• Title/Summary/Keyword: Orbital fractures

Search Result 124, Processing Time 0.027 seconds

Safety of Silastic Sheet for Orbital Wall Reconstruction

  • Moon, Seong June;Suh, Hyun Suk;Park, Bo Young;Kang, So Ra
    • Archives of Plastic Surgery
    • /
    • v.41 no.4
    • /
    • pp.362-365
    • /
    • 2014
  • Background Many implants are being used for the reconstruction of orbital wall fractures. The effect of the choice of implant for the reconstruction of an orbital wall fracture on the surgical outcome is under debate. The purpose of this article is to compare the outcomes of orbital wall reconstruction of small orbital wall fractures on the basis of the implants used. Methods The authors conducted a retrospective study using electronic databases. Between March 2001 and December 2012, 461 patients with orbital wall fractures were included in this study. Among them, 431 patients in whom the fracture size was less than $300mm^2$ were analyzed. The fracture size was calculated using computed tomography scans of the orbit in the sagittal and coronal images. Cases in which the fracture size was less than $300mm^2$ were included in this study. Results One hundred and twenty-nine patients were treated with silastic sheets; 238 patients were treated with titanium meshes; and absorbable meshes were used in the case of 64 patients. Overall, 13 patients required revision, and the revision rate was 3.0%. The revision rate of the silastic sheet group was 5.4%. In the multivariable analysis, the revision rate of the group reconstructed with silastic sheets was highly statistically significant (P=0.043, odds ratio=3.65). However, other factors such as age, sex, fracture type, and fracture size were not significant. Conclusions Reconstruction of orbital wall fractures with silastic sheets may cause more complications than that with other materials such as titanium meshes and absorbable meshes.

Two-Year Follow-up on the Use of Absorbable Mesh Plates in the Treatment of Medial Orbital Wall Fractures

  • You, Jae-Pil;Kim, Deok-Woo;Jeon, Byung-Joon;Jeong, Seong-Ho;Han, Seung-Kyu;Dhong, Eun-Sang;Kim, Woo-Kyung
    • Archives of Plastic Surgery
    • /
    • v.40 no.6
    • /
    • pp.728-734
    • /
    • 2013
  • Background Absorbable materials offer many advantages in the reconstruction of orbital walls; however, the possibility of postoperative enophthalmos after complete absorption cannot be excluded. We evaluated the postoperative results of absorbable mesh plates used as onlay implanting on the medial orbital wall to determine whether they are suitable for medial orbital wall reconstruction. Methods The study included 20 patients with medial orbital wall fractures who were followed up for more than 2 years postoperatively. We used absorbable mesh plates in all of the patients. We measured the following: the changes in the expanded orbital volume by comparing the preoperative and postoperative computed tomography (CT) scans and the degree of clinical enophthalmos. Results There were no major complications associated with the use of absorbable materials such as infection, migration, or extrusion of mesh plates during the long-term follow-up. The orbital volumetric changes between the preoperative and postoperative CT scans were not statistically significant. However, the expanded orbital volume was not related to the degree of clinical enophthalmos. Conclusions The reconstructed orbital wall may provide supportive scar tissue to the orbital contents even after the absorbable materials have dissolved completely. Absorbable mesh plates could be another option for the reconstruction of the medial orbital wall.

Degree of enophthalmos according to the extent of orbital wall fracture and volume of herniated orbital tissue (안와벽 골절 면적과 이탈된 안와내 조직의 부피에 따른 안구함몰 정도)

  • Jang, Hak-Sun;Leem, Dae-Ho;Baek, Jin-A;Shin, Hyo-Keun;Ko, Seung-O
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.3
    • /
    • pp.205-213
    • /
    • 2011
  • Introduction: The enlargement and deformation of the orbit give rise to a visible enophthalmos. As a consequence, a disturbance of eye motility together with double images is likely to occur. This study examined the degree of enophthalmos according to the extent of orbital wall fracture and volume of herniated orbital tissue in blowout fractures of the medial and inferior orbital wall. Materials and Methods: This study was performed on patients diagnosed with medial and inferior orbital wall fractures at the Department of Oral and maxillofacial surgery, Chonbuk National University Hospital from 2007 to 2009. The patients' age, gender, etiology of fracture and degree of enophthalmos were investigated. The changes in the degree of enophthalomos, diplopia and ocular motility restriction after operation were examined. Results: The degree of enophthalomos increased with increasing extent of orbital wall fracture and volume of herniated orbital tissue. Conclusion: Whether to perform the operation is decided after measuring the extent of the orbital wall fracture and volume of herniated orbital tissue using computed tomography (CT), time for the decision of operation can be shortened. This can cause a decrease in the complications of orbital wall fractures.

