• Title/Summary/Keyword: Optimum operating condition

Search Result 299, Processing Time 0.023 seconds

Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy (태양열 시설원예 난방시스템 장기실증 성능분석 연구)

  • Lee Sang-Nam;Kang Yong-Heack;Yu Chang-Kyun;Kim Jin-Soo
    • New & Renewable Energy
    • /
    • v.1 no.2 s.2
    • /
    • pp.53-59
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a green-house culture facility for reducing healing cost, Increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex In Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely Investigated by changing the control condition based on the temperature difference which Is the most important operating parameter For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, It is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

Development of the Driving Pump for the Low Noise Large Cavitation Tunnel (저소음 대형 캐비테이션 터널 구동 펌프 개발)

  • Ahn, Jong-Woo;Kim, Gun-Do;Kim, Ki-Sup;Lee, Jin-Tae;Seol, Han-Shin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.45 no.4
    • /
    • pp.370-378
    • /
    • 2008
  • It is reported to develop the driving pump for the Low Noise Large Cavitation Tunnel(LOCAT) which is under construction at Maritime & Ocean Engineering Research Institute(MOERI). For low background noise condition of the LOCAT, it is crucial not only the best pump efficiency but also no cavity occurrence at any operating conditions. Design condition of the pump is determined by considering the required pump headrise, flow quantity, shaft rotation velocity and pump diameter. Performance analysis of the pump is conducted using commercial CFD codes ($BladeGen^+$, CFX-10), and the predicted results are verified by a series of model tests. Cavity was not observed at any operating condition in the model test, which were conducted at the midium cavitation tunnel of MOERI. The optimum pump for LOCAT, named as LP-11, was successfully developed through a series of pump design processes composed of blade design, performance analysis and model test.

Development of a numerical flow model for the multi-cylinder engine intake system (다기통 엔진 흡기시스템의 유동해석 모델개발)

  • Song, Jae-Won;Seong, Nak-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.6
    • /
    • pp.1921-1930
    • /
    • 1996
  • To design an optimum engine intake system, a flow model for the intake manifold was developed by the finite difference method. The flow in the intake manifold was one-dimensional, and the finite difference equations were derived from governing equations of flow, continuity, momentum and energy. The thermodynamic properties of the cylinder were found by the first law of thermodynamics, and the boundary conditions were formulated using steady flow model. By comparing the calculated results with experimental data, the appropriate boundary conditions and convergence limits for the flow model were established. From this model, the optimum manifold lengths at different engine operating conditions were investigated. The optimum manifold length became shorter when the engine speeds were increased. The effect of intake valve timings on inlet air mass was also studied by this model. Advancing intake valve opening decreased inlet air mass slightly, and the optimum intake valve closing was found. The difference in inlet air mass between cylinders was very small in this engine.

Effect of Nozzle Initial and Exit Wall Angles on Supersonic Flow Field in a Thrust Optimized Nozzle (추력이 최적화된 노즐의 초음속 유동에 대한 노즐벽 초기 및 출구각도의 영향)

  • Jeon, Tae Jun;Park, Tae Seon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.3
    • /
    • pp.1-13
    • /
    • 2021
  • Effects of the nozzle wall angles on the supersonic flow field in a thrust optimized nozzle were numerically investigated. The combustor and operating condition of 30-tonf rocket engine was selected to study the optimum nozzle shape. The nozzle flow of combustion products was realized by the shifting equilibrium calculation for the propellant of kerosene-LOx. The change of nozzle wall angles induced different developing patterns of the internal and secondary shock wave. The optimum nozzle was obtained when the internal shock was in a specific position at the nozzle outlet. The nozzle wall angles of the optimum nozzle were very similar to those of the optimum nozzle which does not consider the shock wave.

