• 제목/요약/키워드: Organic loading

검색결과 531건 처리시간 0.034초

음식물쓰레기의 유기물 부하 및 식종율 변화가 생분해도에 미치는 영향 (The Effect of Organic Loading and Seeding Rate to Biodegradibility of Food Waste)

  • 박남배;정용현;양병수
    • 환경위생공학
    • /
    • 제14권2호
    • /
    • pp.25-31
    • /
    • 1999
  • Energy recovery technology from municipal solid waste has been increasingly established in many countries. Anaerobic treatment of municipal sewage sludge has low digestion efficiency because of low organic loading rate of sewage sludge. The purpose of this study was to evaluate anaerobic biodegradability of food waste which was based on organic loading rate and seeding rate. From the results of anaerbic biodegration, the optimum condition for seeding rate was turn out over 40%, which did not inhibition of methane production.

  • PDF

전해부상을 고액분리 방법으로 적용한 SBR 공정의 운전 특성 (Operation Characteristics of the SBR Process with Electro-Flotation (EF) as Solids-liquid Separation Method)

  • 박민정;최영균
    • 한국물환경학회지
    • /
    • 제24권3호
    • /
    • pp.340-344
    • /
    • 2008
  • Electro-flotation (EF) was applied to a sequencing batch reactor process (SBR) in order to enhance solids-liquid separation. Solids-liquid separation was good enough in the SBR coupled with EF (EF-SBR) and it was possible to maintain the concentration of mixed liquor suspended solids (MLSS) high in the EF-SBR. Under moderate organic loading condition (COD loading rate: 6 g/day), control SBR (C-SBR) showed similar treatment efficiencies with the EF-SBR. Under high organic loading condition (COD loading rate: 9.6 g/day), the solids-liquid separation in the C-SBR was deteriorated due to proliferation of filamentous bulking organisms at high F/M ratio. However, the EF-SBR was operated stably and with the high MLSS concentration (above 4,000 mg/L) regardless of the organic loading conditions during overall operating period leading to the satisfactory effluent quality. Gas production rate of the electrodes was gradually decreased because of anodic corrosion and scale build-up at the surface of cathode. However it could be partially overcome by use of corrosion-proof electrode material (SUS-316 L) and by periodic current switching between the electrodes.

Influence of Physical Load on the Stability of Organic Solar Cells with Polymer : Fullerene Bulk Heterojunction Nanolayers

  • Lee, Sooyong;Kim, Hwajeong;Kim, Youngkyoo
    • Current Photovoltaic Research
    • /
    • 제4권2호
    • /
    • pp.48-53
    • /
    • 2016
  • We report the effect of physical load on the stability of organic solar cells under physical loads. The active layers in organic solar cells were fabricated with bulk heterojunction films (BHJ) films of poly (3-hexylthiophene) and phenyl-$C_{61}$-butyric methyl ester. The loading time was varied up to 60 s by keeping the physical load constant. Results showed that the open circuit voltage was not influenced by the physical load but other solar cell parameters were sensitive to the loading time. The fill factor was very slightly increased at 15 s, while short circuit current density was well kept for 30 s. The power conversion efficiency was reasonably maintained for 45 s but became significantly decreased by the continuous loading for 60 s.

고부하 유기성 폐수처리를 위한 분리막 결합형 순산소 고효율 포기장치의 총괄 산소전달효율 평가 (Comparison of Overall Oxygen Transfer Coefficient in the Membrane Coupled High Performance Reactor for a High Organic Loading Wastewater Treatment)

  • 강범희;임경호;이상민
    • 한국물환경학회지
    • /
    • 제26권1호
    • /
    • pp.81-88
    • /
    • 2010
  • This study was conducted to find the capability of comparison of overall oxygen transfer coefficient in the membrane coupled high performance reactor (MPHCR) in treating high organic loading wastewater. Effluent quality had been analyzed while the influent organic loading rate was changed from 2 to $7kg\;COD/m^3{\cdot}day$. The oxygen transfer coefficients had been investigated using two-phase nozzle for operating variables which were internal circulation flowrate (5~8 L/min), air flow rate (0.0125~0.2 L/min), liquid temperature ($10{\sim}20^{\circ}C$), and pure-oxygen flow rate (0.0125~0.2 L/min). The overall oxygen transfer coefficient was increased with flowrate of internal circulation and air and high temperature. Especially, internal circulation flow rate showed distinct effect on overall oxygen transfer coefficient due to an increase of gas holdup and air-liquid contract area by two-phase nozzle. In the high range of organic loading rate from 4 to $7kg\;COD/m^3{\cdot}day$, the removable efficiency of COD was 91%. Conventional activated sludge process usually treat organic loading from 0.32 to $0.64kg\;COD/m^3{\cdot}day$ however, the MPHCR can treat 10 to 20 times higher if it would be compared to the conventional activated sludge process. Foaming problem often happened and caused biomass wash out of the reactor, therefore, the foaming should be controlled for the enhanced operation.

