• 제목/요약/키워드: Optimum supply water temperature

검색결과 37건 처리시간 0.027초

난방부하와 온수온돌의 방열성능을 고려한 적정 공급온수온도 산출방법에 관한 연구 (A Study on the Method of Estimating Optimum Supply Water Temperature Considering the Heating Load and the Heat Emission Performance of Radiant Floor Heating Panel)

  • 최정민;이규남;류성룡;김용이;여명석;김광우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.795-800
    • /
    • 2006
  • A common approach to achieve better thermal comfort with hydronic radiant floor heating system is supply water temperature control. This is the control method through which supply water temperature is varied with outdoor temperature. In this study, a comprehensive, yet simple calculation method to find optimum supply water temperature is evaluated by combining heat loss from the building and heat emission from the hydronic radiant floor heating system. And then the control performance of suggested calculation method is confirmed through experiment. It is shown that indoor air temperature is stably maintained around the set point.

  • PDF

수온, 염분, 사육밀도 및 먹이공급이 왕우럭(Tresus keenae) 유생의 성장과 생존에 미치는 영향 (Effects of Water Temperature, Salinity, Rearing Density and Food Supply on the Growth and Survival of the Surf Clam, Tresus keenae Larvae)

  • 강한승;김철원
    • 한국해양생명과학회지
    • /
    • 제3권2호
    • /
    • pp.67-73
    • /
    • 2018
  • 본 연구는 수온, 염분, 사육밀도 및 혼합 먹이생물 공급량과 같은 환경요인이 왕우럭 Tresus keenae의 유생사육 시 생존 및 발생에 미치는 영향을 조사하기 위하여 수행하였다. 연구 결과, 왕우럭 유생사육의 최적 조건은 수온 20℃에서 24℃, 염분 30 psu, 사육밀도 1 ml당 5개체 및 먹이생물 I. galbana, C. simplex 및 T. suecica 혼합 공급량 10×104 세포/ml이였다. 본 연구 결과를 통해 밝혀진 왕우럭 유생 최적의 사육 환경요인은 빠른 성장 및 높은 생존을 통해 생산성 향상에 기여하리라 생각된다.

Automatic Control on Dosing Coagulant as to Stream Current

  • Oh, Sueg-Young;Byun, Doo-Gyoon;Hwang, Jae-Moon;Song, Hyun-Sung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1318-1321
    • /
    • 2005
  • As recently raw water quality has been polluted as well as its quality has been remarkably varied according to season and region, the precise control of coagulant dosage is being keenly required in water treatment plants. The amount of coagulant is closely related to raw water quality such as turbidity, alkalinity, water temperature, pH, electrical conductivity, etc. Since the optimum quantity of chemicals is not yet finalized, so dosage rate must be decided by using jar test that takes one or two hours. Hereupon, the output signal of stream current and multi-regression on historical data were proposed to be applied to the coagulant dosing control. In consequence of applying the scheme to automatic determination of the dosage rate, it was testified that the determination of dosage rate was very effective in case it is performed as to real-time sensing of water quality and the output signal of stream current.

  • PDF

R123 열원 적용 증발식 담수 시스템 특성 연구 (Characteristics of Solar Desalination System Using Refrigerant-123 As a Heating Source)

  • 윤상국;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제30권3호
    • /
    • pp.33-38
    • /
    • 2010
  • The evaporative desalination system using solar thermal energy would be the efficient and attractive method to get fresh water from brine due to low carbon dioxide generation. In this research the solar desalination system as a heating source of refrigerant R123 in the evaporator was considered. The circulation of refrigerant in the evaporator can reduce the energy consumption of the system, because of using the latent heat of the refrigerant 123 instead of the sensible heat of present hot water. The system was comprised of the single-stage fresh water production unit on the capacity of 1ton/day with shell and tube type evaporator, heaters instead of solar collector to supply the proper heat to refrigerant, and refrigerant and brine circulation systems. Various operating flowrate and temperature ranges were varied in the experiments to get the optimum design data. The results showed that the optimum flow rate of brine feed rate to evaporator was 1.2Liter/min, and the yield of fresh water was increased as higher temperature of feed brine. It was confirmed that the circulation flowrate of heating source of refrigerant was decrease of one fifth of the present warm water system, and very efficient system for solar desalination.

