• Title/Summary/Keyword: Orbital wall fractures

Search Result 66, Processing Time 0.025 seconds

Orbital wall restoration with primary bone fragments in complex orbital fractures: A preliminary study

  • Jung, Joo Sung;Kang, Dong Hee;Lim, Nam Kyu;Kim, Hyonsurk
    • Archives of Craniofacial Surgery
    • /
    • v.21 no.3
    • /
    • pp.156-160
    • /
    • 2020
  • Background: We have reported orbital wall restoration surgery with primary orbital wall fragment in pure blowout fractures using a combination of transorbital and transnasal approach in pure blow out fractures. However, this method was thought to be difficult to use for complex orbital wall fractures, since the sharp screw tip that fixate the maxillary wall increases the risk of balloon ruptures. In this study, we reviewed 23 cases of complex orbital fractures that underwent orbital wall restoration surgery with primary orbital wall fragment and evaluated the result. Methods: A retrospective review was conducted of 23 patients with complex orbital fracture who underwent orbital restoration surgery with primary orbital wall fragments between 2012 and 2019. The patients underwent orbital wall restoration surgery with primary orbital wall fragment with temporary balloon support. The surgical results were evaluated by the Naugle scale and a comparison of preoperative and postoperative orbital volume ratio. Complex fracture type, type of screw used for fixation and complications such as balloon rupture were also investigated. Results: There were 23 patients with complex orbital fracture that used transnasal balloon technique for restoration. 17 cases had a successful outcome with no complications, three patients had postoperative balloon rupture, two patients had soft-tissue infection, and one patient had balloon malposition. Conclusion: The orbital wall restoration technique with temporary balloon support can produce favorable results when done correctly even in complex orbital wall fracture. Seventeen cases had favorable results, six cases had postoperative complications thus additional procedure seems necessary to complement this method.

Orbital wall restoration with primary bone fragments in complex orbital fractures

  • Jong Hyun Park;Dong Hee Kang;Hong Bae Jeon;Hyonsurk Kim
    • Archives of Craniofacial Surgery
    • /
    • v.24 no.2
    • /
    • pp.52-58
    • /
    • 2023
  • Background: Complex orbital fractures are impure orbital fractures because they involve the orbital walls and mid-facial bones. The author reported an orbital wall restoration technique in which the primary orbital wall fragments were restored to their prior position in complex orbital fractures in 2020. As a follow-up to a previous preliminary study, this study retrospectively reviewed the surgical results of complex orbital wall fractures over a 4-year period and compared the surgical outcomes by dividing them into groups with and without balloon restoration. Methods: Data of 939 patients with facial bone fractures between August 2018 and August 2022 were reviewed. Of these, 154 had complex orbital fractures. Among them, 44 and 110 underwent reduction with and without the balloon technique respectively. Pre- and postoperative Naugle exophthalmometer (Good-Lite Co.) scales were evaluated. The orbital volume and orbital volume ratio were calculated from preoperative and 6 months postoperative computed tomography images. Results: Among 154 patients with complex orbital fractures, 44 patients underwent restoration with the balloon technique, and 110 patients underwent restoration without it. The Naugle scale did not differ significantly between the two groups, but the orbital volume ratio significantly decreased by 3.32% and 2.39% in groups with and without the balloon technique and the difference in OVR was significantly greater in patients in the balloon restoration group compared with the control group. Postoperative balloon rupture occurred in six out of 44 cases (13.64%). None of the six patients with balloon rupture showed significant enophthalmos at 6 months of follow-up. Conclusion: The balloon rupture rate was 13.64% (6/44 cases) with marginal screw fixation, blunt screws, and extra protection with a resorbable foam dressing. Furthermore, we restored the orbital wall with primary orbital fragments using balloon support in complex orbital wall fractures.

