• Title/Summary/Keyword: Order-specific equipment

Search Result 142, Processing Time 0.035 seconds

Implementation of an E-BOM Copy Method for an Order-specific Semiconductor Equipment (주문 생산형 반도체 장비를 위한 E-BOM 복제 방법의 구현)

  • Park, Dong-Seok;Yang, Jeong-Sam;You, Ki-Hyoun;Park, Beom
    • Korean Journal of Computational Design and Engineering
    • /
    • v.13 no.4
    • /
    • pp.273-285
    • /
    • 2008
  • In this paper we propose an engineering bill of materials (E-BOM) copy method that can be utilized to manage the product information for each equipment during building a product lifecycle management (PLM) system in the order-specific semiconductor equipment manufacturer. The previous works studied on an E-BOM creation and management method for the mass manufacturing and production. The method is difficult to apply to an environment in which many engineering changes occur and the different specification to each equipment is required such as semiconductor equipments and facilities adopting built-to-order instead of built for inventory. Moreover the method is known to be the major drawback to deteriorate the design efficiency. Our E-BOM copy method enables users efficiently to manage the specification of a product and shortens the product development cycle. To implement the E-BOM copy method in the PLM environment, we developed the E-BOM copy system that automatically generates new parts and their numbers according to the numbering rule while copying the E-BOM from existing semiconductor equipments and then can apply the parts for reuse to new semiconductor equipments. This system can duplicate not only 3D CAD data but also technical documents.

A Study on description method of product information by utilizing a display specific for store support

  • Hong, Sinyou;Kim, Hyung-O;Ann, Myungsuk;Lee, Seungyoun;Cha, Jaesang
    • International journal of advanced smart convergence
    • /
    • v.4 no.2
    • /
    • pp.76-83
    • /
    • 2015
  • Various products are displayed and traded in superstores. Therefore, providing the information of these diverse products plays a crucial part in acknowledging their presence. Currently, superstores mostly utilize printed materials to provide product information and promotion of displayed products. A display equipment is utilized for providing product information and promotion of certain high-end and new products. As such, utilizing an expensive display equipment in order to provide product information fragmentarily for 1 product or successively can be referred to as being inefficient. This paper aims at proposing a method that enables the description of product information efficiently by utilizing a display specific for store support in order to overcome the restriction mentioned above. A test was executed in order to verify the potential of the method of providing product information though the proposed display.

Experimental assessment of slamming coefficients for subsea equipment installations

  • de Oliveira, Allan C;Pestana, Rafael G
    • Ocean Systems Engineering
    • /
    • v.10 no.2
    • /
    • pp.163-179
    • /
    • 2020
  • Considering the huge demand of several types of subsea equipment, as Christmas Trees, PLEMs (Pipeline End Manifolds), PLETs (Pipeline End Terminations) and manifolds for instance, a critical phase is its installation, especially when the equipment goes down through the water, crossing the splash zone. In this phase, the equipment is subject to slamming loads, which can induce impulsive loads in the installation wires and lead to their rupture. Slamming loads assessment formulation can be found in many references, like the Recommended Practice RP-N103 from DNV-GL (2011), a useful guide to evaluate installation loads. Regarding to the slamming loads, RP-N103 adopt some simplifying assumptions, as considering small dimensions for the equipment in relation to wave length, in order to estimate the slamming coefficient CS used in load estimation. In this article, an experimental investigation based on typical subsea structure dimensions was performed to assess the slamming coefficient evaluation, considering a more specific scenario in terms of application, and some reduction of the slamming coefficient is achieved for higher velocities, with positive impact on operability.

