• Title/Summary/Keyword: Orthopedic implants

Search Result 78, Processing Time 0.028 seconds

Metastasis of renal cell carcinoma around suture anchor implants

  • Baek, Samuel;Shin, Myung Ho;Kim, Tae Min;Oh, Kyung-Soo;Lee, Dong Ryun;Chung, Seok Won
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.2
    • /
    • pp.110-113
    • /
    • 2021
  • We present an unusual case of bone metastases from renal cell carcinoma around orthopedic implants in a 78-year-old female with osteolytic, expansile, highly vascularized, malignant infiltration around suture anchors in the proximal humerus. The patient had undergone arthroscopic rotator cuff repair using suture anchor implants 6 years previously. After diagnosis of bone metastasis, she was successfully treated with metastasectomy and internal fixation using a plate and screws, with cement augmentation. This report is the first to document metastases around a suture anchor in a bone and suggests the vulnerability of suture anchor implants to tumor metastasis.

THE EFFECT OF DENIAL ORTHOPEDIC FORCE TO IMPLANTS ON BONE TISSUE BEFORE COMPLETE OSSEOINTEGRATION (골유착 이전에 악정형력이 임프란트 주위조직에 미치는 영향)

  • Kim, Young-Ho;Lee, Cheol Won
    • The korean journal of orthodontics
    • /
    • v.28 no.3 s.68
    • /
    • pp.453-459
    • /
    • 1998
  • The dental implants for edentulous Patients have been used for more than 20 years. After the introduction of osseointegration by $Br{\aa}nemark$, the commercially pure titanium implants were accepted by most practitioners. Recently dental implants are used for orthodontic anchorages as well as prosthetic abutment. Many researchers have reported implants as a good orthodontic anchorage through basic research and clinical evaluation. But previous researches were done after the healing time for osseointegration of inserted implants. If dental implants are to be used for prosthetic abutment the healing time for osseointegration is necessary, but orthodontic forces to implants are different from bite force regarding its amount of force, duration and direction. The authors evaluated the effect of orthopedic force to implants on bone tissue before osseointegration. 48 implants were placed at 12 rabbits. 2 implants into left side and 2 implants into right side were inserted along the long axis of femur respectively 2 weeks (2 weeks group), 4 weeks (4 weeks group) and 6 weeks (6 weeks group) after implants placement, 300g force had been applied to the implants at left side femur by Ni-Ti close coil spring for 4 weeks (experimental group) and no force applied to implants at right side femur (control group). After the force application for 4weeks, rabbits were sacrificed and microscopic evaluation was done by hematoxylin-eosin stain and Masson trichrome stain. The result3 were followed. 1. All implants in experimental group remained rigid after the force application for 4 weeks. 2. More fibrous tissue between bone and implants were noticed at 2 weeks experimental group than 2 weeks control group 3. More bone remodeling was noticed at 4weeks group than 2 weeks group and it was difficult to find out fibrous tissue between bone and implants at both experimental and control group of 4 weeks group. 4. It was hard to distinguish experimental group from control group at 6 weeks group. Therefore if initial stability can be obtained on implant insertion, it can be possible to use implants as a orthodontic anchorage before the healing time for osseointegration.

  • PDF

The impact of modern airport security protocols on patients with total shoulder replacements

  • Michael D. Scheidt;Neal Sethi;Matthew Ballard;Michael Wesolowski;Dane Salazar;Nickolas Garbis
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.4
    • /
    • pp.416-422
    • /
    • 2023
  • Background: Advancements in airport screening measures in response to 9/11 have resulted in increased false alarm rates for patients with orthopedic and metal implants. With the implementation of millimeter-wave scanning technology, it is important to assess the changes in airport screening experiences of patients who underwent total shoulder arthroplasty (TSA). Methods: Here, 197 patients with prior anatomic and reverse TSA completed between 2013 and 2020 responded to a questionnaire regarding their experiences with airport travel screening after their operation. Of these patients, 86 (44%) stated that they had traveled by plane, while 111 (56%) had not. The questionnaire addressed several measures including the number of domestic and international flights following the operation, number of false alarm screenings by the millimeter-wave scanner, patient body habitus, and presence of additional metal implants. Results: A total of 53 patients (62%) responded "yes" to false screening alarms due to shoulder arthroplasty. The odds of a false screening alarm for patients with other metal implants was 5.87 times that of a false screening alarm for patients with no other metal implants (P<0.1). Of a reported 662 flights, 303 (45.8%) resulted in false screening alarms. Greater body mass index was not significantly lower in patients who experienced false screening alarms (P=0.30). Conclusions: Patients with anatomic and reverse TSA trigger false alarms with millimeter-wave scanners during airport screening at rates consistent with prior reports following 9/11. Patient education on the possibility of false alarms during airport screening is important until improvements in implant identification are made. Level of evidence: IV.