Reconstruction of Medial Orbital Wall Fractures without Subperiosteal Dissection: The "Push-Out" Technique

  • Kim, Yong-Ha;Lee, Jin Ho;Park, Youngsoo;Kim, Sung-Eun;Chung, Kyu-Jin;Lee, Jun-Ho;Kim, Tae Gon
    • Archives of Plastic Surgery
    • /
    • v.44 no.6
    • /
    • pp.496-501
    • /
    • 2017
  • Background Various surgical methods for repairing medial orbital wall fractures have been introduced. The conventional technique requires total separation of the displaced orbital bones from the orbital soft tissues. However, subperiosteal dissection around the fracture can cause additional damage. The aim of the present study is to introduce a method of reconstructing medial orbital wall fractures without subperiosteal dissection named the "push-out" technique. Methods Six patients with post-traumatic enophthalmos resulting from an old medial orbital wall fracture and 10 patients with an acute medial orbital wall fracture were included. All were treated with the push-out technique. Postoperative computed tomography (CT) was performed to assess the correct positioning of the implants. The Hertel scale and a comparison between preoperative and postoperative orbital volume were used to assess the surgical results. Results Restoration of the normal orbital cavity shape was confirmed by examining the postoperative CT scans. In the old fracture group, the median orbital volume of the fractured side was $29.22cm^3$ preoperatively, and significantly improved postoperatively to a value of $25.13cm^3$. In the acute fracture group, the median orbital volume of the fractured side was $28.73cm^3$ preoperatively, and significantly improved postoperatively to a value of $24.90cm^3$. Differences on the Hertel scale also improved, from 2.13 mm preoperatively to 0.25 mm postoperatively in the old fracture group and from 1.67 mm preoperatively to 0.33 mm postoperatively in the acute fracture group. Conclusions The push-out technique can be considered a good alternative choice for old medial orbital wall fractures with posttraumatic enophthalmos, acute medial orbital wall fractures including large fractured bone segments, and single-hinged greenstick fractures.

Classification of the Lateral Orbital Wall Fracture and Its Clinical Significance (안와 외벽 골절의 분류와 임상적 의의)

  • Cho, Pil Dong;Kim, Hyung Suk;Shin, Keuk Shun
    • Archives of Plastic Surgery
    • /
    • v.35 no.5
    • /
    • pp.553-559
    • /
    • 2008
  • Purpose: The lateral orbital wall fractures have been previously classified by some authors. As there are some limitations in applying in their own classifications, we hope to present a refined classification system of the lateral orbital wall fracture and to identify the correlation between the specific type of the fracture and clinical diagnosis. Methods: The facial bone CT scans and medical records of 78 patients with the lateral orbital wall fractures were reviewed in a retrospective manner. The classification is based on the CT scan. In type I, the fracture and its segments are away from the lateral rectus muscle and in type II, they are next to or slightly pushing the muscle in axial CT scan. In type III, the fracture segments compress and displace the longitudinal axis of the muscle or the optic nerve in axial view of CT scan. Type IV fracture includes multiple fractures found around the orbital apex or optic canal in coronal view of CT scans of the type I and type II fractures. Results: The most common fracture pattern was type I(43.6%), followed by type IV(29.5%), type II(20.5%), and type III(6.4%). As diplopia and restriction of extraocular muscles were found in type I and II fractures, severe ophthalmic complications such as superior orbital fissure syndrome, orbital apex syndrome, and traumatic optic neuropathy were found in type III and IV fractures almost exclusively. Conclusion: We propose an easy classification system of the lateral orbital wall fracture which correlates closely with ophthalmic complications and may help to make further treatment plan. In Type III and IV fractures, severe ophthalmic complications may ensue in higher rates, so early diagnosis and treatment should be performed.

Anatomical Reconstruction of the Medial Orbital Wall Fracture (안와내벽골절의 해부학적 복원술)

  • Choi, Woo Kyung;Kang, Dong Hee;Oh, Sang Ah
    • Archives of Craniofacial Surgery
    • /
    • v.13 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • Purpose: In surgical treatment of the medial orbital wall fractures, restoring the original position of the orbital wall is difficult in some cases. Under such condition, the orbital wall is often reconstructed with synthetic material, without bony reduction, which is considered to be the conventional reconstruction. The purpose of this study is to compare the outcomes of anatomical reconstruction, which restores the bony wall to the anatomical position, from that of the conventional reduction in the isolated medial orbital wall fractures. Methods: Thirty patients, who underwent reconstruction surgery for the isolated medial orbital wall fractures from March 2007 to August 2011, were reviewed retrospectively. The surgical outcomes of two groups, the conventional reconstruction group (15 patients) and the anatomical reconstruction group (15 patients), were studied in 2 measurements, a one day before and 6 months after the surgery. The changes of orbital volume were calculated by the images from a computed tomography scan and enophthalmos was measured by a Hertel exophthalmometer. Results: The orbital volume ratio was decreased by an average of 1.05% in the conventional reconstruction group, while in the anatomical reconstruction group, the ratio decreased by 5.90% (p<0.05). The changes in the Hertel scale were 0.20 mm in the conventional reconstruction group, and 0.70 mm in the anatomical reconstruction group. However, the difference in the Hertel scale was statistically insignificant (p>0.05). Conclusion: In conclusion, the anatomical reconstruction technique of the isolated medial orbital wall fracture results in a better outcome than that of the conventional reconstruction, in terms of restoring of the original orbital volume and anatomic position. Thus, it can be considered as a useful method for the isolated medial orbital wall fractures.

