• Title/Summary/Keyword: Orthopedics

Search Result 644, Processing Time 0.023 seconds

Microstructure and Corrosion Resistance of Ti-15Sn-4Nb Alloy with Hf Adding Element (Hf가 첨가된 생체용 Ti-15Sn-4Nb 합금의 미세조직 및 내식성)

  • Lee, Doh-Jae;Lee, Kyung-Ku;Cho, Kyu-Zong;Yoon, Taek-Rim;Park, Hyo-Byung
    • Journal of Technologic Dentistry
    • /
    • v.23 no.1
    • /
    • pp.55-64
    • /
    • 2001
  • This study is focusing on the improvement of problems of Ti-6Al-4V alloy. A new Ti based alloy, Ti-15Sn-4Nb, have designed to examine any possibility of improving the mechanical properties and biocompatibility. Specimens of Ti alloys were melted in vacuum arc furnace and homogenized at $100^{\circ}C$ for 24h. All specimens were solution treated at $812^{\circ}C$ and aged at $500^{\circ}C$ for 10h. The corrosion resistance of Ti alloys was evaluated by potentiodynamic polarization test and immersion test inl%Lactic acid solutions. Ti-15Sn-4Nb system alloys showed Widmanstatten microstructure after solution treatment which is typical microstructure of ${\alpha}+{\beta}$ type Ti alloys. Analysing the corrosion resistance of Ti alloys, it was concluded that the passive films of Ti-15Sn-4Nb system alloys are more stable than that of Ti-6Al-4V alloys. Also, the corrosion resistance of Ti-15Sn-4Nb system alloys was improved with adding elements, Hf. It was analysed that the passive film of the Ti-15Sn-4Nb alloy which was formed in air atmosphere was consisted of TiO2, SnO and NbO through X-ray photoelectron spectroscopy(XPS) analysis.

  • PDF

Analysis of Nursing Phenomena and Nursing Action using ICNP - Focused on orthopedic patients nursing records - (ICNP를 이용한 간호현상, 간호활동 분석 -정형외과 간호기록 중심으로-)

  • Ryu, Sun-Hee;Hong, Hae-Sook;Park, Sang-Youn;Lee, Eun-Joo
    • Journal of Home Health Care Nursing
    • /
    • v.11 no.1
    • /
    • pp.14-22
    • /
    • 2004
  • The purpose of this study was to establish the basic-data set for the electronic nursing records system by analysis of nursing phenomenas and nursing actions described in nursing records of orthopedic patients using the ICNP. Nursing notes for 1.421 days of 97 orthopedics patients who were discharged from a tertiary teaching hospital in Daegu were used. Narrative data from the nursing notes were collected. decomposed. and cross mapped with the concepts of the ICNP beta version. In total 11.442 statements were found in the process of decomposing the narrative data into single statement. These statements consist of 3.970(34.70%) nursing phenomena statements. 6.996(61.14%) nursing action statements, and 476(4.16%) other statements. Finally 312 unique statements were collected by integrating same or similar statements. These statements consist of 120 (38.46%) nursing phenomena statements. 154 (49.36%) nursing action statements. and 38 (12.18%) other statements. When this result was cross mapped with ICNP beta version. 77.0% of nursing statements were completely expressed. 17.0% of them were partially expressed. and 0.3% of them were not able to expressed at all. The findings of this study showed the usability of ICNP as terminology of electronic nursing records system. And the result of this study can be utilized for an ICNP-based electronic nursing records system and can help clinical nurses to spend more time on direct nursing.