Approach for naso-orbito-ethmoidal fracture

  • Ha, Young In;Kim, Sang Hun;Park, Eun Soo;Kim, Yong Bae
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.4
    • /
    • pp.219-222
    • /
    • 2019
  • The purpose of this study is to discuss several approaches to addressing naso-orbito-ethmoidal (NOE) fracture. Orbital fracture, especially infraorbital fracture, can be treated through the transconjunctival approach easily. However, in more severe cases, for example, fracture extending to the medial orbital wall or zygomatico-frontal suture line, only transconjunctival incision is insufficient to secure good surgical field. And, it also has risk of tearing the conjunctiva, which could injure the lacrimal duct. Also, in most complex types of facial fracture such as NOE fracture or panfacial fracture, destruction of the structure often occurs, for example, trap-door deformity; a fracture of orbital floor where the inferiorly displaced blowout facture recoils to its original position, or vertical folding deformity; fractured fragments are displaced under the other fragments, causing multiple-packed layers of bone.

Endoscopic slide-in orbital wall reconstruction for isolated medial blowout fractures

  • Kim, Taewoon;Kim, Baek-Kyu
    • Archives of Craniofacial Surgery
    • /
    • v.21 no.6
    • /
    • pp.345-350
    • /
    • 2020
  • Background: This study evaluated the efficacy of the endoscopic medial orbital wall repair by comparing it with the conventional transcaruncular method. This surgical approach differs from the established endoscopic technique in that we push the mesh inside the orbit rather than placing it over the defect. Methods: We retrospectively reviewed 40 patients with isolated medial orbital blowout fractures who underwent medial orbital wall reconstruction. Twenty-six patients underwent endoscopic repair, and 14 patients underwent external repair. All patients had preoperative computed tomography scans taken to determine the defect size. Pre- and postoperative exophthalmometry, operation time, the existence of diplopia, and pain were evaluated and compared between the two methods. We present a case showing our procedure. Results: The operation time was significantly shorter in the endoscopic group (44.7 minutes vs. 73.9 minutes, p= 0.035). The preoperative defect size, enophthalmos correction rate, and pain did not significantly differ between the two groups. All patients with preoperative diplopia, eyeball movement limitation, or enophthalmos had their symptoms resolved, except for one patient who had preexisting strabismus. Conclusion: This study demonstrates that endoscopic medial orbital wall repair is not inferior to the transcaruncular method. The endoscopic approach seems to reduce the operation time, probably because the dissection process is shorter, and no wound repair is needed. Compared to the previous endoscopic method, our method is not complicated, and is more physiological. Larger scale studies should be performed for validation.

Orbital Wall Restoring Surgery in Pure Blowout Fractures

  • Lim, Nam Kyu;Kang, Dong Hee;Oh, Sang Ah;Gu, Ja Hea
    • Archives of Plastic Surgery
    • /
    • v.41 no.6
    • /
    • pp.686-692
    • /
    • 2014
  • Background Restoring orbital volume in large blowout fractures is still a technically challenge to the orbital surgeon. In this study, we restored the orbital wall using the combination of transorbital and transnasal approach with additional supports from the paranasal sinuses, and we compared the surgical outcome to that of a conventional transorbital method. Methods A retrospective review of all patients with pure unilateral blowout fractures between March 2007 and March 2013 was conducted. 150 patients were classified into two groups according to the surgical method: conventional transorbital method (group A, 75 patients, control group), and the combination of transorbital and transnasal approach with additional supports from the paranasal sinuses (group B, 75 patients, experimental group). Each group was subdivided depending on fracture location: group I (inferior wall), group IM (inferomedial wall), and group M (medial wall). The surgical results were assessed by the Hertel scale and a comparison of preoperative and postoperative orbital volume ratio (OVR) values. Results In the volumetric analysis, the OVR decreased more by the experimental groups than each corresponding control groups (P<0.05). Upon ophthalmic examination, neither the differences among the groups in the perioperative Hertel scale nor the preoperative and postoperative Hertel scales were statistically significant (P>0.05). Conclusions Our surgical results suggest that orbital volume was more effectively restored by the combination of transorbital and transnasal approach with additional supports from the paranasal sinuses than the conventional method, regardless of the type of fracture.

Survey and Review of Blowout Fractures (안와벽 파열골절에 대한 임상적 고찰)

