• Title/Summary/Keyword: Orthodontic miniscrew

Search Result 61, Processing Time 0.039 seconds

REMOVAL TORQUE AND BONE FORMATION OF ORTHODONTIC MINISCREW IMPLANT (교정용 미니스크류 임플랜트의 제거회전력 및 골형성에 관한 연굴)

  • Yun, Young-Kuk;Ryu, Jae-Jun;Suh, Kyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.4
    • /
    • pp.492-505
    • /
    • 2007
  • Statement of problem: An orthodontic miniscrew implant has been used as a skeletal anchorage for orthodontic treatment. However, any relation among the influence of the cortical bone, morphologic differences of orthodontic miniscrew implants and new bone formation hasn't been made clear yet. Purpose: The purpose of this study was to evaluate whether the orthodontic miniscrew implant could work as an intraoral skeletal anchorage immediately and stably for orthodontic treatment after insertion of it. Material and methods: Two types of orthodontic miniscrew implants were used in this experiment; tapered type and straight type. One hundred and sixty eight orthodontic miniscrew implants were inserted into the tibiae of 21 rabbits and sacrificed on 3, 7, 11, 14, 21 and 28days later after insertion of them to study removal torque values and histologic and histomorphometric analyses. Results: The results were as follows. 1. The removal torque values of the tapered type were higher than those of the straight type in all groups(p<0.05). 2. There wasn't any distinguishing differences between the tapered type and the straight type about the new bone formation percentage. 3. The removal torque values for both the tapered type and the straight type were gradually decreased at early stages of the test but started to increase at the 7 days group of the straight type and the 11 days group of the tapered type. 4. New bone formation percentage was increased gradually for both the tapered and the straight types as time passed(p<0.05). 5. It was found that the tapered type showed lower values in the cortical bone about both the maximum equilibratory stress distribution and the maximum principal stress distribution than the straight type in linear finite elements analysis. Conclusion: According to the research, the removal torque values were decreased at 7 days group of the tapered type and 11 days group of the straight type after the insertion of the orthodontic miniscrew implants in tibiae of rabbits. Considering the human bone activity, it is better to apply the orthodontic force $3{\sim}4$ weeks later than to apply it immediately after the insertion of orthodontic miniscrew implants. Considering that general orthodontic force is about $250{\sim}500$ grams, the tapered type can be worked as a stable skeletal anchor age in an orthodontic treatment even if the orthodontic force is applied on it immediately after the insertion of it.

Study on the Retraction of Anterior Teeth for the Lingual Orthodontics with the Three-Dimensional Finite Element Method (유한요소법을 이용한 설측 치아교정시 전치부 후방견인에 관한 연구)

  • Song Jung-Han;Huh Hoon;Park Hyun-Sang
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.8 s.227
    • /
    • pp.1237-1244
    • /
    • 2004
  • The orthodontic surgery including lingual orthodontics has recently attracted a person's attention due to its functional and esthetic appreciation. The skeletal anchorage with the miniscrew is newly adopted in the lingual orthodontics to assist the upholding ability. The appliciation needs to understand the mechanism of the orthodontic appliance and its related orthodontic correction for optimal orthodontic treatment. There is, however, few information about the qualitative and quantitative effect of the orthodontic appliance with the miniscrew has not been well identified. In this paper, three dimensional finite element analysis is introduced to the lingual orthodontics in order to investigate the effect of the anterior retraction force on the miniscrew and transpalatal arch wire. The analysis determines the adequate location of the miniscrew and the point of force application of the anchorage system in the lingual orthodontics. The analysis results demonstrate the effect of the position of the miniscrew and the transpalatal arch wire on the lingual orthodontics.