ASBR(Anaerobic Sequencing Batch Reactor) 공정의 F/R비가 암모니아가 탈기된 축산폐수의 유기물 제거에 미치는 영향 (Effect of F/R ratio of ASBR (Anaerobic Sequencing Batch Reactor) Process on Removal of the Organic Matters in Ammonia Stripped Swine Wastewater)

  • 황규대;조영무
    • 한국물환경학회지
    • /
    • 제21권6호
    • /
    • pp.687-694
    • /
    • 2005
  • Lab-scale experiments have been carried out to investigate the effect of F/R ratio of ASBR (Anaerobic Sequencing Batch Reactor) process on the removal of the organic matters in ammonia stripped swine wastewater. Three ASBR inoculated with sludge mixed with granular sludge of UASB (Upflow Anaerobic Sludge Blanket) and anaerobic digested sludge of municipal wastewater treatment plant were operated. Ammonia stripped swine wastewater was used as influent. Prior to conducting the experiments with varied conditions, the effect of increasing organic loading rate from 2.34 to $5.79gTCOD_{Cr}/L$-day at a fixed F/R ratio of 0.1 on the organic removal efficiency has been studied during start-up period. As the result of the experiment, under the condition of varied organic loadings, less than $4.14gTCOD_{Cr}/L$-day, the removed efficiency $TCOD_{Cr}$ of the ASBR process is 83% resulted from the mean value of effluent $TCOD_{Cr}$, 9,125 mg/L during the start-up period. Then ASBRs were operated with F/R ratio of 0.024, 0.303 and 0.91 respectively. Organic loading rate was increased from 4.56 to $15.43gTCOD_{Cr}/L$-day to investigate the effects of F/R ratio and organic loading rate on the organic removal efficiency. As the result of the experiment, less than $6.23gTCOD_{Cr}/L$/L-day, F/R ratio haven't an effect on the organic removal efficiency and the mean removal efficiency of TSS, $TCOD_{Cr}$ and $SCOD_{Cr}$ was about 80%, 86% and 78% at the all of F/R ratio. But as organic loading rate was increased from 8.54 to $12.04gTCOD_{Cr}/L$-day at the F/R ratio of 0.024, the removal efficiency of $SCOD_{Cr}$ decreased from 71% to 63%. The range of decreased removal efficiency of $SCOD_{Cr}$ at the F/R ratio of 0.024 was much more higher than at the F/R ratio of 0.303, 0.91. Thus, as organic loading rate was increased, ASBRs were operated with high F/R ratio to obtain high removal efficiency.

반응조 형태 및 슬러지층 유동화 특성에 따른 Upflow Anaerobic Sludge Blanket (UASB) 반응조의 운전효율 (Performance of Upflow Anaerobic Sludge Blanket (UASB) Reactor Depending on Reactor Configuration and Sludge Bed Fluidization)

  • 정병곤
    • 한국환경보건학회지
    • /
    • 제32권2호
    • /
    • pp.179-185
    • /
    • 2006
  • Effect of organic loading rate on UASB performance was evaluated under the renditions of some surface area/reactor volume ratio and different reactor diameter. At the low leading rate of 0.4 kg $COD/m^3{\cdot}d$, reactor performance was not affected by reactor diameter. At the organic loading rate of 6 kg $COD/m^3{\cdot}d$, however, volatile acid accumulation and low COD removal efficiency is observed in reactor having 6.4 cm diameter, while volatile acid is not accumulated at all and high COD removal efficiency is observed in reactor having 3 cm diameter. Such a difference of reactor performance depending on reactor diameter can be explained that sludge bed can be fluidized by evolved gas bubble in narrow reactor, while sludge bed ran not be fluidized by evolved gas bubble only in wide reactor. At a high organic loading rate of 20 kg $COD/m^3{\cdot}d$, it can be judged that there is no relation between reactor configuration and reactor performance because all reactors showed very low COD removal efficiencies regardless of reactor diameter. Narrow and tall type reactor is favorable condition for making sludge bed fluidization at a constant surface area/reactor volume ratio. Thus, it can be judged that reactor configuration and sludge bed fluidization have great influence to reactor performance.

