• Title/Summary/Keyword: Orbital volume

Search Result 52, Processing Time 0.026 seconds

Three-dimensional and topographic relationships between the orbital margins with reference to assessment of eyeball protrusion

  • Shin, Kang-Jae;Lee, Shin-Hyo;Koh, Ki-Seok;Song, Wu-Chul
    • Anatomy and Cell Biology
    • /
    • v.50 no.1
    • /
    • pp.41-47
    • /
    • 2017
  • This study investigated the topographic relationships among the eyeball and four orbital margins with the aim of identifying the correlation between orbital geometry and eyeball protrusion in Koreans. Three-dimensional (3D) volume rendering of the face was performed using serial computed-tomography images of 141 Koreans, and several landmarks on the bony orbit and the cornea were directly marked on the 3D volumes. The anterior-posterior distances from the apex of the cornea to each orbital margin and between the orbital margins were measured in both eyes. The distances from the apex of the cornea to the superior, medial, inferior, and lateral orbital margins were 5.8, 5.8, 12.0, and 17.9 mm, respectively. Differences between sides were observed in all of the orbital margins, and the distances from the apex of the cornea to the superior and inferior orbital margins were significantly greater in females than in males. The anterior-posterior distance between the superior and inferior orbital margins did not differ significantly between males (6.3 mm) and females (6.2 mm). The data obtained in this study will be useful when developing practical guidelines applicable to forensic facial reconstruction and orbitofacial surgeries.

Effectiveness of Computed Tomography for Blow-out Fracture

  • Rhee, Seung-Hyun;Kim, Tae-Seup;Song, Jae-Min;Shin, Sang-Hoon;Lee, Jae-Yeol
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.6
    • /
    • pp.273-279
    • /
    • 2014
  • Purpose: This study assessed the association between eye symptoms (enophthalmos or diplopia) and site of damage, volume, deviated inferior rectus muscle (IRM) and type of fracture with computed tomography (CT). The intent is to anticipate the prognosis of orbital trauma at initial diagnosis. Methods: Forty-five patients were diagnosed with fractures of the inferior wall of one orbit. Fracture area, volume of displaced tissue, deviated IRM, and type of fracture were evaluated from coronal CT by one investigator. The association of those variables with the occurrence of eye symptoms (diplopia and enophthalmos) was assessed. Results: Of 45 patients, 27 were symptom-free (Group A) and 18 had symptoms (Group B) of enophthalmos and/or diplopia. In Group B, 12 had diplopia, one was enophthalmos, and five had both. By CT measurement, group A mean area was $192.6mm^2$ and the mean volume was $673.2mm^3$. Group B area was $316.2mm^2$ and volume was $1,710.6mm^3$. The volume was more influential on symptom occurrence. Each patient was categorized into four grades depending on the location of IRM. Symptom occurrence and higher grade were associated. Twenty-six patients had trap-door fracture (one side, attached to the fracture), and 19 had punched-out fracture (both sides detached). The punched-out fracture was more strongly associated with symptoms and had statistically significantly higher area and volume. Conclusion: In orbital trauma, measurement of fracture area and volume, evaluation of the deviated IRM and classification of the fracture type by coronal CT can effectively predict prognosis and surgical indication.

Three-dimensional computer navigation in the reconstruction of complex unilateral orbital fractures: evaluation and review of applications

  • Parampreet Singh Saini;Rajesh Kumar;Manu Saini;Tarush Gupta;Sunil Gaba;Ramesh Kumar Sharma
    • Archives of Craniofacial Surgery
    • /
    • v.25 no.4
    • /
    • pp.161-170
    • /
    • 2024
  • Background: The eyes are the central aesthetic unit of the face. Maxillofacial trauma can alter facial proportions and affect visual function with varying degrees of severity. Conventional approaches to reconstruction have numerous limitations, making the process challenging. The primary objective of this study was to evaluate the application of three-dimensional (3D) navigation in complex unilateral orbital reconstruction. Methods: A prospective cohort study was conducted over 19 months (January 2020 to July 2021), with consecutive enrollment of 12 patients who met the inclusion criteria. Each patient was followed for a minimum period of 6 months. The principal investigator carried out a comparative analysis of several factors, including fracture morphology, orbital volume, globe projection, diplopia, facial morphic changes, lid retraction, and infraorbital nerve hypoesthesia. Results: Nine patients had impure orbital fractures, while the remainder had pure fractures. The median orbital volume on the normal side (30.12 cm3; interquartile range [IQR], 28.45-30.64) was comparable to that of the reconstructed orbit (29.67 cm3; IQR, 27.92-31.52). Diplopia improved significantly (T(10)= 2.667, p= 0.02), although there was no statistically significant improvement in globe projection. Gross symmetry of facial landmarks was achieved, with comparable facial width-to-height ratio and palpebral fissure lengths. Two patients reported infraorbital hypoesthesia at presentation, which persisted at the 6-month follow-up. Additionally, five patients developed lower lid retraction (1-2 mm), and one experienced implant impingement at the infraorbital border. Conclusion: Our study provides level II evidence supporting the use of 3D navigation to improve surgical outcomes in complex orbital reconstruction.