연근해 어선용 해수냉각장치의 열부하특성 (Heat Load Characteristics of Sea Water Cooling Apparatus on Inshore Fishing Boat)

  • 한인근;문춘근;김재돌;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권6호
    • /
    • pp.1317-1323
    • /
    • 2001
  • The circumstance is giving the blow against fishermen with the incoming-decreasing and the difficulty of crew's supply & demand and management. In addition, the depression of the external situation like the departure of WTO system and the plan of EEZ proclaim is forcing fishery into improving their fishing condition. By this international and domestic circumstance, development of the sea water cooling apparatus for fish hold storage is demanded sincerely. First of all, we Investigated load characteristics which based on development of sea water cooling system and optimum fish hold storage. The experimental results is as follows. In creasing the speed of compressor and mass blew rate of refrigerant, the temperature of NaCl solution is low. And the load characteristics experiment on fish hold storage outlet is as fellows. As time goes by, increasing the mass flow rate of NaCl solution, temperature difference between inlet and outlet is small in a model of fish hold storage. These results provide many useful informations applicable to an actual design of sea water cooling system and optimum fish hold storage.

  • PDF

공동주택 온수난방 시스템의 적정 열공급을 위한 배관망 시뮬레이션 (Simulation of Pipe Network for Optimum Heat Supply in the Hot Water Heating System of Apartment House)

  • 김주용;민만기;최영돈
    • 설비공학논문집
    • /
    • 제5권3호
    • /
    • pp.157-168
    • /
    • 1993
  • Pipe network of hot water heat supply system in an apartment house was analyzed. Flowrate and supply heat capacity of each household in which constant flowrate balancing valve is installed in a single zone system were calculated and the results were investigated. In the existing piping system, the non-uniformity of heat supply with floors due to the static pressure and temperature difference between supply main and return main can not be avoided and this tendency get intense with the increase of the height of building. The non-uniformity of heat supply can be prevented by the installation of balancing valve at each household, however if the performance of supply pump is not sufficient to overcome the energy loss due to the installation of balancing valve for constant flow rate or if the selection of the valve capacity is not adequate, the valves will may lose their controllability.

  • PDF

수평형 재생증발식 냉방기의 성능시험 (Performance Test for a Horizontal Regenerative Evaporative Cooler)

  • 송귀은;이대영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.621-626
    • /
    • 2006
  • Regenerative evaporative cooling is known as an environment-friendly and energy efficient cooling method. A regenerative evaporative cooler (REC) consisting of dry and wet channels is able to cool down the air stream below the inlet wet-bulb temperature. In the regenerative evaporative cooler, the cooling effect is achieved by redirecting a portion of the air flown out of the dry channel into the wet channel and spraying water onto the redirected air. In this study, a horizontal regenerative cooler is considered. In the horizontal regenerative cooler, the flow direction of evaporating water has a right angle to the flow direction of supply air. This difference was investigated with visualization technique and simplified 2-module performance test was done in a thermo-environment chamber. Optimum design configuration is changed due to the wet channel which are easily fully covered with evaporating water and block the air flow inside the channel. Applying the optimized fin configuration design with the highly wetting surface treatment, a regenerative evaporative cooler was fabricated and tested to Identify the cooling performance improvement and operation characteristics. From the experimental results at the intake condition of $32^{\circ}C$ and 50% RH, the supply temperature was measured to be around $23.4^{\circ}C$. The cooling effectiveness based on the inlet dewpoint temperature was evaluated 73% which is almost close to the design expectation.

