• Title/Summary/Keyword: Organic loading rate

Search Result 280, Processing Time 0.018 seconds

Package of RBC/AFBR process for small-scale Piggery Wastewater Treatment (소규모 축산폐수 처리를 위한 RBC/AFBR공정의 Package화)

  • 임재명;권재혁;류재근
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.2
    • /
    • pp.43-52
    • /
    • 1996
  • Using rotating biological contactor(RBC) with artificial endogenous stage and aerobic fixed biofilm reactor(AFBR), organic material removal and biological nitrification of piggery wastewater has been studied at a pilot plant. RBC was operated in the endogenous phase at a interval of every 25 days. The concentration of COD, BOD and TKN in influent wastewater were from 2,940 to 3,800 mg/L, from 1,190 to 1,850 mg/L and from 486 to 754 mg/L respectively. The maximum active biomass content represented as VSS per unit aera was $2.0mg/cm$^{2}$ and biofilm dry density of $17mg/cm^{3}$ was observed at biofilm thickness of $900{\;}{\mu}m$. It was observed that the pilot scale RBC/AFBR process exhibited 72 percentage to 93 percentage of BOD removal, In order to obtain more than 90 percentage of BOD removal, the organic loading rate to the RBC/AFBR process should be maintained less than $0.09{\;}m^{3}/m^{2}{\cdot}day(125.9g{;\}BOD/m^{3}{\cdot}d$. The TKN removal efficiencies was from 45.5 to 90.9 percentage according to vary influent loading rate, It was estimated that the RBC/AFBR process consumed approximately 6.2 mg/L(as $CaCO_{3}$) of alkalinity per 1 mg/L of $NH_{3}$-N oxidized as the nitrification took piace.

  • PDF

The Basic Design Parameters and Effluent Characteristics for Aerobic Fixed Biofilm Reactor (호기성 고정생물막 반응기에서 기초 설계인자와 유출수의 성상)

  • 박태주;송승구
    • KSBB Journal
    • /
    • v.7 no.3
    • /
    • pp.235-245
    • /
    • 1992
  • A number of experiments to treat wastewater of a dye plant were conducted to investigate the basic design parameters and effluent characteristics for aerobic fixed biofilm reactor upon the variation of organic loading rate. The media used for this study were SARAN 4000 D with specific surface area $153m^2/m^3$, and 1000 D with specific surface area $307m^2/m^3$. The influent COD concentration ranged from 1250 to 4080 mg/L. Substrate removal and variation of biomass concentration were observed. At the beginning, the effluent quality was poor but improved as the time passed. However the effluent quality became seriously deteriorated when the media clogged. At influent COD of 1250mg/L, the effluent COD varied little, even if the organic loading rate increased from 0.63 to 2.5kg COD/$m^3$/day. It was also noted that the design parameters for activated sludge process could be applied to an aerobic fixed biofilm process under the experimental conditions.

  • PDF

Application of a Membrane Bioreactor in Denitrification of Explosives Hydrolysates (Membrane Bioreactor를 이용한 폭발성 물질의 가수분해 부산물의 탈질과정에의 적용)

  • Zoh, Kyung-Duk
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.2
    • /
    • pp.113-122
    • /
    • 2002
  • A bench-scale anoxic membrane bioreactor (MBR) system, consisting of a bioreactor coupled to a ceramic crossflow ultrafiltration module, was evaluated to treat a synthetic wastewater containing alkaline hydrolysis byproducts (hydrolysates) of RDX, The wastewater was formulated the same as RDX hydrolysates, and consisted of acetate, formate, formaldehyde as carbon sources and nitrite, nitrate as electron accepters. The MBR system removed 80 to 90% of these carbon sources, and approximately 90% of the stoichiometric amount of nitrate, 60% of nitrite. The reactor was also operated over a range of transmembrane pressures, temperatures, suspended solids concentration, and organic loading rate in order to maximize treatment efficiency and permeate flux. Increasing transmembrane pressure and temperature did not improve membrane flux significantly. Increasing biomass concentration in the bioreactor decreased the permeate flux significantly. The maximum volumetric organic loading rate was $0.72kg\;COD/m^3/day$, and the maximum F/M ratio was 0.50 kg N/kg MLSS/day and 1.82 kg COD/kg MLSS/day. Membrane permeate was clear and essentially free of bacteria, as indicated by heterotrophic plate count. Permeate flux ranged between 0.15 and $2.0m^3/m^2/day$ and was maintained by routine backwashing every 3 to 4 day. Backwashing with 2% NaOCl solution every fourth or fifth backwashing cycle was able to restore membrane flux to its original value.

