• Title/Summary/Keyword: Organic loading

Search Result 531, Processing Time 0.03 seconds

Runoff Characteristics of Refractory Organic Matters from Han River Basin during Dry Days (비강우시 한강수계 하천의 연간 난분해성 물질 유출특성)

  • Heo, Sanghoi;Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.19 no.3
    • /
    • pp.353-358
    • /
    • 2017
  • As a drinking water source of 26 millions people of Seoul metropolitan region, Han river is one of the most important basin. Managing the Non-point source pollution which is regarded as the main cause of water pollution including refractory organic matter is important thing. This research investigates the runoff characteristics of organic matters from main 3 rivers (South Han, North Han, Kyungan). Water quality measurement items include not only carbon-based TOC (Total Organic Carbon), DOC (Dissolved Organic Carbon), POC (Particulate Organic Carbon) but also R-TOC (Refractory Total Organic Carbon), R-DOC (Refractory Dissolved Organic Carbon), R-POC (Refractory Particulate Organic Carbon) is researched. The research shows that R-TOC takes approximately 61~83% of TOC. Most of the R-TOC is consist of R-DOC (72~77%). Refractory organic matter have a stable runoff characteristics compared to other organic matter. The organic matter concentrations of South Han river and Kyungan river are the highest in spring time and show a gradual decline. The concentrations of Kyunan river is the highest. Kyungan river's small area and the high city land use ratio seem to be the reason. Loading of organic matter in summer time takes the most loading (62~84%). TOC loadings per unit area of each river is Kyungan river ($1.22ton/km^2$), South Han river ($1.01ton/km^2$), North Han river ($0.91ton/km^2$).

Water Purification Characteristics of Sedimentation Basin for Agricultural Water Quality Improvement (농업용수 수질개선을 위한 침강지의 수질정화 특성)

  • Kim, Hyungjoong;Kim, Donghwan
    • KCID journal
    • /
    • v.21 no.1
    • /
    • pp.55-63
    • /
    • 2014
  • A sedimentation basin for agricultural water quality improvement was researched to analyze the water quality purification characteristics. The sedimentation basin constructed at the inlet of Gamdon reservoir in Muan-gun, Jeollanam-do was selected as the research field of this study. The surface area of the sedimentation basin is $34,000m^2$, volume is $122,000m^3$, and hydraulic retention time is 0.3hr~7.3day. The average influent loading of SS was 156.6kg-SS/d, and the effluent loading was 67.5kg-SS/d with the average removal rate of 56.9%. The average influent loadings of BOD and COD were 33.0kg-BOD/d and 60.3kg-COD/d respectively, and the effluent loadings were 26.4kg-BOD/d and 48.6kg-COD/d with the average removal rate of 20.1% and 19.3% respectively. Therefore, the results of this study show that a sedimentation basin can purify SS and organic matters. The average influent loadings of T-N and T-P were 28.7kg-TN/d and 2.97kg-TP/d respectively, and the effluent loadings were 16.3kg-TN/d and 1.41kg-TP/d with the average removal rate of 43.0% and 52.6% respectively. In conclusion, the overall results of this study show that a sedimentation basin is a feasible alternative to purify organic matters and nutrients.

  • PDF

Anaerobic Digestion of Pig Manure and Night Soil Mixed Waste in a Normal Temperature (I) (常溫에서 豚 . 人糞混合廢棄物의 嫌氣性處理(I))

  • Kim, Nam-Cheon;Min, Dal-Ki
    • Journal of Environmental Health Sciences
    • /
    • v.14 no.1
    • /
    • pp.63-71
    • /
    • 1988
  • This study is an experimental research on the anaerobic digestion of pig manure and night soil mixed waste at room temperature (25$\circ$C), and the results are shown below: 1. The steady-state condition based on gas production as digestion temperature dropped to 25$\circ$C from 35$\circ$C was achieved at around 28, 47, 56, 64 days respectively when its hydraulic retention time(HRT) are 10, 20, 30, 40 days. 2, Alkalinity and volatile acid(VA) was increased as increasing the organic loading. 3. Removal efficiency of chemical oxygen demand(COD) and biochemical oxygen demand (BOD) was improved as longer HRT, and generally COD value is lower and BOD value is higher relatively. 4. Overall treatment efficiencies of mixed waste are higher than of pig manure and of night soft. 5. Organic removal efficiency at room temperature (25$\circ$C) is 20-25% lower at medium temperature (35$\circ$C) in a same VS loading condition. 6. Refractory fraction of the infiuent VS and organic removal rate constant(K) estimated at around 37% and 0.107/day respectively.

