• Title/Summary/Keyword: Orthodontic wire

Search Result 144, Processing Time 0.028 seconds

THE PHYSICAL PROPERTIES OF TIN ION-FLAYED CO-CR(ELGILOY) ORTHODONTIC WIRES (TiN 피막처리된 Co-Cr계 교정용 선재의 물성)

  • KIM, Jung-Min;KWON, Oh-Won;KIM, Kyo-Han
    • The korean journal of orthodontics
    • /
    • v.28 no.3 s.68
    • /
    • pp.371-377
    • /
    • 1998
  • To estimate the possibility of clinical application of TiN ion-Plated Elgiloy(Co-Cr wire), measurements of tensile strength and hardness were made on the four tempers on each of the manufactured Elgiloy, the (heat-treated) Elgiloy for 30 minutes at $250^{\circ}C$ and the TiN ion-plated Elgiloy. For comparison, the tensile strength and hardness of Stainless Steel wires were also measured. The following are the results of the study: $\cdot$In the 4 tempers, tensile strength was the greatest in the TiN ion-plated group, followed by the heat-treated Elgiloy group and the manufactured Elgiloy group, but no statistical difference was noticed between heat-treated and manufactured Elgiloy groups(p>0.05). $\cdot$In each temper, tensile strength of ion-plated Elgiloy increased about $10kgf/mm^2$ in comparison with the values of the manufactured Elgiloy $\cdot$In yellow, green and red tempers except the blue, hardness was the greatest in ion-plated group. In the blue temper, there was no statistical difference between heat-treated and manufactured Elgiloy groups(p>0.05). $\cdot$In each temper, hardness of ion-plated Elgiloy increased about 50-90VHN in comparison with the values of the manufactured Elgiloy. $\cdot$The tensile strength of Stainless Steel wire was similar to that of the red temper of manufactured Elgiloy and the green temper of ion-plated Elgiloy.

  • PDF

ERUPTION GUIDANCE OF IMPACTED MANDIBULAR SECOND MOLAR (매복된 하악 제2대구치의 맹출 유도)

  • Lee, Hye-Lim;Lee, Kwang-Hee;La, Ji-Young;An, So-Youn;Kim, Yun-Hee;Lim, Hwa-Shin;Lee, Je-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.4
    • /
    • pp.404-411
    • /
    • 2012
  • Tooth impaction is defined as a failure of tooth eruption resulting from the physical obstacles in the eruption path or the abnormal position of the tooth germ. Impaction of mandibular second molar is relatively rare, and it may incite pathologic conditions such as dental caries, periodontitis, or root resorption of adjacent first molar. Thus, early diagnosis and treatment is recommended. In the first case, a 10-year-old male patient, was treated by brass wire to separate the bilaterally impacted mandibular second molars. In the second case, a 12-year-old female patient, was treated with Humphrey appliance for impacted mandibular left second molar, which was detected during a periodical dental examination. In the third case, a 17-year-old female patient with impacted mandibular right second molar, was treated by uprighting spring with mini-implant anchorage around premolar area. In the last case, an 18-year-old male patient, was treated with mini-implant placed on the ramus of mandible connected to the orthodontic buttons bonded on impacted mandibular left second molar by elastic thread.

Changes in surface roughness of bracket and wire after experimental sliding - preliminary study using an atomic force microscopy (브라켓과 탄선 간의 마찰 전후 표면 변화 분석 - 원자현미경을 이용한 예비연구)

  • Lee, Tae-Hee;Park, Ki-Ho;Jeon, Ji-Yun;Kim, Su-Jung;Park, Hun-Kuk;Park, Young-Guk
    • The korean journal of orthodontics
    • /
    • v.40 no.3
    • /
    • pp.156-166
    • /
    • 2010
  • Objective: The surface roughness of orthodontic materials is an essential factor that determines the coefficient of friction and the effectiveness of tooth movement. The aim of this study is to evaluate the surface roughness change of the brackets and wires after experimental sliding quantitatively. Methods: Before and after experimental sliding tests, the surface roughness of stainless steel brackets, ceramic brackets, stainless steel wires, and beta-titanium (TMA) wires were investigated and compared using atomic force microscopy (AFM). Results: After sliding tests, changes in the surface of the wire were greater than changes in the bracket slot surface. The surface roughness of the stainless steel bracket was not significantly increased after sliding test, whereas the roughness of ceramic brackets was decreased. Both the surface roughness of stainless steel and TMA wires were increased after sliding test. More changes were observed on the ceramic bracket than the stainless steel bracket. Conclusions: AFM is a valuable research tool when analyzing the surface roughness of the brackets and wires quantitatively.