Development of Low Price Digital Endoscope with Database System

  • Kim, Sang-Bong;Lee, Young-Hwan;Kim, Sung-Wook;Kim, Suk-Yoel;Jeong, Nam-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.74.2-74
    • /
    • 2001
  • The availability of endoscope has been increased not only for observing inner parts of body but also for operating. Nowdays, the market of the endoscope has been widely extended and we presume that the value of marketablity will reach to wide. Most of the endoscope equipment is very expensive and as well, it costs a lot to repair or change the specific parts of equipment when it´s out of order on account of carelessness. About 90 percent of the endoscope equipment in the world is made in Japan. Therefore, to buy or repair the equipment, we can´t help outflowing foreign currency. In domestic, the efforts for localization and manufacturing the endoscope equipment are short. This paper shows that captured image from a CCD miniature carema is managed ...

  • PDF

A study on the implementation of tele diagnosis and repair on fire-fighting system using HTTP network (인터넷망을 이용한 소방설비 시스템의 원격 진단 및 고장수리의 실현에 관한 연구)

  • 김광태;정수일
    • Journal of the Korea Safety Management & Science
    • /
    • v.4 no.1
    • /
    • pp.27-36
    • /
    • 2002
  • This paper describes "the remote automatic diagnosis and repair system which automatically reads the problems such as "out of order" occurred on equipment at customer's equipment from a remote computer center using HTTP(hyper text transfer protocol). It shows the scheme of the network configurations and features of the system. In addition, a way to implement the overall system, the specific functions of unit, and the operational specifications between the center's computer and customer's computer are also presented.also presented.

On the study of Chemical Disaster Cause Chemical Detection Process (화학재난 현장에서의 사건원인 화학물질 탐지절차 연구)

  • Kim, Sungbum;Ahn, Seungyoung;Lee, Jinhwan
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.3
    • /
    • pp.452-457
    • /
    • 2014
  • The event of a Chemical disaster response personnel are causative events quickly Appearance & residual contaminant concentrations, should be identified accurately. In addition, the chemical disaster response procedure appropriate progress in the field of Chemical Composition and contaminant concentrations in order confirmation is essential. Use in the field to using the characteristics of each equipment. on-Site response equipment can not verify all the chemicals, materials detection, limited by each equipment. Detection range of equipment & specific materials should be considered complementary. In this study, using the equipment on-site detection of detection kit and detector tube, electronic detection equipment utilized for the rapid response procedure for helping a person to cope.

Analysis of faust cause & insulation degradation on the electrical equipments for railway (철도용 전기기기의 고장요인 및 절연열화 분석)

  • 왕종배;전한준;박옥정;온정근
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.207-210
    • /
    • 2001
  • Electrical equipment for railway is always experiencing wear and degradation by mechanical, electrical and environmental stress in service and the fault or the accident of high voltage main circuit directly causes operation interruption. Particularly propulsion drive of high speed switching inverter takes the form of specific degradation mechanism such as fast rising transient surge, reflective overvoltage and harmonic stress, and it is known that it threatens the long life and the reliability of electrical equipment. In this paper, statistics of fault and accident on main electrical equipment for railway are presented and also insulation degradation mechanism, which governs end life of electrical device, is analyzed. Finally the method of fault respondence and reliability improvement on the main electrical equipments will be reviewed in order to prevent operation interruption.

  • PDF

Case Study : Application of Specific Evaluation Criteria For Safety Circuit Design of EN ISO 13849-1 (사례 연구 : EN ISO 13849-1의 안전회로 설계를 위한 구체적 평가 기준의 적용)

