• Title/Summary/Keyword: Organs at risk

Search Result 142, Processing Time 0.022 seconds

Benefit of volumetric-modulated arc therapy over three-dimensional conformal radiotherapy for stage I-II extranodal marginal zone B-cell lymphoma of mucosa-associated lymphoid tissue in the stomach: a dosimetric comparison

  • Chung, Joo-Hyun;Na, Kyoungsu;Kim, Il Han
    • Radiation Oncology Journal
    • /
    • v.36 no.4
    • /
    • pp.332-340
    • /
    • 2018
  • Purpose: To retrospectively analyze dosimetric parameters of volumetric-modulated arc therapy (VMAT) and three-dimensional conformal radiotherapy (3D-CRT) delivered to extranodal marginal zone B-cell lymphomas of mucosa-associated lymphoid tissue in the stomach (gastric MALT lymphoma) to find out advantages of VMAT and conditions for definite benefits of VMAT. Materials and Methods: Fifty patients with stage I-II gastric MALT lymphoma received VMAT (n = 14) or 3D-CRT (n = 36) between December 2005 and April 2018. Twenty-seven patients were categorized according to whether the planning target volume (PTV) overlaps kidney(s). Dosimetric parameters were analyzed by dose-volume histogram. Results: Radiation dose to the liver was definitely lower with VMAT in terms of mean dose (p = 0.026) and V15 (p = 0.008). The V15 of the left kidney was lower with VMAT (p = 0.065). For those with PTV overlapping kidney(s), the left kidney V15 was significantly lower with VMAT. Furthermore, the closer the distance between the PTV and kidneys, the less the left kidney V15 with VMAT (p = 0.037). Delineation of kidney(s) by integrating all respiratory phases had no additional benefit. Conclusions: VMAT significantly increased monitor units, reduced treatment time and radiation dose to the liver and kidneys. The benefit of VMAT was definite in reducing the left kidney V15, especially in geometrically challenging conditions of overlap or close separation between PTV and kidney(s).

A Dosimetric Comparision of IMRT and VMAT in Synchronous Bilateral Breast Cancer (양측성 유방암의 세기조절방사선치료(IMRT)와 부피적조절회전방사선치료(VMAT)의 비교연구)

  • Kim, Sung-Jin;Youn, Seon-Min;Kim, Sung Kyu
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.284-289
    • /
    • 2013
  • A study was performed comparing dosimetric characteristics of volumetric modulated arc and intensity modulated radiatio therapy on patients with bilateral breast cancer. For 5 patients, 3 plans were made for each patient; IMRT beams 8 and 12 of the beam intensity modulated radiation therapy, volumetric modulated arc therapy plan. The average PTVs volumes and $D_{98}$ for 12-IMRT were $51.04{\pm}0.57$ Gy (right), $50.80{\pm}1.07$ Gy (left), $42.94{\pm}16.16$ Gy (right), $42.56{\pm}2.09$ Gy (left). HI ($D_5{\sim}D_{95}$) and $CI_{90,95}$, even 12-IMRT has shown excellent results. In OAR, 3 plans showed excellent results. But the lowest dose of 12-IMRT. 12-IMRT achieved similar PTV coverage and sparing of organs at risk than 8-IMRT and VMAT.

Dosimetric comparison of coplanar and non-coplanar volumetric-modulated arc therapy in head and neck cancer treated with radiotherapy

