• Title/Summary/Keyword: Orbital floor fracture

Search Result 47, Processing Time 0.02 seconds

Intraoral Approach and K-Wire Fixation of Zygomatic Tripod Fractures (강선 고정술을 이용한 관골골절의 치료)

  • Choi, See-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.1
    • /
    • pp.85-92
    • /
    • 1988
  • To avoid external facial scar which resulted from ordinary infraorbital and lateral eyebrow incision in surgical treatment of zygomatic tripod fractures, the author used intraoral incision and K-wire fixation method in 37 selected patients. This method contraindicated for the patient with multiple comminuted zygomatic fracture, patient combined with hard palatal fracture, and patient combined with herniated orbital floor fracture. The advantages of this method are simple, no external facial scar, and operate under direct visual field. The postoperative results were satisfactory. Balanced facial symmetry and good cosmetic results were obtained.

  • PDF

A Case of Penetrating Facial Wound by a Grinder (분쇄기에 의한 얼굴 관통창 1 례)

  • Kang, Jin-ah;Kim, Kang Ho;Paik, Jin Hui;Hong, Dae Young;Kim, Ji Hye;Lee, Kyoung Mi;Kim, Jun Sig;Han, Seung Baik
    • Journal of Trauma and Injury
    • /
    • v.19 no.1
    • /
    • pp.89-92
    • /
    • 2006
  • Penetrating facial wounds are uncommon and are usually life threatening because of the possibility of brain damage. There are three possible pathways for penetrating the cranium through the orbit: via the orbital roof, via the superior orbital fissure, or between the optic canal and lateral wall of the orbit. Brain injuries resulting from the penetrating wounds show extensive parenchymal damage, hemorrhage, and brain edema. Transorbital penetrating wounds can lead to diverse lesions of the optical apparatus, including the eye globe, the optical nerve, and the chiasm. Moreover, intracerebral structures may be hurt, and bleeding and infection may occur. Early diagnosis and prompt debridement are the fundamental factors affecting the outcome of a penetrating facial wound. An 87-year-old man was admitted to the emergency department with a grinder impacted into the medial aspect of the right eye. On presentation, the man was fully conscious with a Glasgow Coma Scale score of 15 and complained of a visual disturbance of the right eye. Computed tomography demonstrated a right orbital medial and inferior wall fracture, a frontal bone fracture, and a contusional hemorrhage in frontal lobe of the brain. A craniotomy with hematoma removal and repair of the orbital floor was done. He showed no neurological deficits except right visual loss. This appears to be the first report of a man with a penetrating facial wound caused by a grinder, who presented with a potentially disastrous craniocerebral injury that did not lead to any serious neurological seguelae.

Orbital floor fracture repair with implants: a retrospective study

  • Lee, Yong Jig
    • Archives of Craniofacial Surgery
    • /
    • v.22 no.4
    • /
    • pp.177-182
    • /
    • 2021
  • Background: Although prompt surgery after an orbital fracture is preferable, the actual timing of surgery in real-world settings varies. Therefore, this study investigated the outcomes of implant surgery for inferior orbital wall fractures by comparing three groups according to the time interval between the injury and surgery. Methods: A retrospective review was conducted of patients' medical charts and initial computed tomography images from 2009 to 2020. The time to treatment was chosen by patients or their guardians based on the patients' comorbidities and the physician's explanation. The patients were divided into three groups according to the time of surgery (group 1: 3-7 days, group 2: 8-14 days, group 3: 15 or more days). Data were collected on age, the time interval until surgery, the dimensions of the defect, the operation time, the follow-up period, and the postoperative paresthesia score (ranging from 0 to 10). The outcomes were evaluated using a 4-point scale: 4=good (no complications), 3=fair (no subjective symptoms), 2=poor (remaining paresthesia), and 1=very poor (strabismus and/or enophthalmos). Results: The study included 85 patients with unilateral fractures who underwent surgery from 3 to 93 days after injury. The overall score distribution of the surgical outcomes was as follows: good=63, fair=7, poor=6, and very poor=9. The three groups showed no significant differences in the transverse dimension of the injury (p=0.110) or the anteroposterior dimension (p=0.144). In groups 1, 2, and 3, the postoperative outcome scores were 3.84±0.37, 3.63±0.87, and 2.93±1.33 (p=0.083), and the percentage of patients with good outcomes was 84%, 81.25%, and 57.14%, respectively. Conclusion: Performing surgery using an artificial implant within 2 weeks of the injury showed better outcomes and fewer postoperative complications than when treatment was delayed.

CORRECTION OF POSTTRAUMATIC DIPLOPIA AND ENOPHTHALMOS USING AUTOGENOUS COMPOSITE CONCHAL CARTILAGE AND TEMPORAL FASCIAL;A CASE REPORT (이개연골과 측두근막의 자가복합이식술에 의한 외상성 복시현상과 안구함몰의 치험례)

  • Kim, Il-Kyu;Lee, Seong-Jun;Ha, Soo-Yong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.12 no.1
    • /
    • pp.114-120
    • /
    • 1990
  • This is a case report of correction of posttraumatic diplopia and enophthalmos using autogenous composite conchal cartilage and temporal fascia. The results are as follows. 1. Diplopia and enophthalmos may be persistent complications in zygomatic complex fracture. 2. The concha is a reservior of autogenous cartilage which leaves no cosmetic and functional deformity in reconstruction of orbital floor. 3. Warpping the cartilage in temporal fascia may serve to increase implant stability and get graft with smooth edge. 4. Donor incision lines are well hidden within the scalp and in auriculocephalic fold.