The use of miniscrew as an anchorage for the orthodontic tooth movement (Miniscrew를 고정원으로 이용한 교정치료)

  • Kyung, Seung-Hyun;Lim, Jung-Ki;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.31 no.4 s.87
    • /
    • pp.415-424
    • /
    • 2001
  • Anchorage in orthodontics is very important factor for orthodontist to treat malocclusion from diagnosis and treatment planning to end of treatment. Skeletal anchorage like miniscrew is supposed to be more effective method in anchorage control than conventional anchorage which needs patient's good cooperation. So this article will be mentioned about various clinical application of miniscrew through the general investigation and case reports about orthodontic use of miniscrew, specially about screwing area and clinical consideration of miniscrew's screwing on midpalate. The changes of treatment philosophy and methods by using skeletal anchorage were summarized and following results were obtained. 1. The orthodontic anchorage changed from relative concept to absolute one. 2. Bodily movement of teeth gets easier and determinate force system is possible on biomechanical consideration. 3. Some part of treatment that needs surgical intervention is possible by just orthodontic treatment.

  • PDF

Study on the Retraction of Anterior Teeth in the Lingual Orthodontics with the Three-Dimensional Finite Element Method (유한 요소법을 이용한 설측 치아교정시 전치부 후방 견인에 관한 연구)

  • Song, Jung-Han;Hug, Hoon;Park, Hyun-Sang
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.198-203
    • /
    • 2004
  • In these days, the orthodontic surgery including lingual orthodontics has attracted a person' attention due to its functional and esthetic appreciation. The delivery of the optimal orthodontic treatment is greatly influenced by clinician' ability to predict and control the tooth movement by applying force system to dentition. The skeletal anchorage system with the miniscrew has been used recently in the lingual orthodontics to assist the anchorage control. Precise understanding of the force system produced from the various orthodontic appliances is necessary. However, the qualitative and quantitative effect of the miniscrew has not been identified well. In this paper, three dimensional finite element analysis is introduced on the lingual orthodontics to investigate the effect of anterior retraction force on the miniscrew and transpalatal arch wire. The purpose of this study is to determine the location of the miniscrew and the point of force application of the anchorage system in the lingual orthodontics. The analysis results indicate the efficient position of the miniscrew and the transpalatal arch wire in the lingual orthodontics.

  • PDF

THE USE OF MINISCREWS FOR TOOTH MOVEMENT IN CHILDREN (성장기 아동에서 miniscrew를 고정원으로 이용한 치아이동)

  • Kim, Sang-Min;Park, Ho-Won;Lee, Ju-Hyun;Seo, Hyun-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.4
    • /
    • pp.537-544
    • /
    • 2010
  • Anchorage control in orthodontic treatment is an important factor affecting treatment results. In the conventional approach, intra-oral anchorage such as application of differential force and moment, Nance holding arch and lingual arch, as well as extra-oral anchorage such as head gear were used for anchorage reinforcement. However, these anchorages may result in undesired tooth movement and require patient cooperation. To overcome these disadvantages, skeletal anchorage system was introduced as orthodontic anchorage. Types of skeletal anchorage include implant, onplant, miniplate and miniscrew. Especially, miniscrew has many advantages such as reduced patient cooperation, low cost and easy placement. Recently, it is successfully used in orthodontic treatment. This cases were treated using orthodontic miniscrews for retraction of ectopically erupting maxillary canine and impacted mandibular canine and intrusion of maxillary incisors.

Complications reported with the use of orthodontic miniscrews: A systematic review

  • Giudice, Antonino Lo;Rustico, Lorenzo;Longo, Miriam;Oteri, Giacomo;Papadopoulos, Moschos A.;Nucera, Riccardo
    • The korean journal of orthodontics
    • /
    • v.51 no.3
    • /
    • pp.199-216
    • /
    • 2021
  • Objective: The aim of this systematic review was to evaluate the complications and side effects associated with the clinical use of orthodontic miniscrews by systematically reviewing the best available evidence. Methods: A survey of articles published up to March 2020 investigating the complications associated with miniscrew insertion, in both the maxilla and mandible, was performed using 7 electronic databases. Clinical studies, case reports, and case series reporting complications associated with the use of orthodontic miniscrew implants were included. Two authors independently performed study selection, data extraction, and risk-of-bias assessment. Results: The database survey yielded 24 articles. The risk-of-bias assessment revealed low methodological quality for the included studies. The most frequent adverse event reported was root injury with an associated periradicular lesion, vitality loss, pink discoloration of the tooth, and transitory loss of pulp sensitivity. Chronic inflammation of the soft tissue surrounding the miniscrew with mucosal overgrowth was also reported. The other adverse events reported were lesion of the buccal mucosa at the insertion site, soft-tissue necrosis, and perforation of the floor of the nasal cavity and maxillary sinus. Adverse events were also reported after miniscrew removal and included secondary bleeding, miniscrew fracture, scars, and exostosis. Conclusions: These findings highlight the need for clinicians to preliminarily assess generic and specific insertion site complications and side effects.