Orbital wall restoring surgery with resorbable mesh plate

  • Joo, Jae Doo;Kang, Dong Hee;Kim, Hyon Surk
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.4
    • /
    • pp.264-269
    • /
    • 2018
  • Background: Orbital resorbable mesh plates are adequate to use for isolated floor and medial wall fractures with an intact bony buttress, but are not recommended to use for large orbital wall fractures that need load bearing support. The author previously reported an orbital wall restoring surgery that restored the orbital floor to its prior position through the transnasal approach and maintained temporary extraorbital support with a balloon in the maxillary sinus. Extraorbital support could reduce the load applied on the orbital implants in orbital wall restoring surgery and the use of resorbable implants was considered appropriate for the author's orbital wall restoring technique. Methods: A retrospective review was conducted of 31 patients with pure unilateral orbital floor fractures between May 2014 and May 2018. The patients underwent transnasal restoration of the orbital floor through insertion of a resorbable mesh plate and maintenance of temporary balloon support. The surgical results were evaluated by the Hertel scale and a comparison of preoperative and postoperative orbital volume ratio (OVR) values. Results: The OVR decreased significantly, by an average of 6.01% (p<0.05) and the preoperative and postoperative Hertel scale measurements decreased by an average of 0.34 mm with statistical significance (p<0.05). No complications such as buckling or sagging of the implant occurred among the 31 patients. Conclusion: The use of resorbable mesh plate in orbital floor restoration surgery is an effective and safe technique that can reduce implant deformation or complications deriving from the residual permanent implant.

EFFECTS OF THE SITE AND THE EXTENT OF BLOWOUT FRACTURE ON ENOPHTHALMOS AND DIPLOPIA (Blowout 골절의 부위와 정도가 안구함몰 및 복시에 미치는 영향)

  • Hwang, Ung;Ryu, Sun-Youl
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.4
    • /
    • pp.292-300
    • /
    • 2004
  • Orbital blowout fractures are common consequence to blunt periorbital trauma. Pure orbital blowout fractures first occur at the weakest point of the orbital wall. Computed tomography(CT) is recognized to be the best imaging technique to evaluate orbital fractures. The extent and location of a blowout fractures in the CT scan were noted to have an effect on the clinical outcome. In the early posttraumatic period, the presence of significant enophthalmos is difficult to detect because of orbital edema. Early surgical intervention may improve the ultimate outcome because open reconstruction becomes more difficult if surgery is delayed. In this study, we evaluated isolated blowout fractures of the orbital floor by region-of-interest measurements from CT scans and their relationship to ophthalmologic findings. Six patients of the medial orbital wall fractures, eleven patients of the inferior orbital wall fractures, nineteen of the medial and the inferior orbital wall fractures confirmed by CT scan, were evaluated. The area of fracture and the volume of the displaced orbital tissue were determined from CT scan using linear measurements. Each of the calculated values for the area and the volume were compared with the degree of the enophthalmos, the diplopia, and the eyeball movement limitation to determine whether there was any significant relationship between them. The fracture area and the volume of the herniated orbital tissue were significantly positively correlated with the enophthalmos and the ocular motility limitation and not correlated with the diplopia. For the enophthalmos of 2mm or greater, the mean fracture area was 3.55{\pm}1.25cm^2$ and the volume of the herniated orbital tissue was $1.74{\pm}0.97cm^3$; for less than 2mm enophthalmos, $1.43{\pm}0.99cm^3$ and $0.52{\pm}0.49cm^3$, respectively. The enophthalmos of 2mm can be expected with $2.92cm^2$ of the fracture area and $1.40cm^3$ of the herniated orbital tissue. In conclusion, the enophthalmos of 2mm or more, which is a frequent indication for surgery. It can be expected when area of fracture is $2.92cm^2$ or more, or the volume of herniated orbital tissue is $1.40cm^3$ or more. And the CT scan using linear measurements has an application in the assessment of patients with blowout fractures and provides useful information in the posttraumatic evaluation of orbital fractures.

