• 제목/요약/키워드: Organics and Nutrients Removal

검색결과 31건 처리시간 0.024초

Membrane-BNR 공정의 유동상 담체 호기조내 SND 평가 (SND in Fludized Media Aerobic Tank of Membrane-BNR Process)

  • 이정열;민경석
    • 한국물환경학회지
    • /
    • 제25권2호
    • /
    • pp.322-328
    • /
    • 2009
  • The advantage of simultaneous nitrification and denitrification (SND) is to reduce requirement of oxygen as well as tank volume. The fludized media was used in the oxic (aerobic) tank of Membrane-BNR to enhance the efficiency of SND. Nowadays, the interest of applying membrane to the wastewater treatment plant has been increased, which is proved by a lot of research published about the MBR. The Membrane-BNR, consisted of total 5 reactors might be called the compact process by using the fludized media and having short HRT of 6.5 hr. It could attain the further removal of not only the organics but also nutrients such as T-N and T-P. The mode A and B were identified with or without the step feed of influent. The mode A was classified with 3 modes according to the different DO concentration in the fludized media aerobic reactor, and the mode B with step feed was operated with the optimum DO condition. The step-feed was capable of improving TN removal efficiency under the domestic wastewater with the low ratio C/N. On the other hand, the efficiency of SND with the 1.0~1.5 mg/L DO in the oxic media tank was better than the one with below 1.0 mg/L, on which the nitrification did not happen enough, and with above 3.5 mg/L, on which the reduction of anoxic area in the tank happened. It means that the profitable nitrification should be performed prior to the denitrification step. The removal efficiency of nitrogen by SND was about 20% among of total denitrified nitrogen. And some organic carbon consumed could be reduced by the endogeneous denitrification.

미세기포를 이용한 오염 호소수의 정화에 관한 연구 (Study on the Treatment of Contaminated Lake Water Using Micro Air Bubbles)

  • 김준영;박창원;이종경;장인성
    • 한국환경과학회지
    • /
    • 제16권6호
    • /
    • pp.699-706
    • /
    • 2007
  • Many lakes or irrigative reservoirs in Korea are rapidly contaminated due to the ever increasing pollutants. Although lots of treatment processes have been recommended and practiced, economical and technical improvement is currently needed. In this study, contaminated irrigation reservoir was treated using the proposed process which is consisted of fine air bubbles, coagulation and flotation. Fine bubbles, approximate diameter of 3 to $10{\mu}m$, were generated using cavitation in the pressurized tank and polyaluminum chloride was used as coagulants. This fine bubbles, coagulation and flotation effectively controlled the low density algae, for example, Chlorophyll-a was removed more than 97 %. Removal efficiency of COD, SS, T-N and T-P were 80.7%, 94.3%, 64.1 % and 92.4%, respectively. Pollutants released from the sediments was removed more than 80% of organics and 60-70 % of nutrients. Consequently, fine bubbles coagulation and flotation process could be effectively used as an alternative treatment method for the purpose of control of lake water quality.

Correlation Analysis on the Runoff Pollutants from a Small Plot Unit in an Agricultural Area

  • Kang, Meea;Choi, Byoung-Woo;Lee, Jae-Kwan
    • Environmental Engineering Research
    • /
    • 제15권4호
    • /
    • pp.191-195
    • /
    • 2010
  • This study was carried out to investigate the important factors relating to runoff and pollutant loads in a plot unit located in an agricultural area. Of the precipitation parameters, such as total precipitation, days since last rainfall (ADD, the rainfall was more than 10mm) and average rainfall intensity on runoff, the strongest effect was obtained due to total precipitation, but the rainfall intensity showed a slightly positive correlation. It was expected that both variables, i.e. total precipitation and rainfall intensity, would lead to the generation of greater runoff. In contrast, runoff was negatively correlated with ADD, which is understandable because more infiltration and less runoff would be expected after a long dry period. The TSS load varied greatly, between 75.6 and $5.18{\times}10^4g$, per event. With the exception of TN, the TSS, BOD, COD and TP loads were affected by runoff. The correlations of these items were proportional to the runoff volume, with correlation coefficients (r) greater than 0.70, which are suitable for use as NPS model data. The TSS load showed very good relationships with organics (BOD & COD) and nutrients (TN & TP), with correlation coefficients greater than 0.79. Therefore, the removal of TSS is a promising factor for protecting water basins.