TREATMENT OF HIGH-CONCENTRATION SWINE WASTEWATER BY ANAEROBIC DIGESTION AND AN AQUATIC PLANT SYSTEM

  • Kim, B.U.;Kwon, J.H.
    • Environmental Engineering Research
    • /
    • v.11 no.3
    • /
    • pp.134-142
    • /
    • 2006
  • The treatment of high-strength swine wastewater by anaerobic digestion combined with an aquatic plant system was investigated. Anaerobic digestion of swine wastewater gave volatile solids (VS) removal efficiencies of 43.3%, 52.1% and 54.5% for hydraulic retention times (HRTs) of 20, 30, 40 days, respectively. The removal efficiencies of VS, total chemical oxygen demand (TCOD) and soluble chemical oxygen demand (SCOD) decreased with increasing VS volumetric loading rate (VLR). Higher organic removal efficiency was observed at longer HRTs for the same VS volumetric loading rate. As VS volumetric loading rate increased, biogas production increased and the methane content of the biogas decreased. Experiments using duckweed (Lemna species) as an aquatic macrophyte gave the following results. In the case of nitrogen, removal efficiency was above 60% and effluent concentration was below 10.0 mg/L when the influent ammonia-N loading was about $1.0\;g/m^2/day$. In the case of phosphorus, removal efficiency was above 55% and effluent concentration was below 2.0 mg/L when the influent $PO_4$-P loading was about $0.15\;g/m^2/day$. In addition, crude protein and phosphorus content of duckweed biomass increased from 15.6% to 41.6% and from 0.8% to 1.6%, respectively, as the influent nutrient concentration increased. The treatment of high-strength swine wastewater by anaerobic digestion combined with an aquatic plant system offers good performance in terms of organics and nutrient removal for relatively low operation and maintenance costs. The results indicate that under appropriate operational conditions, the effluent quality is within the limits set by Korean discharge criteria.

Prediction of the Concentration Decay of Volatile Organic Compounds under Different Air Change Rates and Loading Factor Conditions (환기회수 및 부하율 변화에 따른 휘발성유기화합물 농도 감쇠 예측에 관한 연구)

  • Pang Seung-Ki;Sohn Jang-Yeul;Ahn Byung-Wook
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.6
    • /
    • pp.505-513
    • /
    • 2005
  • We measured the time-dependent concentration of VOCs emitted from Ondol floor, furniture, and the wall made of various building materials. After obtaining results from the previous measurement, we developed the estimation equations of the concentration decay, and obtained the estimated graphs for the concentration decay under different air change rates and loading factor conditions by using the estimated equations. We conducted our tests by applying our measurements to real residences for 110 days in the case of furniture and for 40 days in the case of the floor. We also conducted experiments in the cases of various wall materials for 7 days which totaled 10 times. We used the GC/FID for experiments for real residences accord-ing to the specified procedures of the NIOSH 1501, and carried out experiments for wall materials according to the specified procedures of the ASTM 5116-97. When conducting experiments for wall materials, we set the temperature and relative humidity at $23^{\circ}C$ and $50\%$, respectively. We also set the air change rate and loading factor at 0.7/h and $1.617 m^2/m^3$, respectively. Our results showed that it is possible to predict proplrly the time-dependent concentration decay of VOCs by using logarithmic functions in both cases of experiments for real residences and for wall materials. Furthermore, we found that the concentration decay rate of VOCs increased rapidly as the air exchange rate increased while the concentration decay rate decreased as the loading factor increased.