Pyrocarbon hemiarthroplasty and the shoulder: biomechanical and clinical results of an emerging treatment option

  • Mohamad Y. Fares;Jaspal Singh;Peter Boufadel;Matthew R. Cohn;Joseph A. Abboud
    • Clinics in Shoulder and Elbow
    • /
    • v.27 no.1
    • /
    • pp.117-125
    • /
    • 2024
  • While shoulder hemiarthroplasty is still used to treat young patients with shoulder pathology, the use of this procedure has substantially declined in recent years due to its significant complication profile. Glenoid wear with arthrosis is one of the major postoperative complications following shoulder hemiarthroplasty, and efforts to prevent this complication led many scientists to explore alternative weight-bearing surfaces on arthroplasty implants to decrease joint wear and improve patient outcomes. Pyrolytic carbon, or pyrocarbon, is a material that has better biocompatibility, survivorship, strength, and wear resistance compared to the materials used in traditional shoulder hemiarthroplasty. Pyrocarbon implants have been used in orthopedics for over 50 years; recently, their utility in shoulder hemiarthroplasty has garnered much interest. The purpose behind the use of pyrocarbon in shoulder hemiarthroplasty is to decrease the risk of progressive glenoid wear, especially in young active patients in whom joint preservation is important. Promising survivorship and outcomes have been demonstrated by recent studies, including limited glenoid wear following pyrocarbon hemiarthroplasty. Nevertheless, these clinical studies have been limited to relatively small case series with limited long-term follow-up. Accordingly, additional research and comparative studies need to be conducted in order to properly assess the therapeutic efficacy and value of pyrocarbon hemiarthroplasty.

Silicone radial head prostheses revisited: do they have a role in today's practice? A systematic review of literature on clinical outcomes

  • Erik M van Bussel;Anneluuk L. Lindenhovius;Bertram The;Denise Eygendaal
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.3
    • /
    • pp.312-322
    • /
    • 2023
  • Background: Silicone radial head prostheses (SRHP) are considered obsolete due to reports of frequent failure and destructive silicone-induced synovitis. Considering the good outcomes of modern non-radial silicone joint implants, the extent of scientific evidence for this negative view is unclear. The aim of this research was to systematically analyze the clinical evidence on complications and outcomes of SRHP and how SRHP compare to both non-SRHP and silicone prostheses of other joints. Methods: A systematic literature review was conducted through the Cochrane, PubMed, and Embase databases. Results: Eight cohort studies were included, consisting of 142 patients and follow-up periods ranging from 23 months to 8 years. Average patient satisfaction was 86%, range of 71%-100%, and 58 complications were seen, but no cases of synovitis. These outcomes were in line with non-SRHP. Four case series with 11 cases of synovitis were found, all due to implant fractures years to decades after implantation. Six systematic reviews of currently used non-radial silicone joint implants showed excellent outcomes with low complication rates. Conclusions: Since SRHP have satisfactory clinical results and an acceptable complication rate when selecting a patient group in suitable condition for surgical indications, it is considered that SRHP can still be chosen as a potential surgical treatment method in current clinical practice.

Treatment of instability with scapular notching and glenoid component loosing by partial mixed different implant revision

  • Chung, Young Woo;Shin, Woo Jin;An, Ki-Yong
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.4
    • /
    • pp.190-193
    • /
    • 2020
  • In general, reverse shoulder arthroplasty revision is performed using the same implant for both the humerus and glenoid components. However, the authors of the present case used different implants from what was used previously for treating instability with scapular notching and glenoid aseptic loosening and report the case.

Mechanical property of porous Ti implants by sintering method (소결방법에 따른 다공성 티타늄 임플란트의 기계적 특성)

  • Kim, Yung-Hoon
    • Journal of Technologic Dentistry
    • /
    • v.34 no.3
    • /
    • pp.221-226
    • /
    • 2012
  • Purpose: This study was performed to compare mechanical properties for sintering methods of porous Ti implants. Methods: The specimens of Ti implant were fabricated by several sintering methods. One of them is spark plasma sintering(SPS). Another is electro discharge singering(EDS) and the other is high vacuum sintering(HVS). Mechanical properties of porous Ti implants were evaluated by universal testing machine(UTM) and their fracture surface was examined under a sanning electron microscope(SEM). Results: The tensile strength was in a range of 71 to 230 MPa, and Young's modulus was in a range of 11 to 21 Gpa. It matched with range of cortical bone. Conclusion: Mechanical properties of porous Ti implants were similar to human bone. It was shown that sintering methods of spherical powders can efficiently produce porous Ti implants with various porosities. Porous metals will be commonly used in orthopedic and dental application despite of initial focus has been on bioceramics.

A study of loading property of the bioactive materials in porous Ti implants (다공성 티타늄 임플란트의 생리활성물질 담지특성에 관한 연구)

  • Kim, Yung-Hoon
    • Journal of Technologic Dentistry
    • /
    • v.35 no.4
    • /
    • pp.281-286
    • /
    • 2013
  • Purpose: Surface modification is important techniques in modern dental and orthopedic implants. This study was performed to try embedding of bioactive materials in porous Ti implants. Methods: Porous Ti implant samples were fabricated by sintering of spherical Ti powders in a high vacuum furnace. It's diameter and height were 4mm and 20mm. Embedding process was used to suction and vacuum chamber. Loading properties of porous Ti implants were evaluated by scanning electron microscope(SEM), confocal laser scanning microscope(CLSM), and UV-Vis-NIR spectrophotometer. Results: Internal pore structure was formed fully open pore. Average pore size and porosity were $10.253{\mu}m$ and 17.506%. Conclusion: Porous Ti implant was fabricated successfully by sintering method. Particles are necking strongly each other and others portions were vacancy. This porous structure can be embedded to bioactive materials. Therefore bioactive materials will be able to embedding to porous Ti implants. Bioactive materials embedding in the porous Ti implant will induced new bone faster.