• 제목/요약/키워드: Orthopedic implants

검색결과 83건 처리시간 0.024초

Metastasis of renal cell carcinoma around suture anchor implants

  • Baek, Samuel;Shin, Myung Ho;Kim, Tae Min;Oh, Kyung-Soo;Lee, Dong Ryun;Chung, Seok Won
    • Clinics in Shoulder and Elbow
    • /
    • 제24권2호
    • /
    • pp.110-113
    • /
    • 2021
  • We present an unusual case of bone metastases from renal cell carcinoma around orthopedic implants in a 78-year-old female with osteolytic, expansile, highly vascularized, malignant infiltration around suture anchors in the proximal humerus. The patient had undergone arthroscopic rotator cuff repair using suture anchor implants 6 years previously. After diagnosis of bone metastasis, she was successfully treated with metastasectomy and internal fixation using a plate and screws, with cement augmentation. This report is the first to document metastases around a suture anchor in a bone and suggests the vulnerability of suture anchor implants to tumor metastasis.

골유착 이전에 악정형력이 임프란트 주위조직에 미치는 영향 (THE EFFECT OF DENIAL ORTHOPEDIC FORCE TO IMPLANTS ON BONE TISSUE BEFORE COMPLETE OSSEOINTEGRATION)

  • 김영호;이철원
    • 대한치과교정학회지
    • /
    • 제28권3호
    • /
    • pp.453-459
    • /
    • 1998
  • 저자들은 임프란트 매식 후 골유착을 위한 초기 치유기간 이전에 악정형력이 임프란트 주위 조직에 미치는 영향을 관찰하기 위하여 가토 12마리의 양측 대퇴골에 임프란트를 식립하고 2주, 4주 그리고 6주후에 각각 300g의 악정형력을 Ni-Ti close coil spring을 이용하여 매식된 임프란트에 4주동안 가하고 관찰한 후 다음과 같은 결론을 얻었다. 1. 모든 실험군의 임프란트는 4주간의 악정형력 적용후에도 안정된 견고성을 유지하였다. 2. 2주 실험군에서 대조군에 비해 임프란트와 골조직 사이의 섬유조직 증식이 많이 관찰 되었으나 특이할만한 염증소견은 관찰되지 않았다. 3. 4주 실험군, 대조군에서는 2주 실험군, 대조군과 각각 비교하였을 때 보다 많은 양의 골재생이 관찰 되었으며 실험군과 대조군 모두에서 임프란트와 골조직 사이의 섬유조직은 관찰하기 힘들었다. 4. 6주에서는 실험군과 대조군 사이에 뚜렷한 차이가 발견되지 않았다. 이상의 결과로 보아 임프란트 주위의 골조직 재생이 충분하지 않아도 골의 양과 질이 우수해 임프란트 식립시 견고한 초기고정을 얻을 수 있다면 골유착이 완성되는 초기 치유기간 이전에도 치과교정적 고정원으로 사용가능할 것으로 사료된다.

  • PDF

The impact of modern airport security protocols on patients with total shoulder replacements

  • Michael D. Scheidt;Neal Sethi;Matthew Ballard;Michael Wesolowski;Dane Salazar;Nickolas Garbis
    • Clinics in Shoulder and Elbow
    • /
    • 제26권4호
    • /
    • pp.416-422
    • /
    • 2023
  • Background: Advancements in airport screening measures in response to 9/11 have resulted in increased false alarm rates for patients with orthopedic and metal implants. With the implementation of millimeter-wave scanning technology, it is important to assess the changes in airport screening experiences of patients who underwent total shoulder arthroplasty (TSA). Methods: Here, 197 patients with prior anatomic and reverse TSA completed between 2013 and 2020 responded to a questionnaire regarding their experiences with airport travel screening after their operation. Of these patients, 86 (44%) stated that they had traveled by plane, while 111 (56%) had not. The questionnaire addressed several measures including the number of domestic and international flights following the operation, number of false alarm screenings by the millimeter-wave scanner, patient body habitus, and presence of additional metal implants. Results: A total of 53 patients (62%) responded "yes" to false screening alarms due to shoulder arthroplasty. The odds of a false screening alarm for patients with other metal implants was 5.87 times that of a false screening alarm for patients with no other metal implants (P<0.1). Of a reported 662 flights, 303 (45.8%) resulted in false screening alarms. Greater body mass index was not significantly lower in patients who experienced false screening alarms (P=0.30). Conclusions: Patients with anatomic and reverse TSA trigger false alarms with millimeter-wave scanners during airport screening at rates consistent with prior reports following 9/11. Patient education on the possibility of false alarms during airport screening is important until improvements in implant identification are made. Level of evidence: IV.

