• Title/Summary/Keyword: Organic Loading Rate

Search Result 280, Processing Time 0.027 seconds

Effect of F/R ratio of ASBR (Anaerobic Sequencing Batch Reactor) Process on Removal of the Organic Matters in Ammonia Stripped Swine Wastewater (ASBR(Anaerobic Sequencing Batch Reactor) 공정의 F/R비가 암모니아가 탈기된 축산폐수의 유기물 제거에 미치는 영향)

  • Whang, Gye-Dae;Cho, Young-Moo
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.6
    • /
    • pp.687-694
    • /
    • 2005
  • Lab-scale experiments have been carried out to investigate the effect of F/R ratio of ASBR (Anaerobic Sequencing Batch Reactor) process on the removal of the organic matters in ammonia stripped swine wastewater. Three ASBR inoculated with sludge mixed with granular sludge of UASB (Upflow Anaerobic Sludge Blanket) and anaerobic digested sludge of municipal wastewater treatment plant were operated. Ammonia stripped swine wastewater was used as influent. Prior to conducting the experiments with varied conditions, the effect of increasing organic loading rate from 2.34 to $5.79gTCOD_{Cr}/L$-day at a fixed F/R ratio of 0.1 on the organic removal efficiency has been studied during start-up period. As the result of the experiment, under the condition of varied organic loadings, less than $4.14gTCOD_{Cr}/L$-day, the removed efficiency $TCOD_{Cr}$ of the ASBR process is 83% resulted from the mean value of effluent $TCOD_{Cr}$, 9,125 mg/L during the start-up period. Then ASBRs were operated with F/R ratio of 0.024, 0.303 and 0.91 respectively. Organic loading rate was increased from 4.56 to $15.43gTCOD_{Cr}/L$-day to investigate the effects of F/R ratio and organic loading rate on the organic removal efficiency. As the result of the experiment, less than $6.23gTCOD_{Cr}/L$/L-day, F/R ratio haven't an effect on the organic removal efficiency and the mean removal efficiency of TSS, $TCOD_{Cr}$ and $SCOD_{Cr}$ was about 80%, 86% and 78% at the all of F/R ratio. But as organic loading rate was increased from 8.54 to $12.04gTCOD_{Cr}/L$-day at the F/R ratio of 0.024, the removal efficiency of $SCOD_{Cr}$ decreased from 71% to 63%. The range of decreased removal efficiency of $SCOD_{Cr}$ at the F/R ratio of 0.024 was much more higher than at the F/R ratio of 0.303, 0.91. Thus, as organic loading rate was increased, ASBRs were operated with high F/R ratio to obtain high removal efficiency.

Performance of Upflow Anaerobic Sludge Blanket (UASB) Reactor Depending on Reactor Configuration and Sludge Bed Fluidization (반응조 형태 및 슬러지층 유동화 특성에 따른 Upflow Anaerobic Sludge Blanket (UASB) 반응조의 운전효율)

  • Jeong Byung-Gon
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.2 s.89
    • /
    • pp.179-185
    • /
    • 2006
  • Effect of organic loading rate on UASB performance was evaluated under the renditions of some surface area/reactor volume ratio and different reactor diameter. At the low leading rate of 0.4 kg $COD/m^3{\cdot}d$, reactor performance was not affected by reactor diameter. At the organic loading rate of 6 kg $COD/m^3{\cdot}d$, however, volatile acid accumulation and low COD removal efficiency is observed in reactor having 6.4 cm diameter, while volatile acid is not accumulated at all and high COD removal efficiency is observed in reactor having 3 cm diameter. Such a difference of reactor performance depending on reactor diameter can be explained that sludge bed can be fluidized by evolved gas bubble in narrow reactor, while sludge bed ran not be fluidized by evolved gas bubble only in wide reactor. At a high organic loading rate of 20 kg $COD/m^3{\cdot}d$, it can be judged that there is no relation between reactor configuration and reactor performance because all reactors showed very low COD removal efficiencies regardless of reactor diameter. Narrow and tall type reactor is favorable condition for making sludge bed fluidization at a constant surface area/reactor volume ratio. Thus, it can be judged that reactor configuration and sludge bed fluidization have great influence to reactor performance.