  • PDF

Algorithm development of automatic symptom degree for Patient with Hallux Valgus (무지외반증 환자의 증상정도의 자동분류 알고리즘 개발)

  • Han, Hyun-Ji;Lee, Sang-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.2
    • /
    • pp.96-102
    • /
    • 2011
  • In this study, we performed algorithm development of automatic symptom degree for patient with hallux valgus one of the representative foot disease of morden. And this study proposes an efficient automated technique that is different from the original analog diagnosis for treatment and surgery of hallux valgus using digital image process. And we used X-Ray images of both a normal and a patient with hallux valgus in the procedure. First, we marked the standard angle on the X-Ray image of normal through Overlap & Add technique. Then we created a standard image through thinning filter and roberts filter(edge detection algorithm). Second, we used sobel filter of edge detection algorithm on the X-Ray image of patient. Moreover, we went another overlap & add technique procedure with both normal and patient image that we made. With the output, we projected the display detection image onto the screen. Finally, with the display detection image, we could measure and project the diagnosis angle of hallux valgus. And this confirms that this method is much more practical and applicable for another orthopedics disease than the prior one.

Comparison of Upper and Lower Trapezius Activity During Shoulder Elevation and Depression for Acute and Chronic Whiplash-associated Disorder Patients (급성과 만성 편타성-관련 손상 환자의 상지 거상과 하강 동작시 상승모근과 하승모근의 근활성도 비교)

  • Kim, Sang-Su;Kim, Suhn-Yeop
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.16 no.1
    • /
    • pp.26-36
    • /
    • 2010
  • Purpose: The study compared the muscle activity and ratio of upper trapezius (UT) to lower trapezius (LT) activity between acute and chronic whiplash-associated disorder (WAD) patients. Methods: Twelve healthy (male: 7), 14 acute WAD (male: 7), and 11 chronic WAD (male: 3) volunteers participated in this study. Electromyography using a surface EMG recorded the activity of the upper trapezius and lower trapezius of both shoulders (dominant and non-dominant) during $120^{\circ}$ elevation when standing and shoulder depression when sitting. The testing order was selected randomly. Subjects were asked to maintain each experimental position for 5 seconds at end range. EMG activity was normalized using the maximal voluntary isometric contraction (MVIC) elicited using a manual muscle-testing technique. One-way repeated measures analysis of variance (ANOVA) was used to compare the average root mean square (RMS) value of EMG activity for each condition. Results: The EMG activity of the dominant UT for chronic WAD subjects was significantly higher than for acute WAD subjects during $120^{\circ}$ elevation (p<.05). The EMG activity of the dominant LT for acute WAD subjects was significantly lower than for the control group (p<.05) during $120^{\circ}$ elevation. The EMG activity of the dominant LT for WAD patients was significantly lower than for the control group during shoulder depression (p<.05), and the chronic WAD patients scored significantly the lowest (p<.01). The dominant UT/LT for chronic WAD patients was significantly higher than the ratio for acute WAD subjects during shoulder depression (p<.05); this result was higher than for the control group (p<.01). The non-dominant UT/LT (ratio) for chronic WAD patients was significantly higher than the ratio for acute WAD subjects during shoulder depression (p<.05). Conclusion: The UT for chronic WAD subjects was hyperactive when compared to the acute WAD subjects, and the was hypoactive for both acute and chronic patients, therefore intra-trapezius imbalance was more prevalent during shoulder depression.

  • PDF

Influence of Walking With High-Heeled Shoes on the Knee Joint of Obese Women (하이힐 보행이 비만여성의 슬관절에 미치는 영향)