Pyrocarbon hemiarthroplasty and the shoulder: biomechanical and clinical results of an emerging treatment option

  • Mohamad Y. Fares;Jaspal Singh;Peter Boufadel;Matthew R. Cohn;Joseph A. Abboud
    • Clinics in Shoulder and Elbow
    • /
    • 제27권1호
    • /
    • pp.117-125
    • /
    • 2024
  • While shoulder hemiarthroplasty is still used to treat young patients with shoulder pathology, the use of this procedure has substantially declined in recent years due to its significant complication profile. Glenoid wear with arthrosis is one of the major postoperative complications following shoulder hemiarthroplasty, and efforts to prevent this complication led many scientists to explore alternative weight-bearing surfaces on arthroplasty implants to decrease joint wear and improve patient outcomes. Pyrolytic carbon, or pyrocarbon, is a material that has better biocompatibility, survivorship, strength, and wear resistance compared to the materials used in traditional shoulder hemiarthroplasty. Pyrocarbon implants have been used in orthopedics for over 50 years; recently, their utility in shoulder hemiarthroplasty has garnered much interest. The purpose behind the use of pyrocarbon in shoulder hemiarthroplasty is to decrease the risk of progressive glenoid wear, especially in young active patients in whom joint preservation is important. Promising survivorship and outcomes have been demonstrated by recent studies, including limited glenoid wear following pyrocarbon hemiarthroplasty. Nevertheless, these clinical studies have been limited to relatively small case series with limited long-term follow-up. Accordingly, additional research and comparative studies need to be conducted in order to properly assess the therapeutic efficacy and value of pyrocarbon hemiarthroplasty.

Silicone radial head prostheses revisited: do they have a role in today's practice? A systematic review of literature on clinical outcomes

  • Erik M van Bussel;Anneluuk L. Lindenhovius;Bertram The;Denise Eygendaal
    • Clinics in Shoulder and Elbow
    • /
    • 제26권3호
    • /
    • pp.312-322
    • /
    • 2023
  • Background: Silicone radial head prostheses (SRHP) are considered obsolete due to reports of frequent failure and destructive silicone-induced synovitis. Considering the good outcomes of modern non-radial silicone joint implants, the extent of scientific evidence for this negative view is unclear. The aim of this research was to systematically analyze the clinical evidence on complications and outcomes of SRHP and how SRHP compare to both non-SRHP and silicone prostheses of other joints. Methods: A systematic literature review was conducted through the Cochrane, PubMed, and Embase databases. Results: Eight cohort studies were included, consisting of 142 patients and follow-up periods ranging from 23 months to 8 years. Average patient satisfaction was 86%, range of 71%-100%, and 58 complications were seen, but no cases of synovitis. These outcomes were in line with non-SRHP. Four case series with 11 cases of synovitis were found, all due to implant fractures years to decades after implantation. Six systematic reviews of currently used non-radial silicone joint implants showed excellent outcomes with low complication rates. Conclusions: Since SRHP have satisfactory clinical results and an acceptable complication rate when selecting a patient group in suitable condition for surgical indications, it is considered that SRHP can still be chosen as a potential surgical treatment method in current clinical practice.

Treatment of instability with scapular notching and glenoid component loosing by partial mixed different implant revision

  • Chung, Young Woo;Shin, Woo Jin;An, Ki-Yong
    • Clinics in Shoulder and Elbow
    • /
    • 제23권4호
    • /
    • pp.190-193
    • /
    • 2020
  • In general, reverse shoulder arthroplasty revision is performed using the same implant for both the humerus and glenoid components. However, the authors of the present case used different implants from what was used previously for treating instability with scapular notching and glenoid aseptic loosening and report the case.

소결방법에 따른 다공성 티타늄 임플란트의 기계적 특성 (Mechanical property of porous Ti implants by sintering method)

  • 김영훈
    • 대한치과기공학회지
    • /
    • 제34권3호
    • /
    • pp.221-226
    • /
    • 2012
  • Purpose: This study was performed to compare mechanical properties for sintering methods of porous Ti implants. Methods: The specimens of Ti implant were fabricated by several sintering methods. One of them is spark plasma sintering(SPS). Another is electro discharge singering(EDS) and the other is high vacuum sintering(HVS). Mechanical properties of porous Ti implants were evaluated by universal testing machine(UTM) and their fracture surface was examined under a sanning electron microscope(SEM). Results: The tensile strength was in a range of 71 to 230 MPa, and Young's modulus was in a range of 11 to 21 Gpa. It matched with range of cortical bone. Conclusion: Mechanical properties of porous Ti implants were similar to human bone. It was shown that sintering methods of spherical powders can efficiently produce porous Ti implants with various porosities. Porous metals will be commonly used in orthopedic and dental application despite of initial focus has been on bioceramics.

다공성 티타늄 임플란트의 생리활성물질 담지특성에 관한 연구 (A study of loading property of the bioactive materials in porous Ti implants)

  • 김영훈
    • 대한치과기공학회지
    • /
    • 제35권4호
    • /
    • pp.281-286
    • /
    • 2013
  • Purpose: Surface modification is important techniques in modern dental and orthopedic implants. This study was performed to try embedding of bioactive materials in porous Ti implants. Methods: Porous Ti implant samples were fabricated by sintering of spherical Ti powders in a high vacuum furnace. It's diameter and height were 4mm and 20mm. Embedding process was used to suction and vacuum chamber. Loading properties of porous Ti implants were evaluated by scanning electron microscope(SEM), confocal laser scanning microscope(CLSM), and UV-Vis-NIR spectrophotometer. Results: Internal pore structure was formed fully open pore. Average pore size and porosity were $10.253{\mu}m$ and 17.506%. Conclusion: Porous Ti implant was fabricated successfully by sintering method. Particles are necking strongly each other and others portions were vacancy. This porous structure can be embedded to bioactive materials. Therefore bioactive materials will be able to embedding to porous Ti implants. Bioactive materials embedding in the porous Ti implant will induced new bone faster.