Performance Enhancement of Anaerobic Treatment of Waste Sludge by Chemical Pretreatment (화학적 전처리를 통한 혐기성 슬러지 처리효율의 향상)

  • 허준무;박종안;손부순
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.1
    • /
    • pp.16-25
    • /
    • 1998
  • Laboratory-scale experiment using anaerobic fluidized bed reactor was carried out to investigate the prehydrolysis step with caustic soda on the treatment efficiency of anaerobic sludge treatment, since the overall rate-limiting step for the complete anaerobic digestion of sludge was the hydrolysis step by extracellular bacterial enzymes of insoluble polymeric molecules. Reactors received a sludge which had not been pretreated, a 50-50 mixture of pretreated and untreated sludge, and the fully pretreated sludge. Hydraulic retention time of 10, 5, 2.5 days and 1 day were applied with an respective equivalent organic loading rate of 1.17, 2.23, 4.17, 11.24 gCOD/L/d. Reactor with the untreated sludge did not archieve adequate digestion even at the HRT of 5 days, and reactor, which received the 50-50 mixture, operated well at the HRT of 5 days, but began to show signs of unstable digestion at the HRT of 2.5 days. While, reactor, which was fed the hydrolyzed sludge, operated reasonably well at the 2.5 days, but was showing somewhat decrease in removal efficiencies. Results, therefore, have substantiated that the limiting reaction in the anaerobic treatment process is hydrolysis. The soluble COD did not significantly accumulate in the reactor as organic acid form, even when they were highly stressed. It was believed that this resistance to a build-up of organic acids and soluble COD behavior was mainly due to the maintenance of the methane bacteria in the fixed-film system which prevents washout as the organic loading increased. The anaerobic fluidized bed reactor was therefore effective for the digestion of waste activated sludge at short HRT.

  • PDF

Performance Evaluation of Biofilter Treating Autothermal Thermophilic Aerobic Digestion Offgas (고온호기성 소화공정 배가스 처리를 위한 바이오필터 성능평가)

  • Bae, Byung-Uk;Choi, Ki-Seung
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.732-739
    • /
    • 2010
  • Two combined autothermal thermophilic aerobic digestion (ATAD) and biofilter (BF) systems were operated to treat the piggery wastewater and the ammonia offgas. Experimental results indicated that the organic removal efficiency of ATAD-2, operated with oxygen, was higher than that of ATAD-1, operated with air. The concentration of ammonia in ATAD-2 offgas was higher compared to ATAD-1 offgas, but the total amount of ammonia produced from ATAD-2 was less than that from ATAD-1 due to the lower oxygen flowrate. The ammonia gas produced from both ATAD reactors was successfully removed by the BF. The BF-1, connected with ATAD-1, removed 93% of ammonia at the loading rate of $9.4g\;NH_3-N/m^3/hr$. The BF-2, connected with ATAD-2, removed 95% of ammonia gas at the loading rate of $8.1g\;NH_3-N/m^3/hr$. As the nitrification process continued, pH value of recirculating solution continuously decreased due to the accumulation of nitrate. When the ammonia loading rate was less than $22.7g\;NH_3-N/m^3/h$, the proper replacing cycle of recirculating solution was in the range of 10 to 11 days. Almost 90% of total mass of nitrogen fed into the each BF was confirmed from the mass balance on nitrogen.

Removal of Organic and Nutrients in Fish Market Wastewater using Sequencing Batch Reactor (SBR) (SBR공정을 이용한 수산물 위판장 폐수에서 유기물 및 질소 제거)

