• Title/Summary/Keyword: Orthodontic wire

Search Result 143, Processing Time 0.021 seconds

A COMPARATIVE STUDY OF FRICTIONAL RESISTANCES BETWEEN ORTHODONTIC BRACKETS AND ARCH WIRE DURING SLIDING MOVEMENT OF TEETH (치아의 활주 이동시 교정용 brackets와 arch wire사이에서 발생하는 마찰 저항력에 관한 비교 연구)

  • Min, Jung-Mi;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.18 no.1 s.25
    • /
    • pp.155-163
    • /
    • 1988
  • The purpose of this study was to evaluate and compare frictional forces generated between orthodontic brackets and arch wires. Independent variables were chosen for study: arch wire size and shape, arch wire material, bracket width, and second-order angulation between bracket and arch wire. Kinetic frictional forces of stainless steel (0.014', 0.016', 0.018', 0.016' ${\times}$ 0.022', 0.018' ${\times}$ 0.022'), $\beta-titanium$ (0.016' ${\times}}$ 0.022') arch wires were measured on wide and junior edgewise twin brackets (0.018' ${\times}$ 0.022' slot). Instron was used to pull arch wires while $0^{\circ},\;3^{\circ},\;6^{\circ},\;or\;9^{\circ}$ angulation between and wire and bracket was given. The results were as follows: 1. The frictional force of $\beta-titanium$ wire was larger than that of stainless steel wire. 2. The frictional force was generally increased as the size of wire is increased. 3. The frictional force of rectangular wire was larger than that of round wire. 4. As second order angulation was increased, the frictional force was also increased. 5. The frictional force was larger on a wide bracket than on a junior bracket.

  • PDF

Study on the Retraction of Anterior Teeth in the Lingual Orthodontics with the Three-Dimensional Finite Element Method (유한 요소법을 이용한 설측 치아교정시 전치부 후방 견인에 관한 연구)

  • Song, Jung-Han;Hug, Hoon;Park, Hyun-Sang
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.198-203
    • /
    • 2004
  • In these days, the orthodontic surgery including lingual orthodontics has attracted a person' attention due to its functional and esthetic appreciation. The delivery of the optimal orthodontic treatment is greatly influenced by clinician' ability to predict and control the tooth movement by applying force system to dentition. The skeletal anchorage system with the miniscrew has been used recently in the lingual orthodontics to assist the anchorage control. Precise understanding of the force system produced from the various orthodontic appliances is necessary. However, the qualitative and quantitative effect of the miniscrew has not been identified well. In this paper, three dimensional finite element analysis is introduced on the lingual orthodontics to investigate the effect of anterior retraction force on the miniscrew and transpalatal arch wire. The purpose of this study is to determine the location of the miniscrew and the point of force application of the anchorage system in the lingual orthodontics. The analysis results indicate the efficient position of the miniscrew and the transpalatal arch wire in the lingual orthodontics.

  • PDF

METAL RELEASE FROM BRACKETS AND ARCHWIRES (BRACKET과 호선의 금속유리)

  • Park, Soo Byung;Rhee, Byung Tae
    • The korean journal of orthodontics
    • /
    • v.19 no.2
    • /
    • pp.75-84
    • /
    • 1989
  • The purpose of this experiment was to measure the amounts of nickel and chromium released from a simulated orthodontic appliance in artificial saliva. Simulated mandibular half-arch orthodontic appliances were composed of American Iron and Steel Institute type 304 brackets, Permachrome, Elgiloy, Australian wire, T.M.A. and Nitinol. The amounts of nickel and chromium released from sample were measured with atomic absorption spectrophotometer after 3, 6, 9, 12, 15 days. The cumulative amounts of nickel released from Permachrome, Elgiloy, Australian wire and T.M.A. reached a plateau after 6 days. But the cumulative amounts of nickel released from Nitinol increased continuously. Significant amounts of both nickel and chromium were solubilized from the simulated orthodontic appliances into artificial saliva. After 15 days, total cumulative amounts of nickel were $152.15{\mu}g$, $150.27{\mu}g$, $134.74{\mu}g$, $114.67{\mu}g$ and $93.39{\mu}$ from the Elgiloy, Australian wire, Nitinol, Permachrome and T.M.A., respectively. Total cumulative amounts of chromium from Permachrome, Australian wire, Elgiloy, Nitinol and T.M.A. were $100.83{\mu}g$, $83.64{\mu}g$, $81.61{\mu}g$, $14.90{\mu}g$ and $12.43{\mu}g$, respectively. The result showed that nickel released from Elgiloy and chromium released from Permachrome were more than any others.