  • Jung, Hwansuk;Lee, Dongju
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.1
    • /
    • pp.94-101
    • /
    • 2018
  • With the development of industrial technology and science, production and manufacturing facilities have been enhanced and improved, and the importance of the safety of workers has also been regulated and limited by various safety management methods. As a way to secure the safety of the workers from the production facility, the fail-safe and fool-proof methods are now being applied. Any possible insecure behavior and unsafe conditions can be removed by adopting the standards and specifications that are now secure the safety of workers and equipment. This research analyzes EN ISO 13849-1 international and European standards during CE certification. In order to secure acceptable reduced risks, the risk assessment process of ISO 12100 and the processes for reducing its risk are applied. In the current ISO 13849-1 standard, the criteria for the required performance level PLr (Required Performance Level) for the applicable risk and safety functions through the risk assessment are subjective and not subdivided. Therefore, the evaluation criteria are likely to cause judge's judgement error due to qualitative judgement. This research focuses on evaluation and acceptable performance level setting for the safety circuit of the equipment. We propose an objective and specific evaluation criteria to secure safety, and the proposed evaluation criteria are applied to the case study of the safety circuit for the equipment. In order to secure the safety of the entire safety circuit, the improvement of the MTTFd and DC level related to the SRP/CS (Safety-Related Parts of Control Systems)' lifetime is required for the future research.

Proposing a low-frequency radiated magnetic field susceptibility (RS101) test exemption criterion for NPPs

  • Min, Moon-Gi;Lee, Jae-Ki;Lee, Kwang-Hyun;Lee, Dongil
    • Nuclear Engineering and Technology
    • /
    • v.51 no.4
    • /
    • pp.1032-1036
    • /
    • 2019
  • When the equipment which is related to safety or important to power production is installed in nuclear power plant units (NPPs), verification of equipment Electromagnetic Susceptibility (EMS) must be performed. The low-frequency radiated magnetic field susceptibility (RS101) test is one of the EMS tests specified in U.S NRC (Nuclear Regulatory Commission) Regulatory Guide (RG) 1.180 revision 1. The RS101 test verifies the ability of equipment installed in close proximity to sources of large radiated magnetic fields to withstand them. However, RG 1.180 revision 1 allows for an exemption of the low-frequency radiated magnetic susceptibility (RS101) test if the safety-related equipment will not be installed in areas with strong sources of magnetic fields. There is no specific exemption criterion in RG 1.180 revision 1. EPRI TR-102323 revision 4 specifically provides a guide that the low-frequency radiated magnetic field susceptibility (RS101) test can be conservatively exempted for equipment installed at least 1 m away from the sources of large magnetic fields (>300 A/m). But there is no exemption criterion for equipment installed within 1 m of the sources of smaller magnetic fields (<300 A/m). Since some types of equipment radiating magnetic flux are often installed near safety related equipment in an electrical equipment room (EER) and main control room (MCR), the RS101 test exemption criterion needs to be reasonably defined for the cases of installation within 1 m. There is also insufficient data regarding the strength of magnetic fields that can be used in NPPs. In order to ensure confidence in the RS101 test exemption criterion, we measured the strength of low-frequency radiated magnetic fields by distance. This study is expected to provide an insight into the RS101 test exemption criterion that meets the RG 1.180 revision 1. It also provides a margin analysis that can be used to mitigate the influence of low-frequency radiated magnetic field sources in NPPs.

Equipment for Measuring the Adiabatic Temperature Rise of Concrete by Compensating Heat Loss (열손실량 보정을 통한 콘크리트 단열온도상승량 예측 장치)

  • Jin, Eun-Woong;Kim, Chin-Yong;Kim, Jin-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.5
    • /
    • pp.535-542
    • /
    • 2012
  • Adiabatic temperature rise test for predicting heat of hydration in mass concrete is especially inconvenient in the field. In order to overcome the problem, the equipment to effectively and conveniently measure semi-adiabatic temperature change was developed. The main objective of this paper is to propose a new and simple equipment for measuring semi-adiabatic temperature rise by using insulation bottles. In order to predict exact heat loss of concrete using this device, it is required to assume the specific heat loss coefficient of the device by water temperature change inside the experimental device. According to experimental and analytical results, the adiabatic temperature rise does not have significant differences in changes of temperature and humidity of air, as well as initial temperature of water. By comparing adiabatic temperature rise tests, the equipment for measuring semi-adiabatic temperature change can be used to predict the hydration heat of concrete within sufficient accuracy.