  • Kim, Sung-Ju;Lee, Dae-Hee;Park, Hung-Suck
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.1
    • /
    • pp.46-51
    • /
    • 2007
  • This research work aims at treating saline wastewater generated from a fish market using four Sequencing Batch Reactors (SBR) operated under different conditions. The effect of C/N ratio (3, 6) and salt concentration (0.5~2%) on organic and nitrogen removal was studied. The synthetic wastewater prepared with glucose ($C_6H_{12}O_6$) as the primary carbon source along with ammonium chloride ($NH_4Cl$) was used in the three reactors. The fill, anoxic, aeration, settle and draw conditions were 2 hr, 4 hr, 4 hr and 2 hr respectively. The fourth reactor was operated at different conditions to investigate the practical feasibility of SBR application to handle fish market wastewater generated in Ulsan city that had fluctuating loading characteristics. Though the unacclimated sludge was initially affected by the salt concentration, the acclimated sludge removed 95% of the organics irrespective of the NaCl concentration and C/N ratio. However, the removal of nitrogen was affected more by C/N ratio than the salt concentration. While handling fish market wastewater, though the organic and nitrogen loading rate were varying between $0.009{\sim}0.259gCOD_{OH}/gVSS/day$ and 0.005~0.034 gN/gVSS/day, the effluent concentrations were far less than the effluent standard of $120mgCOD_{OH}/L$ and 60 mgN/L respectively, except when loading rates were fluctuating and 4 times higher than the average.

Anaerobic Digestion of Pig Manure and Night Soil Mixed Waste in a Normal Temperature (I) (常溫에서 豚 . 人糞混合廢棄物의 嫌氣性處理(I))

  • Kim, Nam-Cheon;Min, Dal-Ki
    • Journal of Environmental Health Sciences
    • /
    • v.14 no.1
    • /
    • pp.63-71
    • /
    • 1988
  • This study is an experimental research on the anaerobic digestion of pig manure and night soil mixed waste at room temperature (25$\circ$C), and the results are shown below: 1. The steady-state condition based on gas production as digestion temperature dropped to 25$\circ$C from 35$\circ$C was achieved at around 28, 47, 56, 64 days respectively when its hydraulic retention time(HRT) are 10, 20, 30, 40 days. 2, Alkalinity and volatile acid(VA) was increased as increasing the organic loading. 3. Removal efficiency of chemical oxygen demand(COD) and biochemical oxygen demand (BOD) was improved as longer HRT, and generally COD value is lower and BOD value is higher relatively. 4. Overall treatment efficiencies of mixed waste are higher than of pig manure and of night soft. 5. Organic removal efficiency at room temperature (25$\circ$C) is 20-25% lower at medium temperature (35$\circ$C) in a same VS loading condition. 6. Refractory fraction of the infiuent VS and organic removal rate constant(K) estimated at around 37% and 0.107/day respectively.

  • PDF

Effect of Ammonia Nitrogen Loading Rate on the Anaerobic Digestion of Slurry-typed Swine Wastewater (슬러리형 돈사폐수의 혐기성 소화시 암모니아 부하의 영향)

  • Won, Chul-Hee;Kwon, Jay-Hyouk;Rim, Jay-Myoung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.1
    • /
    • pp.49-57
    • /
    • 2009
  • This research examined the effect of ammonia nitrogen loading rate(NVLR) on the anaerobic digestion of slurry-typed swine wastewater. The anaerobic reactor was used an upflow anaerobic sludge blanket (UASB) process. This UASB reactor was operated at a NVLR of $0.02{\sim}0.96kg{NH_4}^+-N/m^3/day$. The methane content showed the range of 73.3~77.9% during the steady state period. Free ammonia(FA) concentration increased over inhibition level as pH increase from 7.3 to 8.2. However, in consideration of methane content, methane producing bacteria (MPB) inhibition by FA and total ammonia(TA) was not observed. A stepwise increase of the NVLR resulted in a deterioration in the COD removal rate in UASB reactor. The COD removal rate were 60% for NVLR up to $0.55kg{NH_4}^+-N/m^3/day$. As the NVLR increased from 0.09 to $0.96kg{NH_4}^+-N/m^3/day$, the biogas production rate varied from 3.71 to 9.14L/d and the methane conversion rate of the COD varied from 0.32 to $0.20m^3CH_4/kg$ COD removed. Consequently, in considerations of FA concentration, COD removal rate, and $CH_4$ production rate, the UASB reactor must be operated to lower than $0.40kg{NH_4}^+-N/m^3/day$ of NVLR.