폐수의 고도처리를 위한 무산소/호기형 분리막생물반응조 - 역삼투 공정과 활성슬러지공정 - 정밀여과 - 역삼투 공정의 비교 (Comparison of Anoxic/Oxic Membrane Bioreactor - Reverse Osmosis and Activated Sludge Process-Microfiltration-Reverse Osmosis Process for Advanced Treatment of Wastewater)

  • 노성희;김선일;전홍화;송연호
    • 공업화학
    • /
    • 제17권5호
    • /
    • pp.521-526
    • /
    • 2006
  • 폐수를 재이용하기 위한 고도처리 시스템으로서 분리막 생물반응조(Membrane Bioreactor, MBR)는 기존의 활성슬러지 공정(Activated Sludge Process, ASP)에 비하여 많은 장점을 가지고 있다. 도시 하수 중에 포함된 유기물과 영양염류를 동시에 제거하기 위하여 침지형 정밀여과(Microfiltration, MF) 막을 이용한 무산소/호기(Anoxic/Oxic, A/O)형 MBR에서 투과플럭스를 $10.2L/m^2{\cdot}h$로 일정하게 유지하면서 고형물 체류시간(Solids Retention Time, SRT) 변화에 따른 막 여과 특성을 조사하였다. 실험 결과, SRT를 증가시킬수록 체외고분자물질(Extracellular Polymeric Substances, EPS)내 단백질/탄수화물(Protein/Carbohydrate, P/C) 비가 높아져서 막 오염이 빠르게 진행되었다. A/O MBR에 RO막을 결합한 A/O MBR-RO 공정을 폐수의 고도처리에 적용하고자 하였으며, 성능평가를 위해 A/O MBR-RO 공정과 기존의 활성슬러지 공정에 MF와 RO막을 결합한 ASP-MF-RO 공정의 유기물 및 영양염류 제거율을 비교하였다. 실험 결과 A/O MBR-RO 공정이 ASP-MF-RO 공정보다 더 우수한 처리효율을 나타내었다.

축산폐수 중의 난분해성 물질 및 암모니아 제거를 위한 Fenton 산화와 Zeolite 이온교환 공정의 적용 가능성 (Applicable Feasibility of Fenton Oxidation and Zeolite Ion Exchange Processes for Removal of Non-Biodegradable Matters and Ammonia in Livestock Wastewater)

  • 조창우;김병용;채수천;정팔진
    • 한국물환경학회지
    • /
    • 제23권5호
    • /
    • pp.600-606
    • /
    • 2007
  • Livestock wastewater containing concentrated organic matters and nutrients has been known as one of the major pollutants. It is difficult to apply the conventional activated sludge process to treat livestock wastewater because of high Non-biodegradable (NBD) matter and ammonia. The objectives of this study are to remove NBD matters including aromatic compounds and ammonia in livestock wastewater using Coagulation-Fenton oxidation-Zeolite (CFZ) processes and ascertain applicable feasibility in the field through pilot plant experiment. NBD matters and color remained in the treated water were removed over 92% by Fenton oxidation as the second treatment process. Ammonia was removed by over 99.5% in the zeolite ion exchange process as the last treatment method. From $UV_{254}$, $E_2/E_3$ ratio and GC/MS analyses of treated water at each process, the aromatic compound was converted to aliphatic and aromaticity was decreased. In pilot scale test, organics and ammonia removal efficiencies were not much different from the result of lab-scale test at various operation conditions. Furthermore, reaction time and dosage of Fenton reagent in pilot scale experiment reduced by 40 min and 50% rather than in lab-scale test. $BOD_5$, $COD_{Mn}$, SS, T-N and T-P of treated water in the pilot-scale experiment also met the effluent standards.