  • Chang, Yun-Hee;Lee, Wan-Hee
    • Physical Therapy Korea
    • /
    • v.14 no.3
    • /
    • pp.23-31
    • /
    • 2007
  • The purpose of this study was to determine the influence of high-heeled shoes on walking of obese women as it was already proven an extrinsic factor of knee osteoarthritis in women with normal weight. In this study the aimed therefore in particular was to utilize high-heeled shoes in proving it's causal influence on knee osteoarthritis by measuring the angle and torque of the knee joint. Fifteen obese women (BMI>25 $kg/m^2$) were measured in their twenties. Each angle and torque of their knee joints during walking on 6.5 cm high-heeled shoes and with a bare feet, were compared with each other and analyzed with a 3D motion analysis system. There was no significant difference in walking speed, cadence and stride length between the two conditions. However, there was a significant increase in a double limb support time and the stance phase when walking on high-heeled shoes as when walking with bare feet. The peak knee flexion angle and peak knee varus torque was higher when walking on high-heeled shoes than with bare feet. On the contrary, the peak knee flexion angle in the swing phase was not statistically different. The prolongation of peak knee varus torque was also proven. There was a significant increase in peak knee varus torque in the initial and last stance phases during walking on high-heeled shoes as compared to walking on bare feet. Through the above results, it was proven that when obese women walked on high-heeled shoes, rather than with bare feet, peak knee flexor and varus torque increased along with the changes of the in knee joint angle. Therefore, the influence of high-heeled shoes might be a significant intrinsic factor in knee osteoarthritis of obese women.

  • PDF

The effects of cryopreservation on human dental pulp-derived mesenchymal stem cells

  • Tomlin, Allison;Sanders, Michael B;Kingsley, Karl
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.3 no.2
    • /
    • pp.105-114
    • /
    • 2016
  • The purpose of this study is to evaluate the effects of cryopreservation on dental pulp-derived stem cells (DPSC) viability over a period of three years. Dental pulp-derived stem cells were isolated and cultured from thirty-one healthy teeth. DPSC isolates were assessed for doubling-time and baseline viability prior to cryopreservation and were assessed again at three time points; one week (T1), 18 months (T2), and 36 months (T3). DPSC can be grouped based on their observed doubling times; slow (sDT), intermediate (iDT), and rapid (rDT). Viability results demonstrated all three types of DPSC isolates (sDT, iDT and rDT) exhibit time-dependent reductions in viability following cryopreservation, with the greatest reduction observed among sDT-DPSCs and the smallest observed among the rDT-DPSC isolates. Cryopreserved DPSCs demonstrate time-dependent reductions in cellular viability. Although reductions in viability were smallest at the initial time point (T1) and greatest at the final time point (T3), these changes were markedly different among DPSC isolates with similar doubling times (DTs). Furthermore, the analysis of various DPSC biomarkers - including both intracellular and cell surface markers, revealed differential mRNA expression. More specifically, the relative high expression of Sox-2 was only found only among the rDT isolates, which was associated with the smallest reduction in viability over time. The expression of Oct4 and NANOG were also higher among rDT isolates, however, expression was comparatively lower among the sDT isolates that had the highest reduction in cellular viability over the course of this study. These data may suggest that some biomarkers, including Sox-2, Oct4 and NANOG may have some potential for use as biomarkers that may be associated with either higher or lower cellular viability over long-term storage applications although more research will be needed to confirm these findings.

Perioperative Pain Management Using Regional Nerve Blockades in Shoulder Surgery: Ultrasound-Guided Intervention (견관절 수술 시 국소신경 차단술을 이용한 통증 관리 - 초음파 유도하 중재술 -)

  • Oh, Joo Han;Lee, Ye Hyun;Park, Hae Bong
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.1
    • /
    • pp.67-75
    • /
    • 2014
  • There are several kinds of regional nerve blockades, such as interscalene brachial plexus block, C5 root block, suprascapular nerve block, and axillary nerve block, which can be applied for anesthesia and postoperative pain control after shoulder surgeries. These regional nerve blockades have shown good results, but high failure rate and serious complications, such as phrenic nerve palsy, pneumothorax, and nerve injury, still remain. Ultrasound-guided intervention can increase the success rate of nerve blockades and reduce complications. We described the method of ultrasound-guided intervention for the regional nerve blockades around shoulder.