Finite Element Analysis of Orbital Forming Process in Bearing Manufacturing (베어링 제조공정중 궤도단조공정의 유한요소해석)

  • Moon H. K.;Lee M. C.;Chung J. H.;Joun M. S.
    • Transactions of Materials Processing
    • /
    • v.14 no.1 s.73
    • /
    • pp.29-36
    • /
    • 2005
  • In this paper, a useful rigid-plastic finite element method with various numerical schemes is presented for simulation of an orbital forming process. A new approach to reduce volume change during simulation is presented and an approximation method to reduce computational time is also presented. An actual orbital forming process found in a bearing making industry is simulated by the presented approach. The simulated results of the orbital forming process are compared with the experimental results.

Orbital Floor Reconstruction Using Endoscope and Selected Urethral Balloon Catheter (내시경과 선택적 도뇨관 풍선을 이용한 안와하벽복원술)

  • Choi, Hwan-Jun;Lee, Joo-Chul;Lee, Hyung-Gyo;Kim, Jun-Hyuk
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.35-42
    • /
    • 2011
  • Purpose: Blow-out fractures can be reduced using various methods. The orbital reconstruction technique using a balloon under endoscopic control has advantages over other methods. However, this method has some problems too, such as postoperative follow-up, management of the balloon catheter, and reduction of the posterior orbital floor. Thus, we developed a simple, effective method for orbital floor reduction that involves molding and shaping the antral balloon catheter. Methods: A 0, 30, or $70^{\circ}$, 4-mm endoscope was placed though a two-point, 5-mm maxillary antrostomy. The balloon catheter is placed directly at the orbital apex to reconstruct the anterior shelf (spherical shape), while it is turned in a U-shape towards the anterior maxilla for the posterior shelf (elliptical shape). Orbital floor defects, compound or comminuted fractures are reconstructed with alloplastic materials through an open lid incision under the endoscopic control. Results: This technique was applied to ten patients with orbital floor fractures: five anterior shelf and five posterior shelf fracture, respectively. Four of the patients had zygomatico-orbital fractures, while the rest had isolated orbital floor fractures. Two patients were given porous polyethylene implants Synpor$^{(R)}$) and three underwent reconstruction with a resorbable mesh plate. No complication associated with this technique was identified. Conclusion: The freestyle placement and selection of a urinary balloon catheter under endoscopic control and the preoperative estimation of the volume enhanced the stabilization of the orbital contour. This method improves the adaptation of the orbital floor without the risk of injuring the surrounding orbital contents, dissecting blindly, or using sharp traction. One drawback of this method is the patient's discomfort from the catheter during treatment.

Reconstruction of the orbital wall using superior orbital rim osteotomy in a patient with a superior orbital wall fracture

  • Heo, Jae Jin;Chong, Ji-Hun;Han, Jeong Joon;Jung, Seunggon;Kook, Min-Suk;Oh, Hee-Kyun;Park, Hong-Ju
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.42.1-42.5
    • /
    • 2018
  • Background: Fractures of the orbital wall are mainly caused by traffic accidents, assaults, and falls and generally occur in men aged between 20 and 40 years. Complications that may occur after an orbital fracture include diplopia and decreased visual acuity due to changes in orbital volume, ocular depression due to changes in orbital floor height, and exophthalmos. If surgery is delayed too long, tissue adhesion will occur, making it difficult to improve ophthalmologic symptoms. Thus, early diagnosis and treatment are important. Fractures of the superior orbital wall are often accompanied by skull fractures. Most of these patients are unable to perform an early ocular evaluation due to neurosurgery and treatment. These patients are more likely to show tissue adhesion, making it difficult to properly dissect the tissue for wall reconstruction during surgery. Case presentation: This report details a case of superior orbital wall reconstruction using superior orbital rim osteotomy in a patient with a superior orbital wall fracture involving severe tissue adhesion. Three months after reconstruction, there were no significant complications. Conclusion: In a patient with a superior orbital wall fracture, our procedure is helpful in securing the visual field and in delamination of the surrounding tissue.