  • PDF

Delayed Foreign Body Reaction around the Absorbable Implants in Facial Bone Fracture: A Case Report (안면부 골절에 사용된 흡수성 보형물의 지연성 이물반응: 증례보고)

  • Suh, Yong-Hoon;Kim, Young-Joon
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.875-878
    • /
    • 2011
  • Purpose: Absorbable implants are frequently used to fix facial bone fractures, because they are radiolucent and compatible with magnetic resonance imaging (MRI). Despite their increasing usage, however, there have been few reports about their long-term side-effects. In this paper, a case in which absorbable implants led to a foreign body reaction 17 months after their insertion is presented. Methods: A previously healthy 19-year-old male fell from a flight of stairs and visited the authors' hospital with right periorbital pain. Zygomaticomaxillary fracture involving right orbital floor was detected via a facial bone computed tomography (CT). Internal fixation with absorbable implants was followed by open reduction. 17 months after the surgery, the patient complained of localized periorbital swelling. Removal of the granulomatous lesion including the absorbable implants along with their biopsy and culture was performed. Results: The granulomatous lesion around the implants was firm and extended into the maxillary sinus. The histologic finding showed a microabscess with a foreign body reaction. Methicillin-sensitive Staphylococcus aureus growth was confirmed in the culture. No definite abnormal symptoms ensued after the complete removal. Conclusion: A microabscess-forming granulomatous lesion around the absorbable implant can cause delayed symptomatic foreign body reaction despite its rare occurrence. Complete removal of the lesion including implants is expected to have a successful outcome if it is encountered.

Correction of Malunited Fracture of Zygoma Through Limited Incisions (제한적 접근을 통한 부정유합된 관골골절의 교정)

  • Kim, Yong-Ha;Kim, Sung-Ho;Seul, Jeung-Hyun;Lee, Kyung-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.13 no.1
    • /
    • pp.22-31
    • /
    • 1996
  • It is difficult to get a satisfactory result for the correction of malunited fracture of zygoma. Triple osteotomy and reposition of malunited zygoma is accepted as the better surgical method than camouflage surgery by means of onlays, if the orbital floor is to be reconstructed. The surgical approach can be divided into bicoronal, periorbital, intraoral and old scar. In 7 patients with malunited fracture of zygoma, the authors used a limited approach through extension of periorbital incision and intraoral incision instead of wide exposure including bicoronal incision. And we performed triple osteotomy and advancement of zygoma complex. The patients were followed for 4.5 months with acceptable result, and this approach was an effective method for the relatively simple tripod type-malunited fracture of zygoma. The authors obtained following conclusions: 1. Preoperative evaluation through thorough measurement of X-rays, investigation of photographs and detail communication with the patients was an important process. 2. Through lateral extension of subciliary incision, lateral eyebrow and intraoral incision, we could obtain adequate exposure for triple osteotomy and advancement of zygoma. 3. The zygoma should be reduced and fixed in an overcorrected superior and medial direction. 4. Return of zygoma to its anatomical position was possible only when it is completely freed from the surrounding soft tissue including masseter. 5. We could not find any different results between autogenous calvareal bone graft and $Medpor^{(R)}$ insertion on the floor of orbit.

  • PDF

Transconjuctival Incision with Lateral Paracanthal Extension for Corrective Osteotomy of Malunioned Zygoma

  • Chung, Jae-Ho;You, Hi-Jin;Hwang, Na-Hyun;Kim, Deok-Woo;Yoon, Eul-Sik
    • Archives of Craniofacial Surgery
    • /
    • v.17 no.3
    • /
    • pp.119-127
    • /
    • 2016
  • Background: Conventional correction of malunioned zygoma requires complete regional exposure through a bicoronal flap combined with a lower eyelid incision and an upper buccal sulcus incision. However, there are many potential complications following bicoronal incisions, such as infection, hematoma, alopecia, scarring and nerve injury. We have adopted a zygomaticofrontal suture osteotomy technique using transconjunctival incision with lateral paracanthal extension. We performed a retrospective review of clinical cases underwent correction of malunioned zygoma with the approach to evaluate outcomes following this method. Methods: Between June 2009 and September 2015, corrective osteotomies were performed in 14 patients with malunioned zygoma by a single surgeon. All 14 patients received both upper gingivobuccal and transconjunctival incisions with lateral paracanthal extension. The mean interval from injury to operation was 16 months (range, 12 months to 4 years), and the mean follow-up was 1 year (range, 4 months to 3 years). Results: Our surgical approach technique allowed excellent access to the infraorbital rim, orbital floor, zygomaticofrontal suture and anterior surface of the maxilla. Of the 14 patients, only 1 patient suffered a complication-oral wound dehiscence. Among the 6 patients who received infraorbital nerve decompression, numbness was gradually relieved in 4 patients. Two patients continued to experience persistent numbness. Conclusion: Transconjunctival incision with lateral paracanthal extension combined with upper gingivobuccal sulcus incision offers excellent exposure of the zygoma-orbit complex, and could be a valid alternative to the bicoronal approach for osteotomy of malunioned zygoma.