  • PDF

Ultrasound-guided Intervention in Cervical Spine (경추부 초음파 유도하 중재술)

  • Moon, Sang Ho
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.1
    • /
    • pp.49-66
    • /
    • 2014
  • Traditionally, cervical interventions have been performed under fluoroscopy. But radiation exposure is the major concern when obtaining fluoroscopic images and even under real-time fluoroscopy with contrast media or CT guidance, some cases of serious spinal cord injuries, cerebellar and brain stem infarction have been reported by unintentional intra-arterial injections especially during the transforaminal root blocks. Recently, the use of ultrasound-guided cervical interventions have increased. Ultrasound offers visualization of soft tissues including major neurovascular structures and also allows to observe the spread of injectant materials around the target structure. Ultrasound is radiation free, easy to use and the image can be performed continuously while the injectant is visualized in real-time, increasing the precision of injection. Importantly, ultrasound allows visualization of major nerves and vessels and thus leads to improve safety of cervical interventions by decreasing the incidence of injury or injection into nearby vasculature. We therefore reviewed to investigate the feasibility of performing cervical interventions under real-time ultrasound guidance.

  • PDF

Comparison of the Quality of Clavicle Fracture Three-dimensional Model Printing by Open Source and Commercial use Digital Imaging and Communications in Medicine Stereolithography File Conversion Program (공개용과 상업용 DICOM STL 파일변환 프로그램으로 출력한 삼차원 프린팅 쇄골 골절 모델의 품질비교)

  • Oh, Wang-Kyun;Kim, Hyeong-Gyun
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.61-66
    • /
    • 2018
  • The recent 3D printing technology is used in various medical, manufacturing, and education fields and is more efficient in terms of production process, time, and cost than existing production. Especially in fracture surgery, interest and research have been focused on improving accuracy, shortening of operation time and recovery time, and reducing reoperation. However, because of the financial and technical problems of the 3D printer and the file conversion program, the 3D printing is made directly at the hospital, and it is not generally used for diagnosis of fracture and surgical research. In this study, to solve those problems, clavicle CT imaging was switched into Osirix Open Source DICOM Viewer, Stereolithography file conversion programs and commercial Terarecon 3D DICOM Viewer, file conversion programs, and then clavicle fracture model was directly made through 3D printer of fused filament fabrication wire additive processing method, and then the accuracy of the shape was compared and analyzed. Clavicle fracture models printed in two methods were blind-tested on clinicians of general hospitals' orthopedics and radiologic technicians with over 10 years of experiences, and then their analysis opinions of resolution reviews were analyzed. The result showed no difference. The 3D printing model with open source DICOM STL file conversion program used was applicable to clinical, so it is considered useful in precision diagnosis of fracture and operation plans.

Initial experience with intra-articular 188Re-tin colloid as a "radiation synovectomy" agent in various joints

  • Shinto, Ajit S;Indira, VU;Kamaleshwaran, KK;Banka, Vinay Kumar;Aswathy, KK;Thirumalaisamy, SG;Rajamani, V;Mallia, Madhav;Banerjee, Sharmila
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.2
    • /
    • pp.109-117
    • /
    • 2015
  • Radiation synovectomy has been proposed as a promising palliative therapy for recurrent joint effusions for the last two or three decades. Ionizing radiations emitted by intrarticularly administered radiolabelled colloids. The aim of this study was to assess the effectiveness of radiation synovectomy (RSV) using $^{188}Re$-tin colloid in the treatment of recurrent joint effusions and chronic synovitis of knee joints. Three phase bone scan was acquired for the concerned joint prior to radiosynovectomy. $^{188}Re$-tin colloid was prepared as per the reported protocol. 9 patients, diagnosed with rheumatoid arthritis and suffering from chronic resistant synovitis of the knee, ankle or elbow joints were administered the radiopharmaceuticals, checked for radiochemical purity >95% by intraarticular route. A whole body scan was acquired 2 h post-radiosynovectomy. In all the 9 treatments, no leakage to non-target organs was visible in the whole body scan. Static scans of the joint revealed complete retention of $^{188}Re$-tin colloid in the joints post administration of the agent. Clinically all patients exhibited a complete or partial response. RSV with $^{188}Re$-tin colloid was safe and effective in patients with chronic synovitis of rheumatoid origin.