An alternative approach to extruding a vertically impacted lower third molar using an orthodontic miniscrew: A case report with cone-beam CT follow-up

  • Cortes, Arthur Rodriguez Gonzalez;No-Cortes, Juliana;Cavalcanti, Marcelo Gusmao Paraiso;Arita, Emiko Saito
    • Imaging Science in Dentistry
    • /
    • v.44 no.2
    • /
    • pp.171-175
    • /
    • 2014
  • One of the most common oral surgical procedures is the extraction of the lower third molar (LTM). Postoperative complications such as paresthesia due to inferior alveolar nerve (IAN) injury are commonly observed in cases of horizontal and vertical impaction. The present report discusses a case of a vertically impacted LTM associated with a dentigerous cyst. An intimate contact between the LTM roots and the mandibular canal was observed on a panoramic radiograph and confirmed with cone-beam computed tomographic (CBCT) cross-sectional cuts. An orthodontic miniscrew was then used to extrude the LTM prior to its surgical removal in order to avoid the risk of inferior alveolar nerve injury. CBCT imaging follow-up confirmed the success of the LTM orthodontic extrusion.

The experimental study of early loading on the Miniplate in the beagle dog (성견의 하악골에 식립된 Miniplate에 가한 조기 부하의 영향에 관한 실험적 연구)

  • Chung, Yong-Koo;Lee, Young-Jun;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.33 no.4 s.99
    • /
    • pp.307-317
    • /
    • 2003
  • Conventional osseointegrated titanium implants have many limitations; large size, limited location for placement of the implant, severity of the surgery, discomfort of initial healing, difficulty of oral hygiene and uncontrollable force direction. Recently titanium miniscrew and miniplate have been used for an alternative to conventional dental implant. But in relation to miniplate, miniscrew has disadvantages in that more potential inflammation, light orthodontic force application and limited orthodontic application. This study was conducted to evaluate the effectiveness of miniplate by observing the reactions of peri-implant tissues to early orthodontic and orthopedic loading of titanium miniplate. In four adult beagle dogs 10 miniplates were inserted into the alveolar bone using 20 osseointegrated titanium screws. 4 miniplates were placed in two dogs(dogA, B) and 6 miniplates in two dogs(dogC, D). In dogA, B miniplates were loaded with 200gm of force immediately after placement for 15 weeks. In dogc, D, miniplates were loaded with 400gm of force immediately after placement for 8 weeks. Miniplates of dogA were removed, dogA was healed for 4 weeks, and the area which was removed of miniscrew was examined. Following an observation period, the miniplates including miniscrews and the surrounding bone of dogB and dogC, D were removed, respectively. Undecalcified section along the long axis of miniscrews were made and the degree of osseointegration was examined under the light microscope. The results were as follows. 1. In the histologic features there was direct contact between bone and miniscrew in all groups except one, dogC control group. The loaded miniscrew demonstrated only a slight increase of the osseous proximaty when compared with unloaded miniscrew 2. There was no significant difference of the osseointegration of Peri-miniscrew surface between dogB and dogC, D. But dogB showed slightly more increased bone apposition than dogC, D 3. The gingiva overlapping the miniplate and miniscrew showed no inflammatory sign in clinical and histological aspects. 4. The impaled hard and soft tissues at the area which was removed of miniscrews showed good healing without inflammatory reaction. 5. The mobility showed slight increase in un-loaded miniplate but that was insignificant. Based on the results of this study, miniplate(C-tube) can be used as a firm osseous orthodontic and orthopedic anchorage unit immediately after insertion.