  • Eun, Seok Chan;Heo, Chan Yeong;Baek, Rong Min;Minn, Kywng Won;Chung, Chul Hoon;Oh, Suk Joon
    • Archives of Plastic Surgery
    • /
    • v.34 no.5
    • /
    • pp.599-604
    • /
    • 2007
  • Purpose: Blowout fractures of the orbit are common sequelae to blunt facial trauma and now increasing in number due to automobile accidents, violence and industrial disasters. There are some reports of diagnosis and treatment of this fracture, but detailed data provided in overall aspects are very few. We analysed extensive data to provide guide line of blowout fracture patients care. Methods: We retrospectively studied 387 orbital blowout fracture patients who had been followed up at least 3-6 months. Their hospital records were reviewed according to causes, fracture site, operation methods, and follow up results, etc. Results: The ratio of males to females was 7 : 3 and fractures were most often seen in the 20-29 age group. 180(47%) patients had medial orbital wall fractures, 155(40%) patients had floor fractures and 52(13%) patients had a combination of orbital floor and medial wall fractures. The highest associated bone fracture was the nasal bone(37%). The open reduction was done in the 324 patients(83.7%) and insertion materials were used in the 249 patients(77%). Total 45 patients(14%) complained of residual diplopia and 26 patients(8%) kept mild enophthalmos. 24 patients(7%) showed some restriction of extraocular muscle movements. Conclusion: We broadly surveyed the information of blow out fracture patients and believe that this study provides important prognostic information that can be of benefit to both patient and surgeon during preoperative counseling and postoperative analysis of orbital blowout fractures.

Pediatric Orbital Blowout Fracture : A Retrospective Study of 116 Patients (소아 안와골절 환자의 임상적 고찰)

  • Kim, Jung Suk;Bae, Gyo Han;Park, Tai Jung;Jung, Tae Young
    • Journal of Clinical Otolaryngology Head and Neck Surgery
    • /
    • v.29 no.2
    • /
    • pp.198-203
    • /
    • 2018
  • Background and Objectives : Pediatric orbital blowout fractures occur in discreet patterns, in reference to the characteristic developmental anatomy of the facial skeleton at the time of injury. The purpose of this study was to investigate the clinical characteristics, ocular symptom, fracture type and postoperative results of orbital blowout fractures in the pediatric population. Material and Methods : A retrospective study was conducted from January 2009 to June 2015 in 116 patients with orbital floor fractures ; all less than 18 years old. Patients were divided into 3 groups by age : 0 to 6, 7 to 12, and 13 to 18 years of age. The cause of fracture, fracture site and type, preoperative and postoperative ocular symptoms, timing of surgery were reviewed from their records. Results : Medial wall fractures were the most common site in the 0 to 6 years old group, and floor fractures were the most common site in other age groups. However, floor fracture was the most common site of the need for surgery in all age groups. Trapdoor type of fractures occurred more frequently than open door type of fractures in all age groups. Preoperative symptoms did not differ among the 3 age groups. In case of need surgery, frequency of preoperative ocular symptoms increased with age. However, as age group was young, rate of residual postoperative ocular symptoms were increased. Conclusions : The younger patients are more to have trapdoor type fracture and residual postoperative ocular symptom. Earlier surgical intervention more needed for children with entrapment results.

Oculocardiac reflex in an adult with a trapdoor orbital floor fracture: case report, literature review, and differential diagnosis

  • Brasileiro, Bernardo Ferreira;Sickels, Joseph E. Van;Cunningham, Larry L. Jr.
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.6
    • /
    • pp.428-434
    • /
    • 2020
  • Orbital floor blowout fractures can result in a variety of signs and symptoms depending on the severity of the bone defect. Large defects often result in enophthalmos and restriction of ocular movement; yet the timing of surgery can be delayed up to two weeks with good functional outcomes. In contrast, an orbital trapdoor defect with entrapment of the inferior rectus muscle usually elicits pain with marked restriction of the upward gaze and activation of the oculocardiac reflex without significant dystopia or enophthalmos. When autonomic cardiac derangement is diagnosed along with an orbital floor fracture, it has been suggested that the fracture should be treated immediately. Otherwise, it will result in continued hemodynamic instability and muscular injury and may require a second surgery. This article reports the management of an unusual presentation of a trapdoor blowout orbital floor fracture surgery with oculocardiac response in an adult, with emphasis on its pathophysiology, management, and differential diagnosis.

Late reconstruction of extensive orbital floor fracture with a patient-specific implant in a bombing victim

  • Smeets, Maximiliaan;Snel, Robin;Sun, Yi;Dormaar, Titiaan;Politis, Constantinus
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.5
    • /
    • pp.353-357
    • /
    • 2020
  • Fractures of the orbital floor and walls are among the most frequent maxillofacial fractures. Virtual three-dimensional (3D) planning and use of patient-specific implants (PSIs) could improve anatomic and functional outcomes in orbital reconstruction surgery. The presented case was a victim of a terrorist attack involving improvised explosive devices. This 58-year-old female suffered severe wounds caused by a single piece of metal from a bomb, shattering the left orbital floor and lateral orbital wall. Due to remaining hypotropia of the left eye compared to the right eye, late orbital floor reconstruction was carried out with a personalised 3D printed titanium implant. We concluded that this technique with PSI appears to be a viable method to correct complex orbital floor defects. Our research group noted good aesthetic and functional results one year after surgery. Due to the complexity of the surgery for a major bony defect of the orbital floor, it is important that the surgery be executed by experienced surgeons in the field of maxillofacial traumatology.