P RELEASE AND UPTAKE ACCORDING TO INFLUENT ORGANIC LOADING IN BNR PROCESS

  • Kim, Kwang-Soo;Ahn, Chang-Hoon;Park, Jae-Kwang
    • Environmental Engineering Research
    • /
    • v.10 no.6
    • /
    • pp.265-268
    • /
    • 2005
  • A batch-type study was conducted to investigate the phosphorus release and uptake under anaerobic and aerobic conditions according to organic loading changes. As organic loading increased, anaerobic P release increased but aerobic P uptake decreased. Where organic carbon contents remain high in aerobic conditions, PHB consumption within the microbial cells diminished, therefore it was found that in order to enhance P uptake rate, it should reach the endogenous growth stage where the entire organic loading was consumed.

Effect of Loading Rate in the Operation of DEPHANOX and Modified-DEPHANOX Processes (유입부하가 DEPHANOX 및 Modified-DEPHANOX 공정에 미치는 영향)

  • Ryu, Hong-Duck;Min, Kyung-Kook;Lee, Sang-Ill
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.1
    • /
    • pp.24-31
    • /
    • 2004
  • This study was initiated to evaluate the efficiencies of DEPHANOX and Modified-DEPHANOX, which were devoloped to enhance nitrogen removal efficiency in municipal wastewater treatment. In the results, removal efficiency of organic matters was not affected much by increased loading rate of organic matters which is contained in influent. The nitrogen removal efficiencies according to the loading rate of influent TN was decreased drastically in conditions of over $0.2kg/m^3{\cdot}day$, which is T-N loading rate, and the DEPHANOX process was affected more sensitively than the M-DEPHANOX was. When the temperature was altered from $25^{\circ}C$ to $16^{\circ}C$ at HRT 6hrs, the removal efficiency of ammonia nitrogen was still over 90% and it was concluded that both DEPHANOX and M-DEPHANOX were strong enough to endure temperature variation. Moreover, both processes showed over 90% in ammonia removal efficiencies in over HRT 5hrs, so it was concluded that they were strong in HRT variation. M-DEPHANOX process showed a higher value than DEPHANOX did in T-N removal efficiency to the extent of 4~21 %, which resulted from differency of denitrification rates and the biosorption efficiency of organic matter in both processes. In the condition of HRT less than 4hrs, concentrations of ammonia nitrogen contained in effluents and nitrification reactors, might be sensitively affected by biosorption efficiency of organic matters in first separation tank. In the effect of effluent nitrate concentration in phosphorus removal, the more effluent nitrate concentration was decreased, the more phosphorus removal efficiency was increased. This result is related to the decrease of concentration of effluent nitrate which resulted from nitrification inhibition by decreased HRT.

Influence of Food Wastewater Loading Rate on the Reactor Performance and Stability in the Thermophilic Aerobic Process (음폐수 부하량에 따른 고온호기성 공정의 처리 양상)