  • PDF

Anaerobic digestion of food waste to methane at various organic loading rates (OLRs) and hydraulic retention times (HRTs): Thermophilic vs. mesophilic regimes

  • Kumar, Gopalakrishnan;Sivagurunathan, Periyasamy;Park, Jong-Hun;Kim, Sang-Hyoun
    • Environmental Engineering Research
    • /
    • v.21 no.1
    • /
    • pp.69-73
    • /
    • 2016
  • Generation of food waste is a serious issue that needs to be addressed worldwide. Developing suitable treatment methods while generating energy (methane) is a common practice for sustainable treatment of waste. In this study, methane generation by food waste was investigated in mesophilic and thermophilic regimes at various hydraulic retention times (HRTs) and organic loading rates (OLR). In temperature regimes, influent concentrations and HRTs ranged from 30 to 110 g COD/L and 18 to 30 days, respectively, which corresponding to an OLR of 1.0 to $6.1kg\;COD/m^3-d$. Better methane production and organic removal was observed under thermophilic conditions because of the enhanced hydrolysis of complex polymers and microbial activity at higher temperature. The peak methane productivities attained in thermophilic and mesophilic regimes were 1.30 and $0.99m^3/m^3-d$, respectively. The maximum methane yields were achieved at 50 g COD/L and HRT of 24 d in both cases, and the values were 264 and $221m^3/ton$ COD, respectively. The results of this study will facilitate the development of sustainable methane production technologies using food waste as a feedstock.

Sewage Treatment using Moving Media Complete Mixing Activated Sludge/Solid Contact Process (회전매체를 가진 완전혼합 활성슬러지/Solid Contact 공법을 이용한 하수처리에 관한 연구)

  • 김홍태
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.35 no.4
    • /
    • pp.67-75
    • /
    • 1993
  • This study was carried out to investigate the applicability of Solid Contact Process for the improvement of Moving Media Complete Mixing Activated Sludge(MMCMAS) effluents. Laboratory MMCMAS Reactor and MMCMAS/Solid Contact were operated at the hydraulic loading of 122~340 L/m$^2$/d. The conclusions from this study were as follows ; The addition of Solid Contact tank to the MMCMAS reactor has increased the SCOD and SBOD removal efficiencies of 4 to 67% and 2 to 41%, respectively. In addition, the increments of nitrification rates were about 13 to 46%. It was also observed that the addition of Solid Contact tank has greatly increased the organic removal efficiencies at the higher hydraulic loading rates and also decrement of sludge production rates was 0.1 gVSS/gBODrem. It was therefore concluded that the addition of Solid Contact tank could have polished the effluent of MMCMAS at the higher hydraulic loading rates.

  • PDF

Mixing effect on organic removal efficiency in treating low-strength wastewater using a modified anaerobic filter reactor (변형 혐기성 여상 반응조에서 교반강도가 유기물 제거효율에 미치는 영향)

  • 정병곤;이헌모
    • Journal of Environmental Science International
    • /
    • v.5 no.4
    • /
    • pp.513-524
    • /
    • 1996
  • Laboratory investigation was conducted to evaluat the mixing effects on organic removal efficiency to treat low-strength synthetic wastewater using modified anaerobic - filter reactor combining anaerobic filter and upflow anaerobic sludge blanket. Using the modified process the low-strength wastewater like municipal sewage could be treated with 85% T-COD removal efficiency at hydraulic retention time of 6 hours. At the constant organic loading of 0.5 kg COD/m 3-day, the organic removal efficiency and effluent COD concentration are increased as influent COD concentration increased from 125 mg/l to 500 mg/l. Mixing effects on organic removal efficiency are evident and optimum mixing speed is found as 50RPM. Placing the granular sludge and media on which slime layer was pre-formed into the reactor seemed to be very effective In achieving short start-up period. Therefore, the steady state was achived after 4 weeks and 1 week based on T-COD and S-COD, respectively.

  • PDF

Integrated System of RBC-lime Precipiatation for Simultaneous Removal of Organics and Nutrients (회전원판공정과 화학침전공정 조합을 이용한 유기물과 질소*인의 동시제거)

  • 박종안;허준무;손부순
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.1
    • /
    • pp.132-140
    • /
    • 1998
  • Laboratory-scale experiments were conducted using a three-stage rotating biological contactor unit followed by lime precipitation and sedimentation with effluent recycle to the first stage. The purpose of this study was to evaluate the effects of hydraulic loadings of 0.031-0.076 $m^3/m^2/d and recycle ratio of 1 to 3 on the simultaneous removal of organics and nutrients from domestic wastewater. Lime was added to maintain pH of 10.4-11.0 in the coagulation-flocculation reactor. Results showed that the highest nitrogen removal rate of 70.5% occurred at the lower hydraulic loading of 0.031 $m^3/m^2/d at a recirculation rate of 300%, and similarly, highest nitrification occurred at the same hydraulic loading and recycle ratio. Concentration of ammonia nitrogen in the effluent was less than 1 mg/l at the same operating conditions for higher nitrogen removal. Whereas, high BOD and COD removal was observed at hydraulic loading rate of 0.054 $m^3/m^2/d, and high removal of organic matter was evident from the consistent low COD and BOD value. Results obtained from the operating condition of higher loading rate, 300% of recycle rate showed the highest removals. Increasing in recycle rate and hydraulic loading rate increased the volatile solids fraction of the sludges generated to the extent of 47% at 0.076 $m^3/m^2/d hydraulic loading and 300% recirculation rate. Since pH in the flocculator was maintained at the pH of 10.4-11.0, above 90% removal of phosphorus was obtained. Average concentration of suspended solids was always maintained over 40 mg/l in the effluent. Therefore an RBC unit operating at a hydraulic loading near 0.031 $m^3/m^2/d with a recycle rate of 300% is a viable and feasible alternate conditions to produce an effluent with relative low organic matter and phosphorus, provided that there is a neutralization unit to control the pH and SS of the effluent.