  • Gayen, Sanjib;Kombathula, Sri Harsha;Manna, Sumanta;Varshney, Sonal;Pareek, Puneet
    • Radiation Oncology Journal
    • /
    • v.38 no.2
    • /
    • pp.138-147
    • /
    • 2020
  • Purpose: To evaluate the dosimetric variations in patients of head and neck cancer treated with definitive or adjuvant radiotherapy using optimized non-coplanar (ncVMAT) beams with coplanar (cVMAT) beams using volumetric arc therapy. Materials and Methods: Twenty-two patients of head and neck cancer that had received radiotherapy using VMAT in our department were retrospectively analyzed. Each of the patients was planned using coplanar and non-coplanar orientations using an optimized couch angle and fluences. We analyzed the Conformity Index (CIRTOG), Dose Homogeneity Index (DHI), Heterogeneity Index (HIRTOG), low dose volume, target and organs-at-risk coverage in both the plans without changing planning optimization parameters. Results: The prescription dose ranged from 60 Gy to 70 Gy. Using ncVMAT, CIRTOG, DHI and HIRTOG, and tumor coverage (ID95%) had improved, low dose spillage volume in the body V5Gy was increased and V10Gy was reduced. Integral dose and intensity-modulated radiation therapy factor had increased in ncVMAT. In the case of non-coplanar beam arrangements, maximum dose (Dmax) of right and left humeral head were reduced significantly whereas apex of the right and left lung mean dose were increased. Conclusion: The use of ncVMAT produced better target coverage and sparing of the shoulder and soft tissue of the neck as well as the critical organ compared with the cVMAT in patients of head and neck malignancy.

Dosimetric Comparison of Noncoplanar and Coplanar Volumetric Modulated Arc Therapy Plans for Esophageal Cancer

  • Park, So-Yeon
    • Progress in Medical Physics
    • /
    • v.31 no.4
    • /
    • pp.179-188
    • /
    • 2020
  • Purpose: We compared noncoplanar volumetric modulated arc therapy (ncVMAT) plans to coplanar VMAT (cVMAT) plans by evaluating the dosimetric quality of each for esophageal cancer. Methods: Twenty patients treated for esophageal cancer with the cVMAT technique were retrospectively selected. The cVMAT plans consisted of three coplanar full arc beams. The ncVMAT plans consisted of two coplanar full arc beams and one noncoplanar partial arc beam ranging from 45° to 315° with a couch rotation angle of 315°±5°. For dosimetric evaluation, the dose-volumetric (DV) parameters of the planning target volume (PTV) and organs at risk (OARs) were calculated for all VMAT plans. Results: No clinically noticeable differences between the cVMAT and ncVMAT plans were observed in the DV parameters of the PTV. For the lungs, the V13 Gy and mean dose for ncVMAT plans were smaller than those for cVMAT plans, showing statistically significant differences. For the heart, the values of the maximum dose for cVMAT and ncVMAT plans were 53.8±2.9 and 50.9±3.3 Gy, respectively (P=0.004). For the spinal cord, the values of the maximum dose for cVMAT and ncVMAT plans were 37.1±5.1 and 34.7±5.7 Gy, respectively (P<0.001). Conclusions: The use of ncVMAT plans provides better PTV coverage and sparing of OARs compared to that of cVMAT plans for long, tube-like esophageal cancer. For esophageal cancer, the ncVMAT plans showed a more favorable plan quality than the cVMAT plans.

A Study of Radiation Dose Evaluation and Optimization Methods for Intra Oral Dental X-ray in Pediatric Patient (소아 구내촬영 시 방사선량 평가 및 최적화 방안에 대한 연구)

  • Lee, Hyun-Yong;Cho, Yong-In
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.195-203
    • /
    • 2021
  • Although intra oral dental x-ray is a lower dose than other radiological examinations, pediatric patients are known to have a higher risk of radiation damage than adults. For this reason, pediatric dental x-ray requires management of dose evaluation and imaging conditions during the examination. In this study, the dose calculation program ALARA-Dental(child/adult) was used to evaluate the organ dose and effective dose exposed to each examination site during intra oral imaging of children during dental radiographic examination, and dose analysis according to the imaging conditions was performed. As a result, the highest organ dose distribution was shown at 0.044 ~ 0.097 mGy in all are as of the mucous membrane of oral cavity except for the maxillary incisors and canines. Also, in the case of the thyroid gland, the maxillary canine and maxillary premolar examination showed 0.027 and 0.020 mGy, respectively, and the dose distribution was 15.4% to 70.0% higher than that of the mandibular examination. As for the effective dose calculated during intra oral imaging, the maxillary anterior and canine examinations showed the highest effective doses of 0.005 and 0.004 mSv, respectively, and the maxillary area examination showed a higher dose distribution on average than the mandible.