RBC와 점감포기조의 복합구성에 따른 유가공폐수 처리에 관한 연구 (Treatment of Dairy Wastewater by the Combination of RBC and tapered Aeration)

  • 이상호
    • 한국산학기술학회논문지
    • /
    • 제9권6호
    • /
    • pp.1733-1738
    • /
    • 2008
  • 고농도 유가공폐수의 유기물 및 질소, 인의 제거효율을 비교하기 위하여 두 개의 반응 시스템을 구성하였다. 하나는 하나의 RBC 반응조와 3단 점감포기조로 구성한 시스템이며 다른 하나는 RBC 반응조 2개를 연속으로 구성하고 3단 점감포기조로 구성한 시스템이다. 본 연구에 적용한 바실러스 미생물은 RBC의 끈상미생물접촉재에 부착하여 수행하였다. 각 시스템으로 유입되는 유가공폐수의 BOD 평균농도는 988mg/L, 1,046mg/L이었으며, 유출수 BOD 농도는 21.4mg/L, 15.9mg/L로 제거율은 97.8%, 98.5%의 결과를 보였다. RBC 단일공정 유입수의 평균 $COD_{cr}$ 농도는 1,837mg/L, 유출수는 53.0mg/L로 96.7%의 제거 효율을 보였으며 RBC 연속공정 유입수의 평균 $COD_{cr}$ 농도는 1,852mg/L, 유출수는 평균 27.8mg/L로 98.5%의 제거효율을 보였다. 유입수 T-N 분석결과 RBC 단일공정은 평균 51.9mg/L로 측정되었고, RBC 연속반응공정에서의 유입수 평균은 54.3mg/L이었으며, 유출수는 각각 6.6mg/L, 4.7mg/L로 87.2%, 91.3%의 제거효율을 보였다. T-P에 대한 RBC 단일공정과 RBC 연속공정에서의 분석 결과 유입수 평균농도는 각각 8.9mg/L, 9.1mg/L로 측정되었고, 유출수 농도는 1.6mg/L, 1.0mg/L로 T-P 제거율은 82%, 89%로 나타났다.

마산만의 자생 유기물 저감을 위한 단순 박스모델의 적용 (Reduction of Autochthonous Organics in Masan Bay using a Simple Box Model)

  • 홍석진;이원찬;윤상필;박성은;조윤식;권정노;김동명
    • 해양환경안전학회지
    • /
    • 제13권2호
    • /
    • pp.111-118
    • /
    • 2007
  • 단순 박스모델을 이용하여 $2005\sim2006$년 마산만의 담수 유량, 염분, 영양염, COD등 물질 수지를 산정하였다. 담수수지 계산 결과 계절별로 $307.4\times10^3\sim1,210\times10^3m^3/day$로 이 시기에는 5 월이 가장 높았다. 하천과 생활하수에 의한 DIP과 DIN의 유입flux는 각각 $410.8\sim795.7kg/day$$4081.4\sim6525.3kg/day$ 범위로 마산만 내부에서 질소의 축적이 예상된다. 순 기초생산(net primary production)은 연 평균 $0.028mol/m^2/day$$14.4\sim517.8mgC/m^2/day$의 범위로 분포하였으며, 평균 $330.7mgC/m^2/day$ 였다. 해저 퇴적물로부터의 영양염 공급을 100% 제거할 경우 COD 농도는 2.79mg/L 에서 2.20mg/L로 감소하여 COD의 21.0%의 제거 효과가 있는 것으로 나타났다.

  • PDF

하이브리드 빗물정원 시스템에서의 비점오염물질 및 강우유출수 이송 특성 (Transport of nonpoint source pollutants and stormwater runoff in a hybrid rain garden system)

  • ;;;;김이형
    • 한국습지학회지
    • /
    • 제18권4호
    • /
    • pp.481-487
    • /
    • 2016
  • 본 연구는 도시 강우유출수 처리를 위한 하이브리드 빗물정원 시스템을 개발하고자 수행되었으며, Pilot scale 모니터링을 통하여 시스템 내의 서로 다른 구성요소간의 효율을 검증하였다. 유입수는 국내 외 도로강우유출수의 농도를 고려한 인공강우유출수를 이용하여 수행하였다. 모니터링 결과 하이브리드 빗물정원은 시설 내 저류 80%, 지하수의 침투 15%로 유입수의 약 95% 저감되는 것으로 나타났다. 이는 ST의 저류 및 PB와 IT의 침투 기작이 물순환 효과에 기여한 것으로 판단된다. 또한 오염물질 저감효율을 산정한 결과, TSS의 경우 평균 87%으로 나타났으며, 유기물은76%, 영양염류는 46%, 중금속은 56%으로 나타났다. 이는 PB와 IT에 포함된 여재의 여과, 침투 및 식생과 토양의 생물학적 흡수 기작 영향에 의해 나타난 결과로 판단된다. 이러한 연구 결과는 향후 빗물정원의 효율을 향상시키기 위한 시설의 개선 및 설계방안으로 활용 가능할 것으로 평가된다.