Comparative Analysis of Stress Distribution in Composite Resin Brackets with Metal Slot of Permanent Maxillary Central Incisor Using the Finite Element Method: A Pilot Study

  • Im, Jae-Jung;Song, Jae-Joon;Kim, Nan-Hee;Heo, Jin-Young;Jung, Gyu-Un;Hwang, Kyung-Gyun;Park, Chang-Joo
    • Journal of Korean Dental Science
    • /
    • v.4 no.2
    • /
    • pp.46-51
    • /
    • 2011
  • Purpose: For aesthetic reasons, composite resin brackets are widely used. However, related studies are rare. This pilot study sought to compare the stress distributions in two commercially available composite resin brackets with metal slot. Materials and Methods: Two commercially available resin brackets -- full-metal slot resin bracket (fSRB) and partial-metal slot resin bracket (pSRB) with straight wire appliance dimension of $0.022{\times}0.028$ in -- were selected. In each bracket, 3-dimensional finite element models were constructed, and stress level was evaluated using finite element analysis. By loading the tipping force and torsion moment, which are similar to those applied by the stainless steel rectangular wire ($0.019{\times}0.025$ -in), stress distributions were calculated, and von Mises stress values were obtained. Results: In pSRB and fSRB, the stress value of the torque moment was much higher than that of the tipping force. The pSRB showed higher stress value than fSRB in both tipping force and torque moment because of the difference in size and configuration of the metal frame inserted into the slot. More stress was also found to be concentrated on the slot area than the wing area in fSRB. Conclusion: The slot form of fSRB was found to be more resistant to the stress of tipping and torque than the slot form of pSRB. In addition, the slot areas -- rather than the wing areas -- of the bracket showed breakage susceptibility. Therefore, resistance to the torque moment on the slot area should be considered in bracket design.

INHIBITION OF ARTIFICIAL PLAQUE BY MUTANASE PRODUCED FROM Streptomyces exfoliatus (Streptomyces exfoliatus가 생성하는 mutanase에 의한 인공치태 억제 작용)

  • Song, Do-Won;Yang, Kyu-Ho;Chung, Jin;Oh, Jong-Suk
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.2
    • /
    • pp.449-459
    • /
    • 1997
  • The main component of dental plaque is the mutan containing the a-1,3 bond. The following results were obtained by using a blue mutan to assess the factors affecting the mutan-digesting activity of Streptomyces exfoliatus isolated from soil. A clear zone was produced by mutanase-producing Streptomyces exfoliatus on the minimal essential agar containing blue mutan. Streptomyces exfoliatus digested more blue mutan in the minimal essential broth at pH 7.0 than at pH 5.5 or 8.5. Streptomyces exfoliatus digested more blue mutan at $37^{\circ}C$ than at $32^{\circ}C$ or $42^{\circ}C$ (P<0.05). When the concentration of $CaCl_2$ was increased in the minimal essential broth, the digestion of blue mutan was increased (P<0.05). The optimal concentration of KCl was 10mM to digest blue mutan, but a similar amount of blue mutan was digested at the range of 0.1mM to 6.4mM of $MgCl_2$. When the culture supernatant of Streptomyces exfoliatus was mixed with 2X brain heart infusion broth containing 0.5% yeast extract and 10% sucrose, less artificial plaque was formed by Streptococcus mutans on the orthodontic wire (P<0.05). These results indicated that the secretion of mutanase was identified in culture supernatant of mutan-digesting Streptomyces exfoliatus, suppressing the formation of artificial plaque by Streptococcus mutans.

  • PDF

Managing Complications Related to Multiple Supernumerary Teeth (다수 과잉치로 인한 합병증 치료의 임상적 고찰)

  • Kim, Jongbin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.41 no.2
    • /
    • pp.180-186
    • /
    • 2014
  • One or two mesiodens are mostly common to the clinician. However, three mesiodens is rarely found and can cause complications such as orthodontic problems or interruptions of the adjacent teeth with more than 1 or 2 mesiodens. Many factors cause irregularities in the permanent dentition. Mesiodens, especially in the anterior maxilla, can disturb the eruption of adjacent permanent teeth and cause diastemas, ectopic eruptions, root resorption, or the formation of dentigerous cysts. The early diagnosis of mesiodens is important for preventing such complications, and the timing of intervention should be based on their location and number. Periodic checkups and improved diagnostic devices make it easy to find mesiodens and associated complications. In this case, 3 supernumerary teeth in the maxillary anterior region were affecting the eruption of the adjacent permanent incisors. To minimize complications and preserve the deciduous teeth, the three supernumerary teeth were extracted in 2 steps. Since cone-beam computed tomography was not available, a brace wire was used to measure the depth of the mesiodens.