The Effect of Volume Reduction on Computed Treatment Planning during Head and Neck IMRT and VMAT (두경부 IMRT 및 VMAT 시 체적 감소가 전산화치료계획에 미치는 영향)

  • Ki-Cheon Um;Gha-Jung Kim;Geum-Mun Back
    • Journal of radiological science and technology
    • /
    • v.46 no.3
    • /
    • pp.239-246
    • /
    • 2023
  • In this study, we assessed the effect of reduction of tumor volume in the head and neck cancer by using RANDO phantom in Static Intensity-Modulated Radiation Therapy (S-IMRT) and Volumetric-Modulated Arc Therapy (VMAT) planning. RANDO phantom's body and protruding volumes were delineated by using Contour menu of Eclipse™ (Varian Medical System, Inc., Version 15.6, USA) treatment planning system. Inner margins of 2 mm to 10 mm from protruding volumes of the reference were applied to generate the parameters of reduced volume. In addition, target volume and Organ at Risk (OAR) volumes were delineated. S-IMRT plan and VMAT plan were designed in reference. These plans were assigned in the reduced volumes and dose was calculated in reduced volumes using preset Monitor unit (MU). Dose Volume Histogram (DVH) was generated to evaluate treatment planning. Conformity Index (CI) and R2 in reference S-IMRT were 0.983 and 0.015, respectively. There was no significant relationship between CI and the reduced volume. Homogeneity Index (HI) and R2 were 0.092 and 0.960, respectively. The HI increased when volume reduced. In reference VMAT, CI and R2 were 0.992 and 0.259, respectively. There was no relationship between the volume reduction and CI. On the other hand, HI and R2 were 0.078 and 0.895, respectively. The value of HI increased when the volume reduced. There was significant difference (p<0.05) between parameters (Dmean and Dmax) of normal organs of S-IMRT and VMAT except brain stem. Volume reduction affected the CI, HI and OAR dose. In the future, additional studies are necessary to incorporate the reduction of the volume in the clinical setting.

New records of two alien plants, Juncus torreyi (Juncaceae) and Egeria densa (Hydrocharitaceae) in Korea

  • Jongduk JUNG;Hye Ryun NA;Kyu Song LEE;Yeongmin CHOI;Woongrae CHO;Jin-Oh HYUN
    • Korean Journal of Plant Taxonomy
    • /
    • v.53 no.1
    • /
    • pp.54-59
    • /
    • 2023
  • Naturalized populations of two alien plants were newly found, and we describe their morphological characteristics and habitats with photographs. One is a member of Juncaceae, Juncus torreyi Coville, and was newly found at a pool of a beach in Gangwon-do. This rush is native to North America and belongs to the sect. Ozophyllum (subgen. Juncus) according to certain morphological characteristics, such as its racemose inflorescence, the absence of floral bracteole, and unitubular leaves with perfect septa. J. torreyi is easily distinguishable from Korean rushes by its long rhizomes with swollen nodes and globular head with 25-100 flowers. Its introduction into Japan and Europe was reported, but the ecological risk associated with its over-dispersal is not known. The other alien plant is a submerged plant, Egeria densa Planch. (Hydrocharitaceae), which was found in streams in Gyeongsangbuk-do and ditches in the Busan-si area, both of which being in the watershed of the Nakdong River. Egeria densa is similar to Hydrilla verticillata (L.f.) Royle, which is native to Korea. However, it is distinguished from H. verticillata by its larger flowers and lack of overwintering organs. This alien plant is native to South America and was introduced for aquarium gardening and naturalized around the world. Egeria densa is treated as a malignant weed due to its asexual reproduction and rapid growth. Size changes and the number of populations of E. densa must be investigated.

Minimization of Treatment Time Using Partial-Arc Volumetric Modulated Arc Therapy with Bladder Filling Protocol for Prostate Cancer