  • PDF

저온온수 모세유관 바닥복사 난방시스템의 성능에 관한 실험적 연구 (Experimental Study on a Low-Temperature Hot Water Capillary Radiant Floor Heating System)

  • 조진균;박병용;이용준;정원호
    • 설비공학논문집
    • /
    • 제30권2호
    • /
    • pp.68-82
    • /
    • 2018
  • Radiant floor heating systems with capillary tubes are energy saving systems in which hot water is circulated into capillary tube with a small diameter. In this study, the heating performance of capillary tube system is investigated in an experimental study and a simulation model. The results of the study showed that, the capillary tube radiant floor heating system maintains a more stable floor surface temperature in comparison a PB pipe system. In terms of energy consumption, the capillary tube radiant floor heating system proved to be more efficient than the PB pipe heating system at $40^{\circ}C$ of low temperature hot water supply. The difference between water temperature and room temperature can be held low for heating which saves energy. Low temperature radiant floor heating system with capillary tubes have significant advantages such as health improvement, low energy cost, optimum use of heat source(boiler) and higher operational efficiency.

발효조의 냉각량 연속 측정 및 이를 이용한 유가배양제어 (On-line Measurement of Cooling Rate of a Fermenter and its Application for Fed-batch Control)

  • 허원;홍건표
    • KSBB Journal
    • /
    • 제18권5호
    • /
    • pp.418-423
    • /
    • 2003
  • 발효조의 냉각수 공급 제어 신호와 냉각수의 유출입 지점의 온도를 온라인으로 측정하여 이 값들로부터 냉각량을 추정할 수 있는 실험식을 얻었다. 회분식 배양을 통하여 냉각량이 온라인으로 측정될 수 있음을 확인하였고 기질의 재투입시 냉각량의 변화를 통하여 유가배양의 제어변수로 활용할 수 있음을 점검하였다. 미리 프로그램된 목표 냉각량의 증가곡선에 따라 냉각량이 증가되면서 세포가 자라도록 유가배양을 실시하였다. 본 연구를 통하여 냉각량의 온라인 측정방법을 제시하였고 이를 유가배양 제어변수로 활용하여 세포의 성장속도를 조절할 수 있음을 보였다.

인삼의 온도에 대한 생리반응 II. 엽의 생리, 지온, 기온, 병환의 생육 (Physiological Response of Panax Ginseng to Tcmpcrature II. Leaf physiology, soil temperature, air temperature, growth of pathogene)

  • 박훈
    • Journal of Ginseng Research
    • /
    • 제4권1호
    • /
    • pp.104-120
    • /
    • 1980
  • The effects of temperature on transpiration, chlorophyll content, frequency and aperture of stomata, and leaf temperature of Panax ginseng were reviewed. Temperature changes of soil and air under spade roof were also reviewed. Growth responses of responses of ginseng plant at various temperature were assessed in relation to suseptibillity of ginseng plants. Reasonable management of ginseng fields was suggested based on the response of ginseng to various temperatures. Stomata frequency may be increased under high temperature during leaf$.$growing stage. Stomata aperture increased by high temperature but the increase of both frequency and aperture appears not enough for transpiration to overcome high temperature encountered during summer in most fields. Serial high temperature disorder, i.e high leaf temperature, chlorophyll loss, inhibition of photosynthesis, increased respiration and wilting might be alleviated by high humidity and abundant water supply to leaf. High air temperature which limits light transmission rate inside the shade roof, induces high soil temperature(optimum soil temperature 16∼18$^{\circ}C$) and both(especially the latter) are the principal factors to increase alternaria blight, anthracnose, early leaf fall, root rot and high missing rate of plant resulting in poor yield. High temperature disorder was lessen by abundant soil water(optimum 17∼21%) and could be decreased by lowering the content of availability of phosphorus and nitrogen in soil consequently resulting in less activity of microorganisms. Repeated plowing of fields during preparation seems to be effective for sterilization of pathogenic microoganisms by high soil temperature only on surface of soils. Low temperature damage appeared at thowing of soils and emergence stage of ginseng but reports were limited. Most limiting factor of yield appeared as physiological disorder and high pathogen activity due to high temperature during summer(about three months).

  • PDF