  • Jang, Hyun Min;Choi, Suk Soon;Ha, Jeong Hyub;Park, Jong Moon
    • Applied Chemistry for Engineering
    • /
    • v.24 no.3
    • /
    • pp.279-284
    • /
    • 2013
  • In this study, the feasibility of a single-stage thermophilic aerobic process for the treatment of high-strength food wastewater produced from the recycling process of food wastes was examined to substitute anaerobic digestion process. Also, the removal and stability of thermophilic aerobic process were assessed according to the changes of hydraulic retention times (HRTs) and organic loading rates (OLRs). When the OLR increased from 9.2 to $37.2kgCOD/m^3d$, a pH value in R1 (HRT : 5 d) significantly decreased to 5.0, due to the organic acid accumulation. On the other hand, the pH value in R2 (HRT : 10 d) was stable and R2 showed the high removal of COD, organic acid and lipid, even though the OLR increased from 4.6 to $18.6kgCOD/m^3d$. In R1, the COD loading rates for COD removal was suddenly dropped, as the COD loading rate increased from 18.6 to $28.4kgCOD/m^3d$. In contrast, R2 showed that the COD loading rates for COD removal increased with regard to increment in the loading rates of 3.61, 7.05, 9.43 and $12.2kgCOD/m^3d$, indicative of the high COD removal efficiency. Therefore, the results demonstrated that over 10-d HRT, the high concentration of raw food wastewater was efficiently treated in the single-stage thermophilic aerobic process.

Treatment of Organic Wastewater by the Anaerobic Fixed-Film Process (혐기성 생물막법에 의한 유기성 배수의 처리)

  • 김용대;정경훈
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.2
    • /
    • pp.41-47
    • /
    • 1991
  • A study on the effects of volumetric loading rate, surface loading rate and hydraulic. retention time (HRT) for the anaerobic treatment was conducted with the anaerobic fixed-film process using synthetic wastewater at lower temperature than that of conventional anaerobic treatment. The results are as follows 1. Alkalinity and pH value decreased as the hydraulic retention time increased 2. Increase of the volumetric lodaing rate led to increasl of effluent COD concentration and decrease of COD removal efficiency. 3. The removed volumetric loading rate increased linearly according to the increase of the volumrtric loading rate. 4. Similarly, the linear increase of the removed surface loading rate was noticed with an increase of the surface loading rate.

  • PDF

Effects of Organic Loading Rates on Treatment Performance in a Polyvinylidene Media Based Fixed-Film Bioreactor

  • Ahmed, Zubair;Oh, Sang-Eun;Kim, In S.
    • Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.238-242
    • /
    • 2009
  • This study investigated the effects of organic loading rates on simultaneous carbon and nitrogen removal in an innovative fixed-film aerobic bioreactor. The fixed-film bioreactor (FFB) was composed of a two-compartment aeration tank, in which a synthetic filamentous carrier was submerged as biofilm support media, and a settling tank which polyvinylidene media (Saran) was used as settling aid for suspended solids. Three different organic loading rates, ranging from 0.92-2.02 kg chemical oxygen demand/$m^3$/day were applied by varying hydraulic retention time (HRT). The total soluble organic carbon removal efficiencies were in the range of 90-97%. The removal efficiency of ammonia was found to be in the range of 70-84%. Total nitrogen removal efficiency was found to be in the range of 40-45%, which indicates that denitrification reactions occurred simultaneously in the attached biofilm on the fibrous media in the aeration tank. The settling performance of suspended solids was significantly improved due to the presence of Saran media in the settling compartment, even for a short HRT. The fixed-film aerobic bioreactor used in this study demonstrated efficient treatment efficiency even at higher organic loading rates and at short HRTs.

Anaerobic Digestion Fish Offal(I): Effect of Reactor Configuration and Sludge Bed Fluidization on Start-up of Digester (어류 폐기물의 혐기성소화 처리(I): 반응조 형상 및 슬러지층 유동화가 소화조 Start-up에 미치는 영향)