  • PDF

Variations in surface roughness of seven orthodontic archwires: an SEM-profilometry study

  • Amini, Fariborz;Rakhshan, Vahid;Pousti, Maryam;Rahimi, Hajir;Shariati, Mahsa;Aghamohamadi, Bahareh
    • The korean journal of orthodontics
    • /
    • v.42 no.3
    • /
    • pp.129-137
    • /
    • 2012
  • Objective: The purpose of this study was to evaluate the surface roughness (SR) of 2 types of orthodontic archwires made by 4 different manufacturers. Methods: This in vitro experimental study was conducted on 35 specimens of 7 different orthodontic archwires, namely, 1 nickel-titanium (NiTi) archwire each from the manufacturers American Orthodontics, OrthoTechnology, All-Star Orthodontics, and Smart Technology, and 1 stainless steel (SS) archwire each from the manufacturers American Orthodontics, OrthoTechnology, and All-Star Orthodontics. Aft er analyzing the composition of each wire by energy-dispersive X-ray analysis, the SR of each wire was determined by scanning electron microscopy (SEM) and surface profilometry. Data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests (${\alpha}$ < 0.05). Results: The average SR of NiTi wires manufactured by Smart Technology, American Orthodontics, OrthoTechnology, and All-Star Orthodontics were $1,289{\pm}915A^{\circ}$, $1,378{\pm}372A^{\circ}$, $2,444{\pm}369A^{\circ}$, and $5,242{\pm}2,832A^{\circ}$, respectively. The average SR of SS wires manufactured by All-Star Orthodontics, OrthoTechnology, and American Orthodontics were $710{\pm}210A^{\circ}$, $1,831{\pm}1,156A^{\circ}$, and $4,018{\pm}2,214A^{\circ}$, respectively. Similar to the results of profilometry, the SEM images showed more defects and cracks on the SS wire made by American Orthodontics and the NiTi wire made by All-Star Orthodontics than others. Conclusions: The NiTi wire manufactured by All-Star Orthodontics and the SS wire made by American Orthodontics were the roughest wires.

THE STUDY 0F TENS10N CHARACTERISTICS IN ORTHODONTIC WIRES (교정용 철사의 인장 특성에 관한 연구)

  • Park, Dae-Han;Ryu, Young-Kyu
    • The korean journal of orthodontics
    • /
    • v.14 no.2
    • /
    • pp.241-248
    • /
    • 1984
  • The mechanical properties of Cr-Ni alloy of austenitic stainless steel and Co-Cr alloy orthodontic wires were studied in tension. The wires (0.018 inch) were tested in the as-manufactured and heat-treated conditions. Instron type tension testing machine was used for this study. Mean values and standard deviations were computed. The results were as follows; 1. The Cr-Ni orthodontic wires of austenitic stainless steel are generally superior than the Co-Cr orthodontic wires in ultimate tensile strength, In the elongation, however, Co-Cr orthodontic wire are superior than Cr-Ni orthodontic wires. 2. Increase in the degree of strength by heat treatment are more clearly shown in Co-Cr orthodontic wires than Cr-Ni orthodontic wires. And the elongation is decreased by heat treatment in both case. 3. The changes of the degree of strength by cooling method we not clearly shown, but in Cr-Ni orthodontic wires, air cooling are more effective, in Co-Cr orthodontic wires, cooling effect are scarcely shown.

  • PDF

A COMPARATIVE STUDY ON PHYSICAL PROPERTIES OF ORTHODONTIC STAINLESS STEEL WIRES (교정용 스테인리스강선재의 물리적 성질에 관한 비교연구)

  • Kwon, Oh-Won;Sohn, Byung-Hwn
    • The korean journal of orthodontics
    • /
    • v.15 no.2
    • /
    • pp.163-174
    • /
    • 1985
  • The requirements of orthodontic wire should include chemical stability, non-discoloration and non-corrosion in oral environment. Ability to be soldered, ease of fabrication and elasticity should be also considered. The purpose of this study was to compare and analyze the physical properties of Tru-chrome wire and manufactured E.S.S. (Experimental Stainless Steel) wire similar to Tru-chrome. The results were as follows: 1. Tru-chrome wire and E.S.S. wire were SUS 304 which was 18 Cr-8Ni austenite stainless steel. There was not significant difference in each composition between two wires. 2. There were not significant differences in ultimate tensile strength, yield strength, elongation and modulus of elasticity between Tru-chrome and E.S.S. wires. 3. There was not significant difference between flexuree modulus of elasticity of Tru-chrome and E.S.S. wires. 4. Micro-hardness value of E.S.S. wire was more than that of Tru-chrome wire and they were softened significantly by solution heat reatment. 5. Micro-structure of Tru-chrome and E.S.S. wires showed fibrous interlocking grains, and an austenite structure after solution heat treatment. 6. There was significant difference between corrosion rate of Tru-chrome and E.S.S. wires.