A CLINICAL STUDY ON SKELETAL ANCHORAGE SYSTEM USING MINISCREW (구내고정원을 이용한 교정 치료중 miniscrew 탈락에 관한 연구)

  • Woo, Soon-Seop;Jeong, Soon-Tai;Huh, Young-Sung;Hwang, Kyung-Gyun;Yoo, Im-Hag;Shim, Kwang-Sup
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.2
    • /
    • pp.102-107
    • /
    • 2003
  • At orthodontic treatment, we have made every effort to get rigid anchorage which is not stirred when teeth move. As a result, the miniscrew that is rigid anchorage was invented recently, and now it is used widely. Concerning the advantage of miniscrew, it is reduced dependence of extraoral anchorage and it shortens treatment time for rapid tooth movement. In contrast, the defect of miniscrew is falling off it resulted from increasing of the mobility. So the purpose of this research is to be of help to prognose clinical use of miniscrew, which is inserted for intraoral anchorage, by investigating and comparing the failure rate of miniscrew for loading time. This study researches the failure rate of miniscrew for teeth movement at the orthodontic treatment. The failure rate of miniscrew in mid course, after inserting 147 miniscrews in 51 patients, is 13%(20/147). It showed no statistically significant differences as compared man with woman, maxilla with mandible, double-head with uni-head miniscrew, and drilling and non-drilling before inserting the miniscrew. In comparison below twenties with over twenties and the times that we give load to miniscrew, it produced that the failure rate of miniscrew is 9.7% higher in the case of below the twenties than over the twenties. Also, the failure rate of loading immediately is 10.8% higher than loading after 7 days. According to using driver for the insertion of miniscrew, the failure rate of miniscrew is higher in the case of using machined driver than in the case of using hand driver when the level of significance is 95%. According to the research, we can suppose that the failure rate has no concern with using miniscrew on man or woman, maxilla or mandible, the shape of head, and drilling or non-drilling before insertion of miniscrew. Therefore, we can choose eclectic miniscrew as demands. In addition, we must notify the patient, below twenties, to be possibility of high failure rate. And It is strongly recommended to give load after $1{\sim}2$ weeks for healing of the insertion area.

Identification of tumor necrosis factor-${\alpha}$ levels around miniscrews during canine distalization

  • Kaya, Filiz Acun;Hamamcl, Nihal;Uysal, Ersin;Yokus, Beran
    • The korean journal of orthodontics
    • /
    • v.41 no.1
    • /
    • pp.36-41
    • /
    • 2011
  • Objective: The aim of this study was to measure tumor necrosis factor-${\alpha}$ (TNF-${\alpha}$) levels around miniscrews used for anchorage during a 3-month period of canine distalization. Methods: Sixteen patients (8 boys, 8 girls; mean age, $16.6{\pm}2.4$ years) whose upper first premolars were extracted for orthodontic treatment were included in this study. Miniscrews were used as an anchorage unit in canine distalization. Thirty-two (32) miniscrew implants were placed bilaterally in the alveolar bone between the maxillary second premolars and first molars. The treatment, miniscrew, and control groups comprised upper canines, miniscrew implants, and upper first premolars, respectively. Peri-miniscrew implant crevicular fluid and gingival crevicular fluid were obtained before applying force and at 1, 24, and 48 hours, and at 7 and 21 days, and 3 months after applying force. Results: During the 3-month period, the (TNF-${\alpha}$) levels increased significantly at 24 hours only in the treatment group (p < 0.01). In the miniscrew and control groups, there were no statistically Significant changes. No significant differences were observed between groups. Conclusions: Miniscrews can be conveniently used for anchorage in orthodontics.