Three-Dimensional Pre-Bent Titanium Implant for Concomitant Orbital Floor and Medial Wall Fractures in an East Asian Population

  • Lee, Kyung Min;Park, Ji Ung;Kwon, Sung Tack;Kim, Suk Wha;Jeong, Eui Cheol
    • Archives of Plastic Surgery
    • /
    • v.41 no.5
    • /
    • pp.480-485
    • /
    • 2014
  • Background The objective of this article is to evaluate clinical outcomes of combined orbital floor and medial wall fracture repair using a three-dimensional pre-bent titanium implant in an East Asian population. Methods Clinical and radiologic data were analyzed for 11 patients with concomitant orbital floor and medial wall fractures. A combined transcaruncular and inferior fornix approach with lateral canthotomy was used for the exposure of fractures. An appropriate three-dimensional preformed titanium implant was selected and inserted according to the characteristics of a given defect. Results Follow-up time ranged from 2 to 6 months (median, 4.07 months). All patients had a successful treatment outcome without any complications. Clinically significant enophthalmos was not observed after treatment. Conclusions Three-dimensional pre-bent titanium implants are appropriate for use in the East Asian population, with a high success rate of anatomic restoration of the orbital volume and prevention of enophthalmos in combined orbital floor and medial wall fracture cases.

Reconstruction of the orbital wall using superior orbital rim osteotomy in a patient with a superior orbital wall fracture

  • Heo, Jae Jin;Chong, Ji-Hun;Han, Jeong Joon;Jung, Seunggon;Kook, Min-Suk;Oh, Hee-Kyun;Park, Hong-Ju
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.42.1-42.5
    • /
    • 2018
  • Background: Fractures of the orbital wall are mainly caused by traffic accidents, assaults, and falls and generally occur in men aged between 20 and 40 years. Complications that may occur after an orbital fracture include diplopia and decreased visual acuity due to changes in orbital volume, ocular depression due to changes in orbital floor height, and exophthalmos. If surgery is delayed too long, tissue adhesion will occur, making it difficult to improve ophthalmologic symptoms. Thus, early diagnosis and treatment are important. Fractures of the superior orbital wall are often accompanied by skull fractures. Most of these patients are unable to perform an early ocular evaluation due to neurosurgery and treatment. These patients are more likely to show tissue adhesion, making it difficult to properly dissect the tissue for wall reconstruction during surgery. Case presentation: This report details a case of superior orbital wall reconstruction using superior orbital rim osteotomy in a patient with a superior orbital wall fracture involving severe tissue adhesion. Three months after reconstruction, there were no significant complications. Conclusion: In a patient with a superior orbital wall fracture, our procedure is helpful in securing the visual field and in delamination of the surrounding tissue.

Degree of enophthalmos according to the extent of orbital wall fracture and volume of herniated orbital tissue (안와벽 골절 면적과 이탈된 안와내 조직의 부피에 따른 안구함몰 정도)

  • Jang, Hak-Sun;Leem, Dae-Ho;Baek, Jin-A;Shin, Hyo-Keun;Ko, Seung-O
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.3
    • /
    • pp.205-213
    • /
    • 2011
  • Introduction: The enlargement and deformation of the orbit give rise to a visible enophthalmos. As a consequence, a disturbance of eye motility together with double images is likely to occur. This study examined the degree of enophthalmos according to the extent of orbital wall fracture and volume of herniated orbital tissue in blowout fractures of the medial and inferior orbital wall. Materials and Methods: This study was performed on patients diagnosed with medial and inferior orbital wall fractures at the Department of Oral and maxillofacial surgery, Chonbuk National University Hospital from 2007 to 2009. The patients' age, gender, etiology of fracture and degree of enophthalmos were investigated. The changes in the degree of enophthalomos, diplopia and ocular motility restriction after operation were examined. Results: The degree of enophthalomos increased with increasing extent of orbital wall fracture and volume of herniated orbital tissue. Conclusion: Whether to perform the operation is decided after measuring the extent of the orbital wall fracture and volume of herniated orbital tissue using computed tomography (CT), time for the decision of operation can be shortened. This can cause a decrease in the complications of orbital wall fractures.