  • PDF

AN EXPERIMENTAL STUDY ON CHANGES OF ORTHODONTIC WIRES AFTER ELECTROPOLISHING (전해연마후 교정선의 변화에 관한 실험적 연구)

  • Lee, Jai-Chul;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.22 no.4 s.39
    • /
    • pp.823-836
    • /
    • 1992
  • Guiding a tooth along an arch wire results in a counteracting frictional force among arch wires, bracket and ligature. This frictional forces should be eliminated or minimized when orthodontic teeth movement is being planned. The purpose of this study was to evaluate the changes of width, cross-sectional forms and surface morphologies of stainless steel wire and $Elgiloy^{\circledR}$ wire after electropolising. Experimental variables included in this experiment were arch wire materials, current, electrolyte temperature and polishing time. Wire widths were measured by micrometer and cross-sectional forms and surface morphologies were examined with optical microscope and scanning electron microcope. The results were as follows: 1. The mean and standard deviation of widths of stainless steel wire and $Elgiloy^{\circledR}$ wire varying polishing time with condition of $249A/dm^2$ and $20^{\circ}C,\;249A/dm^2$ and, $332A/dm^2$ and $20^{\circ}C$ and $332A/dm^2$ and $250^{\circ}C$ were obtained. 2. With increasing polishing time, the widths of stainless steel wire and $Elgiloy^{\circledR}$ wire became decreased proportionally 3. The changes of widths of stainless steel wire and $Elgiloy^{\circledR}$ wire were statistically insignificant between $20^{\circ}C$ group and $25^{\circ}C$ group, but significant between $249A/dm^2$ group and $332A/dm^2$ group. 4 The cross-sectional forms of wire after electropolishing were not changed in stainless steel wire, and while it were changed to rounded corners in $Elgiloy^{\circledR}$ wire. 5. The surface morphologies of wire after electropolishing were scratch-absent and more smoothened both in stainless steel wire and $Elgiloy^{\circledR}$ wire.

  • PDF

A PHOTOELASTIC STUDY OF THE EFFECT OF LOOPS IN ARCH WIRE AND ORTHODONTIC ELASTICS IN RELIEF OF CURVE OF SPEE (호선에 부여한 loop와 교정용 고무가 치궁만곡도 개선에 미치는 영향에 관한 광탄성학적 연구)

  • Rhee, Byung-Tae
    • The korean journal of orthodontics
    • /
    • v.23 no.4 s.43
    • /
    • pp.485-492
    • /
    • 1993
  • Multiloop Edgewise Archwire(MEAW) is effective in relief the Curve of Spee in mandibular arch but up Sl down orthodontic elastics must be used with it. The purpose of this study was to analyse the effect of orthodontic elastics, like as up & down elastics, Class II elastics, and Class III elastics, and the effect of L loop in Multioop Edgewise Archwire. 1. Intrusive force of MEAW in anterior teeth was reduced and uprighting force in premolars was increased by up & down elastics. 2. Uprighting force was significintly increased with Class III elastics in multiple L loop arch wire. 3. The force of Class II elastics made molars tip mesially and Curve of Spee deep.

  • PDF

A Method to Compute Bending Angle for Robotic Shaping of Orthodontic Archwire (로봇을 이용한 치과 보철용 아치와이어 제작을 위한 굽힘각 계산 방법)

  • Chung, Seong Youb;Song, Il Jae;Hwang, Myun Joong
    • Journal of Institute of Convergence Technology
    • /
    • v.7 no.2
    • /
    • pp.17-20
    • /
    • 2017
  • Orthodontic treatment is accomplished by attaching an archwire to a bracket on tooth. The shape of the archwire is usually planned from 3-D scanned data of patient's teeth. It is manufactured by bending a metal wire and there have been some researches in progress to automate it. In this paper, we propose a method to obtain the bending angle at the bending point from the shape data of the archwire and verify it by simulation using actual archwire data.

A STUDY ON THE TORQUE EFFECT OF ORTHODONTIC WIRES (교정용 선재의 TORQUE 효과에 관한 연구)

  • Lim, Jeong-Hyeon;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.24 no.1 s.44
    • /
    • pp.87-94
    • /
    • 1994
  • The purpose of this study was to evaluate the torque effect of othodontic wires. Ten types of orthodontic wires (five types of materials, two types of cross-sectional dimensions) were selected. Each group of ire type was constituted with five specimens. These specimens were tested on the universal testing machine(Instron) with specially-designed jig. The torque-twist curve of each wire was obtained and the results were analyzed statistically. The results were as follows. 1. 0.017'$\times$ 0.025' wire showed more torque effect than 0.016'$\times$ 0.022' wire at the same twist. 2.Torque effect was the greatest in stainless steel and the least in Nitinol. 3.The maximum amount of torque was the greatest in heat-treated Blue Elgiloy and the least in Nitinol.

  • PDF