most common complication is local pain at the injected site, that is self-limited and good responsive to anti-inflammatory agents. Other complications are rare. It is reported that prolotherapy appears safe when performed by an experienced clinician. Prolotherapy has grown in popularity and has received significant recent attention. However there are limited evidence-based data supporting the indication and efficacy of prolotherapy in the treatment of chronic musculoskeletal pain or soft tissue injuries. Future studies are necessary to determine whether prolotherapy can play an independent and definitive role in a treatment for chronic musculoskeletal pain.

  • PDF

Clinical Efficacy of the Ultrasonography in the Diagnosis of the Palpable Soft Tissue Masses (촉지되는 연부조직 종괴의 진단에서 초음파 검사의 유용성)

  • Park, Tae Soo;Kim, Hong Sik;Kim, Sungjun;Ryu, Jeong Ah
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.2
    • /
    • pp.59-65
    • /
    • 2011
  • Purpose: To determine the clinical efficacy of the ultrasonography (US) for the diagnosis of the soft tissue masses comparing to the clinical diagnosis through the physical examination. Materials and Methods: 83 consecutive patients with palpable soft tissue masses were presented retrospectively. On the basis of the pathological diagnosis after the operation, the diagnostic accuracies were evaluated the cases diagnosed by history taking and physical examination, and the cases diagnosed by US before the operation. Results: The diagnostic accuracy of the cases using US was higher(86.7%) than that of the cases using physical examination and history taking. The accuracy of US of the epidermal inclusion cyst was 71.4%, ganglion cyst 85.7%, lipoma 88.6%, respectively. Accurate diagnosis were made 54 cases with 65.1% sensitivity in the cases diagnosed by history taking and physical examination. In this case, its accuracy of the ganglion cyst was 56.0%, and the lipoma was 67.9%. Conclusion: US is a useful diagnostic tool for the diagnosis of the palpable soft tissue masses before the operation.

  • PDF

Use of platelet-rich plasma and modified nanofat grafting in infected ulcers: Technical refinements to improve regenerative and antimicrobial potential

  • Segreto, Francesco;Marangi, Giovanni Francesco;Nobile, Carolina;Alessandri-Bonetti, Mario;Gregorj, Chiara;Cerbone, Vincenzo;Gratteri, Marco;Caldaria, Erika;Tirindelli, Maria Cristina;Persichetti, Paolo
    • Archives of Plastic Surgery
    • /
    • v.47 no.3
    • /
    • pp.217-222
    • /
    • 2020
  • Background Surgical reconstruction of chronic wounds is often infeasible due to infection, comorbidities, or poor viability of local tissues. The aim of this study was to describe the authors' technique for improving the regenerative and antimicrobial potential of a combination of modified nanofat and platelet-rich plasma (PRP) in nonhealing infected wounds. Methods Fourteen patients met the inclusion criteria. Fat tissue was harvested from the lower abdomen following infiltration of a solution of 1,000 mL of NaCl solution, 225 mg of ropivacaine, and 1 mg of epinephrine. Aspiration was performed using a 3-mm cannula with 1-mm holes. The obtained solution was decanted and mechanically emulsified, but was not filtered. Non-activated leukocyte-rich PRP (naLR-PRP) was added to the solution before injection. Patients underwent three sessions of injection of 8-mL naLR-PRP performed at 2-week intervals. Results Thirteen of 14 patients completed the follow-up. Complete healing was achieved in seven patients (53.8%). Four patients (30.8%) showed improvement, with a mean ulcer width reduction of 57.5%±13.8%. Clinical improvements in perilesional skin quality were reported in all patients, with reduced erythema, increased thickness, and increased pliability. An overall wound depth reduction of 76.6%±40.8% was found. Pain was fully alleviated in all patients who underwent re-epithelization. A mean pain reduction of 42%±33.3% (as indicated by visual analog scale score) was found in non-re-epithelized patients at a 3-month follow-up. Conclusions The discussed technique facilitated improvement of both the regenerative and the antimicrobial potential of fat grafting. It proved effective in surgically-untreatable infected chronic wounds unresponsive to conventional therapies.

Development of 3D Printing System for Human Bone Model Manufacturing Using Medical Images (의료 영상을 이용한 인체 골 모형 제작의 3차원 프린팅 시스템 개발)

  • Oh, Wang-Kyun
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.433-441
    • /
    • 2017
  • The 3D printing selective laser sintering (SLS) and stereo lithography apparatus (SLA) method used for bone model production has good precision and resolution, but the printers are expensive and need professional knowledge for operation. The program that converts computed tomography digital imaging and communications in medicine (DICOM) file into STL (stereolithography) file is also expensive so requesting 3D printing companies takes a lot of time and cost, which is why they are not generally utilized in surgery. To produce bone models of fractured patients, the use of 3D imaging conversion program and 3D printing system should be convenient, and the cost of device and operation should be low. Besides, they should be able to produce big size bone models for application to surgery. Therefore, by using an fused deposition modeling (FDM) method 3D printer that uses thermoplastic materials such as DICOM Viewer OsiriX and plastic wires, this study developed 3D printing system for Fracture surgery Patients customized bone model production for many clinics to use for surgery of fracture patients by universalizing with no limit in printing sizes and low maintenance and production cost. It is expected to be widely applied to the overall areas of orthopedics' education, research and clinic. It is also expected to be conveniently used in not only university hospitals but also regular general hospitals.

Development of a Quality of Life Scale For Children on Chronic Peritoneal Dialysis (만성 복막투석 아동용 삶의 질 척도 개발)

  • Shin, Min-Sup;Cho, Soo-Churl;Jang, Jae-Yeon;Cheong, Hae-Il;Choi, Yong;Ha, Il-Soo
    • Childhood Kidney Diseases
    • /
    • v.12 no.2
    • /
    • pp.202-212
    • /
    • 2008
  • Purpose : The aim of this study was to develop a quality of life scale for children on chronic peritoneal dialysis(QOL-CPD). Methods : Thirty children on chronic PD at Seoul National University Children's Hospital participated. A healthy control group included 47 elementary school children. Other patients groups are 32 children from the department of pediatric orthopedics and 28 children from the department of child psychiatry. The age range of all children was 7 to 16 years. Preliminary items of the QOL-CPD were developed and administered along with the Korean version of the Children's Depression Inventory(CDI) to all children. Results : The final QOL-CPD was constructed by excluding those items with a factor loading of less than .20, and the principal axis factor analysis was performed again. The QOLCPD demonstrated a good internal consistency with a value of .87. The dialysis and childpsychiatric groups showed significantly lower QOL scores compared to the healthy control group. In addition, the dialysis and child-psychiatric groups showed greater difficulties on physical and academic functions. For the CDI, the PD group showed a mild level of depression. Conclusion : The results of this study demonstrate the clinical utility of a newly developed self-report QOL scale specific for children on chronic PD.