  • Jeong Byung-Gon;Kim Byung-Hyo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.9 no.2
    • /
    • pp.72-78
    • /
    • 2006
  • Effect of organic loading rate on digester performance was evaluated under the conditions of same surface area/reactor volume ratio and different reactor diameter. At the low loading rate of $0.4\;kg\;COD/m^3{\cdot}d$, high rate of organic removal could be obtained regardless of reactor diameter. It can be estimated that reactor configuration can not affect reactor performance at the low loading rate. However, different performance depending on reactor diameter was observed at the organic loading rate of $6\;kg\;COD/m^3{\cdot}d$. That is, volatile acid accumulation and low COD removal efficiency was observed in reactor having 6.4 cm diameter, while volatile acid was not accumulated at all and high COD removal efficiency was observed in reactor having 3 cm diameter. Such a difference of reactor performance depending on reactor diameter can be explained that sludge bed can be fluidized by evolved gas bubble in narrow reactor while sludge bed can not be fluidized by evolved gas bubble only in wide reactor. At a high organic loading rate of $20\;kg\;COD/m^3{\cdot}d$, it can be judged that there is no relation between reactor configuration and reactor performance because all reactors showed very low COD removal efficiencies regardless of reactor diameter. Sludge bed fluidization is one of the most important factors in achieving efficient start-up of anaerobic digester. Narrow and tall type reactor is favorable condition for making sludge bed fluidization at a constant surface area/reactor volume ratio. Thus, it can be judged that reactor configuration and sludge bed fluidization have great influence to reactor performance.

  • PDF

Anaerobic Treatment of High Strength Organic Wastewater by Granulated Microorganism (입상미생물을 이용한 고농도 유기성폐수의 혐기성처리)

  • Rim, Jay-Myoung;Han, Dong-Joon;Jun, Tae-Sung;Lee, Hyun-Joo
    • Journal of Industrial Technology
    • /
    • v.16
    • /
    • pp.61-70
    • /
    • 1996
  • This research aims to find granulation and organic removal of the piggery wastewater with the upflow blanket filter(UBF) reactor. UASB process had the effect of high pH on the granulation phase. But teh effect was decreased after the granule formation. The filter zone of the UBF reactor had the function of GSS and contributed to removing the organic because of its biofilm formation. The removal rates of total COD and soluble COD were 70% ~ 80% and 60 ~ 80% at an influent organic loading range of $2{\sim}17.4kgCOD/m^3{\cdot}d$, respectively. The methane production rate with the organic removal was $0.21{\sim}0.34{\ell}CH_4/gCOD_{rem}$ and the maximum methan production rate was $0.34CH_4{\ell}/gCOD_{rem}$ at the volumetric loading $5kgCOD/m^3{\cdot}d$.

  • PDF

Effect of Organic Loading Rate and Hydralic Retention Time on the Volatile Fatty Acid Production in 2- Step Anaerobic Fermentation System of Swine Wastes (돈분의 2단계 혐기발효시 산생성 단계에서의 유기물 부하율과 체류시간에 따른 휘발성지방산의 생산량)

  • 김범석;이상락;맹원재
    • Journal of Animal Environmental Science
    • /
    • v.4 no.2
    • /
    • pp.167-174
    • /
    • 1998
  • It is known that the anaerobic fermentation of organic matter (OM) is divided into 2 phases, acidogenic phase in which OM is digested into volatile fatty acid (VFA), and methanogenic phase where the produced VFA is converted to CH4 and CO2. In a natural fermenting procedure, these 2 phases occur at the same time. However the total production of end products (methane) may be limited if these 2 phases occur at the same time. This is believed to be due to the difference in growth rate, substrate-utilizing efficiency and favorable environment for each microbes (acidogens and methanogens), involved in each phase. It is therefore suggested for the maximum recycling of organic waste (such as animal waste) through providing 2 different steps in fermenting procedure, acidogenic phase and methanogenic phase, in each case the activity of involved microbes can be maintained at the maximum level. The results obtained from these experiments are summarized as follows : The loading rates of swine waste were made through 2.5, 5 and 10 gVS / l / d to identify its acidogenic fermenting character in this study. The VFA yield was maximized at 10 gVS / l / d of loading rate. On the basis of this study was executed to identify the optimum HRT of 1, 2 and 4 days at 10 gVS / l / d of loading rate in acidogenic phase. The maximum VFA yield was obtained at 1 days of HRT.

  • PDF