Orbital wall restoring surgery with resorbable mesh plate

  • Joo, Jae Doo;Kang, Dong Hee;Kim, Hyon Surk
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.4
    • /
    • pp.264-269
    • /
    • 2018
  • Background: Orbital resorbable mesh plates are adequate to use for isolated floor and medial wall fractures with an intact bony buttress, but are not recommended to use for large orbital wall fractures that need load bearing support. The author previously reported an orbital wall restoring surgery that restored the orbital floor to its prior position through the transnasal approach and maintained temporary extraorbital support with a balloon in the maxillary sinus. Extraorbital support could reduce the load applied on the orbital implants in orbital wall restoring surgery and the use of resorbable implants was considered appropriate for the author's orbital wall restoring technique. Methods: A retrospective review was conducted of 31 patients with pure unilateral orbital floor fractures between May 2014 and May 2018. The patients underwent transnasal restoration of the orbital floor through insertion of a resorbable mesh plate and maintenance of temporary balloon support. The surgical results were evaluated by the Hertel scale and a comparison of preoperative and postoperative orbital volume ratio (OVR) values. Results: The OVR decreased significantly, by an average of 6.01% (p<0.05) and the preoperative and postoperative Hertel scale measurements decreased by an average of 0.34 mm with statistical significance (p<0.05). No complications such as buckling or sagging of the implant occurred among the 31 patients. Conclusion: The use of resorbable mesh plate in orbital floor restoration surgery is an effective and safe technique that can reduce implant deformation or complications deriving from the residual permanent implant.

SECONDARY REPAIR OF LATE ENOPHTHALMOS WITH CALVARIAL BONE GRAFTS AROUND INTRAORBITAL CONTENT -REPORT OF 2 CASES- (안와주위에 두개골이식을 통한 안구함몰의 이차적 성형재건 치험례)

  • Kim, Sung-Gil
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.4
    • /
    • pp.373-378
    • /
    • 1998
  • In the midfacial fracture, the orbital region presents many additional complication unique to the orbit. Among them are ectropion, entropion, lid ptosis, injury to the lacrimal apparatus, diplopia or the late development of enophthalmos. The residual problem confronting the surgen is usually enophthalmos or diplopia. Enophthalmos becomes cosmetically obvious at 3mm and if more severe it can interfere with vision from obstruction by the orbital rim. In this clinical situation, many patients prefer the simpler intraorbital volume expansion to the more complex orbital osteotomy. In general, except in mild cases of enophthalmos, the procedure of choice is osteotomy and repositioning for zygoma fracture and volume augmentation for blow-out fracture. Late treatment is performed by volume augmentation based on the CT findings behind the axis of the globe. Inferiorly placed grafts elevate the globe, posterior superior grafts move the globe anterior and medially positioned grafts push the globe laterally. In this two cases, the patients who has stable orbitozygomatic rim, the use of calvarial bone grafts more than 3 areas around intraorbital content, we corrected late enophthalmos combined with diplopia. As result, the first patient had 2mm advance in exophthalmometric check with improvement of the diplopia gradually. The second patient had 1.5mm advance with correction of vertical ocular dystopia and cosmetically good results respectively.

  • PDF

Three-Dimensional Pre-Bent Titanium Implant for Concomitant Orbital Floor and Medial Wall Fractures in an East Asian Population

  • Lee, Kyung Min;Park, Ji Ung;Kwon, Sung Tack;Kim, Suk Wha;Jeong, Eui Cheol
    • Archives of Plastic Surgery
    • /
    • v.41 no.5
    • /
    • pp.480-485
    • /
    • 2014
  • Background The objective of this article is to evaluate clinical outcomes of combined orbital floor and medial wall fracture repair using a three-dimensional pre-bent titanium implant in an East Asian population. Methods Clinical and radiologic data were analyzed for 11 patients with concomitant orbital floor and medial wall fractures. A combined transcaruncular and inferior fornix approach with lateral canthotomy was used for the exposure of fractures. An appropriate three-dimensional preformed titanium implant was selected and inserted according to the characteristics of a given defect. Results Follow-up time ranged from 2 to 6 months (median, 4.07 months). All patients had a successful treatment outcome without any complications. Clinically significant enophthalmos was not observed after treatment. Conclusions Three-dimensional pre-bent titanium implants are appropriate for use in the East Asian population, with a high success rate of anatomic restoration of the orbital volume and prevention of enophthalmos in combined orbital floor and medial wall fracture cases.

Quantitative Assessment of Orbital Volume and Intraocular Pressure after Two-Wall Decompression in Thyroid Ophthalmopathy

  • Park, Sang Min;Nam, Su Bong;Lee, Jae Woo;Song, Kyeong Ho;Choi, Soo Jong;Bae, Yong Chan
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.2
    • /
    • pp.53-57
    • /
    • 2015
  • Background: Surgical outcomes after orbital wall decompression have focused on the degree of exophthalmos and intraocular pressure. The aim of this research was to evaluate intraorbital volume using computed tomography (CT) images following two-wall decompression using a combined subcilliary and endoscopic approaches. Methods: A retrospective review was performed for all patients who had undergone the two-wall decompression method. The pre/postoperative CT images were used to evaluate changes in intraocular volume. Intraocular pressure was evaluated using applanation tonometry. Surgical details are discussed within the body of text. Results: Two-wall decompression thru the medial wall and floor was associated with an average intraorbital volume change of $7.3cm^3$, with maximal accommodation up to $13cm^3$. Changes in intraocular pressures were not statistically significant. Conclusion: Two-wall decompression was effective in accommodation of up to $13cm^3$ of soft tissue herniation. There was no statistically significant association between changes in volume to pressure.