고정 생물막공법에서 부착미생물의 역세에 관한 연구 (A Study of Attached Biomass Back Washing in Fixed Film System)

  • 이창근;김정숙
    • 한국환경과학회지
    • /
    • 제6권3호
    • /
    • pp.219-224
    • /
    • 1997
  • The cloging phenomenon in the fixed film reactor Is shown when biomass growth Is excessive for long operating time. In addition, effluent water Quality gets worse because of detachment of biomass. In this study, we conducted air-backwashing to sustain biomass In reactor to complement these defects. The results of experimental are showed In the following conclusion. The detachment rate was 19.5 - 38.0% when the organic loading rate was 0.40 - 1.32 kg COD/$m^3$/day, the k - backwashing Intensity was 2 L/min(6.7 $m^3$/$m^2$/hrl and the backwashing time was 15 - 19 seconds. And the detachment rate was 32.2 - 58.6 % when the organic loading rate was 1.37 - 2.27 kg COD/$m^2$/day, the backwashing time was 1 - 12 minutes. As orgnic loading rate and backwashing time ale Increased, detachment of fixed biomass Is Increased. The detachment equation with detachment rate(DR, %), backwashing time(BWT, min), fixed biomass concentration(FB. mg/L), and organic leading rate(OLR, kg COD/ms/day) through multiple linear regession was given by the following equation: DR : 17.964 $BWT^{0.1407} FB^{0.0597} OLR^{0.1946}$

  • PDF

계절에 따른 비강우시 팔당호의 유기물 유입부하량 (Loading of Organic Matter according to Seasonal Changes into Lake Paldang during Non-storm Period)

  • 길경익;신지웅;허진
    • 한국물환경학회지
    • /
    • 제27권4호
    • /
    • pp.433-437
    • /
    • 2011
  • The study is conducted to evaluate loading of organic matter as seasonal changes during non-storm period into Lake Paldang which is used to a major drinking water source. Samples were taken in Lake Paldang intake during non-storm period and were analyzed loading of organic matter. From the results of the survey, improving of the water quality showed remarkable tendency depending on the changing periods from summer to fall and from fall to winter. Dilution effect from the increase of base run-off caused by the concentrated rainfall in rainy season, the characteristics of Korea's climate seems to have to be the reason. On the other hand, deteriorating of the water quality showed tendency depending on the changing periods from winter to spring and from spring to summer. Increase of Cyanobacteria etc. is explained by seasonal effects which are a small amount of the rainfall in winter and spring and gradational increase of water temperature.

음폐수 부하량에 따른 고온호기성 공정의 처리 양상 (Influence of Food Wastewater Loading Rate on the Reactor Performance and Stability in the Thermophilic Aerobic Process)

  • 장현민;최석순;하정협;박종문
    • 공업화학
    • /
    • 제24권3호
    • /
    • pp.279-284
    • /
    • 2013
  • 본 연구에서는 음식물류 폐기물 자원화 과정에서 생성되는 고농도 음폐수(food wastewater : FWW)를 대상으로 기존의 혐기성 공정의 대안책으로써 고온호기성 소화공정에 대한 성능을 검증하였고 공정 인자를 도출하였다. 이를 위해 수리학적 체류시간(Hydraulic retention time, HRT) 변화 및 유기물 부하량(Organic loading rate, OLR)에 따른 유기물 제거 효율과 안정성을 관찰하였다. 실험 결과 비교적 짧은 HRT를 가진 R1 (HRT : 5일)의 경우 OLR이 증가할 때, 급격한 pH감소가 일어나 심한 공정 저해를 받는 것으로 관찰되었다. 반면 R2 (HRT : 10일)의 경우에는 상대적으로 안정적인 공정 운전 및 효율적인 COD, 유기산 및 lipid 제거가 일어났다. 이는 상대적으로 긴 HRT로 인한 유기산 축적과 같은 공정저해 요인이 해결되어 상대적으로 높은 유기물 처리효율을 나타낸 것으로 생각된다. R1에서는 COD 부하량이 $18.6kgCOD/m^3d$에서 $28.4kgCOD/m^3d$으로 증가함에 따라 급격한 COD 제거율 감소를 보였다. 반면 R2에서는 각 OLR별로 3.61, 7.05, 9.43 그리고 $12.2kgCOD/m^3d$의 높은 COD 제거율을 보였다. 따라서 본 연구에서는 10일 이상의 HRT에서 고온 호기성 소화가 고농도 음폐수 처리에 탁월한 유기물 제거율을 나타냄을 알 수 있었다.

농촌유역에서의 유기물 흐름의 평가-충북 청원군 가덕면 유역을 대상으로 (Evaluation of Organic Matter Flow in Rural Watersheds)

  • 오광영;김진수
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.676-681
    • /
    • 1999
  • The organic matter flow in rural watershed in Chongwon-gun , Chungbuk, was evaluated, The study watershed is about 67$\textrm{km}^2$ in area and its population was 7,000 in 1996. The amount of inflow in the study area exceeds the amount of outflow by 534kg/ha , and the livestock feed account for 90 percent of the amount of inflow. The loading of organic matter by livestock waste amounts to 51 percent of total loading to agricultural land and the enviornment. The increase in recycling of livestock waste is essential for the management of orgainc matter in the rural watershed.

  • PDF