Comparison of frictional forces between aesthetic orthodontic coated wires and self-ligation brackets

  • Kim, Yunmi;Cha, Jung-Yul;Hwang, Chung-Ju;Yu, Hyung Seog;Tahk, Seon Gun
    • The korean journal of orthodontics
    • /
    • v.44 no.4
    • /
    • pp.157-167
    • /
    • 2014
  • Objective: The purpose of this study was to evaluate the clinical efficacy of polymer- and rhodium-coated wires compared to uncoated wires by measuring the frictional forces using self-ligation brackets. Methods: 0.016-inch nickel titanium (NiTi) wires and $0.017{\times}0.025$-inch stainless steel (SS) wires were used, and the angulations between the brackets and wires were set to $0^{\circ}$, $5^{\circ}$, and $10^{\circ}$. Upper maxillary premolar brackets (Clippy-C$^{(R)}$) with a 0.022-inch slot were selected for the study and a tensile test was performed with a crosshead speed of 5 mm/min. The maximum static frictional forces and kinetic frictional forces were recorded and compared. Results: The maximum static frictional forces and the kinetic frictional forces of coated wires were equal to or higher than those of the uncoated wires (p < 0.05). The maximum static frictional forces of rhodium-coated wires were significantly higher than those of polymercoated wires when the angulations between the brackets and wires were set to (i) $5^{\circ}$ in the 0.016-inch NiTi wires and (ii) all angulations in the $0.017{\times}0.025$-inch SS wires (p < 0.05). The kinetic frictional forces of rhodium-coated wires were higher than those of polymer-coated wires, except when the angulations were set to $0^{\circ}$ in the 0.016-inch NiTi wires (p < 0.05). Conclusions: Although the frictional forces of the coated wires with regards to aesthetics were equal to or greater than those of the uncoated wires, a study under similar conditions regarding the oral cavity is needed in order to establish the clinical implications.

PHYSICAL PROPERTIES AND SURFACE TOPOGRAPHY OF ORTHODONTIC STAINLESS STEEL WIRES : COMPARING A NEW KOREAN PRODUCT WITH OTHERS FROM FOREIGN COMPANIES (여러 스테인레스 스틸 호선의 물성 및 표면의 비교)

  • Lee, Sung-Ho;Kim, Tae-Woo;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.149-157
    • /
    • 2001
  • The purpose of this study was to investigate the property of a new Korean stainless steel wire(Jinsung Ind.) comparing with other foreign Products. Five types of stainless steel wires (Standard, Resilient, HI-T of Unitek, Stainless steel of Ormco and Jinsung Ind.) in 0.016x0.022 and 0.019x0.02 were tested to observe for Composition analysis, size difference, tensile properties, flexure bending property, tortion property, surface hardness and surface topography by means of SEM. The findings suggest that: 1. In maximum tensile strength of tensile properties, Unitek Hi-T showed the greatest value, followed by Unitek Resilient, Jinsung Stainless Steel, Ormco Stainless Steel, Unitek Standard in 0.016x0.022, and Unitek Hi-T showed highest value, followed by Jinsung Stainless Steel, Ormco Stainless Steel, Unitek Resilient, Unitek Standard in 0.019x 0.025. 2. In elongation rate, Unitek Standard showed the greatest value, fellowed by Ormco Stainless Steel, Unitek Hi-T, Unitek Resilient, Jinsung Stainless Steel in 0.016x0.022, and Unitek Hi-T showed the highest value, followed by Unitek Standard, Ormco Stainless Steel, Jinsung Stainless Steel, Unitek Resilient in 0.019x0.025. 3. In modulus of elasticity, Jinsung Stainless Steel showed the greatest value, followed by Unitek Hi-T, Unitek Resilient, Ormco Stainless Steel, Unitek Standard in 0.016x0.022, and Unitek Resilient showed the highest value followed by Jinsung Stainless Steel, Ormco Stainless Steel, Unitek Hi-T, Unitek Standard in 0.019x0.025. 4. In bending fatigue test, Jinsung Stainless Steel showed the greatest fracture resistance, followed by Unitek Hi-T, Unitek Standard, Unitek Resilient, Ormco Stainless Steel in 0.016x0.022, and Unitek Hi-T showed the greatest fracture resistance followed by Jinsung Stainless Steel, Unitek Resilient, Unitek Standard, Ormco Stainless Steel in 0.019x0.025. 5. In twist test, Unitek Resilient showed the greatest fracture resistance, followed by Jinsung Stainless Steel, Unitek Hi-7, Ormco Stainless Steel, Unitek Standard in 0.016x0.022, and Jinsung showed the greatest fracture resistance, followed by Unitek Resilient, Unitek Standard, Ormco Stainless Steel, Unitek Hi-T. 6. In surface topography, every products showed indentation and pitting. Jinsung stainless steel wire showed long thin indentation and relatively smooth surface. Unitek wires showed indentation and pitting and Ormco wire showed a lot of irregular pittings.