A Simulated Prediction for Influences of Operating Condition in an Alkaline Fuel Cell

  • Jo Jang-Ho;Yi Sung-Chul
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.3
    • /
    • pp.163-170
    • /
    • 1999
  • The effects of the operating conditions in AFC single cells have not been studied in detail. In this study, by using a one-dimensional isothermal model a computational simulation was conducted to investigate the effects of the initial electrolyte concentration and the operating gas pressure. According to the result, the optimum electrolyte concentration at the base-case was found to be within $3.0\~3.5$ M. The variation of the cell performance according to the electrolyte concentration was found to be caused mainly by the charge transfer resistances of both electrodes, Henry's constant and the liquid phase diffusivity of the dissolved gases. It was also found that an increase in operating pressure increased the reaction rates and the solubilities of the gases, which led to a considerable enhancement of the cell performance.

LCD 백 라이트용 면광원 구동을 위한 고전력 고효율 인버터의 설계 및 제작

  • Hong, Ki-Seung;Lee, Hwan-Woong;Hur, Jeong-Wook;Lim, Sung-Kyoo
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2001.11a
    • /
    • pp.200-204
    • /
    • 2001
  • The high efficiency and high power inverter for driving LCD backlight was designed and fabricated. The operating frequency was variable and dimming capability was also included. High dimming ratio could be achieved by PWM dimming. The optimum driving condition for LCD backlight could be obtained by using the excited type inverter.

  • PDF

A Study on the Design of EL Inverter using FET (FET를 이용한 EL용 인버터 설계에 관한 연구)

  • 이기제;윤석암;윤형상;조경재;최장균;임중열;차인수;이경섭
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.456-459
    • /
    • 1999
  • This paper presents about EL(electroluminescent) driver with inverter. Inverter is composited two FET to increase safety output voltage. As result this study, the optimum operating condition of inverter is that the gate bias frequency of FET equal two resonant frequency of circuit. It shows to ideal sinusoidal output wave. Finally, EL sampler(15cm$\times$15cm) gain 2.6 [lux] with 1cm.

  • PDF

Piston control of hydraulic cylinder using an learing strategy (유압실린더의 학습에 의한 위치제어)

  • 박성환;권기수;허준영;이진걸
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.1122-1126
    • /
    • 1991
  • As microcomputers have become widespread and the high speed solenoid valves have been developed, digitally controlled hydraulic systems are used in many applications. This study deals with position control of hydraulic cylinder operated by two port 3-way high speed solenoid valve using a self-learning strategy. This was done by developing a control algorithm for the microcomputer which always automatically adjust the length of control pulse to the optimum value in accordance with the error regardless of changes in the operating condition and physical differences between components. Tests carried out in the laboratory indicate that a positional accuracy could be improved.

  • PDF

The Cooling Effect of PAD Location and FAN Capacity on Greenhouse (PAD 위치 및 FAN 용량에 따른 온실의 냉방효과)

  • 이석건;이종원;이현우;김길동
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.399-404
    • /
    • 1999
  • This study were performed to find the cooling effect and to provide design data during summer season for the Pad& Fan system of greenhouse . The temperature variation along the greenhouse width were analyzed. Also, the effect of the pad location and fan capacity on the cooling of the greenhouse were analyzed. While Pad &Fan systems were operating the temperatures in greenhouse were very different along the meausring locations. It is recommeded that PAD location and FAN capacity should be considered to design the Fan and Pad system in order to provide greenhouse the optimum temperature condition.

  • PDF

Experimental Study on the Performance Characteristics for the Three Types of the Pulse Tube Refrigerators (맥동관 냉동기의 유형별 성능특성에 관한 실험적 연구)

  • Park, Seong-Je;Go, Deuk-Yong
    • 연구논문집
    • /
    • s.24
    • /
    • pp.27-39
    • /
    • 1994
  • lower vibration than in any other small refrigerators. The experimental results of three types of pulse tube refrigerators are presented in this paper. The objectives of this study are to develop the design technology of the double inlet pulse tube refrigerator and acquire its application method. As a preliminary experiment, the refrigeration performances of the basic, orifice and double inlet pulse tube refrigerator were investigated. The lowest temperature obtained in this experiment was 34.4K. The refrigeration capacity at the optimum operating condition of the double inlet pulse tube refrigerator was 23W at 80K.

  • PDF