표면개질 분리막을 이용한 단무지폐수 처리에 관한 연구 (A Study on the Treatment of Pickled Radish Wastewater Using Surface-modified Membrane)

  • 선용호
    • 유기물자원화
    • /
    • 제19권1호
    • /
    • pp.64-78
    • /
    • 2011
  • 본 연구에서는 염분이 높은 단무지폐수를 대상으로 새로운 침지형 막분리 장치를 제작하고 기존의 소수성이 강한 폴리에틸렌 재질의 비개질 분리막과 이 소수성 분리막에 이온빔을 조사하여 친수성을 높여준 표면개질 분리막을 사용한 성능실험에서 시간에 따른 플럭스(flux)와 압력 변화, 유기물과 부유물질, 영양염류 등 오염물질의 제거 특성을 알아보았다. 간헐식 비개질막을 사용한 실험 결과, 합성폐수와는 달리 실제폐수에서는 투과 압력이 급격히 증가하여 심한 파울링(fouling) 현상이 일어남을 알 수 있으며 이는 실제폐수에 존재하는 첨가제 등 고분자물질과 염분에 의한 영향으로 추정된다. 약품세정 후의 막과 물세정 후의 막의 압력과 플럭스 변화 실험에서 오염된 막을 재생하기 위해 약품세정이 반드시 필요하며 막 운전시 연속식보다는 간헐식으로 운전하는 것이 성능이 더 우수함을 알 수 있었다. 또한 개질막의 경우가 비개질막의 경우보다 파울링에 도달하는 시간이 약 6배가 크므로 개질막의 경우가 막의 교체 비용을 1/6로 줄일 수 있다. 표면개질 분리막과 비개질 분리막 모두 처리수는 대체로 양호한 수질을 나타내고 있으며 특히 SS 제거, 질소 및 인 제거에도 탁월한 성능을 나타내고 있다.

가축사육단지 강우유출수 처리목적 바이오 필터 여재로서 우드칩과 합성섬유의 평가 (Evaluation of Woodchip and Synthetic Fiber as Biofilter Media for the Treatment of Livestock Stormwater)

  • 청징;게라 하이디;김영철
    • 한국습지학회지
    • /
    • 제23권1호
    • /
    • pp.94-105
    • /
    • 2021
  • 본 연구에서는 합성섬유로 충진된 바이오필터(FBF)와 우드칩으로 충진된 필터(WBF)로 구성된 수직흐름형 습지공정(BFS)의 처리성능을 평가하였다. BFS 시스템에서 단독 필터를 사용한 것보다 두개의 필터를 직렬로 결합한 경우 특히 질소제거에 탁월한 성능을 나타내었다. FBF 공정에서는 암모니아 질소 100%가 활발한 질산화 반응을 통하여 질산성 질소로 전환되었으며 후속 WBF에서 77%의 질산성 질소가 제거되어 우드칩이 제공하는 탄소가 탈질반응에 큰 영향을 끼치는 것으로 판명되었다. 바이오필터의 성능은 유입특성에 상관없이 독립적인 성능을 보였으며 인 제거에도 효과가 있었으나 종종 용출징후가 나타났으며 현장적용시에는 이와 같은 사항을 유념해야할 것으로 보인다. 한편 회귀식 분석결과 운전시간에 따른 바이오 필터내부의 미생물 증식상태를 간접적으로 암시해 주었다. 본 연구결과 질소제거 측면에서 본 연구에서 제안하고 있는 여재를 이용한 수직흐름형 직렬식 습지 공정은 전형적인 수직-수평흐름 습지와 비교하여 비용측면에서 많은 장점을 가지고 있다.