  • Hojeong Lee;Dong Woon Kim;Ji Hyeon Joo;Yongkan Ki;Wontaek Kim;Dahl Park;Jiho Nam;Dong Hyeon Kim;Hosang Jeon
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.101-107
    • /
    • 2022
  • Purpose: Radiotherapy after bladder filling protocol (BFP) is known to enhance treatment quality and reduce side effects in prostate cancer, a common male solid cancer globally. However, due to the need to hold back urine during treatment, patients frequently complain of discomfort, and treatment is frequently suspended when patients urinate during treatment and urine penetrates the treatment device, causing malfunction. Therefore, the effect of minimizing treatment time when partial-arc volumetric modulated arc therapy (VMAT) was used instead of full-arc was assessed in this study. Methods: A total of 70 plans were created in 10 patients using 7 different arc sizes, and the treatment time for each plan was calculated. Results: Reduced arc size by half resulted in a 54.4% decrease in mean treatment duration, with a proportional tendency observed. Furthermore, the effect of VMAT arc size reduction on target dose homogeneity was significantly limited, and the effect on surrounding organs at risk (OAR) was negligible. It should be noted, however, that when the arc size decreases by >40%, the dose increases in the area without OAR around the target. Conclusions: The results of this study demonstrated that partial-arc VMAT for enhancing treatment convenience and efficacy of prostate cancer patients undergoing BFP can achieve a considerable reduction in treatment time while preserving treatment quality, and it is expected to be useful for partial-arc VMAT plan design and implementation in practice.

Impact of 0.35 T Magnetic Field on Dose Calculation for Non-small Cell Lung Cancer Stereotactic Radiotherapy Plans

  • Jaeman Son;Sung Young Lee;Chang Heon Choi;Jong Min Park;Jung-in Kim
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.3
    • /
    • pp.117-123
    • /
    • 2023
  • Background: We investigated the impact of 0.35 T magnetic field on dose calculation for non-small cell lung cancer (NSCLC) stereotactic ablative radiotherapy (SABR) in the ViewRay system (ViewRay Inc.), which features a simultaneous use of magnetic resonance imaging (MRI) to guide radiotherapy for an improved targeting of tumors. Materials and Methods: Here, we present a comprehensive analysis of the effects induced by the 0.35 T magnetic field on various characteristics of SABR plans including the plan qualities and dose calculation for the planning target volume, organs at risk, and outer/inner shells. Therefore, two SABR plans were set up, one with a 0.35 T magnetic field applied during radiotherapy and another in the absence of the field. The dosimetric parameters were calculated in both cases, and the plan quality indices were evaluated using a Monte Carlo algorithm based on a treatment planning system. Results and Discussion: Our findings showed no significant impact on dose calculation under the 0.35 T magnetic field for all analyzed parameters. Nonetheless, a significant enhancement in the dose was calculated on the skin surrounding the tumor when the 0.35 T magnetic field was applied during the radiotherapy. This was attributed to the electron return effect, which results from the deviation of the electrons ejected from tissues upon radiation due to Lorentz forces. These returned electrons re-enter the tissues, causing a local dose increase in the calculated dose. Conclusion: The present study highlights the impact of the 0.35 T magnetic field used for MRI in the ViewRay system for NSCLC SABR treatment, especially on the skin surrounding the tumors.

Mixed adenoneuroendocrine carcinoma of the ampulla of Vater: Three case reports and a literature review

  • Min Kyu Sung;Woohyung Lee;Sarang Hong;Yejong Park;Bong Jun Kwak;Ki Byung Song;Jae Hoon Lee;Dae Wook Hwang;Song Cheol Kim
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.27 no.1
    • /
    • pp.107-113
    • /
    • 2023
  • Mixed adenoneuroendocrine carcinoma is defined as a tumor with a mixture of adenocarcinoma components and neuroendocrine neoplasm components. Each of these two components of mixed adenoneuroendocrine carcinoma accounts for at least 30% of all tumors. Mixed adenoneuroendocrine carcinoma might be located in the ampulla of Vater, a very rare location compared to other organs. Thus, its treatment and prognosis plans have not been established yet. We report three cases of mixed adenoneuroendocrine carcinoma occurring in the ampulla of Vater. Each patient had a different clinical course. In general, difficulty in preoperative diagnosis, risk of early recurrence, and poor disease course were main hallmarks of mixed adenoneuroendocrine carcinoma arising from the ampulla of Vater. However, one patient in this case report survived although she did not receive adjuvant chemotherapy due to her old age. Therefore, it is important to establish a careful treatment strategy for mixed adenoneuroendocrine carcinoma arising from the ampulla of Vater.