  • PDF

Characteristics of $NH_3$-N removal in nitrification reactor according to organic loading rate (질산화 반응조에서 유기물 부하에 따른 암모니아 제거 특성)

  • Kang, Min-Koo;Kim, Keum-Yong;Kim, Seung-Ha;Ryu, Hong-Duck;Lee, Sang-Ill
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.3
    • /
    • pp.7-15
    • /
    • 2009
  • The objective of this study was to investigate difference in nitrogen, organic, phosphorus and $NH_3$-N removal efficiency according to organic loading, comparing M-DEPHANOX process which has two nitrification reactor with M-eBNR process which has one nitrification reactor. As a result of this study, $NH_3$-N removal efficiency of M-DEPHANOX and M-eBNR resulted in average level of 91.8%, 96.9%, respectively. M-DEPHANOX and M-eBNR processes showed high removal efficiency in view of $NH_3$-N removal efficiency. Comparing organic removal efficiency by M-DEPHANOX and M-eBNR processes, the average removal efficiency in terms of TCOD, SCOD was 84.1%, 78.2% and 83.4%, 75.6%. Also, the results that observed about $NH_3$-N removal efficiency regarding organic loading revealed that nitrification reactor of RBC type are little influenced by flowing organic without precipitating at settling tank. Therefore, although inflow characteristics of municipal wastewater changes, M-eBNR process appeared to remove $NH_3$-N reliably.

Improved Organic Removal Efficiency in Two-phase Anaerobic Reactor with Submerged Microfiltration System (침지형 정밀여과시스템을 결합한 이상 혐기성 시스템에 의한 유기물 제거율의 향상)

  • Jung, Jin-Young;Chung, Yun-Chul;Lee, Sang-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.629-637
    • /
    • 2000
  • A two-phase anaerobic reactor with a submerged microfiltration system was tested for its ability to produce methane energy from organic wastewater. A membrane separation system with periodic backwashing with compressed air was submerged in the acidogenic reactor. The cartridge type of microfiltration (MF) membrane with pore size of $0.5{\mu}m$ (mixed esters of cellulose) was tested. An AUBF (Anaerobic Upflow Sludge Bed Filter: 1/2 packed with plastic media) was used for the methanogenic reactor. Soluble starch was used as a substrate. The COD removal was investigated for various organic loading with synthetic wastewater of 5,000 mg starch/L. When the hydraulic retention time (HRT) of the acidogenic reactor was changed from 10 to 4.5 days, the organic loading rate (OLR) varied from 0.5 to $1.0kg\;COD/m^3-day$. When the HRT of the methanogenic reactor was changed from 2.8 to 0.5 days, the OLR varied from 0.8 to $5.8kg\;COD/m^3-day$. The acid conversion rate of the acidogenic reactor was over 80% in the 4~5 days of HRT. The overall COD removal efficiency of the methanogenic reactor showed over 95% (effluent COD was below 300 mg/L) under the highly fluctuating organic loading condition. A two-phase anaerobic reactor showed an excellent acid conversion rate from organic wastewater due to the higher biomass concentration than the conventional system. A methanogenic reactor combined with sludge bed and filter, showed an efficient COD and SS removal.

  • PDF

Instrumentation of a Thermal-Optical Carbon Analyzer and Its Sensitivity in Organic and Elemental Carbon Determination to Analysis Protocols

  • Lim, Ho-Jin;Sung, Su-Hwan;Yi, Sung-Sin;Park, Jun-Hyun
    • Journal of Environmental Science International
    • /
    • v.21 no.1
    • /
    • pp.1-9
    • /
    • 2012
  • A thermal-optical transmittance carbon analyzer has been developed to determine particulate organic (OC) and elemental (EC) carbon. Several analysis factors affecting the sensitivity of OC and EC determination were investigated for the carbon analyzer. Although total carbon (TC) is usually consistent in the determination, OC and EC split is sensitive to adopted analysis protocol. In this study the maximum temperature in oxygen-free He in the analysis was examined as a main cause of the uncertainty. Prior to the sensitivity analysis consistency in OC-EC determination of the carbon analyzer and the uniformity of carbonaceous aerosol loading on a sampled filter were checked to be in acceptable range. EC/TC ratios were slightly decreased with increasing the maximum temperature between $550-800^{\circ}C$. For the increase of maximum temperature from $500^{\circ}C$ to $800^{\circ}C$, the EC/TC ratio was lowered by 4.65-5.61% for TC loading of 13-44 ${\mu}g/cm^2$ with more decrease at higher loading. OC and EC determination was not influenced by trace amount of oxygen in pure He (>99.999%), which is typically used in OC and EC analysis. The facing of sample loaded surface to incident laser beam showed negligible influence in the OC-EC split, but it caused elevated PC fraction in OC for forward facing relative to backward facing.