  • PDF

Periodontal Tissue Response Following Different Types of Fixed Retainers in Young Adult Dogs (수종의 고정성 보정장치에 따른 유성견의 치주조직 반응)

  • Jo, Myung-Hun;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.85-95
    • /
    • 2001
  • The purpose of this study was to evaluate the material for fixed type retainer, allowing physiologic tooth movement. and proper remodeling or periodontal tissue during retention period. The Present study was Performed to observe the histologic changes of periodontal tissue after application of different types of fixed type retainer after orthodontic tooth movement in young adult dogs. For this study, 4 young adult dogs were used as a experimental animal and experimental group was divided into three groups : experimental group 1 contained right side maxillayy third incisors and canines, experimental group 2 contained contralateral teeth of same animals, and control group contained mandibular premolars. And each dogs were applied the 4 different types of fixed type retainer to experimental group 1. The experimental teeth were ligated on the Sentalloy closed coil $spring^{\circledR}$(Tomy Co., Japan) from maxillary third incisors and canines and applied orthodontic force at initial 200gm-forced during 1 week. All the experimental animals were sacrificed on the 3rd week after the orthodontic teeth movement and then the specimens were taken, fixed in formalin, embeded in parafin, sectioned $6-8{\mu}m$ in thickness and stained with Hematoxylin-Eosin staining, and Masson's trichrome staining method. Examined under the light microscopy The following results were observed. 1. There were observed that decreased infiltration of giant tells in pressure side and increased the new bone forming in tension side on the specimen of 6-stranded 0.0195' $Respond^{\circledR}$(G&H Co., U.S.A.) group. Periodontal ligament fibers were much compressed or elongated in 3-stranded 0.018', 0.020' $Dentaflex^{\circledR}$(Dentarum Co., Germany), and Superbond $C&B^{\circledR}$(Sun Medical Co., Japan) groups. 2. In experimental group 1, necrotic bone inside the alveolar bone of pressure side, forming of the sharpey's fiber in osteoid tissue, and remodeling of the periodontal ligament were observed in all animals. 3. In experimental group 2, it was observed that the amount of bone resorption was equal or decreased in pressure side, and increased new bone forming and significantly decreased infiltration of giant cell than the experimental group 1. By this results, it considered that 6-stranded $Respond^{\circledR}$(G&H Co., U.S.A.) wire was the most useful material allowing early periodontal tissue remodeling.

  • PDF

THE EFFECT OF LIGATION METHOD ON THE FRICTIONAL FORGE BETWEEN ORTHODONTIC BRACKET AND ARCHWIRE (결찰양식이 교정용 브라켓과 교정선 사이의 마찰력에 미치는 영향)

  • Shin, Hyun-Jeong;Kwon, Oh-Won;Kim, Kyo-Han
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.813-823
    • /
    • 1998
  • The frictional force has been considered as an harmful factor in an active unit where tooth movement occurs, but as an advantageous factor in anchor unit that resist tooth movement. That is, efficient tooth movement is planned by using ligation methods that have low levels of bracket-wire frictional force and the anchorage control can be achieved by using ligation methods that have high levels of bracket-wire frictional force that result in binding of the bracket accompanied by little or no tooth movement. The purpose of this study was to evaluate the frictional force generated between bracket and wire in accordance with the methods of ligation, the material of ligation and the passage of time under artificial saliva. Tested were 0.017x0.022 inch stainless steel wires in standard edgewise twin brackets for upper central incisors in a 0.018-inch slot. The wires were ligated into the brackets with elastomeric modules and stainless steel ligatures. Whole tie, half tie, twisting tie and double overlay tie were done with elastomeric modules. With 0.009-inch stainless steel ligature whole tie and half tie were done by needle holder and whole tie by ligature tying plier. With 0.012-inch stainless steel ligature whole ties were done by needle holder. Whole tie groups of elastomeric module were kept in artificial saliva bath at $37^{\circ}C$ for 28 days. The frictional force was recorded by means of an Instron universial testing instrument (4202 INSTRON, Instron Co., U.S.A.) at initial, 7, 14, 21, and 28 days. The results for ligated samples in a simulated oral environment revealed the fellowing : ${\cdot}$In elastomeric module whole tie, 28 days group was significantly greater mean static frictional force than any other group but there were no significant differences among any other group (p>0.05). ${\cdot}$Elastomeric module twisting ties were significantly greater mean static frictional forces than any other ligation method but there were no significant differences between twisting tie and double overlay tie (p>0.05). Twisting tie, double overlay tie, whole tie, half tie showed differences in decreasing order. ${\cdot}$Stainless steel half tie produced lower mean static frictional force than whole tie, ligation by ligature tying plier produced greater mean static frictional force than by needle holder and ligation with 0.012-inch stainless steel ligature produced greater mean static frictional force than with 0.009-inch stainless steel ligature (p<0.05). ${\cdot}$There were no significant differences between the mean static frictional forces of elastomeric whole tie and stainless steel whole tie (p>0.05).

  • PDF